OFFICE OF NUCLEAR REACTOR REGULATION TABLE OF CONTENTS
- 1.
POLICY................................................................................................................................... 2
- 2.
OBJECTIVES.......................................................................................................................... 2
- 3.
PURPOSE............................................................................................................................... 2
- 4.
BASIC REQUIREMENTS....................................................................................................... 3
- 5.
RESPONSIBILITIES AND AUTHORITIES............................................................................. 4
- 6.
PERFORMANCE MEASURES............................................................................................... 4
- 7.
PRIMARY CONTACT............................................................................................................. 4
- 8.
RESPONSIBLE ORGANIZATION.......................................................................................... 4
- 9.
EFFECTIVE DATE.................................................................................................................. 4
- 10.
CERTIFICATION DATE.......................................................................................................... 4
- 11.
REFERENCES........................................................................................................................ 4 LIC-500, Revision 8 Topical Report Process Volume 500 Regulatory Improvements Approved By:
Mirela Gavrilas Date Approved:
February 6, 2020 Effective Date:
February 10, 2020 Certification Date:
February 10, 2025 Responsible Organization:
DORL Primary
Contact:
Ngola Otto 301-415-6695 Ngola.Otto@nrc.gov Summary of Changes: This issuance of LIC-500, Revision 8, Topical Report Process reflects: (1) revisions to integrate the guidance and work processes of both NRR and NRO and (2) changes to the secure electronic file sharing method.
Training: (1) Self-study by vendor/owners group project managers and Technical Branch staff and branch chiefs; (2) Training Session for vendor/owners group project managers.
ADAMS Accession Number:
- Indicates concurrence via e-mail.
OFFICE NRR/DLP/PLPB/PM NRR/DLP/PLPB/LA*
NRR/DLP/PLPB/BC NRR/DLP/D NAME NOtto DHarrison DMorey LLund DATE 5/20/2019 5/20/2019 6/11/2019 7/25/2019 OFFICE NRR/DSS/D*
NRR/DE/D NRR/DRA/D NRR/DMLR/D*
NAME JMarshall EBenner MFranovich JDonoghue DATE 7/18/2019 6/19/2019 6/21/2019 6/26/2019 OFFICE NRR/DORL/D*
NRR/DIRS/D NRO/DLSE/D*
NRR/OGC NAME CErlanger CMiller RTaylor S. Vrahoretis DATE 6/24/2019 6/21/2019 7/15/2019 10/9/2019 OFFICE NRR/DRMA NRR/DD NAME TGorham MGavrilas DATE 01 /27/2020 2/6/2020
NRR Office Instruction LIC-500, Revision 8 Page 2 of 4
- 1.
POLICY It is the policy of the Office of Nuclear Reactor Regulation (NRR) to establish procedures and guidance for its staff to meet the requirements and performance goals established in legislation, regulations, the Agencys strategic plan, and office-level operating plans.
Therefore, topical reports (TRs) are reviewed by the Nuclear Regulatory Commission (NRC) staff with the intent of maximizing their scope of applicability consistent with current standards for licensing actions, compliance with the applicable regulations, and reasonable assurance that the health and safety of the public will not be adversely affected. The NRC, through its website http://www.nrc.gov/about-nrc/regulatory/licensing/topical-reports.html, provides submittal guidance on the NRCs TR program, and transparency of NRC processes to public stakeholders.
- 2.
OBJECTIVE The TR process adds value by improving the efficiency of other licensing processes.
TRs improve the efficiency of the licensing process by allowing the staff to review proposed methodologies, designs, operational requirements, or other safety-related subjects on a generic basis so that they may be implemented by reference by multiple U.S. licensees, once acceptable for use and verified by the NRC staff. The objective of this office instruction (OI) is to define the process by which NRR project managers (PMs), technical staff, and managers process TRs and, thereby, improve NRRs efficiency and consistency in the review of TRs. Since this OI is made public, it also describes what to expect during the review process.
A TR is a stand-alone report containing technical information about a nuclear power plant safety topic. A TR provides the technical basis for a licensing action.
- 3.
PURPOSE The purpose of the NRC TR program is to minimize industry and NRC time and effort by providing for a streamlined review of a subject with generic applicability and the potential for subsequent referencing in multiple licensing actions. Industry organizations, such as a vendor or an owners group (OG), also referred to as an applicant throughout this OI, may choose or be requested by the NRC staff to submit TRs to address specific subjects.
NRR Office Instruction LIC-500, Revision 8 Page 3 of 4
- 4.
BASIC REQUIREMENTS 4.1 Overview of the Topical Report Process NRR's Licensing Projects Branch (LLPB), within the Division of Reactor Licensing (DORL), has the responsibility for managing the TR program.
The major activities covered in this procedure are given below and are separated into the following seven phases:
Phase 1: Submission Phase 2: Work Plan Development Phase 3: Completeness Review and Decision Letter Phase 4: Preliminary Safety Evaluation and Requests for Additional Information Phase 5: Draft Safety Evaluation Phase 6: Final Safety Evaluation Phase 7: -A Version Appendix A describes the change history.
Appendix B describes a procedure for processing submitted TRs.
A. Deal with a specific safety-related or other generic subject regarding a U.S. nuclear power plant that requires a safety evaluation (SE) by the NRC staff; for example, component design, analytical models or techniques, or performance testing of components and/or systems that can be evaluated independently of a specific license application.
B. Be applicable to multiple licensees, for multiple requests for licensing actions, or both. Examples of requested licensing actions include license amendment requests (LARs), relief requests, and other types of TR-based submittals that are not submitted pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 50.90 or Section 50.55a.
C. Increase the efficiency of the review process for applications that reference the TR.
Exceptions to these criteria, especially criterion B, may be allowed on a case-by-case basis if the NRC staff determines that an exception is in the public interest. The NRC staff reviews the applicants justification to determine if the exception is appropriate.
