LO-0419-65235 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Docket No. PROJ0769 April , 2019 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738

SUBJECT:

NuScale Power, LLC Submittal of Accident Source Term Methodology, TR-0915-17565, Revision 3

REFERENCES:

Letter from NuScale Power, LLC to Nuclear Regulatory Commission, NuScale Power, LLC Submittal of Topical Report Accident Source Term Methodology, TR-0915-17565, Revision 2, dated September 11, 2017 (ML17254B0468)

NuScale Power, LLC (NuScale) hereby submits Revision 3 of the Accident Source Term Methodology (TR-0915-17565) topical report. The purpose of this submittal is to request that the NRC review and approve NuScales accident source term methodology. contains the proprietary version of the report entitled Accident Source Term Methodology. NuScale requests that the proprietary version be withheld from public disclosure in accordance with the requirements of 10 CFR § 2.390. The enclosed affidavit (Enclosure 3) supports this request. Enclosure 2 contains the nonproprietary version of the report entitled Accident Source Term Methodology.

This letter makes no regulatory commitments and no revisions to any existing regulatory commitments.

If you have any questions, please feel free to contact Carrie Fosaaen at 541-452-7126 or at cfosaaen@nuscalepower.com if you have any questions.

Sincerely, Thomas A. Bergman Vice President, Regulatory Affairs NuScale Power, LLC Distribution: Samuel Lee, NRC, OWFN-8H12 Gregory Cranston, NRC, OWFN-8H12 : Accident Source Term Methodology, TR-0915-17565-P, Revision 3, proprietary version : Accident Source Term Methodology, TR-0915-17565-NP, Revision 3, nonproprietary version : Affidavit of Thomas A. Bergman, AF-0419-65236 Sincerely, Thhomas A. Bergman Vice Preside de de de de de de de de de de de dent, Regulato t ry Affairs NuScale Powe we we we we we we we weer,r,r,r,r,r,r,r,r,r,r,r,, LLCC

NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com :

Accident Source Term Methodology, TR-0915-17565, Revision 3, proprietary version LO-0419-65235

LO-0419-65235 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Accident Source Term Methodology, TR-0915-17565, Revision 3, nonproprietary version

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC i

Accident Source Term Methodology April 2019 Revision 3 Docket: PROJ0769 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 www.nuscalepower.com

© Copyright 2019 by NuScale Power, LLC

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC ii COPYRIGHT NOTICE This report has been prepared by NuScale Power, LLC and bears a NuScale Power, LLC, copyright notice. No right to disclose, use, or copy any of the information in this report, other than by the U.S.

Nuclear Regulatory Commission (NRC), is authorized without the express, written permission of NuScale Power, LLC.

The NRC is permitted to make the number of copies of the information contained in this report that is necessary for its internal use in connection with generic and plant-specific reviews and approvals, as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.390 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by NuScale Power, LLC, copyright protection notwithstanding. Regarding nonproprietary versions of these reports, the NRC is permitted to make the number of copies necessary for public viewing in appropriate docket files in public document rooms in Washington, DC, and elsewhere as may be required by NRC regulations. Copies made by the NRC must include this copyright notice and contain the proprietary marking if the original was identified as proprietary.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC iii Department of Energy Acknowledgement and Disclaimer This material is based upon work supported by the Department of Energy under Award Numbers DE-NE0000633, DE-NE0008820, and DE-NE0008742.

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC iv List of Affected Pages Revision Number Page Number Explanation 2

13, 15, 68 RAI Letter No. 6, Question 01.05-13 Response 2

17 RAI Letter No. 6, Question 01.05-14 Response 2

29 RAI Letter No. 6, Question 01.05-17 Response 2

32 RAI Letter No. 6, Question 01.05-18 Response 2

1, 3, 4, 5, 62, 128 RAI Letter No. 6, Question 01.05-20 Response 2

7, 24 RAI Letter No. 9, Question 01.05-22 Response 2

30 RAI Letter No. 9, Question 01.05-24 Response 2

75, 77, 78 RAI Letter No. 11, Question 01.05-31 Response 2

5, 17, 32 eRAI No. 8800, Question 15.00.03-2 Response 2

13, 14, 37, 38, 39, 45, 50, 52, 53, 97, 100, 103, 104, 129 eRAI No. 8881, Question 02.03.04-2 Response 2

27, 59, 91, 130 Editorial/Clarification Corrections 3

Throughout The terms "Category 1 and Category 2" are no longer used. The term design basis source term (DBST) no longer refers to the source term formerly known as the "Category 2 source term,"

but rather to the source term formerly known as "Category 1 source term."

3 Throughout Introduced the term core damage source term (CDST) for the source term formerly known as the "Category 2 source term."

3 Section 4.4 relocated to Section 5.8 Sensitivity examples moved to the example section.

3 Throughout Aerosol removal methodology changes driven by eRAI No. 9224.

3 Throughout Replaced references to forthcoming DCD and similar terms.

3 Throughout Replaced "source term design basis accident (STDBA) with "surrogate accident scenario to emphasize the beyond-design-basis nature of the core damage event (CDE) and associated CDST.

3 Sections 1.2, 4.2.1, 4.2.3, and 4.2.4 Core damage source term release timing and aerosol thermal hydraulic input methodology changes.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC v

CONTENTS 1.0 Introduction..................................................................................................................... 4 1.1 Purpose................................................................................................................. 4 1.2 Scope.................................................................................................................... 4 1.3 Abbreviations......................................................................................................... 5 2.0 Background................................................................................................................... 11 2.1 Regulatory Requirements.................................................................................... 13 2.2 Basis for Treating Core Damage Event as a Beyond Design Basis Event.......... 14 3.0 Methodology Overview................................................................................................. 15 3.1 Software.............................................................................................................. 16 3.1.1 SCALE 6.1/TRITON/ORIGEN-S.......................................................................... 16 3.1.2 NARCON............................................................................................................. 16 3.1.3 RADTRAD........................................................................................................... 17 3.1.4 MELCOR............................................................................................................. 17 3.1.5 NRELAP5............................................................................................................ 17 3.1.6 STARNAUA......................................................................................................... 18 3.1.7 pHT...................................................................................................................... 18 3.1.8 MCNP6................................................................................................................ 18 3.2 Overview of Design Basis Source Terms............................................................ 19 3.2.1 Rod Ejection Accident......................................................................................... 19 3.2.2 Fuel Handling Accident........................................................................................ 20 3.2.3 Main Steam Line Break outside Containment..................................................... 20 3.2.4 Steam Generator Tube Failure............................................................................ 21 3.2.5 Failure of Small Lines Carrying Primary Coolant outside Containment............... 22 3.2.6 Iodine Spike Design Basis Source Term............................................................. 23 3.3 General Methodology and Assumptions.............................................................. 25 3.3.1 Core Radionuclide Inventory............................................................................... 25 3.3.2 Primary Coolant Radionuclide Inventory............................................................. 26 3.3.3 General Dose Analysis Inputs............................................................................. 29 3.3.4 General Dose Analysis Assumptions................................................................... 31 3.3.5 Offsite Dose Calculation...................................................................................... 35

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC vi 3.3.6 Control Room Dose Calculation.......................................................................... 35 3.3.7 Containment Leakage......................................................................................... 36 3.3.8 Fuel Handling Accident Decontamination............................................................ 36 3.3.9 Iodine Spiking...................................................................................................... 36 3.3.10 Steam Generator Decontamination..................................................................... 37 3.3.11 Removal in Piping and Main Condenser............................................................. 37 4.0 NuScale Unique Methodology..................................................................................... 38 4.1 Atmospheric Dispersion...................................................................................... 38 4.1.1 PAVAN................................................................................................................. 38 4.1.2 ARCON96........................................................................................................... 40 4.1.3 Major Differences................................................................................................ 41 4.1.4 Atmospheric Dispersion Estimates in the Vicinity of Buildings............................ 42 4.1.5 PAVAN and ARCON96 Comparison.................................................................... 50 4.1.6 Application........................................................................................................... 55 4.2 Core Damage Event............................................................................................ 56 4.2.1 Definition of Core Damage Source Term............................................................. 56 4.2.2 Core Damage...................................................................................................... 57 4.2.3 Release Timing and Magnitude........................................................................... 58 4.2.4 Aerosol Transport Analysis.................................................................................. 58 4.2.5 Radiological Consequence Analysis................................................................... 59 4.3 Aerosol Removal and Transport.......................................................................... 60 4.3.1 STARNAUA......................................................................................................... 62 4.3.2 Sedimentation..................................................................................................... 62 4.3.3 Phoretic Phenomena (Diffusiophoresis and Thermophoresis)............................ 62 4.3.4 Hygroscopicity..................................................................................................... 63 4.3.5 Aerosol and Elemental Iodine Removal.............................................................. 65 4.3.6 Aerosol Resuspension and Revaporization........................................................ 65 4.3.7 Charge Effects on Aerosol Removal Rates......................................................... 65 4.3.8 Aerosol Plugging................................................................................................. 66 4.3.9 Experimental Benchmarking and Code Validation.............................................. 66 4.3.10 Benchmarking to MAEROS................................................................................. 70 4.3.11 Application........................................................................................................... 72

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC vii 4.4 Post-Accident pHT............................................................................................... 77 4.4.1 Dissociation Equation.......................................................................................... 78 4.4.2 Mass Balance Equation....................................................................................... 79 4.4.3 Charge Balance Equation................................................................................... 79 4.4.4 Final Charge Balance Equation........................................................................... 80 4.4.5 Concentration of Ionic Species............................................................................ 81 4.4.6 Iodine Re-evolution............................................................................................. 84 5.0 Example Calculation Results....................................................................................... 85 5.1 Atmospheric Dispersion Factors.......................................................................... 85 5.1.1 Offsite Dispersion Factors................................................................................... 87 5.1.2 Control Room and Technical Support Center Dispersion Factors....................... 92 5.2 Design Basis Source Terms................................................................................ 92 5.3 Example Core Damage Source Term Selection Process.................................... 93 5.4 Example Severe Accident Analysis..................................................................... 95 5.5 Representative Severe Accident Results............................................................ 98 5.6 Example Containment Aerosol Transport and Removal.................................... 100 5.7 Example Core Damage Event Radiological Consequences............................. 104 5.8 Core Damage Source Term Sensitivity Analysis............................................... 105 5.8.1 General Sensitivity Analysis Methodology......................................................... 105 5.8.2 Application to Core Damage Event................................................................... 106 5.8.3 Sensitivity Analysis Conclusions........................................................................ 117 5.9 Post-Accident pHT............................................................................................. 118 6.0 Summary and Conclusions........................................................................................ 125 6.1 Criteria for Establishing Applicability of Methodologies..................................... 125 6.1.1 Criteria for Atmospheric Dispersion Factors...................................................... 125 6.1.2 Criteria for Core Radionuclide Inventory........................................................... 126 6.1.3 Criteria for Control Room Modeling................................................................... 126 7.0 References................................................................................................................... 127 7.1 Source Documents............................................................................................ 127 7.2 Referenced Documents..................................................................................... 127 Appendix A. Regulatory Assessment of Design-Basis and Beyond-Design-Basis Source Terms................................................................................................... 133

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC viii TABLES Table 1-1.

Abbreviations......................................................................................................... 5 Table 1-2.

Definitions.............................................................................................................. 9 Table 2-1.

Summary of applicable events to the NuScale design........................................ 12 Table 3-1.

Example NuScale parameters for core radionuclide inventory............................ 25 Table 3-2.

Offsite and control room breathing rates (m3/sec)............................................... 30 Table 3-3.

Control room occupancy factors.......................................................................... 30 Table 3-4.

Example control room characteristics.................................................................. 32 Table 4-1.

Meteorological statistics from data set in Figure 4-1(Reference 7.2.23)............. 44 Table 4-2.

Meteorological statistics from data set in Figure 4-1 and test case..................... 51 Table 4-3.

Site meteorological statistics............................................................................... 55 Table 4-4.

Radionuclide groups............................................................................................ 58 Table 4-5.

Summary of aerosol parameter ranges............................................................... 61 Table 4-6.

STARNAUA experimental benchmarking results................................................. 67 Table 4-7.

Test geometry...................................................................................................... 71 Table 4-8.

Radionuclide group molecular mass multipliers.................................................. 76 Table 4-9.

Dissociation constants of assumed acids and bases.......................................... 79 Table 4-10.

Concentration equations of included chemical species....................................... 82 Table 4-11.

Concentration equations of boric acid ionic species............................................ 83 Table 5-1.

Time-interval relative concentrations for selected site......................................... 89 Table 5-2.

Ratio of selected relative concentration to true 90th percentile............................ 91 Table 5-3.

Selected meteorological data.............................................................................. 91 Table 5-4.

Example offsite atmospheric relative concentration (X/Q) values....................... 92 Table 5-5.

Example control room atmospheric dispersion factors........................................ 92 Table 5-6.

Example dose results for design-basis source terms........................................... 93 Table 5-7.

Spectrum of example surrogate accident scenario cases considered for creation of CDST................................................................................................. 95 Table 5-8.

Comparison of release timing and magnitudes of example surrogate accident scenario cases...................................................................................... 99 Table 5-9.

Example accidents for aerosol simulation........................................................ 100 Table 5-10.

Summary of key parameters from all cases...................................................... 103 Table 5-11.

Summary of example aerosol removal results.................................................. 104 Table 5-12.

Summary of example RADTRAD case results.................................................. 105 Table 5-13.

Summary of sampled input assumed for sensitivity analysis............................ 107 Table 5-14.

Key control room dose input rankings and bias directions................................ 109 Table 5-15.

Key low population zone dose input rankings and bias directions.................... 109 Table 5-16.

Key aerosol inputs for low population zone dose rankings and bias directions........................................................................................................... 114 Table 5-17.

Key aerosol concentration input rankings and bias directions........................... 114 Table 5-18.

Direction of bias to maximize dose and minimize aerosol removal................... 116 Table 5-19.

Summary of example pHT results for calculations performed at 25 degrees C.......................................................................................................... 118 Table 5-20.

Summary of example results for baseline calculation with increasing temperatures..................................................................................................... 119 Table A-1 Summary of Pertinent Requirements................................................................ 135

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC ix FIGURES Figure 3-1.

Flowchart of accident radiological calculation process........................................ 15 Figure 4-1.

Cumulative frequency distributions of predicted to observed concentration ratios for the Murphy-Campe (RG 1.145), and revised models (Reference 7.2.23)................................................................................................................. 43 Figure 4-2.

Bias in RG 1.145 model concentration predictions (Reference 7.2.23)............... 45 Figure 4-3.

Bias in ARCON96 concentration predictions (Reference 7.2.23)........................ 45 Figure 4-4.

Comparison of ARCON96 concentration predictions with observed values (Reference 7.2.23).............................................................................................. 47 Figure 4-5.

Comparison of ARCON96 concentration estimates with observed values in the building surface data set (Reference 7.2.23)............................................. 47 Figure 4-6.

Ratios of predicted to observed concentrations for ARCON96 (Reference 7.2.23)................................................................................................................. 48 Figure 4-7.

Variation of low speed diffusion coefficient increments as function of distance (Reference 7.2.23)................................................................................ 49 Figure 4-8.

Variation of high speed diffusion coefficient Increments as function of distance (Reference 7.2.23)................................................................................ 50 Figure 4-9.

Cumulative frequency distributions of predicted concentrations for PAVAN and ARCON96 methodologies............................................................................ 52 Figure 4-10.

Ratio of PAVAN to ARCON96 versus distance (data from Figure 4-9)................ 53 Figure 4-11.

Ratio of PAVAN to ARCON96 versus distance (site data)................................... 54 Figure 4-12.

Calculated and measured suspended aerosol concentrations in Test LA 4........ 68 Figure 4-13.

Calculated and measured suspended aerosol concentrations in Test LA 6........ 68 Figure 4-14.

Calculated and measured suspended aerosol concentrations in Test AB 5........ 69 Figure 4-15.

Calculated and measured suspended aerosol concentrations in Test AB 7........ 69 Figure 4-16.

Benchmark Case 1 CsOH suspended concentration.......................................... 71 Figure 4-17.

Benchmark Case 2 CsOH suspended concentration.......................................... 72 Figure 4-18.

Iodine re-evolution versus pH (Reference 7.2.52)............................................... 84 Figure 5-1.

Map of each surface data site in the selected EPA dataset................................. 86 Figure 5-2.

Markup of site layout with analytical offsite distances overlaid............................ 88 Figure 5-3.

Histogram of calculation results at 33 meters...................................................... 90 Figure 5-4.

Histogram of calculation results at 122 meters.................................................... 90 Figure 5-5.

Example surrogate accident scenario case 2 short-term RPV and CNV pressures............................................................................................................. 95 Figure 5-6.

Example surrogate accident scenario case No. 2 long-term RPV and CNV pressures............................................................................................................. 96 Figure 5-7.

Example surrogate accident scenario case 2 RPV and CNV collapsed liquid levels.......................................................................................................... 96 Figure 5-8.

[Reserved]........................................................................................................... 96 Figure 5-9.

[Reserved]........................................................................................................... 96 Figure 5-10.

Example surrogate accident scenario case 2 representative containment temperatures....................................................................................................... 97 Figure 5-11.

Example surrogate accident scenario case 2 release fractions from fuel........... 97 Figure 5-12.

Example surrogate accident scenario case No. 2 release fractions into containment......................................................................................................... 97 Figure 5-13.

Baseline case aerosol concentration and removal............................................ 101

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 Licensing Topical Report

© Copyright 2019 by NuScale Power, LLC x

Figure 5-14.

Baseline case aerosol aerodynamic mass-median diameter............................ 102 Figure 5-15.

Comparison of aerosol concentration for all example cases versus time.......... 103 Figure 5-16.

Comparison of aerosol removal rate for example cases versus time................ 104 Figure 5-17.

Example control room dose trace plot (constant aerosol)................................. 110 Figure 5-18.

Example low population zone dose trace plot (constant aerosol)..................... 111 Figure 5-19.

Example control room dose sensitivity rankings (constant aerosol).................. 112 Figure 5-20.

Example low population zone dose sensitivity rankings (constant aerosol)...... 112 Figure 5-21.

Low population zone dose trace plot................................................................. 115 Figure 5-22.

Aerosol concentration trace plot........................................................................ 115 Figure 5-23.

The pHT of the coolant over a 30 day time period............................................. 119 Figure 5-24.

Effect of elevated temperature on pHT.............................................................. 120 Figure 5-25.

Sensitivity of pHT to boron concentration........................................................... 121 Figure 5-26.

Sensitivity of pHT to cesium hydroxide.............................................................. 122 Figure 5-27.

Sensitivity of pHT to nitric acid and hydrochloric acid........................................ 123 Figure 5-28.

Sensitivity of pHT to the mass of liquid coolant in containment......................... 124

Accident Source Term Methodology TR-0915-17565-NP Rev. 3

© Copyright 2019 by NuScale Power, LLC 1

Abstract This NuScale topical report describes the methodology used for establishing the source terms and radiological consequences for a spectrum of accidents. In instances where significant differences between the NuScale small modular reactor design and a large light water reactor cause the methodology to depart from existing regulatory guidance, these departures are justified.

A methodology for establishing the NuScale iodine spike design basis source term (DBST) and core damage source term (CDST), which together meet the intent of 10 CFR 52.47(a)(2)(iv), is presented in this report. The CDST associated aerosol transport and iodine re-evolution assessment methodologies are also presented. Approval is sought for application of STARNAUA aerosol modeling software for NuScales range of post-accident containment conditions and the assumption that no iodine decontamination factor limit should be applied to natural aerosol removal phenomenon in the NuScale containment. Approval is also sought for the use of ARCON96 for establishing offsite atmospheric dispersion factors. This topical report is not intended to provide final CDST isotopic inventory values, dose values, atmospheric dispersion factors, or final values of any other associated accident source term evaluation; rather, example values for the various evaluations are provided for illustrative purposes in order to aid the readers understanding of the context of the application of these methodologies.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3

© Copyright 2019 by NuScale Power, LLC 2

Executive Summary This NuScale Power, LLC (NuScale) topical report describes a generalized methodology for developing accident source terms and performing the corresponding radiological consequence analyses. The methodology is conservative for developing accident source terms. Key unique features of the NuScale methodology are the use of ARCON96 for offsite atmospheric dispersion factors, the use of an iodine spike design basis source term (DBST) and a core damage source term (CDST) that together meet the intent of 10 CFR 52.47(a)(2)(iv), and the utilization of STARNAUA containment aerosol transport code in the range of NuScales containment conditions.

For the calculation of offsite atmospheric dispersion factors, current industry practice is to utilize the PAVAN code and methodology that is directly based upon the guidance presented in Regulatory Guide (RG) 1.145 (Reference 7.2.7). PAVAN is conservative, especially at shorter distances, but the large distances typically utilized for offsite radiological consequence analysis have allowed for PAVAN to be a sufficient tool for other applicants. For the calculation of control room atmospheric dispersion factors, current industry practice is to utilize the ARCON96 code and methodology that is based upon the guidance presented in RG 1.194 (Reference 7.2.8).

NuScale has smaller offsite distances to consider in offsite radiological consequence calculations than traditional large Light Water Reactors (LWR) and therefore investigated the use of ARCON96 instead of PAVAN to more accurately establish offsite atmospheric dispersion factors. NuScale determined ARCON96 is applicable and conservative for NuScales intended use of the code. NuScale is seeking NRC approval for this methodology.

10 CFR 52.47(a)(2)(iv) (Reference 7.2.1) requires nuclear power reactor design certification applicants to evaluate the consequences of a fission product release into the containment assuming the facility is being operated at the maximum licensed power level.

10 CFR 52.47(a)(2)(iv) also requires nuclear power reactor design certification applicants to describe the design features that are intended to mitigate the radiological consequences of an accident. Following the approach of the 2012 Nuclear Energy Institute (NEI) position paper on small modular reactor (SMR) source terms (Reference 7.2.20), NuScale refers to the scenario envisioned in footnote 3 of 10 CFR 52.47(a)(2)(iv) as the maximum hypothetical accident (MHA).

Although the NuScale design may preclude any credible design basis accident scenario that results in substantial core meltdown and fission product release, it is recognized that the analysis of an appropriately determined MHA is necessary to demonstrate that a facility's design features and site characteristics provide an acceptable level of protection to the public and control room operators.

10 CFR 52.47(a)(2)(iv) has historically been linked to a large break loss-of-coolant accident (LOCA) in large LWRs. However, NuScale has no large diameter primary coolant system piping, therefore a large break LOCA cannot physically be postulated as the basis for this analysis. The NuScale design has design-basis events (DBEs) that result in primary coolant entering the containment, and the iodine spike DBST described in Section 3.2.6 is used to bound the radiological consequences of these events. A beyond-design-basis core damage event (CDE) described in Section 4.2, with an associated CDST composed of a set of key parameters derived from a spectrum of accident sequences, is also postulated. The design-basis iodine

Accident Source Term Methodology TR-0915-17565-NP Rev. 3

© Copyright 2019 by NuScale Power, LLC 3

spike DBST and the beyond-design-basis CDST are each assessed against the radiological criteria of 10 CFR 52.47(a)(2)(iv). If both the design basis iodine spike DBST and the beyond-design-basis CDST analyses show acceptable dose results, 10 CFR 52.47(a)(2)(iv) is met. The analysis of the beyond-design-basis CDST against the acceptance criteria of 10 CFR 52.47(a)(2)(iv) provides reasonable assurance that, even in the extremely unlikely event of a severe accident, the facilitys design features and site characteristics provide adequate protection of the public.

Calculations associated with the radiological consequences of the CDE take credit for the natural aerosol removal mechanisms inherent in the NuScale containment design. The STARNAUA containment aerosol transport and removal code was benchmarked against experimental data and was shown to be appropriate for modeling aerosol removal in the CDE analysis associated with the post-accident NuScale containment conditions. Consistent with RG 1.183, NuScale utilizes the assumption that no iodine decontamination factor limit should be applied to natural aerosol removal phenomenon for modeling removal in containment. Through sensitivity analysis on the modeling parameters utilized as input to the STARNAUA code, it was shown that the wide range of valid aerosol modeling parameters utilized were of equal or less importance for the CDE radiological consequence results compared to other key modeling parameters. This insight should reduce the relative importance of the particular aerosol modeling inputs selected for the CDE analysis.

Example calculations are provided in this report to demonstrate applicability of the methodology and to aid the readers understanding of the application of these methodologies. The application referencing this topical report is expected to present design-specific calculations utilizing the methodologies presented herein.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3

© Copyright 2019 by NuScale Power, LLC 4

1.0 Introduction 1.1 Purpose The purpose of this report is to define and justify the methodology for assessing the source terms and radiological consequences of accidents. NuScale requests NRC approval that the assumptions, codes, and methodologies presented in this report are technically acceptable and consistent with current regulations.

