Ltr. 05/03/19 Byron Station, Units 1 and 2 - Request for Information for an NRC Design Bases Assurance Inspection (Program): Implementation of the Environmental Qualification Program Inspection Report 05000454/2019012; 05000455/2019012 (DRS
ML19123A036
Person / Time
Site: Byron  
Issue date: 05/03/2019
From: Jasmine Gilliam
Engineering Branch 3
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
References
IR 2019012
Download: ML19123A036 (7)


See also: IR 05000454/2019012

Text

May 3, 2019

Mr. Bryan C. Hanson

Senior VP, Exelon Generation Company, LLC

President and CNO, Exelon Nuclear

4300 Winfield Road

Warrenville, IL 60555

SUBJECT: BYRON STATION, UNITS 1 AND 2REQUEST FOR INFORMATION

FOR AN NRC DESIGN BASES ASSURANCE INSPECTION (PROGRAM):

IMPLEMENTATION OF THE ENVIRONMENTAL QUALIFICATION PROGRAM

INSPECTION REPORT 05000454/2019012; 05000455/2019012

Dear Mr. Hanson:

On August 26, 2019, the U. S. Nuclear Regulatory Commission (NRC) will begin a triennial

baseline Design Bases Assurance Inspection (Program) at Byron Station. This inspection

will be performed in accordance with NRC Baseline Inspection Procedure 71111.21N,

Attachment 1.

The Design Bases Assurance Inspection will focus on the implementation of the Electrical

Equipment Environmental Qualification Program to verify you are maintaining the qualified

status of equipment during the life of the plant. The final selection of environmental

qualifications components to be reviewed during this baseline inspection will be identified

during the inoffice preparation week that occurs prior to the first onsite inspection week.

The inspection will include two weeks onsite. The inspection team will consist of three NRC

inspectors. The current inspection schedule is as follows:

Team preparation week: August 19-23, 2019

Onsite inspection weeks: August 26-30, 2019; and September 9-13, 2019.

Experience with previous baseline design inspections of similar depth and length has shown

this type of inspection is extremely resource intensive, both for the NRC inspectors and the

licensee staff. In order to minimize the inspection impact on the site and to ensure a productive

inspection for both parties, we have enclosed a request for information needed for the inspection.

It is important that all of these documents are up-to-date and complete in order to minimize the

number of additional documents requested during the preparation and/or the onsite portions of

the inspection. Insofar as possible, this information should be provided electronically to the lead

inspector. The information request has been divided into four groups:

The first group lists information necessary for our initial inspection scoping activities.

This information should be provided to the lead inspector no later than June 10, 2019.

The lead inspector will communicate the initial selected EQ components no later than

June 24, 2019.

B. Hanson

-2-

The second group of documents requested is those items needed to support our

in-office preparation activities. This set of documents should be provided to the lead

inspector at the Regional Office no later than July 22, 2019. During the in-office

preparation activities, the team may identify additional information needed to support

the inspection.

The third group includes the additional information above. This information should be

available to the team onsite on August 26, 2019.

The last group includes supporting information to be provided throughout the inspection.

Specifically, corrective action documents and questions developed during the inspection

are requested to be provided as the documents are generated.

In addition, the enclosure includes information and requests addressing inspection logistics.

The lead inspector for this inspection is Jasmine Gilliam. We understand that our licensing

contact for this inspection is Barb Dotson of your organization. If there are any questions about

the inspection or the material requested in the enclosure, please contact the lead inspector at

630-829-9831 or via e-mail at Jasmine.Gilliam@nrc.gov.

This letter does not contain new or amended information collection requirements subject

to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information

collection requirements were approved by the Office of Management and Budget, Control

Number 3150-0011. The NRC may not conduct or sponsor, and a person is not required to

respond to, a request for information or an information collection requirement unless the

requesting document displays a currently valid Office of Management and Budget Control

Number.

This letter and its enclosure will be made available for public inspection and copying at

http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in

accordance with Title 10 of the Code of Federal Regulations, Part 2.390, Public Inspections,

Exemptions, Requests for Withholding.

