ML19095A445

From kanterella
Jump to navigation Jump to search
Response to IE Bulletin Nos. 77-05,77-05A, & NRC Letter of 11/18/1977, Enclosed Study Results Regarding Environmental Qualifications of Electrical Connectors
ML19095A445
Person / Time
Site: Surry  
Issue date: 12/07/1977
From: Stallings C
Virginia Electric & Power Co (VEPCO)
To: O'Reilly J
NRC/RGN-II
References
IEB-77-005, IEB-77-005A, Serial No. 529/111877
Download: ML19095A445 (3)


Text

i

  • ('

luLAroRv *~0&1filf1ff tor/

VIRGINIA ELEC:'i:RIC.A.ND POWER *coMPAN~-.' si' RIOHMOND,VIRGINI.A 23261

  • oecember7; 1977 Mr. James -P. O'Reilly, Director Office of Inspection and Enforcement
u. s. Nuclear Regulatory* Commission Region II 230 Peachtree St~eet, Northwest Atlanta, Georgia 30303

Dear Mr. O'Reiily:

Serial No.** 529/111877 LQA/JEE:jal *.

Docket Nose 50-280 50-281 Thi~ letter is in response to IE l3ulletin Nos*. 77-05 and* 77-0SA and Mr. Case's letter' of November 18, 1977*, concerning environmental

_ qualifications of elect~ical connectors subject to an accident environ-ment and are required to be operable during an accident.

A_ s1;:udy has

  • been conducted and we have.found that the.only electrical con~ectors required for safety are the channels needed for reactor trip during a LOCA - low pressurizer level and low pressurizer pressure..These channels would actuate a reactor.a~d turbine trip within the first a~conda well before accident.radiation levels are.reached or the commencement of caustic sprays. therefore, these connectors (manufactured.by Amphenol)'
  • w~uld not be exposed to high radiation or caustic sprays before their function was completed.*

on* November 16, 1977, our Messrs. W'" F. Bennett-and J.M.. Davis met with Messrs. T. A~ Ippolito and M*. B. Fairtile when test results on the Amphenol connectors for accident steam. temperature, and pressure conditions.were present'ed~

  • The staff found the* results acceptable. A

_ brief description of _ the test is attached.

It is our conclusion.that no other electrical connectors inside or outside the containment would be required to function. during an accident.**

The Amphenol Connectors.described abiove-.will not be required to operate -

beyond the first seconds into_the accident before further degradation of the containment environment and would not compromise the-operation of safety-related equipment..

Attachment

  • cc:

Mr.. Robert w. Reid/

. Very

  • truly yours,.

. _ Zp_ )/)?. \\,dl/dh;~ 7r

  • C. M *. Stallings
  • Vice President-Power Supply and Production Operations

d j

e e

DESCRIPTION OF TEST Amphenol Connectors used at Surry Units 1 and 2:

1.

280°F at 60 psia for 60 min.

2~

140-150°F at atmospheric for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

RESULTS:

Insulation Resistance never fell below 34.SM~.

't.~

,,