1.2 Scope This report describes assumptions, codes, and methodologies utilized to calculate the radiological consequences of accidents. NuScale seeks approval for the methodology for establishing the iodine spike design basis source term (DBST) and the beyond-design-basis core damage source term (CDST). The iodine spike DBST and the beyond-design-basis CDST are each assessed against the radiological criteria of 10 CFR 52.47(a)(2)(iv). If both the design basis iodine spike DBST and the beyond-design-basis CDST analyses show acceptable dose

results, 10 CFR 52.47(a)(2)(iv) is met. NuScale also seeks approval of the beyond-design-basis core damage event (CDE) associated aerosol transport and iodine re-evolution assessment methodologies. Approval is requested for application of STARNAUA aerosol modeling software to NuScales range of post-accident containment conditions and the assumption that no iodine decontamination factor limit should be applied to natural aerosol removal phenomenon in the NuScale containment. Approval is also requested for the use of ARCON96 for establishing offsite atmospheric dispersion factors instead of PAVAN.

This topical report is not intended to provide final CDST isotopic inventory values, final dose values, final atmospheric dispersion factors, or final values of any other associated accident evaluation; rather, example values for the various evaluations are provided for illustrative purposes. Radiological consequence dose results and comparisons with regulatory acceptance criteria are provided for illustration to aid the readers understanding of the context of the application of these methodologies.

A summary of specific positions for which NuScale is seeking approval in this topical report are as follows:

1. Treatment of the CDE, postulated as a major accident for purposes of site analysis pursuant to Footnote 3 of 10 CFR 52.47(a)(2)(iv), as a beyond-design-basis event for the NuScale design.
2. Use of ARCON96 methodology for the calculation of offsite atmospheric dispersion factors.
3. ((2(a),(c)
4. Release timing values associated with the surrogate accident scenario with the minimum time to core damage are taken as the CDST release timing values.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 5

5. Representative (median) release fractions from fuel into containment from the spectrum of surrogate accident scenarios are taken as the CDST release fractions.
6. Use of SAND2011-0128 radionuclide groups for the CDST.
7. STARNAUA is appropriate for modeling natural removal of containment aerosols for the NuScale design.
8. Utilizing thermal-hydraulic data associated with the surrogate accident scenario with the minimum time to core damage is appropriate for use in STARNAUA.
9. No maximum limit on iodine decontamination factor for natural removal of containment aerosols.
10. ((
}}2(a),(c)
11. Utilizing the iodine spiking assumptions of RG 1.183 is appropriate.
12. Utilizing the iodine decontamination factor assumptions of RG 1.183 for the fuel handling accident is appropriate.
13. With respect to accident analysis, it is appropriate to neglect the small secondary side volume that could contain activity from primary to secondary leakage for the NuScale design.
14. For pHT values of 6.0 or greater, the amount of iodine re-evolution that could occur between pHT values of 6.0 and 7.0 is negligible and not included in the dose calculation.
15. Containment shine of the radiation in the containment airspace through the containment vessel, reactor pool water, and then through the reactor building walls or ceiling to the environment is negligible for the NuScale design.

1.3 Abbreviations Table 1-1. Abbreviations Term Definition ALWR advanced light water reactor AST alternative source term Bq Becquerel (unit of radioactivity) CDE core damage event CDST core damage source term Ci curie (unit of radioactive decay) Ci microcurie (1.0E-06 Ci) (unit of radioactive decay) cfm cubic feet per minute (unit of flow)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 6 Term Definition CNV containment vessel COL combined license CR control room CVCS chemical and volume control system DBE design basis event DBST design basis source term DCF dose conversion factor DHRS decay heat removal system DSRS Design-Specific Review Standard EAB exclusion area boundary ECCS emergency core cooling system ERF emergency response facility ESP early site permit FGR Federal Guidance Report FHA fuel handling accident GDC General Design Criteria HVAC heating ventilation and air conditioning ICRP International Commission on Radiological Protection JFD joint frequency distribution lbm pound mass (unit of mass) LOCA loss-of-coolant accident LODC loss of DC power LPZ low population zone LWR light water reactor MHA maximum hypothetical accident MSLB main steam line break MSIV main steam isolation valve MWth mega-watts thermal (unit of thermal power)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 7 Term Definition NCDC National Climatic Data Center NIST National Institute of Standards and Technology NEI Nuclear Energy Institute NPM NuScale Power Module NRC Nuclear Regulatory Commission (United States) NWS National Weather Service pHT concentration of H+ ion on a logarithmic scale (temperature dependent) PF partition factor PRA probabilistic risk assessment PRCC partial rank correlation coefficient PWR pressurized water reactor RCS reactor coolant system REA rod ejection accident rem Roentgen equivalent man (unit of dose, see TEDE) RG Regulatory Guide RPV reactor pressure vessel RRV reactor recirculation valve RVV reactor vent valve scfh standard cubic feet per hour (unit of flow) scfm standard cubic feet per minute (unit of flow) SG steam generator SGTF steam generator tube failure SMR small modular reactor SRP Standard Review Plan Sv sievert (unit of radiation dose) TEDE total effective dose equivalent TMI Three Mile Island

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 8 Term Definition

atmospheric dispersion factor in units of seconds per cubic meter

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 9 Table 1-2. Definitions Term Definition Core damage Assumed to occur at the onset of clad ballooning for the purposes of source term release timing. Core damage event A special event (beyond design basis) with radionuclides from core damage released into an intact containment postulated as the maximum hypothetical accident to enable deterministic evaluation of the response of a facilitys engineered safety features. Core damage source term The source term associated with the core damage event that is composed of a set of key parameters derived from a spectrum of surrogate accident scenarios. Design basis The entire range of conditions for which a facility is designed in accordance with established design criteria and for which damage to the fuel and release of radioactive material are kept within authorized limits. Design basis accident A postulated accident that a nuclear facility must be designed and built to withstand without loss to the systems, structures, and components necessary to ensure public health and safety. Design basis event Postulated events used in the design to establish the acceptable performance requirements for the structures, systems, and components. Design basis source term Radionuclide release associated with a design basis accident. DE I-131 Dose equivalent I-131 is the concentration of I-131 (Ci/gm) that alone would produce the same dose when inhaled as the combined activities of iodine isotopes I-131, I-132, I-133, I-134, and I-135 present. DE Xe-133 Dose equivalent XE-133 is the concentration of Xe-133 (Ci/gm) that alone would produce the same acute dose to the whole body as the combined activities of noble gas nuclides Kr-85m, Kr-85, Kr-87, Kr-88, Xe-133, and Xe-135 present. Iodine spike design basis source term The bounding source term associated with design-basis events that result in primary coolant entering the containment postulated to enable deterministic evaluation of the response of a facility's engineered safety features. Loss-of-coolant accident Those postulated accidents that result in a loss of reactor coolant at a rate in excess of the capability of the reactor makeup system from breaks in the reactor coolant pressure boundary, up to and including a break equivalent in size to the double-ended rupture of the largest pipe of the reactor coolant system. Maximum hypothetical accident NuScale follows the approach of the 2012 NEI position paper on SMR source terms (Reference 7.2.20) by referring to the scenario described in footnote 3 of 10 CFR 52.47(a)(2)(iv) as the maximum hypothetical accident (MHA).

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 10 Term Definition Single release phase A single release phase of fission products, as opposed to distinct gap release and early in-vessel release phases. Surrogate accident scenario A postulated event that results in core damage with subsequent release of appreciable quantities of fission products into an intact containment, that serves as a surrogate to the large break loss-of-coolant accident with a substantial meltdown of the core typically evaluated by light water reactors as the maximum hypothetical accident.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 11 2.0

Background

NuScale Power, LLC (hereafter, NuScale) distinguishes between design-basis source terms (DBSTs) and the beyond-design-basis core damage source term (CDST). The design-basis source terms include standard deterministic design-basis accidents that are similar to those of large light water reactors (LWRs) such as: main steam line break (MSLB), rod ejection accident (REA), fuel handling accident (FHA), steam generator tube failure (SGTF) and small primary coolant line break outside containment. NuScales DBST methodology is consistent with Regulatory Guide (RG) 1.183 methodology. NuScale follows the guidance of RG 1.183 for its approach to DBSTs, except where significant differences exist between the NuScale design and large LWRs. These differences and NuScales design specific approach are presented in this report. A NuScale-unique iodine spike DBST and CDST together meet the intent of 10 CFR 52.47(a)(2)(iv) (Reference 7.2.1). 10 CFR 52.47(a)(2)(iv) requires nuclear power reactor design certification applicants to evaluate the consequences of a fission product release into the containment assuming the facility is being operated at the maximum licensed power level, and describe what design features are intended to mitigate the radiological consequences of an accident. Footnote 3 of 10 CFR 52.47(a)(2)(iv) states: The fission product release assumed for this evaluation should be based upon a major accident, hypothesized for purposes of site analysis or postulated from considerations of possible accidental events. These accidents have generally been assumed to result in substantial meltdown of the core with subsequent release into the containment of appreciable quantities of fission products. NuScale follows the approach of the 2012 Nuclear Energy Institute (NEI) position paper on small modular reactor (SMR) source terms (Reference 7.2.20) by referring to the scenario described in footnote 3 of 10 CFR 52.47(a)(2)(iv) as the MHA. The MHA has historically been linked to a large break LOCA in large LWRs. As described in the NEI position paper (Reference 7.2.20), as SMRs have no large diameter primary coolant system piping, a large break LOCA cannot physically be postulated as the basis for the standard review plan (SRP1) Section 15.6.5 analysis of site dose in comparison to 10 CFR 52.47 limits. Therefore, a large break LOCA is not appropriate as the basis for calculating source terms for NuScale. The NuScale design has design-basis events (DBEs) that result in primary coolant entering an intact containment and the iodine spike DBST described in Section 3.2.6 is used to bound the radiological consequences of these events. Although the NuScale design may preclude any credible accident scenario that results in substantial core meltdown and fission product release, NuScale recognizes that the analysis of an appropriately determined MHA is necessary to demonstrate that 1 Within the context of this report, reference to the SRP is also meant to account for NuScale design-specific review standards (DSRS).

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 12 engineered safety features (ESF) provide an acceptable level of protection to the public and control room operators. As stated in RG 1.183, the design basis accidents were not intended to be actual event sequences, but rather, were intended to be surrogates to enable deterministic evaluation of the response of a facilitys engineered safety features. Therefore, a beyond-design-basis core damage event (CDE) described in Section 4.2, with an associated CDST composed of a set of key parameters derived from a spectrum of surrogate accident scenarios, is also postulated. The design-basis iodine spike DBST and the beyond-design-basis CDST are each assessed against the radiological criteria of 10 CFR 52.47(a)(2)(iv). If both the design-basis iodine spike DBST and the beyond-design-basis CDST analyses show acceptable dose results, 10 CFR 52.47(a)(2)(iv) is met. The analysis of the beyond-design-basis CDST against the acceptance criteria of 10 CFR 52.47(a)(2)(iv) provides reasonable assurance that, even in the extremely unlikely event of a severe accident, the facilitys design features and site characteristics provide adequate protection of the public. The methodology evaluates other design basis accidents for radiological consequences. Table 2-1 is a summary of applicable events for the NuScale design. The table includes the event, the NuScale DSRS or SRP section that addresses the event, the section of RG 1.183 that discusses the event input parameters and assumptions, and the primary source of radiation for the event. Table 2-1. Summary of applicable events to the NuScale design Event DSRS or SRP RG 1.183 Appendix* Primary Source of Radiation Core damage event 15.0.3 A damaged fuel Fuel handling accident 15.7.4 B Rod ejection accident 15.4.8 H Main steam line break 15.1.5 E coolant activity (with iodine spiking) Steam generator tube failure 15.6.3 F Primary coolant line break 15.6.2 n/a Iodine spike DBST** 15.6.5 n/a

  • Note: Appendices C, D, and G were not included because they are not applicable to the NuScale design.
    • Note: The iodine spike DBST is not an event, but rather a bounding source term associated with DBEs that result in primary coolant entering the containment.

In addition to the requirements of 10 CFR 52.47 and the guidance of RG 1.183, further guidance is provided in NUREG-1465, RG 1.145, RG 1.194, RG 1.195, and the NuScale DSRS. The NuScale DSRS Section 15.0.3 specifically summarizes the general and specific acceptance criteria for evaluating radiological considerations. These criteria include consideration of atmospheric dispersion and the radiological consequences at the

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 13 exclusion area boundary (EAB), low population zone (LPZ), control room (CR), and technical support center. Additionally, other accident radiological considerations include post-accident monitoring and access shielding, among others. See Appendix A for a summary of how pertinent requirements are met without a design-basis core damage event. See the NuScale Accident Source Term Regulatory Framework white paper (Reference 7.1.4) for additional background information. 2.1 Regulatory Requirements The following regulatory requirements and guidance documents are relevant to the design basis accident radiological evaluations described in this report: 10 CFR 50, Appendix A, GDC 19, Control Room 10 CFR 52.47, Contents of Applications; Technical Information NUREG-1465, Accident Source Terms for Light Water Nuclear Power Plants, Revison 0, February 1995 RG 1.183, Alternate Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors, Revision 0, July 2000 NuScale Draft DSRS, Section 15.0.3, Design Basis Accident Radiological Consequence Analyses for NuScale SMR Design, June 2015 NuScale Draft DSRS, Section 15.1.5, Steam System Piping Failures Inside and Outside of Containment, June 2015 NUREG-0800, Section 15.4.8, Spectrum of Rod Ejection Accidents (PWR), Revision 3, March 2007 NUREG-0800, Section 15.6.2, Radiological Consequences of the Failure of Small Lines Carrying Primary Coolant Outside Containment, Revision 2, June 1981 NUREG-0800, Section 15.6.3, Radiological Consequences of Steam Generator Tube Failure, Revision 2, July 1981 NUREG-0800, Section 15.7.4, Radiological Consequences of Fuel Handling Accidents, Revision 1, July 1981 RG 1.145, Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants, Revision 1, February 1983 RG 1.194, Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants, Revision 0, June 2003 RG 1.195, "Methods and Assumptions for Evaluating Radiological Consequences of Design Basis Accidents at Light-Water Nuclear Power Reactors," Revision 0, May 2003 SECY-94-302, Source Term Related Technical and Licensing Issues Pertaining to Evolutionary and Passive Light-Water-Reactor Designs, December 1994

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 14 2.2 Basis for Treating Core Damage Event as a Beyond Design Basis Event NuScale treats the core damage event as a beyond-design-basis event. This approach is based on attributes of the NuScale design as compared to the history of the 10 CFR 52.47(a)(2)(iv) dose evaluation requirement and related developments in NRC policy and guidance. These developments, as summarized below, indicate it can be acceptable to consistently treat a core damage event, which is a severe accident, as a beyond-design-basis event for a design such as NuScale's. In SECY-03-0047 (Reference 7.2.16), staff recognized that the classic LWR siting evaluation based on an in-vessel core melt may not be applicable to non-LWR designs. Staff recommended the use of scenario-specific source terms derived from DBEs defined for the plant, allowing credit to be given for unique aspects of plant design (i.e., performance-based). SECY-05-0006 (Reference 7.2.17) discussed broadening that same framework to include future LWRs. In SECY-90-016 (Reference 7.2.28), staff stated severe core damage accidents should [not] be design basis accidents (DBA) in the traditional sense that DBAs have been treated in the past, in that features provided for only severe accident mitigation were not required to meet typical safety-related requirements. Because the MHA is a severe core damage accident, its treatment as a design basis accident for the purposes of evaluating offsite doses pursuant to 10 CFR 52.47(a)(2)(iv) limits implementation of the NRC position on equipment survivability established by SECY-90-016 and the associated Staff Requirements Memorandum. In 10 CFR 50.67 rulemaking (Reference 7.2.29), the NRC stated that there is no regulatory requirement for a specific source term for reactors to be licensed in the future. In the federal register notice associated with the 10 CFR Part 100 rulemaking (Reference 7.2.32), the NRC stated It is worth noting that events having the very low likelihood of about 10-6 per reactor year or lower have been regarded in past licensing actions to be incredible, and as such, have not been required to be incorporated into the design basis of the plant. A scenario resulting in core damage for the NuScale Power Module (NPM) design would entail multiple failures of safety-related equipment. No electrical power or operator action is required to prevent or mitigate a design-basis accident. Passive fail-safe safety systems, a small core size, and a containment vessel (CNV) that is partially submerged in the ultimate heat sink result in the frequency of a potential core damage in an NPM being orders of magnitude lower than the safety goals, and core damage sequences with frequencies that are orders of magnitude lower than those considered "incredible" in past licensing actions. Dominant NPM risk contributors involve one or more common cause failures of redundant components, such as 3 of 3 emergency core cooling system (ECCS) reactor vent valves or 4 of 4 decay heat removal system actuation valves, and common cause initiating events, such as failure of 4 of 4 DC buses. From these observations, it follows that a severe accident scenario resulting in core melt for the NuScale design constitutes a beyond-design-basis event, and the consideration and mitigation of dose consequences for such an event should be treated accordingly.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 15 3.0 Methodology Overview This topical report presents the methodology utilized to perform the radiological calculations associated with the DBSTs and CDST, with a focus on the following NuScale specific methodology: iodine spike DBST atmospheric dispersion core damage source term containment aerosol generation and removal post-accident pHT A flowchart of the radiological consequence calculation process is provided in Figure 3-1, each component of which is discussed in detail in this section. Figure 3-1. Flowchart of accident radiological calculation process

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 16 3.1 Software 3.1.1 SCALE 6.1/TRITON/ORIGEN-S SCALE 6.1 modular code package, developed by Oak Ridge National Laboratory, is used for development of reactor core and primary coolant fission product source terms. Specifically, the TRITON and ORIGEN-ARP analysis sequences of the SCALE 6.1 modular code package, and ORIGEN-S, run as a standalone module, are used to generate radiation source terms for the NuScale fuel assemblies and primary coolant (Reference 7.2.25). The aforementioned software has been used in the evaluation of operating large LWRs. The operating environment, nuclear fuel and structural materials in the NuScale design are expected to be similar to, or bounded by, that in large pressurized water reactors (PWR). 3.1.1.1 TRITON As described in the SCALE manual (Reference 7.2.25), the TRITON sequence of the SCALE code package is a multipurpose control module for nuclide transport and depletion, including sensitivity and uncertainty analysis. TRITON can be used to generate problem-and exposure-dependent cross sections as well as perform multi-group transport calculations in one-dimensional, two-dimensional, or three-dimensional geometries. The ability of TRITON to model complex fuel assembly designs improves transport modeling accuracy in problems that have a spatial dependence on the neutron flux. In this case, TRITON is used to generate burnup-dependent cross sections for NuScale fuel assemblies for subsequent use in the ORIGEN-ARP depletion module. 3.1.1.2 ORIGEN (ORIGEN-ARP and ORIGEN-S) Reference 7.2.25 describes ORIGEN-ARP as a SCALE depletion analysis sequence used to perform point-depletion and decay calculations with the ORIGEN-S module using problem-and burnup-dependent cross sections. ORIGEN-S nuclear data libraries containing these cross sections are prepared by the ARP module using interpolation in enrichment and burnup between pre-generated nuclear data libraries containing cross section data that span the desired range of fuel properties and operating conditions. The ORIGEN-ARP sequence produces calculations with accuracy comparable to that of the TRITON sequence with a savings in problem setup and computational time as compared to repeated use of TRITON. Many variations in fuel assembly irradiation history can be modeled. For depletion calculations involving NuScale fuel assemblies, the ORIGEN-S nuclear data libraries are generated by the TRITON sequence, as described in the previous Section 3.1.1.1. 3.1.2 NARCON The calculation of both onsite and offsite atmospheric dispersion factors for design basis accidents and the CDE is performed with NARCON. NARCON is the NuScale version of ARCON96 (Reference 7.2.24). NARCON is equivalent to ARCON96 with the exceptions of input/output edit differences ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 17 ARCON96 implements the guidance provided in RG 1.194 (Reference 7.2.8). The code implements a building wake dispersion algorithm; an assessment of ground level, building vent, elevated and diffuse source release modes; use of hour-by-hour meteorological observations; sector averaging and directional dependence of dispersion conditions. The code also implements a Gaussian diffusion model for the 0 to 8 hour period. NuScale uses ARCON96 for various time periods at the EAB and the outer boundary of the LPZ as well as the control room and technical support center. Justification for utilizing ARCON96 for offsite locations, as opposed to PAVAN, is provided in Section 4.1. 3.1.3 RADTRAD RADTRAD is used to estimate radionuclide transport and removal of radionuclides and dose at selected receptors for the various design-basis accidents and the CDE (Reference 7.2.31). Given the radionuclide inventory, release fractions and timing, RADTRAD estimates doses at offsite locations, i.e., the EAB and LPZ, and inside the control room and technical support center. As material is transported through the containment, the user can account for natural deposition that may reduce the quantity of radioactive material. Material can flow between buildings, from buildings to the environment, or into the control rooms through filters, piping or other connectors. An accounting of the amount of radioactive material retained due to these pathways is maintained. Decay and in-growth of daughters can be calculated over time as material is transported. 3.1.4 MELCOR MELCOR is used to model the progression of severe accidents through modeling the major systems of the plant and their generally coupled interactions (Reference 7.2.13). Specific use relevant to the application of the CDST includes the following: thermal-hydraulic response of the primary coolant system and containment vessel core uncovering, fuel heatup, cladding oxidation, fuel degradation and core material melting and relocation aerosol generation in-vessel and ex-vessel hydrogen production and transport fission product release (aerosol and vapor) and transport impact of engineered safety features on thermal-hydraulic and radionuclide behavior 3.1.5 NRELAP5 NRELAP5 is NuScales proprietary system thermal-hydraulic computer code used in engineering design and analysis. It has been developed for best-estimate transient simulation of LWR coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for LOCAs and operational transients. A generic modeling approach is used that permits simulating a variety of

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 18 thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. NRELAP5 was developed at NuScale, with RELAP5-3D© v.4.1.3 as the initial baseline. RELAP5-3D© v.4.1.3 was procured from the Idaho National Laboratory through a commercial grade dedication process. Upon dedication, the RELAP5-3D© v.4.1.3 code was renamed NRELAP5 and further developed by NuScale. 3.1.6 STARNAUA Aerosol transport and removal calculations are provided by the program STARNAUA. STARNAUA is an aerosol transport and removal software program that was developed by Polestar Applied Technology, Inc., a company later purchased by WorleyParsons. STARNAUA is an enhanced version of NAUAHYGROS and was developed by Polestar for performing aerosol removal calculations in support of work to develop and apply a realistic source term for advanced and operating LWRs. It models natural removal of containment aerosols by sedimentation and diffusiophoresis, and considers the effect of hygroscopicity (growth of hygroscopic aerosols due to steam condensation on the aerosol particles) on aerosol removal. In developing STARNAUA, Polestar enhanced NAUAHYGROS by adding a model for thermophoresis, a model for spray removal, and the capability to directly input steam condensation rate or condensation heat transfer rate, and total heat transfer rate such as would be provided from an external containment thermal hydraulics code calculation. This software was developed for the purpose of performing aerosol removal calculations to apply in realistic source terms for advanced and operating LWRs. This realistic source term methodology is consistent with existing industry practice used for large passive LWR design certification. 3.1.7 pHT The Fortran program developed by NuScale to calculate post-accident aqueous molar concentration of hydrogen ions (pHT) is called pHT. This program calculates pHT utilizing the methodology described in Section 4.4. This program takes inputs for initial boron and lithium concentrations, the total core inventory of iodine and cesium, the integrated photon dose to the containment and total dose to the coolant, the initial mass of coolant, the mass of coolant, and the temperature of the coolant. The program then calculates the coolant pHT as a function of time. 3.1.8 MCNP6 MCNP6 is utilized for evaluating potential shine radiological exposures, or doses, to operators within the control room following a radiological release event. Direct shine, sky-shine, and shine from all possible filters are evaluated. MCNP is a general-purpose tool used for neutron, photon, electron, or coupled neutron, photon, and electron transport (Reference 7.2.27). MCNP treats an arbitrary three-dimensional configuration of materials in geometric cells bounded by first-and second-degree surfaces and fourth-degree elliptical tori. The code is well-suited to performing fixed source calculations of the type documented herein.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 19 MCNP uses continuous energy cross-section data. For photons, the code accounts for incoherent and coherent scattering, the possibility of fluorescent emission after photoelectric absorption, and absorption in electron-positron pair production. Electron and positron transport processes account for angular deflection through multiple Coulomb scattering, collisional energy loss with optional straggling, and the production of secondary particles including x-rays, knock-on and Auger electrons, bremsstrahlung, and annihilation gamma rays from positron annihilation at rest. 3.2 Overview of Design Basis Source Terms 3.2.1 Rod Ejection Accident NuScale utilizes the REA methodology guidance enumerated in Appendix H of RG 1.183. Appendix H of RG 1.183 states that no radiological consequences analysis is required if no fuel damage is indicated in the analysis and the accident is bounded by other events. For the purposes of this report, the REA methodology is described assuming the results from the failure of one full assembly in order to establish a methodology in the event that fuel failures are postulated in a future application. If fuel failure does occur, then the radiological consequence analysis considers the REA event with two different release paths, as described below. Containment release path:

1. A control rod ejection occurs, resulting in a rapid positive reactivity insertion.
2. A portion of the fuel rods are damaged by either cladding breach or melt failure modes.
3. All of the activity released from the fuel is instantaneously and homogenously mixed in the containment atmosphere.
4. The containment leaks as described in Section 3.3.7.