Sincerely,

/RA Robert Daley Acting for/

Jasmine Gilliam, Reactor Engineer

Engineering Branch 3

Division of Reactor Safety

Docket Nos. 50-454; 50-455

License Nos. NPF-37; NPF-66

Enclosure:

Document Request for Design Bases

Assurance Inspection EQ Program

cc: Distribution via LISTSERV

B. Hanson

-3-

Letter to Bryan C. Hanson from Jasmine Gilliam dated May 3, 2019.

SUBJECT: BYRON STATION, UNITS 1 AND 2REQUEST FOR INFORMATION

FOR AN NRC DESIGN BASES ASSURANCE INSPECTION (PROGRAM):

IMPLEMENTATION OF THE ENVIRONMENTAL QUALIFICATION PROGRAM

INSPECTION REPORT 05000454/2019012; 05000455/2019012

DISTRIBUTION:

Michael McCoppin

RidsNrrDorlLpl3

RidsNrrPMByron Resource

RidsNrrDirsIrib Resource

Darrell Roberts

John Giessner

Jamnes Cameron

Allan Barker

DRPIII

DRSIII

ADAMS Accession Number: ML19123A036

OFFICE

RIII

NAME

RDaley for

JGilliam:cl

DATE

05/03/19

OFFICIAL RECORD COPY

DOCUMENT REQUEST FOR DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM

Enclosure

I. ADMINISTRATIVE INSPECTION INFORMATION

Inspection Report Number:

05000454/2019012; 05000455/2019012

Onsite Inspection Dates:

August 26-30, 2019, and September 9-13, 2019

Inspection Procedure:

71111.21N, Design Bases Assurance Inspection (Program),

Attachment 1, Environmental Qualification (EQ) under

10 CFR 50.49 Programs, Processes, and Procedures

Lead Inspector:

Jasmine Gilliam, Reactor Engineer, RIII/DRS

630-829-9831

Jasmine.Gilliam@nrc.gov

Teammate Inspectors:

Benny Jose, Senior Reactor Engineer, RIII/DRS

Jorge Corujo-Sandin, Reactor Engineer, RIII/DRS

II. LOGISTICS

Email the following inspection logistics to the lead inspector by July 22, 2019, or sooner:

1. Inspection room name/number, directions from the main access facility, and phone

number;

2. Interview room name/number;

3. Response team contact information (names and phone numbers) and team roles

(e.g., management sponsor, lead, inspector counterpart);

4. Any site access/badging actions needed for each inspector;

5. Any dosimetry actions needed for each inspector;

6. Entrance meeting time (preferably after 11:00 am) and location;

7. Confirmation that the team will have access to a licensee computer with a nearby printer;

8. Confirmation that the team will have Wi-Fi access;

9. Cafeteria location and hours;

10. Engineering staff normal working hours; and

11. Any potential resource conflicts during the inspection (e.g., emergency drills and all-staff

meetings).

DOCUMENT REQUEST FOR DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM

2

III. INFORMATION REQUEST

Contact the lead inspector as soon as possible if you have any questions regarding this

information request. Provide the information electronically in pdf files, Excel, or other

searchable formats, preferably on some portable electronic media (e.g., CD-ROM, DVD).

The files should contain descriptive names, and be indexed and hyperlinked to facilitate

ease of use. Information in lists should contain enough information to be easily

understood by someone who has knowledge of light water reactor technology.

1. Information Requested for Initial Inspection Scoping Activities

The following information is requested by June 10, 2019, or sooner, to facilitate the initial

sample selection.

1.1.

Risk-ranking of top 250 components required to meet environmental

qualifications (EQ) from your site specific probabilistic safety analysis

sorted by Risk-Achievement Worth. Include values for Birnbaum Importance,

Risk-Reduction Worth, and Fussell-Veseley (as applicable). Provide any basic

event mapping used to develop the ranking of components.

1.2.

Probabilistic safety analysis listing of top 10 risk-significant systems.

1.3.

U.S. Nuclear Regulatory Commission Safety Evaluation Reports associated

with EQ.

1.4.

Updated Final Safety Analysis Report, Technical Specifications, Technical

Specifications Bases, and Technical Requirements Manual. If any of these

documents is not available electronically, contact the lead inspector.