NRR Office Instruction LIC-500, Revision 8 Page 4 of 4 4.3 TR Review Fees TR reviews are subject to fees based on the full cost of the review (see 10 CFR 170.21). Exemption requests to the fee recovery requirements may be made concurrently to the Office of the Chief Financial Officer (refer to 10 CFR 170.11).
4.4 Topical Report Approval Status In order to be referenced in a plant-specific requested licensing action, a TR should be approved for use by the NRC. When approved for use, a -A is added to the TR title to indicate the TR is approved for use by the NRC staff. The NRC staff then performs a verification review, and following the NRC staff verification review, licensees may then reference the approved TR in plant-specific requests for licensing action.
- 5.
RESPONSIBILITIES AND AUTHORITIES The DORL Deputy Division Director has overall responsibility for the TR process.
- 6.
PERFORMANCE MEASURES The performance measures are contained in the Performance Plan. Timeliness and completion are also tracked in the quarterly performance report.
- 7.
PRIMARY CONTACT Ngola Otto 301-415-6695 Ngola.Otto@nrc.gov
- 8.
RESPONSIBLE ORGANIZATION DORL
- 9.
EFFECTIVE DATE February 10, 2020
- 10.
CERTIFICATION DATE February 10, 2025
- 11.
REFERENCE
Enclosures:
- 1. Appendix A - Change History
- 2. Appendix B - Guide for Processing Topical Reports
Appendix A LIC-500 Change History - Page 1 of 3 Date Description of Changes Method Used to Announce
& Distribute Training 08/08/2002 Initial Issuance E-mail to all staff Self-study by owners group PMs and TB section chiefs.
10/18/2002 This change adds: (1) a requirement for the staff to include in the safety evaluation conditions and limitations for the topical report, and (2) a choice of paragraphs that explain the billing policy to the acceptance review letter. There are also editorial changes, including a new web address.
E-mail to all staff Self-study by owners group PMs and TB section chiefs.
12/25/2003 This change reflects recent revisions to the topical report review process.
E-mail to all staff Self-study by owners group PMs and TB section chiefs.
06/24/2005 This change reflects recent revisions to the topical report review process.
E-mail to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs
LIC-500 Change History - Page 2 of 3 Date Description of Changes Method Used to Announce
& Distribute Training 12/21/2009 This change reflects recent revisions to the topical report review process.
E-mail to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs 10/04/2013 This change reflects: (1) modification of the TR prioritization strategy, (2) improved process to interface with NRO, (3) added review of Congressional Review Act applicability, (4) added staff verification of
-A version of TRs, and (5) various editorial updates and changes.
E-mail to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs 03/09/2018 This change reflects a comprehensive update of LIC-500 including: (1) various editorial updates and changes, (2) work planning development, (3) removal of the TR prioritization scheme, and (4) inclusion of a TR process roadmap.
E-mail to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs
LIC-500 Change History - Page 3 of 3 Date Description of Changes Method Used to Announce
& Distribute Training 10/18/2018 This change reflects a minor revision that will help ensure the proper process for transmitting documents is followed.
Email to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs 02/06/2020 This change reflects: (1) revisions to integrate the guidance and work processes of both NRR and NRO and (2) changes to the secure electronic file sharing method.
Email to all staff Self-study by vendor/owners group PMs and TB section chiefs.
Training session for vendor/owners group PMs
U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Appendix B Guide for Processing Topical Reports LIC-500, Revision 8
Table of Contents 1.0 Introduction...................................................................................................................... 3 1.1 Objective........................................................................................................................ 3 1.2 Process Overview.......................................................................................................... 3 2.0 Topical Report Review Process...................................................................................... 4 2.1 Phase 1: Submission..................................................................................................... 4 2.1.1 Notification of Intent to Submit................................................................................ 4 2.1.2 Requesting a Fee Exemption (if applicable)............................................................ 4 2.1.3 Work Tracking Software.......................................................................................... 4 2.1.4 Pre-submittal Meeting (OPTIONAL)........................................................................ 5 2.1.5 TR Submitted to Document Control Desk............................................................... 6 2.2 Phase 2: Work Plan Development................................................................................ 6 2.2.1 Resource Planning.................................................................................................. 7 2.2.2 Work Tracking Software Update............................................................................. 7 2.3 Phase 3: Completeness Review and Decision Letter................................................... 7 2.3.1 Completeness Review............................................................................................. 7 2.3.2 Proprietary Review.................................................................................................. 8 2.3.3 Work Planning......................................................................................................... 9 2.3.4 Decision Notification.............................................................................................. 10 2.4 Phase 4: Preliminary Safety Evaluation and Requests for Additional Information...... 10 2.4.1 Notify NRR Advisory Committee on Reactor Safeguards Coordinator of Topical Report 10 2.4.2 Review for Understanding..................................................................................... 11 2.4.3 Generate Preliminary Safety Evaluation............................................................... 12 2.4.4 Requests for Additional Information...................................................................... 12 2.4.5 Response to Requests for Additional Information................................................. 13 2.4.6 Review of Requests for Additional Information Responses.................................. 13 2.4.7 Proprietary Determination on Requests for Additional Information Responses.... 14 2.5 Phase 5: Draft Safety Evaluation................................................................................ 14 2.5.1 Develop Draft Safety Evaluation........................................................................... 14 2.5.2 Technical Staff Concurrence on Draft Safety Evaluation...................................... 14 2.5.3 Legal Review......................................................................................................... 15
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 2 of 19 2.5.4 Document Check on Draft Safety Evaluation.......................................................... 16 2.5.5 Draft Safety Evaluation Issued for Review and Comment..................................... 16 2.5.6 Comment on Draft Safety Evaluation.................................................................... 16 2.5.7 Resolve Comments on Draft Safety Evaluation.................................................... 17 2.6 Phase 6: Final Safety Evaluation................................................................................ 17 This phase begins after the Draft SE is complete and ends once the Final SE has been issued. 17 2.6.1 Develop Final Safety Evaluation........................................................................... 17 2.6.2 Issue Final Safety Evaluation................................................................................ 17 2.7 Phase 7: -A Version................................................................................................... 17 2.7.1 Congressional Review Act Rule Evaluation.......................................................... 17 2.7.2
-A Version of Topical Report is Submitted.......................................................... 18 2.7.3 Verify Changes to the Accepted Topical Report................................................... 18 2.7.4 Verification Letter.................................................................................................. 18 2.7.5 Closure of the Project............................................................................................ 19
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 3 of 19 1.0 Introduction The topical report (TR) review process should adhere to the guidelines established within this section. Variances in durations should be evaluated and managed by the project manager (PM) with input from the technical staff.