Primary system release path:

1. A control rod ejection occurs, resulting in a rapid positive reactivity insertion.
2. A portion of the fuel rods are damaged by either cladding breach or melt failure modes.
3. All of the activity released from the fuel is instantaneously and homogenously mixed in the primary system.
4. Primary coolant leaks into both steam generators at the maximum leak rate allowed by design basis limits. The leakage continues until the reactor is shut down and depressurized and the primary and secondary systems are at an equal pressure.
5. Activity is released to the environment through the condenser until isolation is achieved.
6. Leakage through the secondary isolation valves (main steam and feedwater) occurs in the reactor building until the reactor is shut down and depressurized. No credit is taken for any source term reduction within the reactor building.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 20 The following is a summary of the assumptions used from Appendix H of RG 1.183: containment iodine chemical form of 95 percent cesium iodide, 4.85 percent elemental iodine, and 0.15 percent organic iodide primary system iodine chemical form of 97 percent elemental iodine and 3 percent organic iodide no reduction or mitigation of noble gas radionuclides released from the primary system density for leak rate conversion: 62.4 pound mass (lbm)/ft3 3.2.2 Fuel Handling Accident The methodology for determining FHA radiological consequences is based on the guidance provided in Appendix B of RG 1.183 and Section 15.7.4 of the SRP. The explicit guidance enumerated in Appendix B of RG 1.183, as updated by Regulatory Issue Summary (RIS) 2006-04 (Reference 7.2.11) item 8, is followed. The methodology assumes failure of all the fuel rods in one irradiated fuel assembly occurs. As presented in Section 3.3.8 of this report, the NuScale reactor pool has a minimum depth above the damaged fuel greater than the minimum 23 foot depth specified as the basis for the iodine decontamination factor in Reference 7.2.11. The following is a summary of the assumptions used from Appendix B of RG 1.183: radionuclides considered include xenon, krypton, halogen, cesium, and rubidium overall effective iodine decontamination factor of 200 for the pool no reduction or mitigation of noble gas radionuclides released from the fuel release to the environment over a two hour period The standard activity release period of two hours is used for the dose assessment. This period is the standard assumption provided in Section 4.1 of Appendix B of RG 1.183, which states that For fuel handling accidents postulated to occur within the fuel building, the following assumptions are acceptable to the NRC staff: The radioactive material that escapes from the fuel pool to the fuel building is assumed to be released to the environment over a 2-hour time period. 3.2.3 Main Steam Line Break outside Containment Radiological consequences of the main steam line break outside containment accident are calculated based on the guidance provided in Appendix E of RG 1.183. The NuScale methodology for calculating the radiological consequences of this event follow the explicit guidance enumerated in Appendix E of RG 1.183. This radiological consequence analysis considers the main steam line break event with two different initial iodine concentrations, one based on a pre-incident iodine spike and

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 21 the other based on a coincident iodine spike. A description of the scenario evaluated is summarized as follows:

1. A main steam line break occurs in one of the two main steam lines.
2. For each of the iodine spiking scenarios, the iodine and noble gas coolant activity is calculated based on the maximum concentrations allowed by primary coolant system design basis limits.
3. Primary coolant leaks into the secondary side of the intact steam generators at the maximum leak rate allowed by design basis limits. The leakage continues until the primary system pressure is less than the secondary system pressure.
4. A time-dependent release is modeled that effectively releases the activity directly to the environment through the break.
5. The non-faulted steam line continues to release a small quantity of radiation through valve leakage.

The following is a summary of the assumptions used from Appendix E of RG 1.183: coincident iodine spiking factor: 500 duration of coincident iodine spike: 8 hr density for leak rate conversion: 62.4 lbm/ft3 iodine chemical form of 97 percent elemental iodine and 3 percent organic iodide no reduction or mitigation of noble gas radionuclides released from the primary system 3.2.4 Steam Generator Tube Failure Radiological consequences of the steam generator tube failure accident are calculated based on the guidance provided in Appendix F of RG 1.183 and Section 15.6.3 of the SRP. The NuScale methodology for calculating the radiological consequences of this event follows the explicit guidance enumerated in Appendix F of RG 1.183. This radiological consequence analysis considers the steam generator tube failure event with two different initial iodine concentrations, one based on a pre-incident iodine spike and the other based on a coincident iodine spike. A description of the scenario evaluated is summarized as follows:

1. A steam generator tube failure occurs in one of the two steam generators.
2. For each of the iodine spiking scenarios, the iodine and noble gas coolant activity is calculated based on the maximum concentrations allowed by design basis limits.
3. Primary coolant flows into the secondary coolant through the failed steam generator tube at a rate and duration defined by the transient analysis.
4. Primary coolant leaks into the secondary side of the intact steam generators at the maximum leak rate allowed by primary coolant system design basis limits. The

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 22 leakage continues until the primary system pressure is less than the secondary system pressure.

5. A time-dependent release is modeled that effectively releases the activity directly to the environment through the break.
6. Once secondary system isolation occurs, both steam lines continue to release small quantities of radiation through valve leakage into the reactor building which is assumed to flow directly into the environment without any source term reduction.

The following is a summary of the explicit assumptions used from Appendix F of RG 1.183: coincident iodine spiking factor: 335 duration of coincident iodine spike: 8 hr density for leak rate conversion: 62.4 lbm/ft3 iodine chemical form: 97 percent elemental iodine and 3 percent organic iodide no reduction or mitigation of noble gas radionuclides released from the primary system 3.2.5 Failure of Small Lines Carrying Primary Coolant outside Containment Failure of small lines carrying primary coolant outside containment is not an event specifically addressed in RG 1.183 and Section 15.6.2 of the SRP only provides general guidance for this event. Therefore, the methodology, including the iodine spiking assumptions, developed by NuScale for this event is similar to the main steam line break and steam generator tube failure. An event-specific transient analysis is used to define the time-dependent release of activity. This radiological consequence analysis considers the chemical and volume control system (CVCS) break event with a coincident iodine spike. The following is a description of the postulated scenario evaluated for this event.

1. A failure of CVCS piping occurs outside the containment vessel inside the reactor building.
2. The primary coolant contains iodine and noble gas radionuclides.
a. Coincident iodine spike: The primary coolant inside the reactor vessel initially contains no iodine. Over a period of eight hours, iodine is transported from inside the fuel rods to the coolant at a rate 500 times the normal release rate. Coolant inside the CVCS equipment and piping is at the maximum concentrations allowed by design basis limits.
b. Noble gas: The primary coolant contains the maximum concentrations allowed by design basis limits.
3. Before containment isolation occurs, primary coolant flows out the reactor vessel through the break at a rate and duration calculated by the transient analysis. This

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 23 results in a time-dependent release of activity to the reactor building which is modeled for conservatism as a direct release to the environment through the break.

4. After containment isolation, primary coolant leaks through one containment isolation valve (other in-series valve is assumed to fail) at the maximum leak rate allowed by design basis limits. The leakage continues until the reactor is brought to shutdown conditions. The activity from this leak path is also assumed to flow directly to the environment with no mitigation or reduction by any intervening structures.
5. Available primary coolant in the CVCS equipment (heat exchangers, filters, etc.) and piping flows out of one or the other side of the break. The coolant is at the maximum activity concentration allowed by design basis limits.
6. Once the reactor is completely shut down and depressurized, all releases through valve leakage stops.

The following is a summary of the explicit assumptions used from Appendix E (main steam line break) of RG 1.183. coincident iodine spiking factor: 500 duration of coincident iodine spike: 8 hr iodine chemical form: 97 percent elemental iodine and 3 percent organic iodide no reduction or mitigation of noble gas radionuclides released from the primary system 3.2.6 Iodine Spike Design Basis Source Term The iodine spike DBST is composed of a set of key parameters, derived from the assumption of a generic failure occurring inside the CNV, which results in the release of all primary coolant from the reactor coolant system (RCS) to the CNV. The iodine spike DBST is a surrogate that bounds the radiological consequences of a spectrum of events that result in primary coolant entering an intact containment. Primary coolant with radionuclide concentrations at the design basis limits enters the containment and 100 percent of the radionuclides within 100 percent of the primary coolant are assumed to be present in the containment. This assumption is conservative because some amount of primary coolant (at least the amount required to cover the core) would remain in the reactor pressure vessel (RPV) and, therefore, the radionuclides associated with that primary coolant would not be available in the CNV for release. Additionally, this is conservative because some amount of the radionuclides would remain in the primary coolant at the bottom of the CNV, but the analysis assumes all the radionuclides are available to leak out of the CNV as vapor. Because the iodine spike DBST is not a specific event, nor an extension of a specific event, there is no thermal-hydraulic analysis associated with the iodine spike DBST. This radiological consequence analysis considers the iodine spike DBST with two different initial iodine concentrations, one based on a pre-incident iodine spike and the other based on a coincident iodine spike. A coincident iodine spiking factor of 500 is

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 24 utilized because this is the largest coincident iodine spiking factor recommended for any event in RG 1.183. The duration of the coincident iodine spike is assumed to be eight hours. The pre-incident iodine spike considered for this analysis is derived as shown in Section 3.3.2 of this report. Aerosol removal is not credited. An iodine chemical form of 97 percent elemental iodine and 3 percent organic iodide is arbitrarily assumed because RADTRAD requires the input, but this assumption has no impact on results. No reduction or mitigation of noble gas radionuclides released from the primary coolant is assumed. Spiking effects may occur for radionuclides besides iodines. However, any potential spiking of radionuclides besides iodine is implicitly accounted for by conservative treatments of the iodine spike DBST. For example, the assumed instantaneous event-time-zero release of the entire primary coolant inventory results in doses expected to be several times larger than a more realistic graduated release of a primary coolant mass less than the entire primary coolant mass. This approach is consistent with the available regulatory guidance, which does not prescribe the spiking of radionuclides besides iodines. Regulatory Guide 1.183, Appendix I, addresses assumptions for evaluating radiation doses for equipment qualification purposes. Regulatory Position 4 therein notes the possibility that another design basis accident (i.e., non-core melt events) may be more limiting than the "design basis LOCA" (i.e., the core melt source term event) for the purposes of equipment qualification for some components. In these cases, RG 1.183 recommends the use of the applicable assumptions of Appendices B through H otherwise applicable to the dose consequence evaluations for the event in question, which do not include spiking of any radionuclides besides iodines. A key use of the iodine spike DBST is to establish the radiation environment for a design basis accident inside containment, as other events are expected to be more limiting with respect to dose consequences outside containment. Therefore, NuScale concludes the existing guidance of RG 1.183, which establishes the assumptions of Appendices B through H are adequate for a similar use (developing design-basis equipment qualification radiation environments), is appropriate to follow with respect to the iodine spike DBST. Accordingly, spiking of radionuclides besides iodine is not explicitly considered in the iodine spike DBST methodology.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 25 3.3 General Methodology and Assumptions 3.3.1 Core Radionuclide Inventory In order to establish the amount of radionuclides that could be released, the reactor core radionuclide inventory must be established. The isotopic inventories of fuel assemblies are calculated using the SCALE 6.1 package described in Section 3.1.1. This methodology includes an assumption for maximum activity for each isotope and is used in the radiological consequence analysis. Isotopic concentrations are based on the detailed geometry of a fuel assembly, rated power plus uncertainty, maximum possible assembly average exposure, and a range of U235 enrichments. Table 3-1 includes a summary of example parameters that could be used for determining radionuclide inventory. The isotopic inventory is calculated at a number of time steps in the fuel cycle, the number of which is calculated based on the recommendations of the modeling guidelines of Reference 7.2.25. For each isotope, the maximum curie content of any time step is used as the activity for that isotope at the beginning of any event. Table 3-1. Example NuScale parameters for core radionuclide inventory Description Example Value Core Power Uncertainty 2 percent Assembly Average Exposure 62 GWd/MT Evaluated U235 enrichments range 1.5 percent - 5 percent Number of time steps in fuel cycle 40 For each radiological consequence calculation in which the fuel assembly is the source term, the activity of a single fuel assembly ( Assembly iA ) for each isotope may then be utilized. The total released activity ( leased iARe ) is determined by the release fractions defined for the event and isotope, expressed as i i Assembly i i A A

x

x

x = Factor Decon. Fraction Release Assemblies of Number Peaking Radial Released Eq 3-1 Two options (deterministic and as-loaded) are provided for modeling the total irradiation history of the evaluated fuel assemblies in a reactor core; either of which are acceptable. Each specific application referencing this methodology must specify which option is utilized.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 26 A deterministic option is a treatment of exposure such that it is assumed that all fuel assemblies in the core are irradiated to the maximum allowed assembly exposure (62 GWd/MT as an example). Thus, a full core inventory is a simplified single batch core design used for analysis purposes in which it is assumed that the fuel is irradiated at constant full power plus uncertainty until the maximum exposure is reached. This is an alternative to an as-loaded option, which is a best-estimate approach with respect to uniquely loaded fuel batches. With this option, isotopic inventories are given at the end of irradiation for several fuel assembly types, for each cycle (a multi-batch core design). In this approach, a whole-core inventory is calculated through the weighted sum of the values for each fuel assembly type. As noted above, each specific application that references this methodology must specify in its analyses which option was utilized. 3.3.2 Primary Coolant Radionuclide Inventory For the radiological consequence analysis, the radioactive concentrations in the primary coolant system are set at the maximum dose equivalent values permitted by design basis limits. Actual isotopic concentrations are derived from the nominal coolant concentrations calculated and then scaled to the design basis limit maximum. In addition, a release rate factor from the fuel for the coincident iodine spike scenario is applied as specified in SRP Section 15.6.2. With appropriate unit conversions, concentration of each isotope may be calculated by Equation 3-2. ( ) Ci Ci gm lbm lbm ft ft V Ci gm Ci i i 6 3 3 10 59 453

=

Eq 3-2 where: ( )i Ci = Total activity for isotope i i gm Ci

= Concentration for isotope i V = Volume of primary coolant, ft3 
= Density of primary coolant, lbm/ft3 The isotopic concentrations equivalent to the design basis limit DE I-131 is determined from the nominal concentration using dose conversion factors from Reference 7.2.38 as described by Equation 3-3. 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 27 131

x

=

I i Nom i DE i DCF DCF gm uCi gm uCi Eq 3-3 where: i = index for isotopes i DCF : = Dose Conversion Factor for isotope i 131

I DCF

= Dose Conversion Factor for isotope I-131 DE i

gm uCi

= Concentration of isotope i adjusted for DE I-131 Nom i

gm uCi

= Nominal concentration of isotope i For the pre-incident iodine spike scenario, the same technique is utilized to calculate the primary coolant design basis limit maximum source terms for a dose equivalent I-131 at the elevated pre-incident limit. In both spiking scenarios, the noble gas concentrations are calculated using the same technique scaled to the design basis limit for DE Xe-133 and the dose conversion factors from Reference 7.2.39 as defined by 133

x

=

Xe i Nom i DE i DCF DCF gm uCi gm uCi Eq 3-4 In order to model a coincident iodine spike as specified in RG 1.183, the primary coolant iodine concentration is estimated using a spiking model that assumes that the iodine release rate from the fuel rods to the primary coolant increases to a value [event-specific] times greater than the release rate corresponding to the iodine concentration at the equilibrium value (Reference 7.2.2).

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 28 At equilibrium the production and removal of iodine is equal, by definition. Therefore, the equilibrium iodine release rate, (i.e., iodine production rate) may be calculated by determining the iodine removal rate. The removal rate is a function of the reactor coolant system (RCS) removal, CVCS decontamination, and the natural radioactive decay process. For conservatism, no decontamination of the CVCS is credited, as doing so would result in a lower production rate. Therefore, for each isotope i, the isotopic production or removal rate i is the sum of the two removal mechanisms of RCS removal, and radioactive decay decay i,

, expressed algebraically in the form of ,=,=,+, Eq 3-5 where,, is derived from contributions of CVCS letdown flow and allowable RCS operational leakage. The equilibrium production rate (Ri) is then the activity of each isotope (Ai) multiplied by the appearance rate of the isotope, as in = x (,+,) Eq 3-6 For all isotopes, the removal rate of iodine by RCS removal is based on the flow rate and the total mass of coolant (M) in the primary system. Applying the appropriate unit conversions results in an expression of the form ,() =

1

7.481 60 Eq 3-7 The decay rate of each isotope is determined from the half-lives 2 1T of each isotope, using 2 1 2 ln T decay i =

Eq 3-8 Applying the above equations to each isotope of iodine results in the production rates and total activities at the end of the 8 hour spiking period. The release rate from the fuel to primary coolant is calculated such that 99 percent of the activity available for release from the fuel is released to the coolant in the eight-hour duration of the concurrent iodine spike utilizing an exponential release model. t oe A A

= Eq 3-9

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 29 where, AO = Initial Activity in Fuel A = Final Activity in Fuel

= Removal Rate (vol/hr) t = Removal Time (hr) = 8.0 hr Solving Eq 3-9 for the removal rate and including an arbitrary fuel volume of 500 ft3. The volume of the fuel is arbitrary, given that 99 percent of the activity will be released irrespective of the fuel volume. The reason for the assumption of 99 percent is that as an exponential release model, 100 percent will never be reached. The arbitrary fuel volume is used to convert the release rates into units of cubic feet per minute (cfm), which is the only input allowed by RADTRAD. Converting into units of cfm results in cfm hr ft hr 8.4 min 60 500 8

%) 1 ln( 3 =

Eq 3-10 The total activity in the fuel eligible to be released from the fuel into the coolant due to spiking Ci is based on the event-specific spiking factor SF multiplied by the equilibrium production rate Ri, as in i i R SF C

= Eq 3-11 Thus, the iodine spike can be modeled as a flow rate from the fuel to the coolant for the eight-hour duration using Eq 3-10, with the total activity for each isotope in the fuel eligible for release calculated from Eq 3-11. 3.3.2.1 Secondary Coolant Activity Large PWR designs contain a large volume of secondary system water on the shell side of the steam generator heat exchanger. Through primary-to-secondary leakage limits and monitoring by sampling, this water volume contains levels of iodine that are limited operationally. The NuScale design is the opposite, in that the shell side of the heat exchanger is the primary coolant and the tube side is the secondary coolant. The ratio of the secondary coolant that could contain iodine to the primary coolant is small (approximately 1 percent) and therefore the potential source of radioactivity in the secondary coolant that is typically accounted for in PWR dose analysis is neglected in NuScales design. 3.3.3 General Dose Analysis Inputs The dose analysis program RADTRAD uses a combination of tables and numerical models of source term transport phenomena to determine the time-dependent dose at user-specified locations for a given accident scenario. The model also provides the decay chain and dose conversion factor tables needed for the dose calculation. The user provides the atmospheric relative concentrations X/Q for offsite locations and the control

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 30 room. In addition, the breathing rates and the control room occupancy factors are provided by the user. 3.3.3.1 Source Term Release Fraction and Timing for Dose Analysis Isotopic activities derived for input to radiological consequence analysis are described in Section 3.3.1. Section 3.3.1 also describes how release fraction and timing effects for RADTRAD calculations are addressed by factoring the core radionuclide inventory with release fractions. A detailed description of fission product release fraction and timing information generated from MELCOR is provided in Section 4.2.3. 3.3.3.2 Atmospheric Dispersion Factors X/Q, Breathing Rates, and Occupancy Factors Atmospheric dispersion factor X/Q inputs to RADTRAD are derived as described in Section 5.1. Control room and offsite breathing rate inputs to RADTRAD, consistent with RG 1.183 (Reference 7.2.2), are summarized in Table 3-2. Table 3-2. Offsite and control room breathing rates (m3/sec) Time (Hr) CR EAB LPZ 0 - 8 3.50E-04 3.50E-04 3.50E-04 8 - 24 1.80E-04 1.80E-04 24 - 720 2.30E-04 2.30E-04 Control room occupancy factor inputs to RADTRAD, consistent with RG 1.183 (Reference 7.2.2), are summarized in Table 3-3. Table 3-3. Control room occupancy factors Time (Hr) Occupancy (percent) 0 - 8 100 8 - 24 60 24 - 720 40 3.3.3.3 Flow Rates Values assumed for the tabular flow rate and timing inputs to RADTRAD are based on habitability system capacities. The final values are expected to be evaluated in the application that references this report. 3.3.3.4 Dose Conversion Factors Consistent with RG 1.183 (Reference 7.2.2), dose conversion factors from Environmental Protection Agency (EPA) Federal Guidance Report No. 11 and EPA Federal Guidance Report No. 12 (References 7.2.38 and 7.2.39, respectively) are used for dose analysis.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 31 3.3.4 General Dose Analysis Assumptions 3.3.4.1 Control Room Ventilation Design The final control room ventilation design is expected to be provided in the application that references this report. A representative design for the control room ventilation system was used to confirm the methodology assumptions. The key design features assumed for this representative example design are summarized as follows: The nonsafety related normal control room ventilation is isolated by a control system once a sufficiently high source of radioactivity is measured An emergency source of pressurized air provides clean air for 72 hours After 72 hours of emergency operation, the normal control room ventilation system is used again The control room is habitable during a loss of offsite power as the emergency mode will be automatically activated if this occurs Control ventilation is designed to minimize in-leakage For the example calculations provided in Section 5.0 of this report, the following modeling assumptions are defined in Table 3-4.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 32 Table 3-4. Example control room characteristics 3.3.4.2 Control Room Dose Mitigation Equipment No credit is taken for the use of personal protective equipment such as protective beta radiation resistant clothing, eye protection, or self-contained breathing apparatus. Similarly, no credit is taken for prophylactic drugs such as potassium iodide pills. 3.3.4.3 Reactor Building Decontamination ((

}}2(a),(c) 3.3.4.4 Pre-Accident Coolant Radiation Levels For events in which the source of radiation is from damaged fuel, it is assumed that the primary and secondary coolant radiation levels are zero prior to the accident level with the exception of pre-incident iodine spiking scenarios required for evaluation. This assumption is in accordance with RG 1.183 (Reference 7.2.2) that prescribes the source term assumptions and isotopes to be used for each event. In particular, the fuel releases are assumed to occur and mix instantaneously within the reactor coolant system. For events in which the source of radiation is from primary coolant, the primary coolant radiation levels prescribed by RG 1.183 are utilized.

3.3.4.5 Control Room Exhaust The control room exhaust is equal to the total inlet flow in both the normal and emergency operating modes. For the pressure to remain in equilibrium, an equal amount of air must be exhausted. This assumption takes credit for air escaping through doors when open or other potential leakage pathways, such as penetrations in the control room envelope. Description Units Value Control Room Isolation Time min 1 Control Room Envelope Volume ft3 170,000 Control Room Emergency Flow Rate cfm 100 Control Room Normal Flow Rate cfm 495 Control Room Emergency Duration hr 72 Control Room Unfiltered Ingress/Egress cfm 5 Control Room Unfiltered In-leakage cfm 10

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 33 3.3.4.6 Radiation Shine Radiological Consequences Per Section 4.2.1 of RG 1.183 (Reference 7.2.2), the following contributions of radiation shine to the control room dose are included in the methodology: radioactive material in systems and components inside or external to the control room envelope, for example, radionuclides collected in filters sky shine from an external radioactive plume released from the facility direct shine from airborne fission product gases within the reactor building and contamination of structural surfaces within the reactor building The calculated shine dose from the bounding event is applied to all events rather than specifically calculating the shine dose for each event. For the event that results in the largest activity released into the reactor building and control room, the radionuclide activities calculated by RADTRAD at key time intervals throughout the event are utilized as input into ORIGEN-S and MCNP models. The photon source terms are defined according to a user-supplied energy group structure, which consists of a series of energy bins over which average source strengths are calculated. In the ORIGEN-S calculations, an eighteen-group energy structure is adopted for the photon spectra. MCNP calculations include explicit models of the control room and surrounding reactor building in conjunction with a defined radiation source. The source configurations considered include airborne fission product gases within the environs of the reactor building, radionuclide contamination of structural surfaces within the reactor building, and radionuclide contamination within the control room external filter. In each calculation model, the exposure to an operator within the control room is evaluated using the cell (volume) tally feature of the MCNP code. The MCNP calculations employ the continuous energy cross section data libraries from the associated ENDF/B-VII nuclear data libraries and employ photon flux-to-dose conversion factors that are used to evaluate the exposure to an operator within the control room as a function of the operators position. The photon flux-to-dose conversion factors employed are based on International Commission on Radiological Protection (ICRP)-74 (Reference 7.2.61). Shine through the containment vessel, reactor pool water, and then through the reactor building walls or ceiling to the environment is assumed to be negligible for the NuScale design. More than half of the containment vessel is assumed to be submerged in the reactor pool for the majority of the thirty day evaluation period. This water would provide significant shielding, with further shielding provided by multiple feet of reinforced concrete walls and the concrete roof of the aircraft impact resistant reactor building. 3.3.4.7 Reactor Building Pool Boiling Radiological Consequences An extended loss-of-offsite power event is expected to result in the decay heat from the reactors and the spent fuel to heat up the spent fuel pool and eventually cause the reactor pool to boil. The dose contribution of the pool boiling, such as would be

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 34 postulated to occur in the NuScale reactor pool in the event of an extended loss of power to the pool heat removal system, is accounted for in the following manner. The methodology assumes that the reactor pool water would contain radionuclides primarily from routine refueling operations of a number of modules over a period of time. A lifetime equilibrium tritium concentration is assumed based on estimated boron concentrations in the reactor coolant and radwaste recycling associated with the pool cleanup system. Isotopes considered are those isotopes deemed important contributors to dose, and that are predicted to occur in the reactor pool, specifically the isotopes of H-3, I-131, Cs-137 and Sr-90. The radioactive source term for this event are the nuclides released in the reactor pool water from refueling operations. These values are multiplied by the cumulative pool water volume released during boil off. ((

}}2(a),(c) 3.3.4.8 Parent and Daughter Isotopes Consistent with RG 1.183 (Reference 7.2.2), the RADTRAD decay and daughtering modeling option is used to include progeny from the decay of parent radionuclides that are significant with regard to radiological consequences and the released radioactivity.

