Revision 27 to Updated Final Safety Analysis Report, Chapter 5, Containment, Table of Contents
ML19114A136
Person / Time
Site: Peach Bottom  Constellation icon.png
Issue date: 04/08/2019
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19114A265 List: ... further results
References
Download: ML19114A136 (5)


Text

PBAPS UFSAR SECTION 5.0 - CONTAINMENT TABLE OF CONTENTS SECTION TITLE 5.1

SUMMARY

DESCRIPTION 5.1.1 General 5.1.2 Primary Containment 5.1.3 Secondary Containment 5.2 PRIMARY CONTAINMENT 5.2.1 Safety Objective 5.2.2 Safety Design Basis 5.2.3 Description 5.2.3.1 General 5.2.3.2 Drywell 5.2.3.3 Pressure Suppression Chamber and Vent System 5.2.3.4 Penetrations 5.2.3.4.1 General 5.2.3.4.2 Pipe Penetrations 5.2.3.4.3 Electrical Penetrations 5.2.3.4.4 Traversing In-Core Probe Penetrations 5.2.3.4.5 Personnel and Equipment Access Locks 5.2.3.4.6 Access to the Pressure Suppression Chamber 5.2.3.4.7 Access for Refueling Operations 5.2.3.5 Isolation Valves 5.2.3.6 Primary Containment Venting and Vacuum Relief System 5.2.3.7 Primary Containment Cooling and Ventilation System 5.2.3.7.1 Design Criteria 5.2.3.7.2 System Description 5.2.3.8 Containment Atmosphere Control System 5.2.3.9 Containment Atmospheric Dilution System 5.2.3.9.1 Safety Objective 5.2.3.9.2 Safety Design Bases 5.2.3.9.3 Identification and Physical Arrangement 5.2.3.9.4 Containment Atmospheric Dilution System Instrumentation and Control 5.2.3.9.5 Description 5.2.4 Safety Evaluation 5.2.4.1 General 5.2.4.2 Primary Containment Characteristics During Reactor Blowdown 5.2.4.2.1 Primary Containment Characteristics During Reactor Blowdown - Mark I Containment Program Re-Evaluation 5.2.4.3 Primary Containment Characteristics After Reactor Blowdown CHAPTER 05 5-i REV. 26, APRIL 2017

PBAPS UFSAR TABLE OF CONTENTS (cont'd)

SECTION TITLE 5.2.4.3.1 General 5.2.4.3.2 Minimum Containment Pressure Available 5.2.4.3.3 Deleted 5.2.4.4 Primary Containment Capability 5.2.4.5 Primary Containment Leakage Analysis 5.2.4.6 Containment Integrity Protection 5.2.4.7 Penetrations 5.2.4.8 Isolation Valves 5.2.5 Inspection and Testing 5.2.5.1 Primary Containment Integrity and Leaktightness 5.2.5.2 Penetrations 5.2.5.3 Isolation Valves 5.2.5.4 Containment Atmosphere Control System 5.2.5.5 Containment Atmospheric Dilution System 5.3 SECONDARY CONTAINMENT SYSTEM 5.3.1 Reactor Building 5.3.1.1 Safety Objective 5.3.1.2 Safety Design Basis 5.3.1.3 Description 5.3.2 Reactor Building Heating and Ventilating System 5.3.2.1 Power Generation Objective 5.3.2.2 Power Generation Design Basis 5.3.2.3 Safety Design Basis 5.3.2.4 Description 5.3.3 Standby Gas Treatment System 5.3.3.1 Safety Objective 5.3.3.2 Safety Design Basis 5.3.3.3 Description 5.3.4 Safety Evaluation 5.3.5 Inspection and Testing CHAPTER 05 5-ii REV. 26, APRIL 2017

PBAPS UFSAR SECTION 5.0 - CONTAINMENT LIST OF TABLES TABLE TITLE 5.2.1 Principal Design Parameters and Characteristics of Primary Containment 5.2.2 Containment Penetrations Compliance with 10CFR50, Appendix J CHAPTER 05 5-iii REV. 26, APRIL 2017

PBAPS UFSAR SECTION 5.0 - CONTAINMENT LIST OF FIGURES FIGURE TITLE 5.2.1 Primary Containment 5.2.2 Primary Containment Process Line Penetration -

Type 2 5.2.3 Primary Containment Process Line Penetration -

Type 3 5.2.4 Primary Containment Instrument Line Penetration 5.2.5 Primary Containment Electrical Penetration 5.2.6 Deleted 5.2.7 Deleted 5.2.8 Hydrogen Flammability Limits 5.2.9 Deleted 5.2.10 Deleted 5.2.11A Deleted 5.2.11B Deleted 5.2.12 Drywell O2 and H2 Concentrations Following a LOCA -

Regulatory Guide 1.7 Analysis 5.2.13 Suppression Chamber O2 and H2 Concentrations Following a LOCA - Regulatory Guide 1.7 Analysis 5.2.14 Maximum Total Nitrogen Required for Dilution Versus Time Following a LOCA (Zero Containment Leakage) 5.2.15 Containment Pressure Versus Time Following a LOCA and Dilution with Nitrogen 5.2.16 Deleted 5.3.1 Deleted CHAPTER 05 5-iv REV. 26, APRIL 2017

PBAPS UFSAR LIST OF FIGURES (cont'd)

FIGURE TITLE 5.3.2 Deleted 5.3.3 Deleted CHAPTER 05 5-v REV. 26, APRIL 2017