- Note: The Topical Report Process Roadmap is included with this document as.
1.1 Objective The objective of this guide is to provide the Office of Nuclear Reactor Regulation (NRR) staff a basic framework to process TRs.
1.2 Process Overview This guide provides a procedure for processing TRs. The U.S. Nuclear Regulatory Commission (NRC) staff effort is comprised of:
discussions prior to submittal, including meetings to solicit staff feedback; a submittal that the NRC staff will review; work planning, to achieve agency goals; an evaluation of the submitted materials for completeness and proprietary protection; specific work planning within the reviewing branches; a technical evaluation, including but not limited to, confirmatory calculations, audits, or meetings; writing a preliminary safety evaluation (SE) with allowances for portions that require resolution of staff concerns (open items);
requesting information that is essential to complete the drafting of an SE, including discussions to ensure the staffs concerns are understood; review of additional materials; potentially requesting more information; drafting of the SE, including limitations and conditions; a comment period for the applicant to indicate proprietary information, factual errors, or interpretation challenges; NRC staff resolution of comments received and finalizing the SE; submittal of a clean version of the TR, designated as -A version that includes all of the materials relied upon by the staff to reach its regulatory decision(s);
NRC staff verification of the -A submittal, including a closeout letter designating the TR as approved-for-use.
The major activities covered in this procedure are given below and are separated into the following seven phases:
Phase 1: Submission Phase 2: Work Plan Development
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 4 of 19 Phase 3: Completeness Review and Decision Letter Phase 4: Preliminary Safety Evaluation and Requests for Additional Information Phase 5: Draft Safety Evaluation Phase 6: Final Safety Evaluation Phase 7: -A Version 2.0 Topical Report Review Process The TR review process is organized into seven phases, with each phase separated into a number of tasks. Refer to Attachment 1, Topical Report Process Roadmap, for an outline overview of the TR review process.
2.1 Phase 1: Submission Much of this phase is focused on those activities which occur before the submittal process, namely the pre-submittal meetings. While these meetings are optional, most applicants choose to use pre-submittal meetings for the efficiencies that they add to the process. As described below, these meetings can be a valuable tool in obtaining NRC staff feedback, if used correctly. This phase ends when the TR has been submitted to the NRC and is placed on the docket.
2.1.1 Notification of Intent to Submit The applicant notifies the PM of the intent to submit a TR. This notification can be as simple as an email or as formal as a letter to the NRC. From the notification, the PM should communicate basic details about the TR to the appropriate technical organizations, including the subject area (e.g., fuels related, component inspection, accident analysis), number of licensees likely to utilize the TR, and intended date of submittal. If the organization has not submitted a TR before and does not have a docket number, the PM will obtain one.
2.1.2 Requesting a Fee Exemption (if applicable)
TR reviews are subject to fees based on the full cost of the review.
Title 10 of the Code of Federal Regulations (10 CFR) Part 170 sets the basic requirements for collection of fees for services rendered. NRC Management Directive 4.6, "License Fee Management Program,"
promulgates the broad policy and guidance to NRC offices for fee collection. Requests for exemptions to the fee recovery requirements may be made concurrently with the technical review.
2.1.3 Work Tracking Software The PM will generate a new project by providing input to the work tracking software and ensures that the technical staff has the appropriate information to charge their time.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 5 of 19 2.1.4 Pre-submittal Meeting (OPTIONAL)
A. Purpose There are generally two different purposes of a pre-submittal meeting.
The first is to obtain NRC technical staff feedback on certain aspects of the planned TR. Such pre-submittal meetings should occur well in advance of the TR submittal (e.g., several months or more), such that any issues identified by the NRC staff could be incorporated into the TR. The second is to inform the NRC staff that a TR will be coming in soon, introduce or remind them of the material, aid in work planning, and should occur as close to the submittal of the TR as reasonably possible.
Depending on the novelty and complexity of the TR, multiple pre-submittal meetings may be scheduled.
B. Preparation The PM should schedule a pre-submittal meeting (preferably face-to-face) with the applicant and the anticipated NRC technical review staff. In advance of the meeting, applicants are encouraged to provide an executive summary, any supporting documentation, and any presentation materials at least 15 working days in advance of the scheduled meeting.
Information provided to the NRC should clearly indicate the intended application and implementation expectations for the TR. The following examples are provided to assist the PM in providing guidance to the applicant:
Resolves generic safety issue (GSI) or emergent NRC technical issue Tied to a lead plant license amendment request (LAR)
Introduces a new technology with applicant identified safety improvement with expected implementation industry wide Current requirements or analytical methods intended only for partial groups of licensees with limited implementation Potentially applicable to licensee groups (BWROG, PWROG, BWRVIP, etc.) with expected implementation Implementation in the U.S. is or is not expected If this meeting, or any meeting during the TR review, is requested to be closed because the materials are considered proprietary, all materials should be submitted at least 30 days in advance. The 30-day period is needed to allow the NRC staff to review the information and make a determination of whether the NRC staff agrees it is proprietary.