The calculated total effective dose equivalent (TEDE) dose is thus the sum of the committed effective dose equivalent from inhalation and the deep dose equivalent from external exposure from all tracked isotopes. 3.3.4.9 Two-Hour Sliding Window RADTRAD determines the maximum two-hour TEDE by calculating the postulated dose for a series of small time increments and performing a "sliding" sum over the increments of successive two-hour periods. The time increments appropriately reflect the progression of the accident to capture the peak dose interval between the start of the event and the end of radioactivity release. 3.3.4.10 Effluent Plume Depletion Consistent with RG 1.183 (Reference 7.2.2), the RADTRAD model does not include corrections for depletion of the effluent plume by deposition on the ground. 3.3.4.11 Direct Release Path The methodology presented in this topical report assumes that there is no direct release path from the reactor building or turbine generator building to the control room or technical support center. This hypothetical flow path would bypass the environment and would not consider atmospheric dispersion.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 35 The methodology assumed an example design with a connection between the control building and reactor building. In this example a tunnel connects the reactor building to the control building. Between the reactor building and control room envelope, it is assumed that there are multiple doors, multiple airlocks, and administrative controls on ingress and egress through these doors. The two turbine generator buildings are assumed physically separate from the control building with no interconnecting passageway. The validity of the assumption that radiation could not credibly be transported through this pathway in a postulated design basis accident or the CDE is expected to be confirmed by the application that references this topical report. 3.3.5 Offsite Dose Calculation As defined in Reference 7.2.31, the dose to a hypothetical individual is calculated with RADTRAD using user specified X/Qs and the amount of each nuclide released during the exposure period. The air immersion dose from each nuclide,, in an environmental compartment is calculated as: = (/), Eq 3-12 where = air immersion (cloudshine) dose due to nuclide in the environment compartment (Sievert (Sv)) , = Federal Guidance Report No. 11 and Federal Guidance Report No. 12 air immersion (cloudshine) dose conversion factor for nuclide as discussed in Section 3.3.3.4 (Svm3/Becquerel(Bq)s) X/Q = user-provided atmospheric relative concentration (s/m3) A = released activity of nuclide n (Bq) The activity is related to the number of atoms of nuclide as: = Eq 3-13 Where is the radiological decay constant for the nuclide. The inhalation dose from each nuclide,, is calculated as: = (/), Eq 3-14 where = inhalation dose commitment due to nuclide in the environment compartment (Sv) BR = user-provided breathing rate (m3/s) DCF, = user-provided inhalation dose conversion factor for nuclide as discussed in Section 3.3.3.4 (Sv/Bq) 3.3.6 Control Room Dose Calculation Per Reference 7.2.31, control room dose is calculated with RADTRAD based on the time-integrated concentration in the control room compartment using the user input atmospheric dispersion factors and breathing rates. The air immersion dose in the control room is calculated as:

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 36 = (),/x Eq 3-15 where () is the instantaneous concentration of radionuclide in the compartment and occupancy factor. The Murphy-Campe (Reference 7.2.58) geometric factor relates the dose from an infinite cloud to the dose from a cloud of volume as: = 1173 Eq 3-16 The inhalation dose in the control room is: = ()() Eq 3-17 3.3.7 Containment Leakage For both DBST and CDST radiological consequence analyses, with the exception of the failure of small lines carrying primary coolant outside containment analysis, the containment is assumed to leak at the design basis limit leak rate for 24 hours and then at half of the design basis limit leak rate thereafter. As described in Section 3.2.5 of this report, the failure of small lines carrying primary coolant outside containment analysis conservatively assumes the maximum leak rate allowed by design basis limits until the reactor is shut down and depressurized, even if that time is beyond 24 hours. ((

}}2(a),(c) 3.3.8 Fuel Handling Accident Decontamination The methodology for determining the radiological consequences of a FHA assumes that the NuScale reactor pool (or spent fuel pool depending on the location of the FHA) has a minimum water depth above the damaged fuel greater than the 23-foot depth specified in RG 1.183. An elemental decontamination factor of 285, an organic decontamination factor of 1, and an overall effective decontamination factor of 200 are assumed per RG 1.183 as updated by RIS 2006-04 (Reference 7.2.11) item 8.

3.3.9 Iodine Spiking The NRCs results of the initial screening of Generic Issue (GI) 197 (Reference 7.2.34) describes the phenomenon of iodine spiking observed in operating reactors. After a core power or primary system pressure transient, the iodine concentration in the reactor coolant may increase to a value many times its equilibrium concentration level, followed by a gradual decay back down to a lower level. Iodine spiking occurs when a change in reactor power, temperature, and/or pressure results in the transport of dissolved iodine

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 37 compounds out of failed fuel rods and into the primary coolant. After reaching peak concentrations, the iodine is then gradually removed by the reactor coolant cleanup systems, radioactive decay, and release to the environment. All known iodine spiking models are built on an assumed physical causative scenario of a fuel rod with a defect. During power operation, iodine collects on the surfaces of the fuel pellets and internal cladding surface; likely as cesium iodide or another water-soluble salt. However, during operation, the internal free volume of the defective fuel rod is steam-blanketed, and relatively little iodine is transported out to the reactor coolant. If the reactor is shut down, or if power is reduced in a power transient, liquid water will enter the fuel pellet-to-cladding gap volume, dissolving any soluble iodine compounds, which then can readily diffuse out of the cladding defect. Similarly, a pressure transient could force liquid water in or out of the defective fuel rod, thereby transporting iodine into the bulk primary coolant. It should be noted that, if there were no cladding defects in the core, then according to this model the specific activity of iodine on the cladding surface would drop to zero, under both equilibrium and non-equilibrium conditions. The presence of traces of uranium on the outside of the cladding left over from manufacture of the fuel, complicates the model. Iodine produced from fission of a trace uranium atom would not be expected to contribute to spiking, since it is already outside of the cladding, but would contribute to the equilibrium specific activity in the coolant. NuScale intends to follow the current regulatory guidance with respect to modeling iodine spiking as the justifications made in GI-197 are applicable to NuScale fuel and reactor coolant system operating conditions. GI-197 discusses the adequacy of current industry practice iodine spiking modeling in detail, focusing on SGTF for a large PWR plant in which it is assumed that isolation will take up to two hours. GI-197 also discusses that iodine spiking assumed to occur over 8 hours may be approximated by a more severe two hour spike. Thus, for this type of event in which the spiking duration is proportional with the time required for isolation, NuScale utilizes the iodine spiking assumptions of RG 1.183. 3.3.10 Steam Generator Decontamination The helical coil steam generators of the NuScale design are different than that of a large PWR because the primary coolant is on the outside of the steam generator tubes. As a result, there is not a bulk water volume in which decontamination could easily occur. ((

}}2(a),(c)

((

}}2(a),(c) 3.3.11 Removal in Piping and Main Condenser

((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 38 4.0 NuScale Unique Methodology 4.1 Atmospheric Dispersion NuScale anticipates the possibility of applicants referencing this topical report postulating an exclusion area boundary (EAB) and low population zone (LPZ) at the site boundary, which is estimated to be in the range of 80 to 400 meters. This range of distances is shorter than the boundaries associated with standard nuclear power plants, which may range from 800-6000 meters. This postulated LPZ and EAB is expected to be in the near-vicinity of buildings. For these conditions, in which the LPZ is near buildings, the industry-standard methodology for the calculation of offsite relative dose concentrations is less robust than the methodology for calculation of onsite relative dose concentrations. The methodology presented in this report uses ARCON96 for offsite and control room radiological consequence analyses. The PAVAN methodology, based upon the guidance presented in RG 1.145 (Reference 7.2.7), over-predicts relative dose concentrations in the vicinity of buildings for the limiting case. This conclusion is consistent with Reference 7.2.23, which states: In the mid-1980s, the staff of the U.S. Nuclear Regulatory Commission (NRC) felt that its guidance to licensees related to calculating atmospheric concentrations of radionuclides and toxic chemicals in the vicinity of buildings was overly conservative. ARCON96 methodology, based on RG 1.194 (Reference 7.2.8), is more accurate than PAVAN for predicting atmospheric dispersions in the vicinity of buildings for the limiting case, while still producing predictions with conservative margins. As illustrated in Sections 4.1.3 and 4.1.4, this difference in accuracy is most evident at shorter distances. This reasoning was the basis of the development of ARCON96. The models purposes are directly relevant to the NuScale offsite relative concentration calculation, as described in the following sections. 4.1.1 PAVAN Detailed information regarding PAVAN methodology can be found in the PAVAN Users Manual (Reference 7.2.22). PAVAN methodology is based upon the guidance presented in RG 1.145 (Reference 7.2.7), which describes four regulatory positions. Position one addresses the calculation of relative concentrations, position two addresses the determination of maximum sector relative concentrations, position three addresses the determination of a five percent overall site relative concentration, and position four concerns the selection of relative concentrations to be used in evaluations. The following is a summary of this guidance. Position one: The meteorological data needed for relative concentration calculations include a joint frequency distribution (JFD) of hourly wind speed, wind direction, and a measure of atmospheric stability for one year. A consecutive 24-month period of onsite meteorological data is expected to be included in an early site permit (ESP) or combined license (COL) application that does not reference an ESP per SRP Section 2.3.3

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 39 (Reference 7.2.14) and RG 1.23 (Reference 7.2.6). Wind direction is classed into 16 separate 22.5-degree sectors. Two-hour relative concentrations are calculated through selective use of Eq 4-1, Eq 4-2, and Eq 4-3 by assuming meteorological data representing 1-hour averages are applicable to the 2-hour period. Eq 4-1 and Eq 4-2 are used to account for building wake effects, and Eq 4-3 is used to account for plume meander. The maximum relative concentration calculated from Eq 4-1 and Eq 4-2 is compared with the relative concentration calculated from Eq 4-3, and the minimum is selected. Eq 4-1 Eq 4-2 Eq 4-3 = relative concentration = downwind distance (meters) = wind-speed category = stability category = lateral dispersion of plume for stability category j at distance x () = vertical dispersion of plume for stability category j at distance x c = mixing volume coefficient in building-wake term (set to 0.5) A = minimum cross-sectional area of the building = meander factor for lateral plume spread Uij(10) = adjusted average wind speed for wind speed and stability Eq 4-4 [Note: The Mij (x) yj (x) term from Eq 4-3 is redefined in Eq 4-4 for downwind distances greater than 800 meters. For downwind distances less than 800 meters, Eq 4-4 is not used.] [ ] { } 1 ) ( ) ( ) 10 ( ) (

+ = cA x x U j i x Q X zj yj ij

{ } 1 ) ( ) ( ) 10 ( 3 ) (

= x x U j i x Q X zj yj ij

{ } 1 ) ( ) ( ) ( ) 10 ( ) (

= x x x M U j i x Q X zj yj ij ij

) ( j i x Q X ) (x yj

) (x M ij [ ] ) 800 ( 1 ) ( ) ( ) ( ) ( yj ij yj yj ij x M x x x M

+ =

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 40 = lateral dispersion of plume at 800 meters Two-hour relative concentrations are calculated for EAB and LPZ distances for each hour of data by assuming meteorological data representing 1-hour averages are applicable to the 2-hour period. An annual average is also calculated for each sector at the LPZ distance and is used in combination with the two-hour relative concentration in order to determine relative concentrations for various intermediate time periods. Position two: Using relative concentrations calculated for each hour of data, a cumulative probability distribution of relative concentrations is constructed for each of the 16 sectors. A plot of relative concentration versus probability of being exceeded is made for each sector and a smooth curve is drawn to form an upper bound of the computed points. For each of the 16 curves, the relative concentration that is exceeded 0.5 percent of the total number of hours in the data set should be selected. The highest of the 16 sector values is defined as the maximum sector X/Q. Maximum sector relative concentrations are calculated for the 0 to 2 hour time period for the EAB. Maximum sector relative concentration for the 0 to 2 hour time period and the intermediate time periods are calculated for the LPZ. Position three: Using relative concentrations calculated for each hour of data, an overall cumulative probability distribution for all directions combined is constructed. A plot of relative concentration versus probability of being exceeded is made, and an upper bound curve is drawn. The two-hour relative concentration that is exceeded five percent of the time should be selected from this curve. In addition, for the LPZ distance, the maximum of the 16 annual average relative concentrations should be used along with the five percent two-hour relative concentration to determine relative concentrations for the intermediate time periods. Position four: The relative concentration for EAB or LPZ distances should be the maximum sector X/Q (position two) or the 5 percent overall site X/Q (position three), whichever is higher. 4.1.2 ARCON96 Detailed information regarding ARCON96 methodology and a description of the technical basis for the code is provided in Reference 7.2.24. The following paragraphs provide a brief summary of relevant sections of this technical basis and information from RG 1.194 (Reference 7.2.8). The meteorological data needed for relative concentration calculations include hourly data of wind speed, wind direction, and a measure of atmospheric stability for one year. A consecutive 24-month period of onsite meteorological data is expected to be included in an ESP or COL application that does not reference an early site permit per SRP Section 2.3.3 and RG 1.23. Relative concentrations are calculated for each hour through use of Eq 4-5 and Eq 4-6. ARCON96 estimates diffusion in building wakes by replacing the and terms in Eq 4-5 with the and terms in Eq 4-6. ) 800 ( yj

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 41 The subscript y indicates horizontal direction and the subscript z indicates the vertical direction. 1: (the low wind speed increment) is the factor that accounts for plume meander. 2: (the high wind speed increment) is the factor that accounts for building wake effects, and is the normal diffusion coefficient. is the distance from the center of the plume

=

0.5

Eq 4-5 Eq 4-6 Intermediate time periods are calculated using different averages of each hourly relative concentration. A cumulative frequency distribution is constructed for each averaging period, and the 95th percentile relative concentration is selected from each, using linear interpolation. These relative concentrations are used to calculate the 95th percentile relative concentration for each standard averaging interval. 4.1.3 Major Differences The following list summarizes the key differences between PAVAN and ARCON96 program methodology, using the information described in Sections 4.1.1 and 4.1.2 of this report. Generally, PAVAN uses a JFD of hourly wind speed, wind direction, and a measurement of stability class, while ARCON96 uses hourly data. PAVAN relies upon selective use of three different equations to account for plume meander and building wake effects, while ARCON96 relies upon one equation that accounts for both factors as a function of wind speed. PAVAN calculates a 99.5th percentile relative concentration for each sector and a 95th percentile relative concentration for the site limit, while ARCON96 only calculates a 95th percentile relative concentration. ((

}}2(a),(c)

PAVAN calculates a relative concentration for each of the 16 direction sectors with only one execution of the code, while ARCON96 calculates a relative concentration for one specified direction sector per code execution. The direction sector can be specified in any direction from the intake to the source when executing ARCON96. NuScale utilizes 16 different 22.5 degree direction sectors for ARCON96 to be 2 2 2 1 2 2 2 2 1 2 z z z z y y y y

+ + =

+ + =

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 42 consistent with PAVAN, which utilizes 16 direction sectors that are each 22.5 degrees. PAVAN assumes a default direction window of 22.5 degrees, while ARCON96 allows a custom input direction window. NuScales methodology is to utilize ((

}}2(a),(c).

As stated above, ARCON96 calculates relative concentrations in one of 16 possible direction sectors at a time, while PAVAN calculates relative concentrations for all 16 direction sectors. Therefore, in order to use ARCON96 for offsite purposes, 16 executions of the code must be performed (one for each direction sector). The NuScale methodology for the use of ARCON96 for offsite purposes assumes a uniform circle where each of the 16 direction sectors is of equal length. ((

}}2(a),(c) 4.1.4 Atmospheric Dispersion Estimates in the Vicinity of Buildings Reference 7.2.23 describes revisions made to the 1995 standard methodology used for estimating relative concentrations in the vicinity of buildings. The revised model later became the industry standard model, and its methodology was used to create ARCON96. The revised model includes corrections to the diffusion coefficients specifically implemented to improve model performance at low wind speeds, where meander and possibly uneven heating of building surfaces may be responsible for increased diffusion and at high wind speeds where turbulence from wakes dominates.

This reference contains a section that validates the revised model through comparison of calculated relative concentrations and observed relative concentrations as illustrated in Figure 4-1. The methodology from RG 1.145 is included in this figure for comparison.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 43 Figure 4-1. Cumulative frequency distributions of predicted to observed concentration ratios for the Murphy-Campe (RG 1.145), and revised models (Reference 7.2.23) Figure 4-1 shows that compared with other NRC models, the revised model has less tendency to over-predict relative concentrations, especially at cumulative frequencies above 40 percent. At ratio cumulative frequencies of 95 percent and greater, as shown in Figure 4-1, RG 1.145 methodology over-predicts relative concentrations by two to three orders of magnitude and the revised model over-predicts relative concentrations by one to two orders of magnitude. The observed relative concentrations were recorded from various experiments. The distances range from 8 to 1200 meters, meteorological condition stability classes range from extremely unstable (1) to extremely stable (7), and the wind speeds range from less than 1 m/s to greater than 10 m/s. Table 4-1 includes other relevant meteorological statistics from the data set. The emphasis on low wind speed, (where low wind speed is assumed to be wind speeds of less than 4 m/s in the context of this report), stable conditions is appropriate because concentrations predicted for these conditions typically provide the limiting case in evaluation of consequences of accidental releases in the vicinity of buildings. Specifically, Reference 7.2.15 shows that the ARCON96 95th percentile relative concentrations are typically associated with wind speeds of 3 to 4 m/s.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 44 Table 4-1. Meteorological statistics from data set in Figure 4-1(Reference 7.2.23) Description Number of points Percentage of set Wind speed < 4 m/s 253 67 Stable atmospheric conditions 208 55 Low wind speed and stable atmospheric conditions 138 36 Total 379 100 (( }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 45 }}2(a),(c) Figure 4-2. Bias in RG 1.145 model concentration predictions (Reference 7.2.23) }}2(a),(c) Figure 4-3. Bias in ARCON96 concentration predictions (Reference 7.2.23) ((

}}2(a),(c)

(( ((

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 46 ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 47 Figure 4-4. Comparison of ARCON96 concentration predictions with observed values (Reference 7.2.23) Figure 4-5. Comparison of ARCON96 concentration estimates with observed values in the building surface data set (Reference 7.2.23)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 48 Figure 4-6. Ratios of predicted to observed concentrations for ARCON96 (Reference 7.2.23) ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 49 Figure 4-7 and Figure 4-8, also taken from Reference 7.2.24, ((

}}2(a),(c)

Figure 4-7. Variation of low speed diffusion coefficient increments as function of distance (Reference 7.2.23)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 50 Figure 4-8. Variation of high speed diffusion coefficient Increments as function of distance (Reference 7.2.23) ((

}}2(a),(c) 4.1.5 PAVAN and ARCON96 Comparison PAVAN, which is based upon RG 1.145 methodology, is the industry-standard software for the calculation of offsite relative concentrations. However, as noted in Section 4.1, the postulated NuScale EAB and outer LPZ boundary distances are in the near vicinity of on-site buildings, and are much shorter than distances associated with a nuclear power plant of standard size. The downwind distances associated with the observed values in Figure 4-1 are in the range of 8 to 1200 meters. This range adequately encompasses the postulated range of the NuScale EAB and LPZ (approximately 80 to 400 meters).

As Figure 4-2 illustrates, the PAVAN methodology over-predicts relative concentrations at low wind speeds. Because of this over-prediction, PAVAN is not a realistic model for a plant with a small LPZ and EAB. This result is consistent with the quote from Reference 7.2.23 provided in Section 4.1 of this report. The guidance referred to in the quote from Reference 7.2.23 is the Murphy-Campe methodology, which is similar to the RG 1.145 methodology with regard to predictive ability. This correlation between RG 1.145 and the Murphy-Campe methodology is shown in Figure 4-1. RG 1.145 methodology over-predicts concentrations more frequently than the Murphy-Campe model. Since the Murphy-Campe methodology is defined as overly conservative in the vicinity of buildings, per Reference 7.2.23, then the RG 1.145 methodology is also assumed to

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 51 over-predict in these same conditions and is not a realistic model for a plant with a small LPZ and EAB. ARCON96, which is based upon the aforementioned revised model, is the industry-standard software for the calculation of control room relative concentrations in the vicinity of buildings. As Figure 4-1 and Figure 4-3 illustrate, the revised model is more accurate than the other models at the limiting case, and its predictions provide sufficient margin. 4.1.5.1 Test Case One: Percentile Comparison ((

}}2(a),(c)

Table 4-2. Meteorological statistics from data set in Figure 4-1 and test case (( }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 52 Figure 4-9. Cumulative frequency distributions of predicted concentrations for PAVAN and ARCON96 methodologies ((

}}2(a),(c) 1E-07 1E-06 1E-05 1E-04 1E-03 1E-02 1E-01 1E+00 0.00 0.20 0.40 0.60 0.80 1.00 Relative Concentration Cumulative Frequency

---PAVAN ---ARCON96

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 53 4.1.5.2 Test Case Two: Distance Comparison (( }}2(a),(c) Figure 4-10. Ratio of PAVAN to ARCON96 versus distance (data from Figure 4-9) (( were used and }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 54 ((

}}2(a),(c) 

}}2(a),(c) Figure 4-11. Ratio of PAVAN to ARCON96 versus distance (site data) ((

}}2(a),(c)

((

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 55 ((

}}2(a),(c)

Table 4-3. Site meteorological statistics

}}2(a),(c) 4.1.6 Application In order to utilize ARCON96 for offsite atmospheric dispersion calculations, the following methodology is utilized.

For each possible measured wind direction sector available in the input meteorological data (typically 16 sectors), ((

}}2(a),(c)

Ground level release (no credit taken for possible elevated release) ((

}}2(a),(c)

((

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 56 ((

}}2(a),(c) 4.2 Core Damage Event NuScale postulates a CDE to provide reasonable assurance that, even in the extremely unlikely event of a severe accident, the facilitys design features and site characteristics provide adequate protection of the public and operators. The CDE associated CDST is composed of a set of key parameters, such as fuel release fractions and timing, derived from a spectrum of surrogate accident scenarios that are utilized as inputs in radiological consequence calculations associated with the MHA.

The CDST is based on a major accident, postulated for the purpose of design analyses. Events that involve core damage with the subsequent release of appreciable quantities of fission products into an intact containment, as described in 10 CFR 52.47(a)(2)(iv), are addressed in the methodology. Relative risk insights are used, not to select a single risk-significant event, but to establish a range of events to be considered for the CDE radiological consequence calculation. 4.2.1 Definition of Core Damage Source Term A subset of the Level 1 PRA sequences is used to select the spectrum of surrogate accident scenarios considered for the establishment of the CDST. These sequences are all single module internal events at full power and assume an intact containment. The methodology directs that a range of surrogate accident scenarios be selected that involve significant damage to the reactor core, with subsequent release of appreciable quantities of fission products. NuScale design-specific MELCOR analyses are performed to calculate the timing and magnitude of fission product radionuclide release from failed fuel in selected core damage surrogate accident scenarios. For each surrogate accident scenario, key parameters such as the onset time for fission product release from the gap, duration of the gap plus early in-vessel release, and the gap plus early in-vessel release fractions for each major radionuclide group are calculated. The minimum onset time for fission product release from the gap, the release duration associated with minimum release onset time, and the median value of the release fractions determined from the spectrum of surrogate accident scenarios are established and used as the CDST. A summary of the CDST and radiological consequence modeling approach is as follows: a series of equipment failures results in significant core damage activity released from the fuel occurs over a calculated period of time and homogenously mixes in containment atmosphere

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 57 removal of aerosol occurs through natural processes inside the NuScale containment vessel leakage from containment is direct to the environment, with no removal mechanisms in reactor building (e.g., scrubbing, partitioning, deposition) onsite and offsite radiological consequences are calculated 4.2.2 Core Damage ((

}}2(a),(c) 4.2.2.1 Radionuclide Groups Release fractions for nine major radionuclide groups are evaluated as part of the methodology. Table 14 in the Sandia National Lab report SAND2011-0128 (Reference 7.2.10) provides an alternative set of radionuclide groups as compared to Table 5 of RG 1.183. This alternative set of radionuclide groups represents the current approach to severe accident progression, and therefore, was included in the methodology presented in this report. No elements are added or removed from the RG 1.183 selection in the methodology. Instead, the elements are assigned to different radionuclide groups.