Specifically identify which Updated Final Safety Analysis Report sections

address EQ (including seismic).

1.5.

Identify the various EQ standards (including year, edition, or revision) that the

station is committed to.

1.6.

Site (and corporate if applicable) procedures associated with the Title 10 of the

Code of Federal Regulations, Part 50.49, EQ Program for electrical components.

Include procedures for procurement of qualified equipment, maintenance of

qualified equipment, modification to qualified equipment (including Equivalency

or Commercial Grade Dedication (CGD) Programs), and material storage and

shelf life controls.

1.7.

EQ Design Basis Document, if applicable.

1.8.

Any open licensing commitments related to EQ, if applicable.

1.9.

EQ Master List. Specific issues to be identified include: safety classification

(safety-related or nonsafety-related), Regulatory Guide 1.97 instrumentation,

EQ qualification (e.g., DOR, NUREG-588, 50.49), original or replaced after

implementation of 50.49, plant location, and qualified life.

1.10. List of any installed equipment removed from the EQ Master List and basis for

DOCUMENT REQUEST FOR DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM

3

removal.

1.11. List of EQ solenoid valves that are normally continuously energized.

1.12. If EQ files were reviewed for Aging Management effects of license renewal,

identify which EQ files were modified/changed to incorporate appropriate actions

for the period of extended operation. Include any EQ Aging Management

Program documents.

1.13. List or drawings of plant areas that are subjected to EQ, identifying design

(limiting) temperature, high energy line break, radiation levels, etc. that the

associated equipment will have to be qualified to meet EQ. If the reactor unit

has obtained a power uprate (greater than 5 percent) provide same information

pre-update (earliest available if multiple uprates).

1.14. List of CGD evaluations performed, for which the dedicated parts have been

issued for installation (parts issued for the last 10 years) on EQ applications in

the plant. Include CGD evaluation number, name of part, component ID or

description of the component the part was issued to repair, work order, and date

issued or installed.

1.15. List of Corrective Action Documents related to the EQ Program or EQ of specific

components for the last 5 years.

1.16. Any self-assessment and/or audit of the EQ Program in the last 3 years.

1.17. Current management and engineering organizational chart.

1.18. Licensing point of contact information (name, phone number, and email).

2. Information Requested to Support Inspection Preparation Activities

The following information is requested by July 22, 2019, or sooner, to facilitate the

final inspection preparation. This information request is associated with the selected

components and should be separated by component (e.g., folder with component name

that includes EQ files, Qualification Test Reports, calculations, corrective action

documents, and maintenance history).

2.1.

Component/subcomponent EQ summary report.

2.2.

Qualification Maintenance Requirement Sheet or equivalent.

2.3.

List of corrective action documents associated with each selected component for

the last 5 years.

2.4.

Photos of any component in containment or high radiation areas, if available.

2.5.

EQ file, including associated Qualification Test Reports.

2.6.

Vendor manual. If an electronic copy is not available, include a statement

explaining this and provide a hard copy during the onsite phase of the inspection.

DOCUMENT REQUEST FOR DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM

4

2.7.

Preventive maintenance template.

2.8.

Last two performed work order (WO) for each associated EQ preventive

maintenance.

2.9.

List of corrective maintenance WOs for the last 10 years. Include WO number,

date performed, and brief one line description.

2.10. If repair work (e.g., a motor rewind) was performed under a purchase order,

provide the purchase order.

2.11. Thermal life calculation.

3. Additional Information to Be Provided Onsite

During the in-office preparation activities, the team may identify additional information

needed to support the inspection. The lead inspector will provide a list of the additional

information needed during the week of August 19, 2019.

4. Information Requested to Be Provided Throughout the Inspection

4.1.

Any corrective action documents generated as a result of the teams questions

during this inspection as the documents are generated.

4.2.

List of questions and/or document requests submitted by the team and their

status (e.g., open, closed) sorted by inspector. Provide daily by 2:30 p.m. to

each inspector. It is recommended to provide the team leader with a master list

sorted by inspector and each inspector with a list containing only the items

originated by that inspector.