Applicants should also work with the PM to develop a meeting agenda and identify a list of attendees. The PM should identify the appropriate technical branches to participate in the meeting, and work with the respective branch chiefs to identify the correct supporting staff.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 6 of 19 The PM should also coordinate Office of the Chief Financial Officer (OCFO) participation in pre-submittal meetings for TRs, for which a fee waiver has been or is likely to be requested.
Occasionally, a submitted TR has dual applicability to both operating and new reactors and must also be reviewed under the Part 52 licensing process. The PM will ensure that proper coordination takes place in an effort to maintain technical consistency.
C. During the Pre-submittal Meeting In order to achieve a more constructive pre-submittal meeting, the following list of suggested guidelines is provided:
Applicants:
Present the subject areas and the intended application of the TR (e.g., how many licensees may utilize the report, proposed applicability limits, the requested review schedule, etc.)
Provide technical detail on the approach, methods, and key assumptions Identify any anticipated hard spots or changes from an existing methodology that may require additional attention or review NRC staff:
Ask appropriate questions to elicit information on the relationship of the proposed TR to any other ongoing or proposed NRC staff or industry efforts Use knowledge and experience to provide feedback on the level of detail expected in the TR to conduct a detailed technical evaluation Provide feedback on the merits of the TR and clearly communicate any areas for improvement Make no decisions regarding TR acceptability 2.1.5 TR Submitted to Document Control Desk The guidelines regarding the process to submit documents to the document control desk (DCD) electronically are provided at:
https://www.nrc.gov/site-help/e-submittals.html 2.2 Phase 2: Work Plan Development This phase begins once the TR has been submitted on the docket and ends when the work begins. Most of the steps in this phase are focused on determining the level of effort required to complete the work, and the availability of the reviewers to schedule the work.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 7 of 19 2.2.1 Resource Planning The PM will coordinate with the technical BCs to initiate resource planning. Planning considerations include:
Identification of lead and supporting technical branches Estimation of review hours for each technical branch against available full time equivalent (FTE)
Identification of whether contract support is required Identification if a proprietary determination is needed Determination of whether the TR requires Technical Specifications (TS) branch review or concurrence. Examples include TRs that would involve Standard TS changes, or plant-specific TS changes upon implementation.
Identification if the TR has dual applicability with operating and new reactors Prioritization of emergent work Comparison of emergent work against planned work Determination of whether to shed or defer planned work Documentation of resource allocation 2.2.2 Work Tracking Software Update The PM will update the work tracking software to ensure that the technical staff has the appropriate milestones.
2.3 Phase 3: Completeness Review and Decision Letter This phase will begin when the technical staff assigned to the TR is scheduled to start the technical review. The first step is determining if the document submitted to the NRC is sufficiently complete to allow for an effective and efficient review.
In this instance, acceptable for review means that the TR is complete and all proprietary and non-proprietary information has been appropriately marked.
During this phase, the technical staff will generate a plan which details how the review will proceed. This phase ends with the issuance of the completeness determination.
2.3.1 Completeness Review The primary purpose of the completeness review is to determine whether the applicant has submitted a sufficiently complete set of information in order to initiate a detailed technical review of the TR. This effort is similar to, but more subjective than, the acceptance review that is performed for requested licensing actions under the NRR Office Instruction on acceptance reviews.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 8 of 19 In order to determine if a TR should be considered complete, such that the review may be started, the NRC staff should determine if one of the following criteria are true for that TR:
For TRs on subjects with which the assigned technical staff has great familiarity, the report should contain sufficient technical information such that the technical staff could be reasonably expected to complete the detailed technical review in an appropriate time frame.
For TRs on subjects with which the assigned technical staff has little familiarity, the report should not exclude obvious necessary technical information such that the technical staff could not be reasonably expected to complete the detailed technical review in an appropriate time frame.
If the relevant criterion is true, the TR should be accepted for review. If the relevant criterion is not true, the missing information should be summarized and quantified. If only a small amount of information is lacking, such that the TR could be supplemented in a reasonable time frame, the applicant should be informed of the missing information and given a chance to supplement the TR. If a large amount of information is lacking, such that the TR could not be supplemented in a reasonable time frame, the applicant should be informed of the missing information and the TR should be rejected.
2.3.2 Proprietary Review A. Purpose The purpose of the proprietary review to determine if the material marked as proprietary in the submittal satisfies the requirements of 10 CFR 2.390 for withholding from public disclosure.
B. Proprietary Review The proprietary review should be performed at the same time as the completeness review. The NRC staff should follow the guidelines set forth in LIC-204, Handling Requests to Withhold Proprietary Information from Public Disclosure, to perform this review. The technical staff will support this effort as required.
If the NRC staff determines that some or all the information designated by the applicant as proprietary is not proprietary, the PM should attempt to resolve the issue. The NRC staff should not continue with the review if there is a disagreement about the information designated as proprietary.
The minimum possible amount of information should be designated as proprietary.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 9 of 19 C. Withholding Letter The PM will issue a letter documenting the results of the proprietary determination review.
2.3.3 Work Planning Leveraging, to the extent practical, the information obtained from the completeness and proprietary review, the assigned technical staff should set out a work plan. This plan should focus on estimating the hours to complete the remaining assigned tasks. Additionally, other work which may be required to complete the review should be identified and the time to complete that work estimated. The following are examples of components of the overall review plan:
Reviewing the TR for understanding Performing the Audit for understanding Performing confirmatory analysis Visiting experimental facilities Obtaining contractor support Obtaining support from the Office of Nuclear Regulatory Research Generating the preliminary SE and request for additional information (RAI) questions Holding the preliminary RAI call Updating the preliminary SE with RAI responses Completing the Draft SE Accounting for Congressional Review Act (CRA) rule determination (allowing up to a 90-day period for obtaining and Office of Management and Budget (OMB) CRA review between the draft and final topical report safety evaluation. This process may not require all 90 days but the duration of the process, including OMB review period can vary from rule.)