Specifically, the alkaline earths and molybdenum groups are added and six elements are moved into different groups (Sr, Ba, Mo, Nb, Tc, and Zr). A summary of the radionuclide groups used for the methodology presented in this report are provided in Table 4-4.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 58 Table 4-4. Radionuclide groups Number Name Elements in Group 1 Noble Gases Kr, Xe 2 Halogens Br, I 3 Alkali Metals Rb, Cs 4 Tellurium Group Se, Sb, Te 5 Alkaline Earths Sr, Ba 6 Molybdenum Group Mo, Nb, Tc 7 Noble Metals Ru, Rh, Pd, Co 8 Lanthanides La, Nd, Eu, Pm, Pr, Sm, Y, Cm, Am 9 Cerium Group Ce, Pu, Np, Zr 4.2.3 Release Timing and Magnitude As with radionuclide groups, design-specific representative results for release timing and magnitude from severe accident evaluations are utilized for the methodology, in order to reflect current practices and appropriately model the specific event. ((

}}2(a),(c) 4.2.4 Aerosol Transport Analysis As discussed in detail in Section 4.3 of this report, natural deposition phenomena including sedimentation, diffusiophoresis, thermophoresis and hygroscopicity result in aerosol removal. The aerosol removal methodology described in this report utilizes the 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 59 aerosol removal code STARNAUA to track these various deposition phenomena in calculating time-dependent airborne aerosol mass and removal rates. ((

}}2(a),(c)

A summary of the aerosol transport and removal calculation process is described as follows: ((

}}2(a),(c) 4.2.5 Radiological Consequence Analysis The CDE onsite and offsite radiological consequence estimates utilize event-specific radionuclide groups, release timing and fractions, and aerosol removal. The aerosol removal rate as a function of time is input into RADTRAD, from which, along with other key inputs such as atmospheric dispersion factors and isotopic inventories, the radiological consequences are calculated.

The chemical form of radioiodine released to the containment atmosphere is assumed to be 95 percent cesium iodide (CsI), 4.85 percent elemental iodine, and 0.15 percent organic iodide in accordance with Appendix A of RG 1.183. The methodology considers cesium iodide as an aerosol. It is conservative for the CDE onsite and offsite radiological consequence estimates to follow the general methodology described in Section 3.0 of this report. Because the CDE is a beyond-design-basis event, more realistic analysis techniques may be utilized with appropriate justification. For example, with sufficient justification provided by the application referencing this report, it may be appropriate to utilize nominal atmospheric dispersion factors and isotopic inventories instead of 95th percentile or bounding values, or to credit deposition of radionuclides within the reactor building.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 60 4.3 Aerosol Removal and Transport ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 61 ((

}}2(a),(c)

Table 4-5. Summary of aerosol parameter ranges }}2(a),(c) Section 3.2 of Appendix A in RG 1.183 allows for credit to be taken for the reduction in airborne radioactivity in the containment by natural deposition within the containment. Specifically, two models are endorsed for use: (i) the SRP 6.5.2 model, or (ii) the NUREG/CR-6189 model. The model described in NUREG/CR-6189 (Reference 7.2.49) for natural aerosol removal applies to reactors of 1000 MWt and larger, and does not consider removal mechanisms other than sedimentation. As a result, this model does not apply to the NuScale design. Although Section 6.5.2 of the SRP addresses active containment spray systems, which the NuScale design does not have, the guidance describes a methodology acceptable to the NRC Staff for calculating fission product removal rates. Specifically, the guidance states models that include the following characteristics are reviewed on a case-by-case basis: chemical and physical processes that can occur during an accident mass-mean diameter of water droplets average water droplet fall height area of the interior surfaces of the containment In conformance with the aforementioned guidance from SRP 6.5.2, ((

}}2(a),(c)

((

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 62 4.3.1 STARNAUA As described in Section 3.1.6, STARNAUA models natural removal of containment aerosols by sedimentation and diffusiophoresis, and considers the effect of hygroscopicity (growth of hygroscopic aerosols due to steam condensation on the aerosol particles) on aerosol removal. STARNAUA also includes a model for thermophoresis and the capability to directly input steam condensation rate or condensation heat transfer rate, and total heat transfer rate (as provided externally via MELCOR containment thermal hydraulics code calculation). Tracking of particle size over time is based on a coagulation model that determines particle coagulation rate, and thus particle size distribution and settling velocities. Aerosols are discretized into a size distribution, or size bins, and tracked. The modeling of these phenomenon are described in greater detail in Sections 4.3.2-4.3.4. 4.3.2 Sedimentation The STARNAUA sedimentation removal, or gravitational settling, model uses the same deposition velocity formula as that used in the removal model of NUREG/CR-6189. The settling velocity for sedimentation is derived in Reference 7.2.45 from the Stokes equation as follows: = 2()/9 Eq 4-7 where = particle material density = gravitational acceleration = particle radius () = Cunningham slip correction factor = viscosity of the atmosphere = dynamic shape factor The Cunningham factor is given by () = 1 + 1.246+ 0.42exp(0.87

) Eq 4-8 where is the Knudsen number / and is the molecular mean free path in the atmosphere. 4.3.3 Phoretic Phenomena (Diffusiophoresis and Thermophoresis) Diffusiophoresis and thermophoresis are two phenomena in which aerosol molecules adhere to a surface due to a gradient, specifically steam (diffusio) or temperature (thermo). This phenomenon is not to be confused with plating in a physical chemistry sense of chemical adsorption that involves a chemical reaction between a molecule and a surface. STARNAUA phoretic phenomena modeling is consistent with aerosol removal modeling previously used in the design certification applications of passively cooled containment applications.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 63 For diffusiophoretic deposition velocity the following equation is used (Reference 7.2.45). =

+

Eq 4-9 where = steam mole fraction in the atmosphere = air mole fraction in the atmosphere = molecular weight of steam = molecular weight of air = steam condensation rate per unit area on wall surface = steam density in the atmosphere The thermophoresis model uses the equation of Talbot et. al. (Reference 7.2.47) for the thermophoretic deposition velocity. Reference 7.2.43 shows the equivalent thermophoretic velocity (shown here as for consistency) as = 2(+ )() Tg g0 (1 + 3)(1 + 2+ 2) Eq 4-10 where =

is the ratio of the thermal conductivities of the gas and particle. It is internally calculated at each time step. The term is set equal to the thermal conductivity of water. where is the gas temperature is the gas temperature far from the surface is the normal derivative of the gas temperature at the surface is the kinematic gas viscosity is the Knudsen number and () is the Cunningham slip correction factor, as have been previously defined.,, and are the slip, thermal, and momentum accommodation coefficients, respectively. Talbot et. al. give their best values as = 1.17, = 2.18, = 1.14. 4.3.4 Hygroscopicity Hygroscopicity, or the measure of a molecules water solubility, is an important phenomenon of interest in that it impacts aerosol particle growth and, therefore, sedimentation rate. (( }}2(a),(c) The model used in STARNAUA for non-hygroscopic and hygroscopic

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 64 condensational growth on particles is based on the Mason equation and is provided in Reference 7.2.45 as follows. Non-hygroscopic condensational growth:

= 2

1+

() Eq 4-11 where = bulk steam saturation ratio = surface tension of water on the particle or droplet = density of water on the droplet = latent heat of water on the droplet = heat conductivity of water vapor = molecular weight of water = binary diffusion coefficient of the steam/air atmosphere = steam saturation pressure = universal gas constant = absolute temperature For hygroscopic particles, the above equation must be modified as follows. Hygroscopic condensational growth:

= 2

1+

() Eq 4-12 The exponential term in the non-hygroscopic condensational growth equation represents the lowering of the saturation pressure at the surface of the droplet due to the curvature of the droplet, the so-called Kelvin effect. If the particle is hygroscopic or soluble, then there is an additional decrease in the saturation pressure due to the solute effect. This leads to an additional water activity term in the numerator of the equation. For dilute solutions with many hygroscopic species, the water activity can be determined by the following Reference 7.2.45 equation.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 65 = 1 1 +

Eq 4-13 Where is the van't Hoff factor and is the molality of each hygroscopic material dissolved in the droplet. 4.3.5 Aerosol and Elemental Iodine Removal Deposition of aerosol onto inner-containment surfaces results in removal. A key assumption of the NuScale aerosol transport methodology is no maximum iodine decontamination factor limit should be applied to natural aerosol removal phenomenon in the NuScale containment. The basis for this assumption is that this removal is facilitated by natural processes, as opposed to an active spray system. Additionally, as described in the following sections, the NuScale removal rate calculation methodology is based on calculated time-dependent airborne aerosol mass. This basis is in agreement with Section 3.3 of Appendix A of RG 1.183 in which it is stated that reduction in the removal rate is not required if the removal rate is based on the calculated time-dependent airborne aerosol mass. NuScale conservatively does not take credit for elemental iodine removal. Rather, only aerosol removal is credited. 4.3.6 Aerosol Resuspension and Revaporization Resuspension of aerosol particles from deposition surfaces is generally considered a transport mechanism of importance only for pipes. Additionally, resuspension is based on turbulent flow conditions (Reference 7.2.43), ((

}}2(a),(c)

Revaporization is considered a negligible transport mechanism in the containment. It is noted in Reference 7.2.43 that revaporization is unlikely for fission products of interest, considering maximum post-LOCA temperatures compared against vaporization temperature/pressure curves for fission products of interest. Although the aerosol transport modeling methodology does not include resuspension and revaporization effects explicitly, resuspension and revaporization effects are inherently included in the benchmarked experiments. ((

}}2(a),(c) 4.3.7 Charge Effects on Aerosol Removal Rates The effect of electrical charge on aerosol transport and removal in a containment atmosphere during accident conditions has been examined by several researchers, such as in Reference 7.2.49. A tendency for aerosol particles to become electrically charged is expected through radioactive decay, such as the loss of an electron in beta decay, and the ionization of gas in the intense radiation field. Based on Reference 7.2.49, aerosol 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 66 removal rates of charged aerosols are greater than that of neutral particles. ((

}}2(a),(c) 4.3.8 Aerosol Plugging

(( }}2(a),(c) 4.3.9 Experimental Benchmarking and Code Validation Experimental benchmarking of STARNAUA is performed as one basis for demonstrating the validation and applicability of this modeling tool to the expected conditions of the post-accident NuScale containment. ((

}}2(a),(c)

Aerosol removal models were developed in STARNAUA for the purpose of benchmarking against experimental data from the LWR Aerosol Containment Experiment (LACE) and Aerosol Behavior Code Validation and Evaluation (ABCOVE) tests. In all, benchmark models were prepared to compare calculated airborne aerosol concentration values with measured airborne concentration values from LACE tests LA4 and LA6, and ABCOVE tests AB5 and AB7. Models incorporated the previously discussed sedimentation, diffusiophoresis, thermophoresis, and hygroscopic removal phenomena. Brief descriptions of the tests are as follows.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 67 (( LA4 - Aerosol depletion with overlapping injection periods of mixed hygroscopic and non-hygroscopic aerosol, aerosol growth by coagulation and condensation of water vapor LA6 - Aerosol depletion with simultaneous injection of mixed hygroscopic and non-hygroscopic aerosol, aerosol growth by coagulation and condensation of water vapor, rapid containment depressurization AB5 - Aerosol depletion with a single component hygroscopic aerosol, aerosol growth by coagulation AB7 - Aerosol depletion with two hygroscopic aerosol species, aerosol growth by coagulation (( . }}2(a),(c) All benchmark models satisfied the acceptance criteria. Experimental benchmarking results are shown in Table 4-6 and Figure 4-12 through Figure 4-15. Table 4-6. STARNAUA experimental benchmarking results }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 68 Figure 4-12. Calculated and measured suspended aerosol concentrations in Test LA 4 Figure 4-13. Calculated and measured suspended aerosol concentrations in Test LA 6 (( }}2(a),(c) (( }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 69 Figure 4-14. Calculated and measured suspended aerosol concentrations in Test AB 5 Figure 4-15. Calculated and measured suspended aerosol concentrations in Test AB 7 (( }}2(a),(c) (( }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 70 4.3.10 Benchmarking to MAEROS NMAEROS, a component of MELCOR, is the NuScale version of MAEROS (October, 1982). NMAEROS is equivalent to MAEROS (October, 1982) with input/output edit differences only. MAEROS is used to simulate the evolution of an aerosol based on the particle mass. Physical phenomena included in the calculations are coagulation, sedimentation, and diffusion. Thermophoresis was not modeled. Models for diffusiophoresis and hygroscopicity are not included in the MAEROS code. As described in Reference 7.2.65, the general numerical approach of MAEROS uses sections (bins) defined by particle mass instead of particle dimensions. For N sections, MAEROS calculates a set of 2N(N+2) sectional coefficients. Each coefficient is a rate constant for a different transport mechanism. These coefficients, for a given containment, often depend only on gas temperature and pressure. Given this condition, the user can specify upper and lower temperature and pressure limits. These limits give four sectional coefficients corresponding to the four combinations of temperature and pressure limits. MAEROS is able to linearly interpolate temperature and pressure values that differ from the limits and perform calculations with aerosol components, where a component is a physical constituent of the aerosol. As described in Reference 7.2.43, MAEROS was originally developed in part to eliminate numerical diffusion that occurred in early aerosol codes through the use of a moving boundary numerical scheme for bin sizing. The aerosol sections, or bins, are defined by particle mass in MAEROS, as opposed to particle size as in STARNAUA. As a result, the numerical solution of the code, including time step sizes, is fundamentally different than that of STARNAUA. However, both codes utilize similar mechanics for coagulation and diffusion. As such, NMAEROS is appropriate for an independent code-to-code benchmark of STARNAUA with respect to the numerical solution of aerosol coagulation and diffusion. For the benchmark, a hypothetical test roughly inspired by the LACE experiment was crafted. In order to compare the models, the hygroscopic, diffusiophoretic, and leak models in STARNAUA were turned off. Thermophoresis in both models was turned off. NMAEROS has a turbulent coagulation model, which should not have any significant impact for the particle size range under consideration (Reference 7.2.43, Figure 5-7). The only difference between Case 1 and 2 is the aerosol source rate. Case 1 is prescribed a CsOH source rate of 6.15 grams/sec while Case 2 provides a source rate of 0.615 grams/sec. The test geometry that the geometric inputs are derived from is shown in the following table. CsOH injection occurs from time zero to 1800 seconds in both cases.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 71 (( (( Table 4-7. Test geometry

}}2(a),(c) 

}}2(a),(c) Figure 4-16. Benchmark Case 1 CsOH suspended concentration ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 72 (( }}2(a),(c) Figure 4-17. Benchmark Case 2 CsOH suspended concentration Overall, the benchmark resulted in close agreement between codes for the two evaluated cases, with mean STARNAUA-to-NMAEROS ratio of ((

}}2(a),(c) for Case 1 and (( 
}}2(a),(c) for Case 2. This results in an additional independent means of demonstrating the ability of STARNAUA for prediction of aerosol coagulation, sedimentation, and diffusion.

4.3.11 Application The description of the methodology to use STARNAUA for the CDE radiological consequence analysis is provided in Section 4.2.4 of this report. This methodology assumes NuScale-specific release magnitude and timing and thermal-hydraulic conditions calculated by MELCOR. General methods for calculating inputs for STARNAUA are described in this section. The aerosol species released into the containment are classified into the chemical groups defined in Table 4-4 (( . }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 73 ((

}}2(a),(c) For a given time step, the average release rate of radioactivity over a period of time can be evaluated by 

= / Eq 4-14 where

= release rate of radioactivity (Ci/s), 
= radioactivity (Ci),

D = total duration of release (s). Isotopic inventories source terms are provided in units of curies (Ci). For the purpose of modeling aerosol transport and removal, the mass is the physical property of concern. To convert from radioactivity (Ci) to mass (g), the relationship can be derived as 3.7 x 10

/= = ln(2)

Eq 4-15 = ln(2) 3.7 x 10 1

= 5.34 x 10

Eq 4-16 where, m = release aerosol mass (g),

= number of radioactive atoms, 
= decay constant (s-1) = ln(2)/T, T = half-life of radionuclide (s),

3.7 x 10 / = conversion factor from Ci to per second (Bq),

= molecular (atomic) weight (g/mol), and 

= Avogadros number = 6.022 x 10 mol-1 (( }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 74 ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 75 ((

}}2(a),(c)

For modeling aerosol, STARNAUA also requires the input of density and molecular weight for each aerosol species. Eight aerosol species are modeled; each corresponding to a chemical group. Therefore, each species is a mixture of various elements with all associated isotopes. For each species (a mixture), the effective molecular weight of an isotopic mixture can be weighted as =

Eq 4-22 where MM = average mass multiplier of an isotopic mixture. Similarly, the effective density of the species can be obtained by =

=

Eq 4-23 where PF = packing factor.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 76 It is noted that the apparent density used in the above equation is equal to the tabulated density multiplied by a packing factor. However, the density and molecular weight of an aerosol species is also dependent on the chemical form. In Table 13 of NUREG-6189 (Reference 7.2.49), possible chemical forms of aerosol species released into the reactor containment are listed with the mass multipliers of molecular weight. The mass multiplier for a chemical compound is defined as the molecular weight of the compound over the atomic weight of the element. For a polyatomic compound of k atoms, the mass multiplier of molecular weight is:

=,

/ Eq 4-24

where,

, = molecular weight (atomic mass) of atom j in the compound (g/mol),

= molecular (atomic) weight of the source nuclide.

This average mass multiplier is estimated for each chemical group in the aerosol modeling. The effective molecular weight for an aerosol species in Eq 4-22 can be obtained by modifying with the mass multiplier. The range (minimum and maximum) of molecular mass multipliers to account for the uncertain chemical form of radionuclides defined in Table 13 of NUREG/CR-6189 are reproduced in Table 4-8 with an additional column of the average value between the maximum and minimum. As the molybdenum group was not provided in NUREG/CR-6189, and at the time was included in the noble metals group, the value of the noble metals group is utilized for the molybdenum group. Table 4-8. Radionuclide group molecular mass multipliers Group Min Max Average Halogens 1.00 1.38 1.19 Alkali Metals 1.05 1.22 1.14 Tellurium Group 1.00 1.25 1.13 Alkaline Earths 1.11 1.67 1.39 Molybdenum 1.00 1.47 1.24 Noble Metals 1.00 1.47 1.24 Lanthanides 1.11 1.17 1.14 Cerium 1.17 1.22 1.20 Section II.G.5 of NUREG-6189 (Reference 7.2.49) and Reference 7.2.43 provide aerosol densities and molecular weights of principal interest. As a result, the physical properties of containment aerosols, the densities and molecular weights can be calculated for input into STARNAUA, from which the containment aerosol removal rate is determined.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 77 4.4 Post-Accident pHT This section presents the methodologies utilized for evaluating post-accident pHT in coolant water following a significant core damage event such as the CDE. The symbol pHT is used to emphasize dependence on temperature. This term is synonymous with the traditional symbol pH, which is typically calculated at room temperature. The pHT is used for calculating the extent of iodine re-evolution inside containment. During the postulated CDE, additional acids and bases are expected to enter the coolant and cause a change in pHT. The overall pHT of the coolant is expected to be modeled over a time period of 30 days. Though its not expected, a design that utilizes this methodology could contain halogenated cable insulation in containment. Therefore, hydrochloric acid is included in the methodology. A summary of the parameters that influence pHT are as follows: Boric Acid: Boron is added to the RCS in the form of boric acid in order to control core reactivity. Although its concentration varies throughout the fuel cycle, (( . }}2(a),(c) Boric acid is a weak acid whose strength is dependent on temperature. Lithium Hydroxide: Lithium hydroxide is assumed to be added to the RCS in order to neutralize the acidic environment caused by boric acid. The amount of lithium hydroxide does not change from its initial value at a specific point in time when this analysis is performed. Lithium hydroxide is a strong base. Hydriodic Acid: Of the iodine released from the core as part of the CDE, 95 percent is assumed to be in the form of cesium iodide while the remaining 5 percent is assumed to either be hydriodic acid or organic iodine (Reference 7.2.52). Hydriodic acid is a strong acid. Cesium Hydroxide: Cesium released from the core as part of the CDE enters the coolant as either cesium iodide or cesium hydroxide. Some of the released cesium hydroxide may react with boron oxides and form cesium borates. Cesium hydroxide is a strong base. Nitric Acid: Nitric acid is generated by a radiolysis reaction in the liquid coolant (Reference 7.2.52). The irradiation of water at a water/air interface results in the generation of Nitric Acid. The amount of nitric acid in the coolant continually grows over the 30 day period. Nitric acid is a strong acid. Hydrochloric Acid: Hydrochloric acid is formed by a radiolysis reaction in power cable insulation that contains halogens (Reference 7.2.52). If halogenated cable insulation were used in the design that implements this methodology, then the amount of hydrochloric acid in the coolant would continually grow over the 30 day period. Hydrochloric acid is a strong acid. Temperature: The temperature of the coolant controls the neutral pHT of the system. As temperature increases, the neutral pHT decreases. At 100 degrees Celsius, the neutral pHT of an aqueous system will be ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 78 The pHT of a system is dependent on the concentration of the hydronium (H3O+) in the aqueous system. The hydronium concentration, often simplified as H+, is controlled by the self-dissociation of water and the presence of any acids and/or bases. The pHT of an aqueous system is calculated as pH= Log(H) Eq 4-25 The hydronium concentration H+ can be calculated from a system of equations that includes: the dissociation of acids/bases, mass balance of the chemical species, and charge balance of all ions in the system. Concentrations used in this calculation are in terms of molality. Molality is defined as

() = Eq 4-26 4.4.1 Dissociation Equation The dissociation equation describes to what extent each chemical species dissociates (separates) into ionic form. This dissociation of a generic acid or base will form an equilibrium described by HA H+ A Eq 4-27 BOH B+ OH Eq 4-28 Water is unique in that it undergoes self-ionization, where a water molecule dissociates into a hydrogen and hydroxide ion. HO H+ OH Eq 4-29 The rate at which these reactions occur at equilibrium is governed by the dissociation constant K which is defined as the ratio of concentrations of products to reactants. The dissociation constant for water, a generic acid, and a generic base are defined as K= HOH Eq 4-30 K= HA HA Eq 4-31 K= BOH BOH Eq 4-32

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 79 The value of K for a specific dissociation reaction can be measured experimentally. Dissociation constant values for water, lithium hydroxide, and boric acid are taken from Reference 7.2.54. Table 4-9. Dissociation constants of assumed acids and bases Reaction Equation Dissociation Constant, K HO H+ OH Log(K) = 14.9378 + 0.0424044 T(°C) 2.10252E-4 T(°C) +6.22026E-7 T(°C) 8.73826E-10 T(°C) LiOH Li+ OH Log(K) = 0.7532 0.0048 T(°C) + 6.746E-6 T(°C) B(OH) + OH B(OH) Log(K) = 1573.21 T(°K) + 28.8397 + 0.012078 T(°K) 13.2258 log T(°K) 2 B(OH) + OH B(OH) Log(K) = 2756.1 T(°K) 18.996 + 5.835 log T (°K) 3 B(OH) + OH B(OH) Log(K) = 3339.5 T(°K) 8.084 + 1.497 log T(°K) 4 B(OH) + 2 OH B(OH) Log(K) = 12820 T(°K) 134.56 + 42.105 log T(°K) 4.4.2 Mass Balance Equation The mass balance equation conserves the total mass of an element or compound found in the coolant. The equations for a generic acid and base are defined as A= HA+ A Eq 4-33 B= BOH+ B Eq 4-34 4.4.3 Charge Balance Equation The charge balance equation shows that the net charge of positive ions must equal the net charge of negative ions. In an aqueous solution consisting of a single acid and base, the charge balance equation is H+ B= OH+ A Eq 4-35 pHT can be calculated by solving the charge balance equation for H+. This calculation requires that equations are derived for B+, OH-, and A-in terms of H+. The value of OH-can be found by rewriting Eq 4-30.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 80 OH= K H Eq 4-36 The value of A-can be found by substituting HA from Eq 4-34 into Eq 4-32 and solving for A-. K= HA AA Eq 4-37 KA= AH+ AK Eq 4-38 A= KA (H+ K) Eq 4-39 Similarly, the value of B+ can be found by substituting BOH from Eq 4-35 into Eq 4-33 and using Eq 4-37 to substitute for OH-. B= KB K H

