Materials Programs Technical Information Exchange Public Meeting On Yee - May 2019 Appendix H to 10 CFR Part 50 Rulemaking Status

Rulemaking Status SRM-COMSECY-18-0016 - January 2019 (ML19009A513)

- Commission approved regulatory basis publication and use of the direct final rule (DFR) process to revise the testing and reporting requirements in Appendix H

- Clarify the specific edition of ASTM E185 applicable to reactor vessels purchased after 1982 (Commission-directed)

Regulatory Basis - April 2019 (ML19038A477)

- Provides basis for recommending DFR process in COMSECY-18-0016 Direct Final Rule Process:

- Used for non-controversial regulatory amendments (i.e., No significant technical or policy issues)

- Expedites the rulemaking process and minimizes the use of NRC resources

- Issue direct final rule with a companion proposed rule

- Provides an opportunity for public comment on the rule

- No significant and adverse public comments anticipated 2

Materials Programs Technical Information Exchange Public Meeting May 2019

Rulemaking Status (contd)

Direct Final Rule underway to:

- Eliminate the requirements associated with weld heat-affected zone specimens and thermal monitors

- Reduce the number of tensile specimens that require testing

- Specify that testing correlation monitor material is optional

- Increase the reporting period for capsule reports from one year to 18 months Additional Consideration in SRM-COMSECY-18-0016

- Potential to misinterpret Appendix H as requiring the use of an ASTM standard not currently incorporated by reference

- Revise Section III.B.1 to clarify that ASTM E185-82 must be used when designing a surveillance program for reactor vessels purchased after 1982 Public Meeting held on April 30, 2019 - (ML19106A001)

- Provided status update and scope of this rulemaking activity Schedule

- Goal is to submit the DFR package to the Commission for review and approval by January 2020

- Direct Final Rule would become effective in late 2020 Materials Programs Technical Information Exchange Public Meeting May 2019