Accounting for Office of the Advisory Committee on Reactor Safeguards (ACRS) review, if necessary Consider the above review activities when establishing a review plan in the work tracking software. This should include an estimation of review hours for each technical branch against available FTE.
Monthly management meetings are held with applicants who currently have a high quantity of TRs being processed or who have requested a meeting on the basis it has one or more high priority TRs. Meetings are held with respective BCs, PM, and Division management. The objective of these meetings is to ensure that status is communicated, challenges and major actions are assigned correctly, and completion dates (e.g., TR submission, acceptance letter issued, RAI questions issued, applicant response to RAI questions, Draft SE issued, applicant comments to Draft SE submitted, and Final SE issued) are adjusted as needed. Applicant TR priorities are discussed and reevaluated. Reevaluation is based on major delays, new applications received, or critical input from applicants.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 10 of 19 Additional background information is also provided to applicable management, such as responsible division, technical review staff, and cognizant PM.
2.3.4 Decision Notification The PM will notify the applicant about the results of the completeness review by telephone, including the anticipated schedule and level of effort.
This should be followed by an e-mail to document the decision notification.
If, during the completeness review, the NRC staff determines that the TR will not be reviewed because it is not sufficiently complete, a letter to the applicant documenting this decision will be signed by the Branch Chief of DORL. The PM will notify the applicant in advance of issuing the letter.
2.4 Phase 4: Preliminary Safety Evaluation and Requests for Additional Information This phase marks the formal beginning of the detailed technical review. It begins directly after the completeness determination and ends when the RAI questions have been sent. The primary goal of this phase is the generation of the preliminary SE (i.e., SE with open items).
It is expected that a preliminary SE with open items will be prepared prior to the issuance of any RAI questions. However, in some cases, preparation of a preliminary SE with open items prior to issuance of RAI questions may have an overwhelmingly negative impact on the review schedule not commensurate with the benefit. In such cases, the requirement to complete a preliminary SE with open items prior to issuing RAI questions may be waived, provided the technical and project management BCs agree. This practice should be a rare exception to the general process.
2.4.1 Notify NRR Advisory Committee on Reactor Safeguards Coordinator of Topical Report The ACRS may wish to review the TR and the associated SE. Per the memorandum of understanding between the Office of Executive Director for Operations (OEDO) and the ACRS, and NRR Office Instruction that addresses interfacing with ACRS, the PM and the technical staff should coordinate with the NRR ACRS Coordinator to keep the ACRS informed of active reviews and determine if the ACRS desires to review the TR and associated SE.
If ACRS requests to review the TR and associated SE, the PM and technical staff should coordinate with the cognizant ACRS staff member for the schedule of the sub-committee and full committee meetings. The PM and technical staff will also be responsible for providing a copy of the SE in advance of any scheduled meetings to ensure the ACRS members
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 11 of 19 have adequate time to review the material. Briefings of the ACRS should be performed by the technical staff who performed the review of the TR.
The PM should add ACRS review to the milestone schedule and make adjustments accordingly (typical ACRS review will add approximately two months to the schedule). Any schedule adjustments and potential delays as a result of ACRS meetings should be communicated to management by the PM.
2.4.2 Review for Understanding The first step in reviewing the TR is for the technical staff to gain an understanding of the report. In the context of this office instruction, a distinction between reading through and understanding should be noted. Although subject to the complexity of the TR and differences in individual review practices, obtaining an understanding of a TR usually requires substantially more effort than reading the report through a single time.
- Note to Reviewers Consider using the following:
Audit for Understanding - In accordance with LIC-111, Regulatory Audits, the technical staff can perform an audit for understanding. Generally, the purpose of such an audit is to allow the staff to confirm the overall understanding of the submittal and gain a better understanding of the detailed calculations, analyses, bases, or any combination of the three, underlying the TR, which may not have been included in the formal submittal.
Comprehension Questions - Comprehension questions are generally simple questions about the meaning of the TR. A reviewer may choose to generate a list of such questions to aid in understanding and obtaining clarification regarding material in the TR. In some instances, comprehension questions may evolve into RAI questions.
Three Way Communication - In three-way communication, the sender gives the message, the receiver states the message in their own terms, and the sender confirms that the message was understood. For these purposes, the TR is the message. In some instances, the NRC staff may wish to re-state certain sections of the TR to confirm understanding.
Topical Report Comprehension - There are numerous ways to achieve comprehension of a TR. Common ways include: multiple re-readings of the TR, highlighting and making notes in the margin, summarizing key aspects of each section of a TR, etc. The reviewer should find the style that best suits his or her preferences.
RAI Categorization - Technical reviewers may wish to use a RAI Categorization Process to help identify the most significant topics addressed in RAI questions, and to help focus NRC staff and TR sponsor resources on those topics of highest significance. One example of a RAI Categorization process is given in DSS RAI Categorization Process
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 12 of 19 At the conclusion of the review for understanding, the technical staff should have a relatively complete understanding of the information in the TR and be able to begin drafting the preliminary SE with open items.
2.4.3 Generate Preliminary Safety Evaluation As soon as possible after completing the review for understanding, the NRC technical staff should create the preliminary SE. While drafting the preliminary SE, it is a good practice to focus solely on the TR review and minimize time spent on other tasks. Time spent working on other tasks tends to distract from the preliminary SE and may result in the reviewer having to relearn information. Maintaining dedication to the TR review effort while drafting brings efficiency to the process.