+ K Eq 4-40 With Eq 4-36, Eq 4-39, and Eq 4-40 defining OH-, A-, and B+ written in terms of H+, the charge balance equation (Eq 4-35) can be written as H+ KB K H

+ K = K H+ KA (H+ K) Eq 4-41 Eq 4-41 can be solved for H+ using a variety of numerical techniques. Once H+ is found, the pHT of the aqueous system is calculated using Eq 4-25. 4.4.4 Final Charge Balance Equation The methodology described in the previous sections is expanded to include any number of acids and bases. Incorporating the ionic concentrations from lithium hydroxide, cesium hydroxide, hydrochloric acid, nitric acid, hydriodic acid, and boric acid into the charge balance equation gives

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 81 + + = + + + + () +() + () + 2 () Eq 4-42 The () ion is multiplied by two to account for the negative two charge of the ion. 4.4.5 Concentration of Ionic Species In order to solve the final charge balance equation (Eq 4-42), equations for the concentration of each ionic species in the system must be derived in terms of H+. A discussion of these equations is presented in the following section. 4.4.5.1 Equations for Concentration The equations describing the concentrations of Li+, Cs+, I-, Cl-, and NO3-are presented in Table 4-10. The concentration of Li+ was derived using methodology from Section 4.4.3. Concentrations of Cs+, I-, Cl-, and NO3-are based on assumptions for dissociation. Cesium hydroxide is assumed to undergo 95 percent dissociation at all temperatures per Reference 7.2.55 in which cesium hydroxide is a strong base, which typically undergoes nearly 100 percent dissociation. Assuming 95 percent dissociation conservatively weakens cesium hydroxide compared to other strong acids in the coolant over all temperature ranges. The acids hydriodic acid, hydrochloric acid, and nitric acid are considered strong acids at all temperature ranges, and thus undergo 100 percent dissociation. Assuming full dissociation ensures that the amount of dissociation these acids undergo is over-estimated, and therefore, conservative.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 82 Table 4-10. Concentration equations of included chemical species Chemical Aqueous Reaction Concentration in Terms of [H+] Equation Number Lithium Hydroxide

+ 

=

+ Eq 4-43 Cesium Hydroxide

+ 

= 0.95 Eq 4-44 Hydriodic Acid

+

I= 1.0 I Eq 4-45 Hydrochloric Acid

+

Cl= 1.0 Eq 4-46 Nitric Acid

+ 

= 1.0 Eq 4-47 Boric acid is unique from other chemical species in this calculation in that it can undergo one of four separate aqueous reactions (Reference 7.2.54). The equations for the concentration of each ionic species of boron are given in Table 4-11. These equations include a B(OH)3 term, the solution of which is derived in the following section.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 83 Table 4-11. Concentration equations of boric acid ionic species Boric Acid Ion Aqueous Reaction Concentration in Terms of [H+] Equation Number B(OH)4-() + () () = ()

Eq 4-48 B2(OH)7-2 () + () () = ()

Eq 4-49 B3(OH)10-3 () + () () = ()

Eq 4-50 B4(OH)14-2 4 () + 2 ()

() = ()

Eq 4-51 4.4.5.2 [B(OH)3] Solution The term B(OH)3 found in Eq 4-48 through Eq 4-51 can be solved using the mass balance equation for boric acid. B= ()+ () + () + ()

+ () Eq 4-52 Eq 4-48 through Eq 4-51 can be substituted into Eq 4-52 to give Boron= ()+ ()

+ ()

+ ()

+ ()

Eq 4-53 A variety of root finding methods can be applied to Eq 4-53 at a constant value of H+ in order to converge a solution for B(OH)3. The solution to B(OH)3 can then be applied to Eq 4-48 through Eq 4-51.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 84 4.4.6 Iodine Re-evolution An estimate for iodine re-evolution was made using Figure 3-1 of NUREG/CR-5950 (Reference 7.2.52), shown as Figure 4-18 in this report. This data was used as the basis for an acceptance criteria of greater than or equal to seven in Reference 7.2.2. According to this figure, less than one percent of aqueous iodine is converted into molecular I2 at a pHT of 6.0. The derived methodology is performed at 25 degrees Celsius to match available experiment data; thus no temperature dependence is included in the model. The methodology of this report assumes that for pHT values of 6.0 or greater, the negligible amount of iodine re-evolution that could occur between pHT values of 6.0 and 7.0 does not need to be explicitly included in the dose analysis calculation. This position simplifies the analysis without an impact to the conservatism of the calculated dose results. Figure 4-18. Iodine re-evolution versus pH (Reference 7.2.52)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 85 5.0 Example Calculation Results Example calculation analyses and results are presented in this section to demonstrate the application of the methodology described in this report. These results are for illustrative purposes. Examples are provided in this section for offsite and onsite atmospheric dispersion factors, severe accident event selection, example severe accident analysis, containment aerosol removal, radiological consequence analyses, and post-accident pHT. Some examples provided in Section 5 are based on a superseded preliminary version of the NuScale design. Since the purpose of these example results is illustrative and the changes in results would not be large enough to provide new insights into the application of the methodologies, the example results are not updated as methodology changes and revisions to this report occur. Differences in the methodologies originally utilized to create these example results and the methodologies stated in the current revision of this report are noted in the associated Section 5 subsections as appropriate. 5.1 Atmospheric Dispersion Factors An applicant that implements this methodology is expected to use site-specific atmospheric dispersion factors calculated from qualified site-specific meteorological data obtained from a site specific RG 1.23 compliant meteorological monitoring program. In order to demonstrate the application of this methodology, this report assumed a three year data span for Sacramento, California from 1984 to 1986 in example calculations, described in Section 5.2 and Section 5.3. This representative site is assumed to occur on flat ground with nominal surface features (i.e., default surface roughness). An applicant who utilizes this methodology is expected to evaluate the applicability of the atmospheric dispersion modeling methodology for any significant site-specific geographical features. The example site information evaluated in this section is a representative example and is intended to illustrate how dispersion factors are calculated utilizing the methodology from Section 4.1 (with the exceptions of ((

}}2(a),(c)) as applied to a set of U.S.

meteorological data. In order to establish an appropriate site and associated meteorological dataset that could be used to develop atmospheric dispersion factors in a design certification, the methodology from Section 4.1 (with the exceptions of ((

}}2(a),(c)) is applied to a set of U.S. meteorological data from 241 sites across the U.S. from which a site representative of an 80-90th percentile U.S. site was selected; as recommended in the advanced light water reactor (ALWR) utility requirements document (URD), Reference 7.2.42 (which specifically recommended 80-90th percentile). The selected site meteorological data is then used in example calculations of offsite and control room atmospheric relative concentration values. 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 86 The EPAs Air Quality Modeling Group maintains the Support Center for Regulatory Atmospheric Modeling, a website that contains many tools related to atmospheric modeling (Reference 7.2.64). This website includes a database of hourly U.S. meteorological observations taken from the National Climatic Data Center (NCDC), which contains one or more years of surface meteorological data for various National Weather Service (NWS) stations across the U.S. The database also provides twice daily mixing height data for various NWS stations. Both of the observations described above-surface and mixing height data-are required as input to PCRAMMET, a meteorological processor available on the EPA website. PCRAMMET processes the data and calculates stability class for each hour. The output file contains all of the hourly values required as input to ARCON96. The selected dataset contains 241 sites, each with three or more years of observations, and represents geographical diversity as shown in Figure 5-1. Figure 5-1. Map of each surface data site in the selected EPA dataset The PCRAMMET method for calculating stability class uses the Pasquill-Gifford Turner method, which relies upon evaluation of solar insolation and cloud conditions to determine stability. This method is different from the delta-T method in RG 1.23. Both stability classes utilize seven stability classes (A thru G). Atmospheric dispersion factors are affected by the different methods, as each method is expected to produce different

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 87 stability classes based on the same raw meteorological data (if the parameters for both methods existed in the data). RG 1.23 recommends use of the delta-T method for determining Pasquill stability classes for licensing purposes. However, site-specific information is necessary in order to utilize the delta-T methodology. In the absence of this site-specific information, the Pasquill-Gifford Turner method is used in this example. The Pasquill-Gifford Turner method utilized by PCRAMMET, while different from the delta-T method, is recommended by the EPA and only requires standard NWS observations, which are widely available. Reference 7.2.63 performs a comparison of the two methods, with the delta-T method resulting in the highest frequency of limiting case stability (F, G) with a mean deviation between the two methods of 0.38. ((

}}2(a),(c)

All of the selected observations in the database were recorded between 1984 and 1992. There are more surface data sites than mixing height data sites; therefore, each surface data site is coupled with the nearest mixing height data site in order to produce the relevant inputs. The selected database was originally recorded and published by the NCDC. Each site contains three or more years of data, and the database represents sufficient geographical diversity as illustrated in Figure 5-1. For these reasons, the 80-90th percentile of this database should sufficiently serve as meteorological data representative of an 80-90th percentile U.S. site. 5.1.1 Offsite Dispersion Factors The postulated NuScale EAB and outer boundary LPZ distance is at the owner-controlled area boundary. As shown in Figure 5-2, there are several hypothetical locations that a release could occur. The selection of release location affects the distance between the release point and the EAB and LPZ, which is utilized to calculate the offsite dispersion factor. This distance could be recalculated on a case specific basis to provide realistic results, however, NuScale assumed the shortest distance of 400 feet in its example calculations to be conservative for all releases.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 88 Figure 5-2. Markup of site layout with analytical offsite distances overlaid The example analysis assumed a conservative cross sectional building area of 0.01 square meters, since smaller cross sectional building areas have been observed to produce larger relative concentrations. Note that ARCON96 has only one input for cross sectional building area and therefore this input accounts for the effect of all buildings between the source and receptor. All source geometries were assumed to be from a ground-level point source; no elevated, vent, heated, or diffuse sources were considered. The site terrain elevation differences were assumed to be zero. ARCON96 was executed using data from each of the geographical sites in the selected meteorological database and executed 16 times for each site; once for each direction sector. The sectors are centered at ~22.5 degree intervals ((

}}2(a),(c) and each is 90 degrees in width,

((

}}2(a),(c). The maximum relative concentrations were selected for each site at each time period and distance. A set of 80th percentile relative concentrations and a set of 90th percentile relative concentrations were established by ordering the data from least to greatest and selecting the 80th and 90th percentile data points for each distance and each time period. Selection of an 80-90th percentile site is based on establishing a site whose relative concentrations typically fall between the 80th and 90th percentile relative concentration data sets. 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 89 Through this process the data span of 1984 to 1986 for the Sacramento, California site was chosen as the 80-90th percentile site. During this selection process importance was placed upon the 0 to 2 hour relative concentration as it typically dominates in dose calculations. Table 5-1 shows the selected site and its relative concentration for each time interval. Highlighted in grey in Table 5-1, the 8 to 24 hour interval of the selected site falls below the 80th percentile at some distances. This result is because the distribution of sites changes when downwind distance is changed. In other words, there is no site in the database that represents the 80-90th percentile at every distance and time interval. However, across all distances, this site is the most conservative and the best representation of the 80-90th percentile. Table 5-1. Time-interval relative concentrations for selected site Downwind Distance (m) 0-2 hour 2-8 hour 8-24 hour 1-4 day 4-30 day 33 6.88E-03 5.65E-03 2.46E-03 2.47E-03 2.28E-03 66 1.86E-03 1.51E-03 6.72E-04 6.71E-04 6.13E-04 122 5.72E-04 4.84E-04 2.13E-04 2.15E-04 1.95E-04 201 2.28E-04 1.94E-04 8.46E-05 8.59E-05 7.83E-05 402 7.01E-05 5.89E-05 2.61E-05 2.55E-05 2.37E-05 805 3.44E-05 2.43E-05 1.09E-05 1.06E-05 9.51E-06 1609 2.28E-05 1.50E-05 5.95E-06 5.90E-06 5.30E-06

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 90 Figure 5-3. Histogram of calculation results at 33 meters Figure 5-4. Histogram of calculation results at 122 meters 0.0 2.0 4.0 6.0 8.0 10.0 12.0 5.4 5.6 5.8 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4 Frequency (%) Relative concentration (x 10 - 3) 0.0 2.0 4.0 6.0 8.0 10.0 12.0 4.5 4.7 4.8 5.0 5.1 5.3 5.5 5.6 5.8 5.9 6.1 Frequency (%) Relative concentration (x 10 - 4)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 91 Table 5-2 presents the ratio of the selected relative concentration to the true 90th percentile relative concentration in the dataset. Though not all values represent the 80-90th percentile of the dataset, all of them are reasonably close in magnitude. There are five values below the 90th percentile of the dataset, but all of them are close to the 90th percentile in magnitude. Considering this relationship, and the fact that many of the selected concentrations are well above the 90th percentile, the selected site is justified for use as the 80-90th percentile of the dataset. Table 5-2. Ratio of selected relative concentration to true 90th percentile Downwind Distance (m) 0-2 hour 2-8 hour 8-24 hour 1-4 day 4-30 day 33 1.00 1.02 0.88 0.98 1.08 66 1.01 0.99 0.88 0.98 1.07 122 1.00 1.01 0.88 0.99 1.08 201 1.00 1.02 0.88 0.99 1.06 402 1.01 1.00 0.92 0.96 1.03 805 0.99 0.93 1.15 1.06 1.06 1609 0.90 0.96 1.25 1.08 1.13 Using the methodology specified in Section 4.1 of this report (with the exceptions of ((

}}2(a),(c), offsite atmospheric relative concentration values for the site located in Sacramento, California for the data span of three years (1984 to 1986) were calculated. These relative concentrations (shown in Table 5-4) are used in example dose calculations in this report. An applicant is expected to use site-specific atmospheric dispersion factors calculated from qualified site-specific meteorological data obtained from a site specific RG 1.23 compliant meteorological monitoring program. Use of NWS data is only for the purpose of illustrating the derivation of reasonable atmospheric relative concentration values for the example calculations in this report.

Table 5-3. Selected meteorological data WBAN Location Number of Years Span of Years 23232 Sacramento, California 3 1984-1986 The calculated offsite dispersion factors are presented in Table 3-2.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 92 Table 5-4. Example offsite atmospheric relative concentration (X/Q) values Distance 0-2 hour 2-8 hour 8-24 hour 1-4 day 4-30 day (feet) (meters) (s/m3) (s/m3) (s/m3) (s/m3) (s/m3) 400 121.9 5.72E-04 4.85E-04 2.14E-04 2.15E-04 1.95E-04 5.1.2 Control Room and Technical Support Center Dispersion Factors Possible reactor or turbine building source locations, including doors, heating, ventilation, and air conditioning (HVAC) inlets and outlets, and penetrations, were examined for determining the limiting source locations. For the control room envelope and technical support center, personnel access doors and HVAC inlets were examined as possible receptor locations. In these example calculations, the control room ventilation air exhaust was not included as a control room receptor, because it was assumed that the control room emergency air will be continuously discharged through this location. Utilizing the three dimensional coordinates provided by building drawings, the total and horizontal distances between source and receptor were calculated for each source-receptor combination. The total taut-string distance was considered as a vector length, therefore the standard equation for calculating vector lengths was utilized. The resultant control room atmospheric dispersion factors are presented in Table 5-5 for the limiting control room source-receptor distance. Table 5-5. Example control room atmospheric dispersion factors Distance 0-2 hour 2-8 hour 8-24 hour 1-4 day 4-30 day (feet) (meters) (s/m3) (s/m3) (s/m3) (s/m3) (s/m3) 111.78 34.1 6.27E-03 5.37E-03 2.31E-03 2.35E-03 2.13E-03 5.2 Design Basis Source Terms Example dose results from the DBSTs described in Section 3.2 of this report are shown in Table 5-6. The acceptance criteria in Table 5-6 are taken from SRP Section 15.0.3. These example calculations utilized the dispersion factors associated with the limiting 80th-90th percentile site described in Section 5.1, and the general methodologies described in Section 3.3 (with the exception of the method utilized to calculate the iodine decontamination factor for the pool during a fuel handling accident), as applied to the example design assumed in these evaluations. For this example, the smallest margin between calculated and acceptance criteria dose is a factor of 7 smaller between the 5 Roentgen equivalent man (rem) control room dose acceptance criteria and the 0.72 rem calculated value. A sensitivity study was performed for the SGTF and MSLB events assuming the liquid secondary coolant in the steam generator was at the primary coolant design basis limit concentration. This study resulted in an EAB dose increase of 1.4E-03 rem TEDE, as compared to the acceptance criteria of 2.5 rem or 25 rem, depending on the iodine

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 93 spiking scenario assumed. Compared to the most limiting case from the applicable example calculations below, this result corresponds to a negligible 0.2 percent difference for the SGTF event with pre-incident iodine spiking. Table 5-6. Example dose results for design-basis source terms Event Location Acceptance Criteria (rem TEDE) Dose (rem TEDE) rod ejection accident (containment release) EAB 6.3 0.011 LPZ 6.3 0.144 CR 5 0.131 rod ejection accident (primary system release) EAB 6.3 0.001 LPZ 6.3 0.001 CR 5 0.004 fuel handling accident EAB 6.3 0.362 LPZ 6.3 0.362 CR 5 0.313 main steam line break (pre-incident iodine spike) EAB 25 0.004 LPZ 25 0.019 CR 5 0.023 main steam line break (coincident iodine spike) EAB 2.5 0.0004 LPZ 2.5 0.0014 CR 5 0.0013 steam generator tube failure (pre-incident iodine spike) EAB 25 0.637 LPZ 25 0.663 CR 5 0.720 steam generator tube failure (coincident iodine spike) EAB 2.5 0.039 LPZ 2.5 0.040 CR 5 0.002 primary coolant line break EAB 2.5 0.062 LPZ 2.5 0.062 CR 5 0.075 iodine spike DBST* (pre-incident iodine spike) EAB 25 <0.01 LPZ 25 <0.01 CR 5 <0.01 iodine spike DBST* (coincident iodine spike) EAB 25 <0.01 LPZ 25 <0.01 CR 5 <0.01

  • Note: The iodine spike DBST is not an event, but rather a bounding source term associated with DBEs that result in primary coolant entering the containment.

5.3 Example Core Damage Source Term Selection Process As described in Section 4.2 of this report, before establishing the CDST a spectrum of representative surrogate accident scenarios must be selected. With respect to the

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 94 design evaluated in this report, the following is taken into consideration when establishing the proper spectrum of representative surrogate accident scenarios. Based on severe accident analyses, all intact containment significant core damage scenarios involve the demand and failure of the emergency core cooling system (ECCS). Assessment of the ECCS has determined that incomplete actuation of the ECCS is both a more probable and more limiting failure mode than complete failure of all ECCS valves. However, ECCS failures consider the failure of all reactor recirculation valves (RRVs), all reactor vent valves (RVVs), or all ECCS valves. In this example, the ECCS was demanded in one of two ways:

1) high liquid level in the containment
2) loss of DC power (LODC)

While there are numerous possible LOCA pathways into the containment, the most limiting assumed in this report is a break of the CVCS injection line. The inlet to this line is assumed to lie directly above the core in the riser and is assumed to be at a lower elevation than any other RPV penetration, other than the ECCS RRVs. As a result, a postulated break of the CVCS injection line leads to the most rapid loss of inventory of any LOCA evaluated and provides the most direct pathway for fission product release from the RPV. A LODC is assumed to cause an ECCS demand because of the fail-safe design of the ECCS valves. In normal operation, the example assumes DC power energizes the solenoids that hold the valves in the closed position. Although a LODC is assumed to de-energize the solenoids and trip ECCS, the inadvertent actuation block2 is assumed to prevent the valves from opening if the system is at or near operating pressure. The system is assumed to depressurize via either the decay heat removal system (DHRS) or cycling of the reactor safety valves before the ECCS valves open. The reactor safety valves are assumed to actuate only on high RPV pressure. The example surrogate accident scenario spectrum selected to provide example CDST results are shown in Table 5-7. These selections are based on the aforementioned reasons. The example surrogate accident scenario cases shown in Table 5-7 cover a complete failure of ECCS and both types of incomplete ECCS actuation, and are assumed to initiate with either a LODC or a break of the CVCS injection line into the containment. No mitigating operator actions are considered and the availability of the DHRS is varied between the cases. 2 Inadvertent actuation block is a design feature to prevent ECCS valves from opening during module operation, when high differential pressure exists across the valve.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 95 Table 5-7. Spectrum of example surrogate accident scenario cases considered for creation of CDST Case Coolant Flow Path ECCS Case 1 CVCS injection line break Complete failure Case 2 CVCS injection line break RVVs fail to open Case 3 CVCS injection line break RRVs fail to open Case 4 Loss of DC power system RVVs fail to open Case 5 Loss of DC power system RRVs fail to open 5.4 Example Severe Accident Analysis Surrogate accident scenario case 2 is the most limiting of the five examples shown in Table 5-7 with respect to both time to core damage and release duration. Only the source term analysis associated with surrogate accident scenario case 2 is provided as an example in this report. Surrogate accident scenario case 2 is assumed to initiate with a break of the CVCS injection line at the top of the containment. Actuation of the ECCS is demanded by high liquid level in the containment. For this example sequence, the RVVs are assumed to fail while the RRVs open on demand. This incomplete ECCS actuation accelerates the loss of coolant to the containment until the core becomes uncovered and the fuel begins to heat up. However, the open RRVs result in reflooding of the core following the transport of noncondensable gas to the containment. The result is a limited release of fission products from the fuel and a short release duration. Figure 5-5 through Figure 5-12 provide example results from the source term analysis associated with surrogate accident scenario case 2. Figure 5-5. Example surrogate accident scenario case 2 short-term RPV and CNV pressures

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 96 Figure 5-6. Example surrogate accident scenario case No. 2 long-term RPV and CNV pressures Figure 5-7. Example surrogate accident scenario case 2 RPV and CNV collapsed liquid levels Figure 5-8. [Reserved] Figure 5-9. [Reserved]

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 97 Figure 5-10. Example surrogate accident scenario case 2 representative containment temperatures Figure 5-11. Example surrogate accident scenario case 2 release fractions from fuel Figure 5-12. Example surrogate accident scenario case No. 2 release fractions into containment

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 98 5.5 Representative Severe Accident Results Table 5-8 provides relevant fission product release information generated from MELCOR for the five example surrogate accident scenario cases. The fission product release information for each of the example surrogate accident scenario cases is compared to the values from RG 1.183 and the low burnup, low enriched uranium release fractions from SAND2011-0128. For interpreting NuScale specific MELCOR results, the following definitions are provided: onset of gap release: assumed to occur at the start of clad ballooning as in SAND2011-0128 duration of gap plus early in-vessel release: the first cladding failure to time when the release from the fuel ends

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 99 Table 5-8. Comparison of release timing and magnitudes of example surrogate accident scenario cases Description Case 1 Case 2 Case 3 Case 4 Case 5 Median Value RG 1.183 Current SAND 2011-0128 onset of gap release (hr) 17.6 3.8 8.1 6.2 21.3 8.1 30 sec 30 sec duration of gap plus early in-vessel release (hr) 12.0 1.0 9.0 1.3 14.0 9.0 1.8 5.63 fraction of initial core inventory released into containment noble gases 0.39 0.19 0.41 0.19 0.48 0.39 1 0.872 halogens 0.21 3.5E-2 0.16 1.9E-2 0.14 0.14 0.4 0.307 alkali metals 0.25 5.9E-2 0.22 3.1E-2 0.20 0.20 0.3 0.235 alkaline earths 5.9E-3 2.8E-3 6.7E-3 2.4E-3 5.3E-3 5.3E-3 0.02 0.0054 tellurium group 0.22 3.8E-2 0.16 2.3E-2 0.15 0.15 0.05 0.267 molybdenum 6.4E-2 1.3E-2 5.3E-2 5.8E-3 4.9E-2 4.9E-2 0.0025 0.1 noble metals 1.2E-03 1.2E-4 1.5E-3 4.9E-5 7.9E-4 7.9E-4 0.0025 0.006 lanthanides 3.3E-8 2.6E-9 3.1E-8 1.1E-9 2.1E-8 2.1E-8 0.0002 1.1E-07 cerium group 3.3E-8 2.6E-9 3.1E-8 1.1E-9 2.1E-8 2.1E-8 0.0005 1.1E-07