The preliminary SE should be developed before preparing RAI questions, excepting only those rare cases discussed in the introduction to Section 2.4. Developing the preliminary SE prior to drafting RAI questions helps to ensure that any areas where information is lacking informs the staffs determination of the additional information that is required. Writing a preliminary SE helps ensure that the staff identifies all areas where RAIs are needed in order to make a safety and regulatory finding on the TR. Additionally, writing the preliminary SE prior to issuing RAI questions may help reduce the number of rounds of RAI questions required.
2.4.4 Requests for Additional Information An RAI enables the staff to obtain essential information needed to make a regulatory decision, which may have been omitted from the TR as submitted. Additional guidance for writing RAI questions is provided in the NRR Office Instruction on the RAI process.
When the technical reviewer has completed the preliminary SE and prepared RAI questions, an e-mail is sent to the PM. This electronic transmission, either directly from the Technical BC or the technical staff with their BC on concurrence, acknowledges that a preliminary SE has been prepared, and that each RAI question relates to a topic of missing information essential to evolve from the preliminary SE to the Draft SE.
The PM will transmit RAI questions using the file-sharing method established by the Office of the Chief Information Officer (OCIO).
Subsequently, the PM will schedule a call to discuss the RAI questions to ensure that the RAI questions are understandable and the regulatory basis for the questions is clear. The PM and technical staff should participate in the call. Technical staff should discuss the significance of each RAI question (including any RAI questions that could result in limitations and conditions if not sufficiently resolved) to communicate the (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML18017A064).
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 13 of 19 expected level of effort required to complete the response. The PM should discuss the expected response date and ensure technical staff resources support the proposed response date(s). Some questions may require additional time. Responses may be provided on a staggered schedule. Finally, a second e-mail should be sent by the PM, retransmitting the RAI questions (including updates or revision) and the expected date(s) to provide response(s).
2.4.5 Response to Requests for Additional Information The applicant will review the RAI questions and respond to the NRC by the agreed upon date(s). The response will include the question verbatim, the answer to the question, and appropriate markings for any information in the RAI or their responses that is considered proprietary. If new proprietary information is included, a new affidavit will need to be submitted along with the RAI responses in accordance with 10 CFR 2.390. PMs will track timeliness and adherence to RAI response schedules. Any delays in responses should be raised to the BCs for schedule consideration as appropriate. Trends will be evaluated on the average timeliness to assess our processes and metrics.
If the applicant proposes changes to the TR as a result of the RAI questions, the applicant should include with the RAI responses a mark-up of the TR pages that it plans to change.
2.4.6 Review of Requests for Additional Information Responses The technical staff will review the RAI responses and then communicate to the PM whether any of the responses are incomplete (i.e., an apparent omission of requested information). If any RAI responses are found to be incomplete, the PM will then contact the applicant to identify the responses of concern and present options to the applicant for resolution.
Options, under most anticipated circumstances, include public meetings and/or audits to help to clarify information needed by the NRC staff to reach a safety conclusion. The result of these exchanges may or may not facilitate an additional round of RAI questions.
Under circumstances where a resolution cannot be reached between the applicant and the NRC staff on any incomplete RAI responses, the NRC staff will evaluate how to proceed with the SE. This may be in the form of limitations and conditions applied on the use of the TR within the SE or may result in the suspension or closure of a TR review. The basis for suspending or closing out a TR review should be communicated ahead of time by telephone to the applicant. Additionally, applicants may request the TR to be withdrawn via letter submission to the DCD.
Any efforts associated with the resolving incomplete RAI responses which have been determined to extend the review schedule will be identified to the applicant by the PM and updated in the appropriate tracking software.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 14 of 19 2.4.7 Proprietary Determination on Requests for Additional Information Responses If the RAI responses contain any new proprietary information, a proprietary determination review will be conducted in a manner similar to that described in Section 2.3.2.
2.5 Phase 5: Draft Safety Evaluation This phase begins after the RAI responses have been received and ends when all of the open items in the preliminary SE are closed and the preliminary SE becomes the Draft SE. This phase may also include any additional rounds of RAI questions.
2.5.1 Develop Draft Safety Evaluation The technical staff will update the preliminary SE as necessary with relevant information from the RAI responses.
2.5.2 Technical Staff Concurrence on Draft Safety Evaluation The Technical Staff BC will provide the Draft SE (as opposed to the preliminary SE with open items) to the PM via e-mail according to the schedule date. If more than one technical staff branch is responsible for providing SE input, an agreement should be reached ahead of time as to whether the technical lead should coordinate the inputs and provide an integrated SE to the PM or if each technical branch should provide separate inputs that the PM will subsequently combine.
The SE should clearly specify the scope of the TRs applicability. For example, in many cases TRs are only applicable to reactors of a certain type (e.g., BWR or PWR), reactor vendor (e.g., General Electric or Westinghouse), fuel type, etc. The applicability should be defined based upon key distinguishing features and need not be restricted to the examples above. The TR should also clearly identify any limitations and conditions the NRC staff has placed on the use of the TR, including plant-specific action items that a licensee referencing the TR will need to submit.
Limitations and Conditions are additional restrictions imposed by the NRC staff to further frame the scope of applicability of a TR and identify any additional plant-specific action items that will be required to support the staffs review of a licensees request to implement the TR. Limitations and conditions identify the efforts needed by the licensee on subsequent individual plant applications that will reference the TR. The limitations and conditions should be written with sufficient clarity that licensees will be able to provide the necessary information in requests for licensing actions and NRC reviewers will be able to efficiently process the licensing action.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 15 of 19 Limitations describe where the TR is applicable. For example, a submitted TR may have a model valid over all pressures, but the TR may state that the pressure range is limited to specific values. Conditions identify additional information or actions needed from a licensee in order to reference the TR in a plant-specific licensing request. For example, licensees requesting to implement the TR must provide plant-specific data or analysis to show that the plant still meets the applicable acceptance criteria.
Frequent and effective communications throughout the TR review process will facilitate early identification of NRC staff concerns and ensure that the NRC staffs basis for imposing any limitations and conditions in the SE are clearly understood in advance of issuing the Draft SE.
2.5.3 Legal Review OGC review of topical reports associated with licensing actions should be consistent with the OGC review described in LIC-101 regarding such action. In addition, the NLO review performed by OGC for the related licensing actions is discussed in COM-109, Section 4.1.2, No Legal Objection Reviews.
Topical report SEs that are referenced in and required to establish the safety or regulatory basis for a rulemaking or a licensing action such as a license amendment or exemption, design certification, or phased design review, should be submitted to OGC for legal review (no legal objection (NLO)). The factors below provide considerations for the timing of the legal review.
When a licensee provides a letter documenting the planned use of a vendor, owners group or industry organization TR in a near-term (within 18 months) licensing action, the PM must submit the topical report safety evaluation for OGC NLO review. OGC will review the safety evaluation for the TR cited by the licensee in its letter.
Topical report SEs for new, small modular, advanced, or micro reactors should be submitted to OGC for legal review (NLO) before issuance.
OGC review of other TR SEs will be at the discretion of the PM based on NRR Office Instruction COM-109, NRR Interfaces with the Office of General Counsel. If the TR SE is not submitted for OGC NLO review prior to issuance, then the PM will mark NOT REVIEWED in the OGC concurrence block. This will indicate for future users of the TR that NLO review was not conducted and is needed.
If a TR SE is not submitted for legal review prior to its issuance, when the staff accepts for review the first license amendment request referencing an approved TR SE not previously reviewed by OGC, the staff will provide OGC with the TR, the TR SE, and
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 16 of 19 the LAR review schedule. This approach should provide sufficient time for OGC to complete the legal review of the TR SE while the staff is reviewing the LAR that relies on it. Specific guidance for this process is incorporated in LIC-101, License Amendment Review Procedures.
2.5.4 Document Check on Draft Safety Evaluation The licensing assistant will ensure that the document satisfies the NRC requirements according to the NRC Style Guide. Following the document check, the PM will provide the technical staff with an electronically marked-up version of the Draft SE so the technical staff can ensure that no changes impacted the technical information provided in the Draft SE.
2.5.5 Draft Safety Evaluation Issued for Review and Comment The purpose of the Draft SE is to provide the applicant with the opportunity to identify any proprietary information and to correct any factual inaccuracies or clarify any potential misunderstandings.
The PM will issue the Draft SE by the scheduled date. Once the transmittal letter is signed and concurred upon by the LLPB BC, the PM may provide a copy of the Draft SE via file-sharing method established by the OCIO.
The letter transmitting the Draft SE will typically provide 20 business days to identify any factual inaccuracies or clarity concerns.
The letter transmitting the Draft SE will also include a statement that there are 10 business days to identify any proprietary concerns. The 10 business days are provided for the applicant to identify any proprietary concerns runs concurrent with the 20 business days provided to identify any factual inaccuracies or clarity concerns in the Draft SE. Other time frames may be agreed to by the NRC staff.
Draft SEs that are found to contain proprietary information will remain non-public.
2.5.6 Comment on Draft Safety Evaluation The applicant should read the Draft SE and provide comments to the NRC staff. Comments should generally be limited to topics such as (1) clarifications, (2) correction of inaccuracies, (3) markups of proprietary language, and (4) questions on the conditions and limitations. Depending on the resolution of the RAIs, the applicant may wish to delay the review to provide more information to reduce or remove a condition or limitation.
Depending on the magnitude of a supplement, the NRC staff may need to develop a new schedule.
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 17 of 19 2.5.7 Resolve Comments on Draft Safety Evaluation The applicant will identify any proprietary information, any factual inaccuracies, or request clarification in the Draft SE within the given time frame. The PM will provide these comments to the technical staff, and the technical staff will assist in the resolution of the comments.
2.6 Phase 6: Final Safety Evaluation This phase begins after the Draft SE is complete and ends once the Final SE has been issued.
2.6.1 Develop Final Safety Evaluation The technical staff will update the Draft SE as necessary with relevant information from the Draft SE comments. Some Final SEs will contain a comment resolution table.
2.6.2 Issue Final Safety Evaluation The PM will issue the Final SE by the scheduled date. Once the transmittal letter is signed and concurred upon by the LLPB BC, the PM should provide the submitter a copy of the Final SE via file-sharing method established by the OCIO. The PM issues the cover letter with the non-proprietary SE publicly. Another cover letter with the proprietary SE is issued as non-public.
2.7 Phase 7: -A Version The final phase of the review process begins after the final SE is sent to the applicant. This phase ends once the verification letter from the LLPB BC is issued, stating that the NRC staff has placed the accepted -A version into ADAMS.
2.7.1 Congressional Review Act Rule Evaluation All SEs must be submitted to OGC for CRA review. OGC must determine whether the NRC staffs SE qualifies as a rule under the congressional review act (CRA).
If OGC determines that the SE is NOT a rule under CRA, then this process is complete.
If OGC determines that the SE is considered a rule, the PM should prepare a CRA input summary to be submitted to OMB via NMSS rulemaking staff who are responsible for coordinating with OMB regarding the CRA and inform the applicant of additional delays that may occur. These summaries are generally submitted to NMSS rulemaking staff once the final SE has been issued and the -A version of the topical
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 18 of 19 report is being prepared. OMB uses these summaries to help determine whether rules qualify as major rules under the CRA. Though it occurs only rarely for NRC rules, if OMB finds a rule to be major, the CRA generally would prohibit the rule from taking effect until at least 60 days after completion of the Congressional notification step.