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 100 As observed from Table 5-8, the nine example median release fractions of the radionuclide groups are bounded by those in SAND2011-0128. These NuScale design-specific median release fractions are used for the CDE radiological consequence example calculation in this report. This onset time is delayed relative to RG 1.183 onset time, with a range of 3.8 to 21.3 hours. Similarly, the duration of release is similar to or much greater than RG 1.183 with calculated values of 1.0 to 14.0 hours. 5.6 Example Containment Aerosol Transport and Removal Example containment aerosol transport and removal calculations, including sensitivity cases, are provided in this section. These example calculations utilize methodology described in Section 4.3 of this report, as applied to the example design. The injection rates, aerosol properties, and aerosol removal rates and concentrations were calculated using the previously discussed MELCOR and STARNAUA computer codes. Example surrogate accident scenario cases from Section 5.5 are utilized, with the release timing (onset and duration) and release fractions applied from Table 5-8. Aerosol parameters are taken from Table 4-5 and biased to a conservative direction as suggested by example Table 5-18. All other aerosol input parameters utilize the nominal or default values, which must be shown to be conservative, as appropriate, with respect to the parameter-specific bias direction in design calculations. The accident scenarios of concern are intact containment core damage with the median release fractions along with surrogate accident scenario case No. 2 used as the baseline case for aerosol study. Surrogate accident scenario case 5 is chosen for analysis in a sensitivity case because it is the most probable of the five surrogate accident scenario cases considered. Results of the baseline and sensitivity case are summarized in Table 5-9. Table 5-9. Example accidents for aerosol simulation Case Name Onset of Release (hr) Release Duration (hr) Release Fractions Pressure / Temperature Baseline 3.8 1.0 Median Case 2 Sensitivity 21.3 14.0 Case 5 Case 5 Figure 5-13 is a plot of containment aerosol concentration and removal as a function of time for the baseline case as calculated by STARNAUA. The end of aerosol release injection occurs at 4.8 hours, 3.8 hours after onset of event and 1 hour of release duration (3.8+1=4.8). Between 3.8 hours and 4.8 hours the linear injection of aerosol into containment results in growth of the containment concentration at a relatively constant rate. Removal is occurring, but is being outpaced by concentration addition during this injection period. At 4.8 hours with the end of release, a period of stable removal of aerosol through sedimentation and other mechanisms begins and results in an exponential decay of the concentration as the average size of the aerosol molecules increases exponentially, as displayed in Figure 5-14. While the relative removal rate remains stable, less and less aerosol is available to remove, and the aerosol concentration continues to decrease exponentially.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 101 Figure 5-13. Baseline case aerosol concentration and removal Figure 5-14 is a plot of the aerodynamic mass-median diameter of the aerosol molecules as a function of time. As expected, the growth is approximately logarithmic, with deviations from this trend during the injection period. During this time, aerosols already in the containment vessel likely are experiencing rapid growth in size, while the aerosols continuously being injected from the reactor vessel are at their original, and smaller, size.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 102 Figure 5-14. Baseline case aerosol aerodynamic mass-median diameter Table 5-10 is a summary of example key concentration and removal rate parameters for all cases as calculated by STARNAUA. An unweighted average removal value is calculated for general information purposes.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 103 Table 5-10. Summary of key parameters from all cases Figure 5-15 and Figure 5-16 present plots of aerosol concentration and removal rate for all example cases, as calculated by STARNAUA. Figure 5-15. Comparison of aerosol concentration for all example cases versus time Parameter Average Removal Maximum Concentration Time of Max. Concentration Units (hr-1) (g/m3) (hr) Baseline 7.6 36.0 4.8 Sensitivity 1.3 19.0 29.8

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 104 Figure 5-16. Comparison of aerosol removal rate for example cases versus time An exponential decay of the postulated accident aerosol concentration through natural deposition removal mechanisms results in significant decontamination of airborne fission products in the containment vessel. Therefore, the example radiological consequences of the CDE are reduced as a result of the naturally occurring aerosol removal. Table 5-11. Summary of example aerosol removal results Parameter Units Value Peak Concentration g/cm3 36.0 Average Removal Rate hr-1 7.6 5.7 Example Core Damage Event Radiological Consequences With the example containment aerosol transport and removal calculations, including sensitivity case, the resulting control room and offsite radiological consequences are estimated in this section. These example calculations utilized dispersion factors based on meteorological data representative of an 80th-90th percentile site and the general methodologies described in Section 3.3 and Section 4.3, as applied to the example design. The same case matrix defined in Table 5-9 is utilized, with the example radiological consequences summarized in Table 5-12.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 105 Table 5-12. Summary of example RADTRAD case results Case Name Release Fractions Removal Rate Release Onset (hr) Release Duration (hr) Dose (rem TEDE) CR EAB LPZ Acceptance Criteria <5 <25 <25 Baseline Median Value Baseline 3.8 1.0 2.14 0.63 1.37 Sensitivity Case 5 Sensitivity 21.3 14.0 1.78 0.20 1.28 In all of the example cases, the acceptance criteria were satisfied. 5.8 Core Damage Source Term Sensitivity Analysis 5.8.1 General Sensitivity Analysis Methodology General sensitivity analysis methodologies are used throughout this section and are provided herein for reference. The sensitivity analyses are used in the accident radiological methodology to determine the appropriate biasing direction for an input, in order to obtain a conservative solution and to determine relative importance of the inputs. Another use of this sensitivity analysis is to check for the possibility of a non-linear system with corresponding feedback effects. Non-linear systems are checked for because parameter importance and bias directions are not consistent in such systems. Thus, in the case of a non-linear system, conditional bias directions have to be established in order to ensure a robust deterministic methodology. A review of the input parameters ranked in importance by linear, rank, and quadratic regression indicates clear consistency for each case individually, but also between different cases. This observation is a strong indication that the analysis of the NuScale design, as performed with a deterministic methodology, results in the modeled system behaving largely as a linear system (i.e., consistent importance and bias directions). A statistically based nonparametric input sampling process is implemented through automated software tools. Input parameters are randomly varied across their pertinent range of values within the input deck and run as a single sample whose output file gives a value. A statistically based nonparametric input sampling process is implemented through automated software tools. Input parameters are randomly varied across their pertinent range of values within the input deck and run as a single sample whose output file gives a value. Scatter plots are created to visually illustrate the sensitivity of the system to each individual input and sensitivity metrics are calculated to assist in identifying trends seen in the scatter plots. The partial rank correlation coefficient (PRCC) value is also calculated. A positive PRCC value means that the effect of the input on the output is the same (i.e., an increase of the value of the input leads to an increase of the value of the output). A negative PRCC value means the effect is the opposite (i.e., an increase in the input leads to a decrease in the output).

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 106 The primary indicator of importance is the incremental R2 from the quadratic regression model. An input is not sufficiently important if it has an incremental R2 less than 0.02. A high incremental R2 (close to 1.0) indicates that an input is highly influential on the evaluated system output. 5.8.2 Application to Core Damage Event Example calculations shown throughout Section 5.8 are based on the aerosol modeling methodology shown in Revisions 0-2 of this topical report and have not been updated to be consistent with the aerosol methodology in the current revision of this report. General sensitivity analysis methodologies are applied to the CDE radiological consequence calculation, including the aerosol modeling component, in order to provide a quantitative evaluation of the impact of aerosol modeling on the key output of the CDE radiological consequence calculation, which is the dose. The discussion on the results of the sensitivity analysis is focused on those inputs which are shown to be most influential on control room dose, LPZ dose, and aerosol removal rate. Exclusion area boundary dose is not included as it focuses only on the limiting two hour window. As the LPZ is assumed to be at the same distance as the EAB for this methodology, the cumulative LPZ dose is considered representative of EAB results. This consideration is made because the 0 to 2 hour sliding window EAB value is a single number that could occur at any point during the 30 day period, as opposed to the transient LPZ dose that continues to increase throughout the event, albeit at different rates during the transient. Table 5-13 presents the inputs sampled for the example sensitivity analysis utilizing uniform distributions. Minimum and maximum values of empirically observed aerosol parameters from core damage and aerosol specific experiments performed for LWRs are defined in Table 4-5. ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 107 (( Table 5-13. Summary of sampled input assumed for sensitivity analysis }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 108 (( Observations of the quadratic regression, PRCC, and adjusted R2 values for the example sensitivity analysis are described in the following paragraphs. In all cases the adjusted R2 indicated fair to good performance with quadratic values ranging approximately from 0.7 to 0.9, depending on the number and type of inputs for a case. Considering the fair to good performance of the adjusted R2, non-linear effects with respect to sensitivity analysis are ruled out, and the resulting sensitivity analysis is taken to be reasonable. A minimum of 1,000 samples were utilized in the analysis and taken to be appropriate based on acceptable adjusted R2 values. The quadratic regression criteria consistently aligned across all cases and with the PRCC rankings. ((

}}2(a),(c)

As noted previously, one use of this analysis is to check for the possibility of a non-linear system with corresponding feedback effects. Non-linear systems are checked for because parameter importance and bias directions are not consistent in such systems. Thus, in the case of a non-linear system, conditional bias directions would have to be established in order to ensure a robust deterministic methodology. ((

}}2(a),(c) 

}}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 109 ((

}}2(a),(c)

Table 5-14 and Table 5-15 present the key parameters (as defined by the quadratic regression criteria) for control room and LPZ dose results, assuming constant aerosol inputs. This case is used to set a baseline for the example sensitivity analysis and to provide context with respect to aerosol inputs. The resulting relative importance and bias directions are in alignment with expectations. Table 5-14. Key control room dose input rankings and bias directions Description Conservative Bias Rank PRCC Quadratic Incremental R2 CR in-leakage Larger 1 0.98 0.879 Release duration Smaller 2 -0.56 0.038 CR volume Smaller 3 -0.46 0.021 Release fractions Larger 4 0.43 0.020 Isotopic activity Larger 5 0.40 0.013 CNV leakage Larger 6 0.40 0.011 CR X/Q Larger 7 0.37 0.012 Table 5-15. Key low population zone dose input rankings and bias directions Description Conservative Bias Rank PRCC Quadratic Incremental R2 Release duration Smaller 1 -0.90 0.522 CNV leakage Larger 2 0.71 0.117 LPZ X/Q Larger 3 0.70 0.121 Release fractions Larger 4 0.69 0.121 Isotopic activity Larger 5 0.69 0.106

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 110 Figure 5-17 and Figure 5-18 present example control room and LPZ dose results assuming constant aerosol inputs in trace plot format. These plots show the transient progression for each individual trial shown in gray (only the first 200 trials are plotted for readability). The black dashed lines in the figures indicate the minimum and maximum values at any time during the transient. The blue solid line is the average value across all trials. The red dots show the absolute peak value found during each trial (only the first 200 are plotted for readability). Note that a significant inflection point in the example LPZ dose results occurs at eight hours. This occurrence is due to the change in atmospheric dispersion coefficients assumed in the period of 2 to 8 hours and 8 to 24 hours. There is no inflection point at 2 hours because the 0 to 2 hour and 2 to 8 hour factors vary by approximately 15 percent, within the range of the perturbation of these values and other parameters. However, the difference between the 2 to 8 hour and 8 to 24 hour value is significant (approximately 60 percent), and thus observable. This same inflection point is not observed in the example control room dose, even though there is a similar change in the dispersion factors, because the control room dispersion factors are of a much lower relative importance. Figure 5-17. Example control room dose trace plot (constant aerosol)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 111 Figure 5-18. Example low population zone dose trace plot (constant aerosol) Figure 5-19 and Figure 5-20 present bar charts of the calculated partial rank correlation coefficients, an indicator of the importance of an input, for control room and LPZ dose results assuming constant aerosol inputs. This information is the same information as presented in Table 5-14 and Table 5-15 in a visual format.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 112 Figure 5-19. Example control room dose sensitivity rankings (constant aerosol) Figure 5-20. Example low population zone dose sensitivity rankings (constant aerosol)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 113 Aerosol-specific inputs are added to the sensitivity analysis, with results presented in Table 5-16, Table 5-17, Figure 5-21, and Figure 5-22. The example LPZ dose results are described in the following paragraphs, which are representative of both control room and EAB radiological consequences. ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 114 Table 5-16. Key aerosol inputs for low population zone dose rankings and bias directions Description Conservative Bias Rank PRCC Quadratic Incremental R2 Release duration Smaller 1 -0.77 0.117 Packing fraction Smaller 2 -0.76 0.246 Mobility shape Larger 3 0.68 0.102 Geometric standard deviation Smaller 4 -0.63 0.100 Max bin radius Smaller 5 -0.50 0.060 Inert ratio Smaller 10 -0.37 0.026 Mean radius Smaller 11 -0.36 0.038 CNV volume Larger 12 0.32 <0.02 Sedimentation area Smaller 13 -0.29 <0.02 Table 5-17. Key aerosol concentration input rankings and bias directions Description Conservative Bias Rank PRCC Quadratic Incremental R2 Release duration Smaller 1 -0.90 0.470 Packing fraction Smaller 2 -0.76 0.159 Mobility shape Larger 3 0.71 0.079 Geometric standard deviation Smaller 4 -0.66 0.078 Max bin radius Smaller 5 -0.54 0.046 Mean radius Smaller 6 -0.40 0.019 Sedimentation area Smaller 7 -0.33 0.012 Inert ratio Smaller 9 0.12 <0.02

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 115 Figure 5-21. Low population zone dose trace plot Figure 5-22. Aerosol concentration trace plot

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 116 (( ((

}}2(a),(c) Table 5-18 provides the sensitivity analysis established bias directions for parameters to maximize dose and minimize aerosol removal.

Table 5-18. Direction of bias to maximize dose and minimize aerosol removal }}2(a),(c)

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 117 5.8.3 Sensitivity Analysis Conclusions Results from the example input sensitivity analysis performed for the CDE radiological consequence analysis are used in the methodology to determine the appropriate biasing direction for an input in order to yield a conservative solution. In addition, this example analysis may be utilized as a supporting determination of the linear nature with respect to sensitivity analysis (i.e., consistent biasing directions) of the system modeled. A high-level summary and conclusions of the example sensitivity analysis with respect to radiological consequences and aerosol removal is provided: ((

}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 118 5.9 Post-Accident pHT For illustrative purposes, the methodology of Section 4.4 was implemented to a scenario representative of a surrogate accident scenario. An example baseline and sensitivity calculation is provided in this section for context. An example baseline calculation provides a minimum pHT value of 6.7 inside containment, which is the assumed initial value. Note that at full operating conditions, the neutral pHT of the coolant is assumed to be 5.6. An estimate for iodine re-evolution can be made using Figure 4-18. According to this figure, less than 1 percent of aqueous iodine is assumed to be converted into molecular I2 at a pHT of 6.0. An example temperature sensitivity analysis demonstrates the importance of neutral pHT when determining whether the environment in containment is acidic or basic. As the temperature in containment increases, the neutral pHT of the coolant decreases while the actual value of pHT has remained relatively constant. At temperatures above 100°C, the environment inside containment will be basic. The results, calculated with the pHT computer code described in Section 3.1.7, of the example cases are summarized in Table 5-19. The example temperature sensitivity data is provided in Table 5-20 and includes how the neutral pHT of the coolant changes in acidity. Table 5-19. Summary of example pHT results for calculations performed at 25 degrees C Case Description Initial pHT Maximum pHT Minimum pHT Base Line 6.7 7.1 6.7 1000 ppm Boron 6.9 7.4 6.9 500 ppm Boron 7.1 7.9 7.1 200 ppm Boron 7.3 8.3 7.3 50% of CsOH 6.7 6.9 6.7 150% of CsOH 6.7 7.2 6.7 No Nitric or Hydrochloric Acid 6.7 7.1 6.7 Only Hydrochloric Acid 6.7 7.1 6.7 Both Nitric and Hydrochloric Acids 6.7 7.1 6.7 45,000 kg Liquid Coolant 6.6 7.0 6.6 30,000 kg Liquid Coolant 6.3 6.7 6.3

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 119 Table 5-20. Summary of example results for baseline calculation with increasing temperatures Case Description Initial pHT Maximum pHT Minimum pHT Neutral pHT Acid/Base at Minimum pHT 25° C 6.7 7.1 6.7 7.0 Acid 100° C 6.7 7.1 6.7 6.1 Base 200° C 6.9 7.3 6.9 5.6 Base The example baseline calculation uses conservative assumptions and inputs, resulting in coolant pHT plotted over 30 days (see Figure 5-23), with a final pHT of 7.1. Example conservative inputs for the baseline case are a coolant temperature of 25 degrees C, coolant mass of 53,400 kg, boron concentration of 1500 ppm, lithium concentration of 9.14 ppm, maximum iodine and cesium mass, and design basis containment doses. The boron concentration is assumed to vary between almost 1300 ppm at the beginning of an operating cycle to 5 ppm at the end of the cycle. Figure 5-23. The pHT of the coolant over a 30 day time period 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4 7.6 7.8 8.0 0 100 200 300 400 500 600 700 pHT at 25°C Time [Hours]

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 120 Example temperature sensitivity calculations are performed at 25 degrees C, 100 degrees C, and 200 degrees C across the 30 day time period (see Figure 5-24). At each temperature, the value of neutral pHT is plotted for comparison. Figure 5-24. Effect of elevated temperature on pHT 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 0 100 200 300 400 500 600 700 pHT Time [Hours] Base Line Neutral pHT at 25 C pHT at 100 C Neutral pHT at 100 C pHT at 200 C Neutral pHT at 200 C

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 121 Example boron sensitivity calculations were performed at 1000 ppm, 500 ppm, and 200 ppm (Figure 5-25). Figure 5-25. Sensitivity of pHT to boron concentration 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 0 100 200 300 400 500 600 700 pHT at 25°C Time [Hours] Base Line 1000 ppm Boron 500 ppm Boron 200 ppm Boron

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 122 Example cesium hydroxide sensitivity analysis was performed at 150 percent and 50 percent of the base line cesium hydroxide (Figure 5-26). Figure 5-26. Sensitivity of pHT to cesium hydroxide The example baseline calculation assumes only nitric acid is generated inside containment. Figure 5-27 evaluates how hydrochloric acid generation would affect pHT if halogen containing cable insulation was used inside containment. 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4 7.6 7.8 8.0 0 100 200 300 400 500 600 700 pHT at 25°C Time [Hours] Base Line 150% Cesium Hydroxide 50% Cesium Hydroxide

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 123 Figure 5-27. Sensitivity of pHT to nitric acid and hydrochloric acid 6.6 6.7 6.8 6.9 7.0 7.1 7.2 7.3 7.4 7.5 7.6 0 100 200 300 400 500 600 700 pHT at 25°C Time [Hours] Base Line No Additional Acids Hydrochloric Acid Only Both Nitric and Hydrochloric Acids

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 124 Example coolant mass sensitivity was evaluated at a liquid coolant mass of 45,000 kg and 30,000 kg (Figure 5-28). Figure 5-28. Sensitivity of pHT to the mass of liquid coolant in containment 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4 7.6 7.8 8.0 0 100 200 300 400 500 600 700 pHT at 25°C Time [Hours] Base Line 45,000 kg Coolant 30,000 kg Coolant

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 125 6.0 Summary and Conclusions A methodology for developing accident source terms and performing the corresponding radiological consequence analyses was presented in this report. The methodology was shown to be conservative by providing example results from sensitivity analyses. Key unique features of the methodology presented in this report are the use of ARCON96 for offsite atmospheric dispersion factors, the development of an iodine spike DBST and CDST which together meet 10 CFR 52.47 (a)(2)(iv), the utilization of STARNAUA containment aerosol transport code in the range of NuScales expected post-accident containment conditions, and evaluation of post-accident pHT. ARCON96 was found to be suitably conservative for NuScales intended use of the code as a substitute for PAVAN for offsite atmospheric dispersion factor calculations. As presented in this report, the ARCON96 methodology has less of a tendency to over-predict concentrations, while still providing predictions that are sufficiently conservative. The STARNAUA containment aerosol transport and removal code was benchmarked against experimental data and was shown to be appropriate for modeling aerosol removal in the CDE radiological consequence analysis associated with the post-accident containment conditions. Consistent with RG 1.183, the assumption that no iodine decontamination factor limit should be applied to natural aerosol removal phenomenon was utilized for modeling removal in the containment vessel. Through example sensitivity analysis on the modeling parameters utilized as input to the STARNAUA code, ((

}}2(a),(c) This insight provides confidence that the aerosol modeling methodology is robust and the inputs utilized for the CDE radiological consequence analysis are conservative.

Example calculations were provided in order to demonstrate applicability of the methodology. 6.1 Criteria for Establishing Applicability of Methodologies The generalized methodologies presented in this topical report are based upon numerous modeling assumptions. For completeness, the following set of criteria for establishing the applicability of these methodologies is provided. The application that utilizes the methodology of this topical report must satisfy these criteria in order to establish applicability. Any deviations to these criteria must be explicitly defined and justified as part of the application that references this topical report. 6.1.1 Criteria for Atmospheric Dispersion Factors

1. ((
}}2(a),(c)
3. Ground level release.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 126

4. ((
}}2(a),(c) 6.1.2 Criteria for Core Radionuclide Inventory
1. ((
}}2(a),(c) 6.1.3 Criteria for Control Room Modeling
1. ((
}}2(a),(c) 