Once the OMB determination is provided, the PM will prepare and submit to the Office of Congressional Affairs three copies of the Final (signed)
SE and complete the respective GAO-001 forms for the Senate, the House, and the Government Accountability Office:
https://www.gao.gov/decisions/majrule/FED_RULE.PDF.
This step is imperative because the basis of CRA is that Congress must have the ability to review all final rules upon issuance.
2.7.2 -A Version of Topical Report is Submitted The -A version of the TR should be submitted within three months of receipt of the Final SE.
The -A version of the TR should incorporate the transmittal letter, the Final SE, an appendix containing the TR, TS, and Bases markup pages of the appropriate vendor STS (if the TR involved TS changes).
The RAI questions and responses should be included as an appendix to the TR. Alternately, if the TR has been revised to incorporate the RAI responses directly into the report, a table listing each RAI and where the changes were made in the TR can be used.
For a proprietary TR, the LLPB PM should ensure that both proprietary and non-proprietary versions are submitted to the NRC.
2.7.3 Verify Changes to the Accepted Topical Report The NRC staff will verify the contents of the -A version with a final review. The purpose of this review will be to verify that the -A TR contains the updated information that was submitted and reviewed (i.e., in RAI responses).
If NRC staff determines that the submitted -A version has not technically changed from what formed the basis for the NRC staff SE, the LLPB BC will sign a verification letter stating the TR can be used in future licensing actions.
2.7.4 Verification Letter The PM will prepare a verification letter that specifically states whether the TR can be referenced in licensing actions. If the SE has been provided to OMB for review under the CRA, the verification letter should not be issued until OMB determines the SE is not a major rule. If OMB
NRR Office Instruction LIC-500, Revision 8 Appendix B - Page 19 of 19 determines the SE is a major rule, the PM should consult with OGC on the next actions.
2.7.5 Closure of the Project Following the issuance of the verification letter, all actions toward the TR review are complete. The PM will close the project and notify the technical staff of its closure.
NRR Office Instruction LIC-500, Revision 8
- Page 1 of 3 Topical Report Process Roadmap Phase Task Responsibility Deliverable / Action Time Period Phase 1: Submission 2.1.1 Notification of Intent to Submit Applicant Email to PM 1 to 12 months prior to planned submittal date 2.1.2 Requesting a Fee Exemption (if applicable)
Applicant Letter to the OCFO in accordance with 10 CFR 170.11 Concurrently with TR submittal, or 6 to 12 months prior to submittal 2.1.3 Work Tracking Software PM Email containing Project number sent to all staff involved with review Follows receipt of notification from vendor on planned TR submittal 2.1.4 Pre-submittal Meeting Applicant, PM, Technical Staff Meeting (face to face)
Several months prior to planned submittal date 2.1.5 TR Submitted to DCD Applicant Submission of TR Applicant identified submittal date Phase 2: Work Plan Development 2.2.1 Resource Planning PM, Technical Staff BC Meeting Following TR submission 2.2.2 Work Tracking Software Update PM Update in work tracking software Following TR submission Phase 3: Completeness Review and Decision Letter 2.3.1 Completeness Review Technical Staff Technical staff assessment to PM on level of completeness 2.3.2 Proprietary Review Technical Staff, PM Letter from PM 2.3.3 Work Planning Technical Staff and BC Review plan is given to PM 2.3.4 Decision Notification PMs BC Decision is issued by the BC
NRR Office Instruction LIC-500, Revision 8
- Page 2 of 3 Topical Report Process Roadmap Phase Task Responsibility Deliverable / Action Time Period Phase 4: Preliminary Safety Evaluation and Requests for Additional Information 2.4.1 Notify NRR ACRS Coordinator of Topical Report PM Email is sent to NRR ACRS Coordinator Following Decision Notification 2.4.2 Review for Understanding Technical Staff Initial set of questions developed by Technical Staff for use in an Audit for Understanding 2.4.3 Generate Preliminary SE Technical Staff Preliminary SE for NRC use; basis for RAI development Follows Audit for Understanding 2.4.4 Requests for Additional Information PM, Technical Staff RAI questions issued 2.4.5 Response to RAI Applicant RAI responses sent to NRC 2.4.6 Review of RAI Responses Technical Staff Inform PM if responses are acceptable 2.4.7 Proprietary Determination on RAI Responses Technical Staff RAI responses are appropriately marked Phase 5: Draft Safety Evaluation 2.5.1 Develop Draft SE Technical Staff Draft SE 2.5.2 Technical Staff Concurrence on Draft SE Technical Staff and BC All open items are resolved 2.5.3 Legal Review PM PM forwards Draft SE to OGC 2.5.4 Document check on Draft Safety Evaluation PM, Technical Staff Technical Staff and Technical BC review 2.5.5 Draft Safety Evaluation Issued for Review and Comment PM Draft SE issued 2.5.6 Comment on Draft Safety Evaluation Applicant Comments provided to NRC 2.5.7 Resolve Comments on Draft Safety Evaluation PM, Technical Staff Technical Staff provide comment dispositions
NRR Office Instruction LIC-500, Revision 8
- Page 3 of 3 Topical Report Process Roadmap Phase Task Responsibility Deliverable / Action Time Period Phase 6: Final Safety Evaluation 2.6.1 Develop Final SE Technical Staff Final SE with Comment Resolution Table, if needed 2.6.2 Issue Final SE PM Final SE issued Phase 7: -A Version 2.7.1 Congressional Review Act (CRA) Rule Evaluation PM CRA input summary to the Office of Management and Budget 2.7.2
-A Version of TR is submitted Applicant
-A version of the TR submitted to the NRC 2.7.3 Verify Changes to the Accepted TR PM, Technical Staff All changes to the -A version of the TR are verified to be consistent with the Technical staffs expectations 2.7.4 Verification Letter PM Verification letter 2.7.5 Closure of the Project PM PM closes the project