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 127 7.0 References 7.1 Source Documents 7.1.1 American Society of Mechanical Engineers, Quality Assurance Requirements for Nuclear Facility Applications, NQA-1-2008, NQA-1a-2009 Addenda, as endorsed by Regulatory Guide 1.28, Revision 4. 7.1.2 U.S. Code of Federal Regulations, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Facilities, Appendix B, Part 50, Chapter 1, Title 10, Energy, (10 CFR 50). 7.1.3 NuScale Licensing Topical Report, Quality Assurance Program Description for the NuScale Power Plant, NP-TR-1010-859-NP-A, Revision 3, December 2016. 7.1.4 NuScale Licensing Document, Accident Source Term Regulatory Framework, WP-0318-58980, Revision 1, LO-0119-64373, (ML19032A146) January 31, 2019. 7.2 Referenced Documents 7.2.1 U.S. Code of Federal Regulations, Title 10, Part 52. 7.2.2 U.S. Nuclear Regulatory Commission, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors, Regulatory Guide 1.183, Revision 0, July 2000. 7.2.3 U.S. Code of Federal Regulations, Title 10, Part 50. 7.2.4 U.S. Code of Federal Regulations, Title 10, Part 100. 7.2.5 U.S. Nuclear Regulatory Commission, Accident Source Terms for Light-Water Nuclear Power Plants, NUREG-1465, February 1995. 7.2.6 U.S. Nuclear Regulatory Commission, Meteorological Monitoring Programs for Nuclear Power Plants, Regulatory Guide 1.23, Revision 1, March 2007. 7.2.7 U.S. Nuclear Regulatory Commission, Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants, Regulatory Guide 1.145, Revision 1, February 1983. 7.2.8 U.S. Nuclear Regulatory Commission, Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants, Regulatory Guide 1.194, Revision 0, June 2003. 7.2.9 U.S. Nuclear Regulatory Commission, Methods and Assumptions for Evaluating Radiological Consequences of Design Basis Accidents at Light-Water Nuclear Power Reactors, Regulatory Guide 1.195, Revision 0, May 2003.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 128 7.2.10 Sandia National Laboratories, Accident Source Terms for Light-Water Nuclear Power Plants Using High-Burnup or MOX Fuel, SAND2011-0128, Revision 0, January, 2011. 7.2.11 U.S. Nuclear Regulatory Commission, Experience with Implementation of Alternative Source Terms, RIS 2006-04, March 7, 2006. 7.2.12 U.S. Nuclear Regulatory Commission, Evaluation of Fission Product Release and Transport for a Fuel Handling Accident, October 1971. 7.2.13 Gauntt, R.O., Cole, R.K., Erickson, C.M., Gido, R.G., Gasser, R.D., Rodriguez, S.B., and Young, M.F., MELCOR Computer Code Manuals, NUREG/CR-6119, Sandia National Laboratories, December 2000. 7.2.14 U.S. Nuclear Regulatory Commission, Standard Review Plan Onsite Meteorological Measurements Programs, NUREG-0800, Section 2.3.3, Revision 3, March 2007. 7.2.15 Ramsdell, J.V., Jr. and Stage, S.A., Computer Codes for Evaluation of Control Room Habitability (HABIT V1.1), NUREG/CR-6210, Supplement 1, Pacific Northwest National Laboratory, October 1998. 7.2.16 U.S. Nuclear Regulatory Commission, Policy Issues Related to Licensing Non-Light-Water Reactor Designs, Commission Paper SECY-03-0047, March 28, 2003. 7.2.17 U.S. Nuclear Regulatory Commission, Second Status Report on the Staffs Proposed Regulatory Structure for New Plant Licensing and Update on Policy Issues Related to New Plant Licensing, Commission Paper SECY-05-0006, January 7, 2005. 7.2.18 DiNunno, J.J., Baker, R.E., Anderson, F.D., and Waterfield, R.L., Calculation of Distance Factors for Power and Test Reactor Sites, TID-14884, March 1962. 7.2.19 U.S. Nuclear Regulatory Commission, Source Term-Related Technical and Licensing Issues Pertaining to Evolutionary and Passive Light-Water-Reactor Designs, SECY-94-302, December 19, 1994. 7.2.20 Nuclear Energy Institute, Small Modular Reactor Source Terms, December 27, 2012. 7.2.21 U.S. Nuclear Regulatory Commission, Control Room Habitability at Light-Water Nuclear Power Reactors, Regulatory Guide 1.196, Revision 1, January 2007. 7.2.22 Bander, T.J., PAVAN: An Atmospheric Dispersion Program for Evaluating Design Basis Accidental Release of Radioactive Materials from Nuclear Power Stations, NUREG/CR-2858, Pacific Northwest National Laboratory, November 1982.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 129 7.2.23 Ramsdell, J.V., Jr. and Fosmire, C.J., Atmospheric Dispersion Estimates in the Vicinity of Buildings, Pacific Northwest Laboratory, PNL-10286, January 1995. 7.2.24 Ramsdell, J.V., Jr. and Simonen, C.A., Atmospheric Relative Concentrations in Building Wakes, Pacific Northwest National Laboratory, NUREG/CR-6331, Revision 1, May 1997. 7.2.25 Oak Ridge National Laboratory, SCALE: A Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and Design, ORNL/TM-2005/39, Version 6, Volumes I-III, January 2009. 7.2.26 U.S. Nuclear Regulatory Commission, PAVAN: An Atmospheric-Dispersion Program for Evaluating Design-Basis Accidental Releases of Radioactive Materials from Nuclear Power Stations, NUREG/CR-2858, Revision 0, November 1982. 7.2.27 MCNP5/MCNPX (MCNP5 Version 1.51 and MCNPX Version 2.6.0) [Software]. Oak Ridge, TN: Radiation Safety Information Computational Center, 2009. 7.2.28 U.S. Nuclear Regulatory Commission, Evolutionary Light Water Reactor (LWR) Certification Issues and their Relationships to Current Regulatory Requirements, Commission Paper SECY-90-016, January 12, 1990. 7.2.29 U.S. Nuclear Regulatory Commission, Use of Alternative Source Terms at Operating Reactors, Federal Register, Volume 64, No. 246, p. 71990, December 23, 1999. 7.2.30 Reserved. 7.2.31 U.S. Nuclear Regulatory Commission, RADTRAD: A Simplified Model for RADionuclide Transport and Removal and Dose Estimation, Supplement 1 (June 1999), Supplement 2 (October 2002), NUREG/CR-6604, Revision 0, April 1998. 7.2.32 U.S. Nuclear Regulatory Commission, Reactor Site Criteria Including Seismic and Earthquake Engineering Criteria for Nuclear Power Plants, Federal Register, 61 FR 65176, December 11, 1996. 7.2.33 U.S. Atomic Energy Commission, Calculation of Distance Factors for Power and Test Reactors, TID-14844, March 23, 1962. 7.2.34 U.S. Nuclear Regulatory Commission, Memorandum from J. Uhle to C. Paperiello, Results of Initial Screening of Generic Issue 197 Iodine Spiking Phenomena, Dated May 8, 2006. 7.2.35 U.S. Nuclear Regulatory Commission, NRC Action Plan Developed as a Result of the TMI-2 Accident, NUREG-0660, May 1980.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 130 7.2.36 U.S. Nuclear Regulatory Commission, Staff Discussion of Fifteen Technical Issues Listed in Attachment to November 3, 1976 Memorandum from Director, NRR to NRR Staff, NUREG-0138, November 1976. 7.2.37 U.S. Nuclear Regulatory Commission, Clarification of TMI Action Plan Requirements, NUREG-0737, November 1980. 7.2.38 U.S. Environmental Protection Agency, Limiting Values of Radionuclide Intake And Air Concentration and Dose Conversion Factors For Inhalation, Submersion And Ingestion: Federal Guidance Report No. 11, EPA-520-1-88-020, September 1988. 7.2.39 U.S. Environmental Protection Agency, External Exposure to Radionuclides in Air, Water and Soil: Federal Guidance Report No. 12, EPA-402-R-93-081, September 1993. 7.2.40 National Institute of Standards and Technology, Thermodynamic Properties of Water: Tabulation from the IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use, NISTIR-5078, October 1998. 7.2.41 U.S. Environmental Protection Agency, PCRAMMET Users Guide, EPA-454/ B-96-001, June 1999. 7.2.42 Electric Power Research Institute, Advanced Light Water Reactor Utility Requirements Document, Revision 8, March 1999. 7.2.43 Sher, R. and Hobbins, R., Transport and Removal of Aerosols in Nuclear Power Plants Following Severe Accidents, American Nuclear Society, 2011. 7.2.44 Organization for Economic Cooperation and Development, State-of-the-Art Report on Nuclear Aerosols, NEA/CSNI/R(2009)5, December 2009. 7.2.45 Rudolph Sher Associates, NAUAHYGROS - A Code for Calculating Aerosol Behavior in Nuclear Power Plant Containments Following a Severe Accident, Proc. of the 23rd DOE/NRC Nuclear Air Cleaning Conference, Buffalo, NY, July 25-28,1994, pp.520-538, NUREG/CP-0141, CONF-940738, U.S. Nuclear Regulatory Commission, February 1995. 7.2.46 U.S. Nuclear Regulatory Commission, Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Boiling Water Reactors, Regulatory Guide 1.3, Rev. 2, June 1974. 7.2.47 Talbot, L., Cheng, R. K., Schefer, R. W., and Willis, D. R. (1980). Thermophoresis of Particles in a Heated Boundary Layer, Journal of Fluid Mechanics. Volume 101, Part 4, 737-758.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 131 7.2.48 U.S. Nuclear Regulatory Commission, Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Pressurized Water Reactors, Regulatory Guide 1.4, Rev. 2, June 1974. 7.2.49 U.S. Nuclear Regulatory Commission, A Simplified Model of Aerosol Removal by Natural Processes in Reactor Containments, NUREG/CR-6189, July 1996. 7.2.50 Wilson, J.H. and Arwood, P.C., Comparison of (Posttest) Predictions of Aerosol Codes with Measurements in LWR Aerosol Containment Experiment (LACE) LA4, LACE TR-084 ORNL/M-991, Oak Ridge National Laboratory, February 1990. 7.2.51 Tobias, M.L., Comparison Of Aerosol Code Predictions With Experimental Observations On The Behavior Of Aerosols In Steam, CONF-831014317, presented at the 11th Water Reactor Safety Research Information Meeting at the National Bureau of Standards, Gaithersburg, Maryland, October 14, 1983. 7.2.52 U.S. Nuclear Regulatory Commission, Iodine Evolution and pH Control, NUREG/CR-5950, Revision 3, December 1992. 7.2.53 U.S. Nuclear Regulatory Commission, Post-Accident Gas Generation from Radiolysis of Organic Materials, NUREG-1081, Revision 0, September 1984. 7.2.54 Electric Power Research Institute, PWR Primary Water Chemistry Guidelines, Volume 1, Revision 4, 2000. 7.2.55 Whitten, K. W., Davis, R. E., Peck, M. L., and Stanley, G. G. Chemistry (Eighth Edition). Thomson Brooks/Cole, 2007. 7.2.56 Butler, James N., Ionic Equilibrium: Solubility and pH Calculations. John Wiley & Sons, Inc., New York: 1998. 7.2.57 Kekki, T. and Zilliacus, R., Formation of nitric acid during high gamma dose radiation, VTT-R-00774-11, VTT Technical Research Centre of Finland. 7.2.58 Murphy, K. G., Campe, K. M., Nuclear Power Plant Control Room Ventilation System Design for Meeting General Design Criterion 19, Proceedings of the 13th AEC Air Cleaning Conference, CONF-740807, U.S. Atomic Energy Commission, Washington, DC, 1974. 7.2.59 J. E. Cline and Associates, Report to USNRC, MSIV Leakage and Iodine Transport Analysis, March 26, 1991. 7.2.60 U.S. Nuclear Regulatory Commission, Postulated Radioactive Releases Due to Liquid-Containing Tank Failures - Review Responsibilities, Branch Technical Position (BTP 11-6), March 2007.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 132 7.2.61 International Commission on Radiological Protection, Conversion Coefficients for use in Radiological Protection against External Radiation, ICRP Publication

74. Ann. ICRP 26 (3-4), 1996.

7.2.62 U.S. Nuclear Regulatory Commission, Functional Criteria for Emergency Response Facilities, NUREG-0696, February 1981. 7.2.63 Mitchell, A. E. Jr., A comparison of short-term dispersion estimates resulting from various atmospheric stability classification methods, Atmospheric Environment, (1982): 16:765-773. 7.2.64 U.S. Environmental Protection Agency. (2015). Observational Meteorological Data. Retrieved from http://www3.epa.gov/ttn/scram/metobsdata.htm. 7.2.65 Gelbard, F., MAEROS User Manual, NUREG/CR-1391, Sandia National Laboratory, December 1982.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 133 Appendix A. Regulatory Assessment of Design-Basis and Beyond-Design-Basis Source Terms The NuScale accident source term methodology distinguishes between design-basis source terms (DBSTs) and the beyond-design-basis core damage source term (CDST). This distinction is made in order to facilitate decoupling the CDST from SSC design and performance requirements for which consideration of a less severe source term is reasonable and appropriate. 10 CFR 52.47(a)(2)(iv) originated as a siting requirement in 10 CFR 100.11, which defined the necessary exclusion area and low population zone for a facility based primarily on the core size and site conditions. TID-14844 (Reference 7.2.33) was developed to loosely encompass the postulated releases evaluated in early license applications. This reflected a realistic appraisal of the consequences of all significant and credible fission release possibilities, and yielded a pipe rupture-meltdown sequence not likely to be exceeded by any other credible accident. As reactors became larger, fission product mitigation systems eventually became the dominant factor in meeting the dose limits. Therefore, the core melt source term became the basis for design, performance, and qualification for SSCs relied upon in mitigating fission product releases in order to meet the offsite dose criteria. This requirement is reflected in the definition of safety related SSC under 10 CFR 50.2, and related requirements (e.g. 10 CFR 50 Appendix B). In 1997, the requirement was moved to safety analysis report requirements (10 CFR 50.34 et al) to reflect its primary role as the design basis for ESFs. Following the Three Mile Island accident, the core melt source terms of RGs 1.3 and 1.4 (based on TID-14844) that were developed for siting purposes served as a well-established, surrogate, degraded core event for designing and demonstrating enhanced severe accident mitigation capabilities for operating facilities. This same source term was also utilized for environmental qualification under 10 CFR 50.49, which addresses both qualification of SSCs that are relied on to mitigate offsite radiological consequences from the design-basis core melt MHA (i.e., safety-related functions), as well as enhanced instrumentation requirements implemented to enhance severe accident capabilities following TMI (i.e., nonsafety-related post-accident monitoring instrumentation). Thus, the TID-14844 core melt accident, originally postulated for purposes of a siting evaluation, became a design-basis requirement for numerous SSC design and performance requirements associated with both safety-related and nonsafety-related functions. Under NuScales methodology, the iodine spike DBST is analyzed as a design-basis event and the CDST as a beyond-design-basis event. The design-basis iodine spike DBST and the beyond-design-basis CDST are each assessed against the radiological criteria of 10 CFR 52.47(a)(2)(iv). If both the design-basis iodine spike DBST and the beyond-design-basis CDST analyses show acceptable dose

results, 10 CFR 52.47(a)(2)(iv) is met. The analysis of the beyond-design-basis CDST against the acceptance criteria of 10 CFR 52.47(a)(2)(iv) provides reasonable assurance that, even in the extremely unlikely event of a severe accident, the facilitys design features and site characteristics provide adequate protection of the public. The dose analysis for

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 134 the beyond-design-basis CDST can use assumptions and methods different than those used for design-basis dose analyses if sufficient justification is provided by the application referencing this report. The classification of CDE as beyond-design-basis is appropriate in order to consistently define the design basis of the plant. Treatment of the CDE as a design-basis accident for some purposes but not others would create an inconsistency in the implementation of regulations. For example, classification of the CDE as a design-basis event for the purposes of the offsite dose evaluation would indicate that SSCs relied upon in meeting the offsite dose limits are performing safety-related functions and subject to environmental qualification for CDE conditions under 10 CFR 50.49. By evaluating both a design-basis and beyond-design basis source term instead of a single design-basis core melt source term, requirements that prescribe the design, quality, and performance of plant features that mitigate the radiological consequences of the respective events are implemented in a manner commensurate with the importance of the safety functions to be performed, consistent with GDC 1. Given the use of two source terms to meet 10 CFR 52.47(a)(2)(iv), Table A-1 describes how pertinent requirements are met without a design-basis core damage event.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 135 Table A-1 Summary of Pertinent Requirements Requirement Summary History/Intent Methodology Compliance 10 CFR 52.47(a)(2)(iv), offsite dose evaluation Analyze an assumed fission product release into containment to determine offsite radiological consequences are within acceptable limits. Footnote: The fission product release assumed for this evaluation should be based upon a major accident, hypothesized for purposes of site analysis or postulated from considerations of possible accidental events. These accidents have generally been assumed to result in substantial meltdown of the core with subsequent release into the containment of appreciable quantities of fission products. Originated as a siting requirement in 10 CFR 100.11, which defined the necessary exclusion area and low population zone for a facility based primarily on the core size and site conditions. As reactors became larger, fission product mitigation systems eventually became the dominant factor in meeting the dose limits. In 1997 the requirement was moved to safety analysis report requirements (10 CFR 50.34 et al) to reflect its primary role as ESF design-basis. The design-basis iodine spike DBST and the beyond-design-basis CDST are each assessed against the radiological criteria of 10 CFR 52.47(a)(2)(iv) to demonstrate that plant features and postulated site parameters limit the offsite radiological consequences of accidents. If both the design-basis iodine spike DBST and the beyond-design-basis CDST analyses show acceptable dose results, 10 CFR 52.47(a)(2)(iv) is met. General Design Criterion (GDC) 19, control room habitability A control room shall be provided from which actions can be taken under accident conditions. Adequate radiation protection shall be provided to permit access and occupancy of the control room under accident conditions without personnel receiving radiation exposures in excess of 5 rem whole body, or its equivalent to any part of the body, for the duration of the accident. Provide reasonable assurance of operator safety while performing actions to mitigate accidents, such that the operator actions are not inhibited. Because the core damage event is normally treated as a DBE with respect to fission product mitigation systems, the core damage event is also normally considered for control room dose to assure operators can perform necessary functions in such an event. Radiological consequences of design-basis events, including the iodine spike DBST, are assessed against GDC 19. As a beyond-design-basis event, GDC 19 is not directly applicable to the CDST. However, pursuant to 10 CFR 50.34(f)(2)(vii) the GDC 19 design dose criterion is applicable to the CDST, as discussed in the Table A-1 entry for 10 CFR 50.34(f)(2)(vii) below.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 136 Requirement Summary History/Intent Methodology Compliance 10 CFR 50.49, environmental qualification Design certification applicants must identify, and license applicants must establish a program for qualifying, electric equipment important to safety, including safety-related and certain nonsafety-related electric equipment, and certain post-accident monitoring equipment. The qualification program must include the radiation environment associated with the most severe design basis accident during or following which the equipment is required to remain functional. Rule development began before, but concluded after, the Three Mile Island (TMI) accident. The safety-related electric equipment relied upon for design-basis events includes SSCs (e.g. fission product mitigation ESFs and supporting features) for which the design-basis was the MHA, so they were required to be qualified for the MHA. The rule also includes qualification of certain post-accident monitoring (PAM), as addressed by Regulatory Guide (RG) 1.97. Design-basis events are used to meet 10 CFR 50.49. The beyond-design-basis core damage event is not considered for 10 CFR 50.49. In SECY-90-016 (Reference 7.2.28) NRC Staff acknowledged that the stringent safety-related requirements, including 10 CFR 50.49, were not commensurate with the importance of the safety functions to be performed during severe accident mitigation, and recommended relaxed requirements for assuring SSC functionality during a severe accident.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 137 Requirement Summary History/Intent Methodology Compliance 10 CFR 50.34(f)(2)(vii), shielding for vital access and safety equipment 10 CFR 50.34(f)(2)(viii), post-accident sampling Perform radiation and shielding design reviews of spaces around systems that may, as a result of an accident, contain accident source term11 radioactive materials Provide a capability to promptly obtain and analyze samples from the reactor coolant system and containment that may contain accident source term11 radioactive materials without exceeding specified worker dose limits. TMI Items II.B.2 and II.B.3. Per NUREG-0660 (Reference 7.2.35), these Items were short term actions intended to enhance public safety by reducing risk from core degradation accidents, which can lead to containment failure and large releases. NUREG-0737 (Reference 7.2.37) specified an assumption of the RG 1.3 (Reference 7.2.46) or RG 1.4 (Reference 7.2.48) source term (based on TID-14844) as the accident conditions for demonstrating these severe accident capabilities. The CDST is considered as an "accident source term" in addressing these requirements, consistent with the intent to address core degradation accidents. As discussed in NUREG-0737, Item II.B.2, the "adequate access to important areas" provision of 10 CFR 50.34(f)(2)(vii) is satisfied by demonstrating that personnel can perform necessary severe accident mitigation functions--including occupancy of the control room and technical support center--without exceeding the GDC 19 dose design criterion. As a beyond-design-basis event, the control room and technical support center doses may be analyzed with less conservatism than a design-basis analysis, where adequately justified. Protection of necessary equipment from radiation is reasonably assured through demonstrating equipment survivability. The required capability for post-accident sampling or the design dose criterion for obtaining samples may be affected by design-specific features that support an exemption from 10 CFR 50.34(f)(2)(viii).

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 138 Requirement Summary History/Intent Methodology Compliance 10 CFR 50.34(f)(2)(xix), core damage monitoring Provide instrumentation adequate for monitoring plant conditions following an accident that includes core damage. TMI Item II.F.3. The II.F Items aimed to provide instrumentation to monitor plant variables and systems during and following an accident. Item II.F.3 concerned instrumentation to support unplanned action ifa safety system is not functioning and action necessary to protect the public and for an estimate of the magnitude of the impending threat. The requirement is also implemented via RG 1.97 (in addition to 10 CFR 50.49 PAM requirements), which addresses the expanded ranges and damaged core source term to provide reasonable assurance of the required severe accident capabilities. In SECY-90-016, staff addressed the issue of assuring that severe accident mitigation features are demonstrated to be available to perform their functions. Staff concluded that severe accident mitigation features must be designed so there is reasonable assurance that they will operate in the severe-accident environment for which they are intended and over the time span for which they are needed. Staff concluded that features provided for only severe accident protection were not subject to safety-related requirements such as 10 CFR 50.49 environmental qualification and Appendix B quality assurance. Applications referencing this topical report will provide an equipment survivability evaluation that provides reasonable assurance necessary instrumentation will operate over the time span for which they are needed.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 139 Requirement Summary History/Intent Methodology Compliance 10 CFR 50.34(f)(2)(xxvi), leakage control outside containment 10 CFR 50.34(f)(2)(xxviii), control room leakage Provide for leakage control and detection in the design of systems outside containment that contain (or might contain) accident source term11 radioactive materials following an accident. Evaluate potential pathways for radioactivity and radiation that may lead to control room habitability problems under accident conditions resulting in an accident source term11 release, and make necessary design provisions to preclude such problems. TMI Item III.D.1.1 and III.D.3.4. The III.D Items addressed design features that will reduce the potential for exposure to workers at nuclear power plants and to offsite populations following an accident. Item III.D.1.1 was a radiological release source control measure, that required licensees to reduce leakage to the extent practical for all systems that could carry radioactive fluid outside of containment, without regard to a particular source term. Item III.D.3.4 was part of worker radiation protection improvements to allow workers to take effective action to control the course and consequences of an accident. The subsequent rulemaking included a core damage source term in both requirements to address potential new leakage paths from the addition of severe accident mitigation features, and provide reasonable assurance of control room habitability that would be needed to operate those features. The CDST is considered as an "accident source term" in addressing 10 CFR 50.34(f)(2)(xxvi), consistent with the intent to address core degradation accidents. The assessment of control room radiological consequences for the beyond-design-basis CDE pursuant to 10 CFR 50.34(f)(2)(vii) also satisfies 10 CFR 50.34(f)(2)(xxviii) by considering potential control room leakage pathways.

Accident Source Term Methodology TR-0915-17565-NP Rev. 3 © Copyright 2019 by NuScale Power, LLC 140 Requirement Summary History/Intent Methodology Compliance 10 CFR Part 50 Appendix E, paragraph IV.E.8, Technical Support Center (TSC) A licensee must provide and describe in their emergency plan an onsite technical support center and an emergency operations facility from which effective direction can be given and effective control can be exercised during an emergency. TMI Item III.A.1.2 identified the need for upgraded emergency response facilities (ERFs) to improve the inadequate state of emergency planning and preparedness. Specified a TSC as a place for management and technical personnel to support reactor control functions, to evaluate and diagnose plant conditions, and for a more orderly conduct of emergency operations. NUREG-0696 (Reference 7.2.62) describes the functional criteria for ERFs, including the TSC, including dose criteria equivalent to the control room. The design referencing this report will provide a TSC and an evaluation of the radiological consequences of the beyond-design-basis core damage event against 10 CFR 50.34(f)(2)(vii) that provides reasonable assurance that the TSC will be habitable. Note: The footnote in Table A-1 refers to footnote 11 in 10 CFR 50.34.

LO-0419-65235 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com : Affidavit of Thomas A. Bergman, AF-0419-65236

AF-0419-65236 Page 1 of 2 NuScale Power, LLC AFFIDAVIT of Thomas A. Bergman I, Thomas A. Bergman, state as follows: (1) I am the Vice President of Regulatory Affairs of NuScale Power, LLC (NuScale), and as such, I have been specifically delegated the function of reviewing the information described in this Affidavit that NuScale seeks to have withheld from public disclosure, and am authorized to apply for its withholding on behalf of NuScale (2) I am knowledgeable of the criteria and procedures used by NuScale in designating information as a trade secret, privileged, or as confidential commercial or financial information. This request to withhold information from public disclosure is driven by one or more of the following: (a) The information requested to be withheld reveals distinguishing aspects of a process (or component, structure, tool, method, etc.) whose use by NuScale competitors, without a license from NuScale, would constitute a competitive economic disadvantage to NuScale. (b) The information requested to be withheld consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), and the application of the data secures a competitive economic advantage, as described more fully in paragraph 3 of this Affidavit. (c) Use by a competitor of the information requested to be withheld would reduce the competitors expenditure of resources, or improve its competitive position, in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product. (d) The information requested to be withheld reveals cost or price information, production capabilities, budget levels, or commercial strategies of NuScale. (e) The information requested to be withheld consists of patentable ideas. (3) Public disclosure of the information sought to be withheld is likely to cause substantial harm to NuScales competitive position and foreclose or reduce the availability of profit-making opportunities. The accompanying report reveals distinguishing aspects about the methodology by which NuScale develops its accident source term. NuScale has performed significant research and evaluation to develop a basis for this methodology and has invested significant resources, including the expenditure of a considerable sum of money. The precise financial value of the information is difficult to quantify, but it is a key element of the design basis for a NuScale plant and, therefore, has substantial value to NuScale. If the information were disclosed to the public, NuScale's competitors would have access to the information without purchasing the right to use it or having been required to undertake a similar expenditure of resources. Such disclosure would constitute a misappropriation of NuScale's intellectual property, and would deprive NuScale of the opportunity to exercise its competitive advantage to seek an adequate return on its investment. (4) The information sought to be withheld is in the enclosed report entitled Accident Source Term Methodology. The enclosure contains the designation Proprietary" at the top of each page containing proprietary information. The information considered by NuScale to be proprietary is identified within double braces, "(( }}" in the document. (5) The basis for proposing that the information be withheld is that NuScale treats the information as a trade secret, privileged, or as confidential commercial or financial information. NuScale relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC §

AF-0419-65236 Page 2 of 2 552(b)(4), as well as exemptions applicable to the NRC under 10 CFR §§ 2.390(a)(4) and 9.17(a)(4). (6) Pursuant to the provisions set forth in 10 CFR § 2.390(b)(4), the following is provided for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld: (a) The information sought to be withheld is owned and has been held in confidence by NuScale. (b) The information is of a sort customarily held in confidence by NuScale and, to the best of my knowledge and belief, consistently has been held in confidence by NuScale. The procedure for approval of external release of such information typically requires review by the staff manager, project manager, chief technology officer or other equivalent authority, or the manager of the cognizant marketing function (or his delegate), for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside NuScale are limited to regulatory bodies, customers and potential customers and their agents, suppliers, licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or contractual agreements to maintain confidentiality. (c) The information is being transmitted to and received by the NRC in confidence. (d) No public disclosure of the information has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or contractual agreements that provide for maintenance of the information in confidence. (e) Public disclosure of the information is likely to cause substantial harm to the competitive position of NuScale, taking into account the value of the information to NuScale, the amount of effort and money expended by NuScale in developing the information, and the difficulty others would have in acquiring or duplicating the information. The information sought to be withheld is part of NuScale's technology that provides NuScale with a competitive advantage over other firms in the industry. NuScale has invested significant human and financial capital in developing this technology and NuScale believes it would be difficult for others to duplicate the technology without access to the information sought to be withheld. I declare under penalty of perjury that the foregoing is true and correct. Executed on April , 2019. Thomas A. Bergman the foregoing is true and correct. E Thomass A. Bergman}}