Unit #2 - 2R20 Steam Generator 180 Day Report Attachment A BEAVER VALLEY UNIT #2 2R20 SG EXAMINATION RESULTS 2RCS-SG21A TUBES WITH SERVICE INDUCED INDICATIONS
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 3
ONI 04H
-0.01 1.67 23 P1 08H TEH 74 NQI 07H 45.70 1.52 96 3
08H TEH 1
78 SCI TSH
-0.09 0.20 120 0.92 0.16 79 P2 TSH TSH 2
24 OSI 07H
-0.03 0.32 95 P1 08H TEH 2
37 SCI TSH
-0.13 0.10 78 0.60 0.11 48 P2 TSH TSH 2
59 SCI TSH
-0.09 0.20 40 0.31 0.08 72 P2 TSH TSH 2
60 PSI 03C 0.52 16.50 163 8
08C TEC 2
87 ONI 05H
-0.03 1.68 49 P1 08H TEH 2
88 OSI 02H
-0.01 0.21 105 P1 08H TEH 2
88 ONI 06H 0.00 1.68 42 P1 08H TEH 2
89 ONI 07H 0.00 1.14 58 P1 08H TEH 2
92 OSI 03H
-0.06 0.36 103 P1 08H TEH 3
2 PSI 02H 0.38 15.30 161 8
08H TEH 3
15 OSI 03H 0.05 0.31 115 P1 08H TEH 3
15 ONI 07H 0.00 1.31 47 P1 08H TEH 3
17 ONI 06H 0.00 1.27 53 P1 08H TEH 3
23 ONI 07C
-0.02 1.27 43 P1 08C TEC 3
24 ONI 07C 0.00 1.33 52 P1 08C TEC 3
26 ONI 03H 0.00 2.48 40 P1 08H TEH 3
27 ONI 07H 0.00 1.25 44 P1 08H TEH 3
45 ONI 03H 0.15 2.05 20 P1 08H TEH 3
58 SCI TSH
-0.08 0.18 71 0.54 0.17 110 P2 TSH TSH 3
59 SCI TSH 0.00 0.00 58 0.45 0.11 81 P2 TSH TSH 3
59 OSI 02H 0.20 0.46 48 P1 08H TEH 3
60 SCI TSH
-0.05 0.18 69 0.53 0.17 67 P2 TSH TSH 3
65 OSI 07H
-0.01 0.72 81 P1 08H TEH 3
71 ONI 08H 0.00 1.35 39 P1 08H TEC 3
71 ONI 08H 0.13 1.33 36 P1 08H TEH 3
77 OSI 08H
-0.27 0.43 53 P1 08H TEH 3
77 SAi 08H 0.00 0.31 25 0.19 0.09 124 P4 08H 08H 3
79 OSI 07H
-0.23 0.44 144 P1 08H TEH 3
81 ONI 08C 0.03 1.47 42 P1 08C TEC 3
81 OSI 03H
-0.01 0.56 106 P1 08H TEH 3
81 ONI 07H 0.01 1.58 50 P1 08H TEH 3
84 OSI 03H
-0.04 0.50 72 P1 08H TEH 3
85 OSI 04H 0.10 0.66 57 P1 08H TEH 3
91 ONI 04H o:oo 1.31 40 P1 08H TEH 3
92 OSI 02H 0.06 0.19 158 P1 08H TEH 4
9 ONI 07C
-0.03 1.65 43 P1 08C TEC 4
9 ONI 06C 0.00 1.39 39 P1 08C TEC 4
9 ONI 08H 0.00 1.43 34 P1 08H 07C 4
9 OSI 03H
-0.04 0.90 87 P1 08H TEH 4
9 OSI 04H 0.03 0.20 82 P1 08H TEH 4
9 ONI 06H 0.00 1.39 53 P1 08H TEH Page 1 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 4
9 DNI 07H
-0.07 1.39 54 P1 08H TEH 4
9 DNI 08H 0.00 1.34 43 P1 08H TEH 4
18 DSI 05H
-0.28 0.34 126 P1 08H TEH 4
21 DSI 03H
-0.06 0.35 82 P1 08H TEH 4
22 DNI 07H 0.06 1.45 37 P1 08H TEH 4
24 DSI 02H
-0.08 0.25 102 P1 08H TEH 4
26 DSI 02H
-0.06 0.23 100 P1 08H TEH 4
26 DNI 03H 0.19 1.44 30 P1 08H TEH 4
28 DSI 03H
-0.07 0.54 65 P1 08H TEH 4
33 DNI 07H 0.01 1.29 53 P1 08H TEH 4
34 DSI 03H
-0.34 0.40 99 P1 08H TEH 4
34 DNI 07H 0.00 1.36 47 P1 08H TEH 4
39 DSI 02H 0.00 0.06 71 P1 08H TEH 4
40 SCI TSH
-0.03 0.50 111 0.85 0.10 65 P2 TSH TSH 4
50 DSI 02H 0.06 0.28 79 P1 08H TEH 4
50 DSI 03H 0.04 0.70 58 P1 08H TEH 4
50 DSI 04H
-0.04 0.39 40 P1 08H TEH 4
54 DNI 08C
-0.02 1.42 47 P1 08C TEC 4
54 DSI 02H 0.00 0.30 46 P1 08H TEH 4
54 DSI 04H 0.07 0.31 87 P1 08H TEH 4
54 DSI 05H 0.00 0.37 115 P1 08H TEH 4
56 SCI TSH
-0.07 0.17 69 0.53 0.11 106 P2 TSH TSH 4
59 SCI TSH
-0.05 0.12 115 0.88 0.15 94 P2 TSH TSH 4
60 SCI TSH
-0.08 0.22 145 1.10 0.31 98 P2 TSH TSH 4
60 DSI 02H 0.03 0.26 143 P1 08H TEH 4
60 DSI 06H 0.00 0.32 36 P1 08H TEH 4
61 SCI TSH
-0.11 0.17 58 0.45 0.08 85 P2 TSH TSH 4
62 DNI 02H
-0.01 1.50 44 P1 08H TEH 4
62 DNI 03H
-0.12 1.76 46 P1 08H TEH 4
62 DNI 04H 0.18 1.46 14 P1 08H TEH 4
62 DNI 05H 0.22 1.38 21 P1 08H TEH 4
63 DSI 02H 0.03 0.34 54 P1 08H TEH 4
64 SCI TSH
-0.08 0.20 108 0.82 0.10 64 P2 TSH TSH 4
70 DSI 03H 0.03 0.18 60 P1 08H TEH 4
72 DNI 08C
-0.12 1.48 40 P1 08C TEC 4
72 DNI 08H 0.00 1.34 51 P1 08H TEH 4
78 DSI 05H
-0.03 0.22 114 P1 08H TEH 4
83 PSI 03H 0.19 15.06 157 8
08H TEH 4
85 DSI 08C
-0.07 0.11 120 P1 08C TEC 4
86 DSI 03H 0.06 0.19 127 P1 08H TEH 5
4 DNI 07H
-0.05 1.37 42 P1 TEH TEC 5
7 DNI 06H 0.00 1.30 53 P1 TEH TEC 5
10 DSI 02H 0.00 0.72 81 P1 TEH TEC 5
10 DSI 03H
-0.10 0.85 120 P1 TEH TEC Page 2 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 5
10 OSI 04H 0.00 0.46 93 P1 TEH TEC 5
11 OSI 04H 0.02 0.31 47 P1 TEH TEC 5
12 ONI 07H 0.02 1.30 58 P1 TEH TEC 5
12 ONI 08H 0.00 1.75 36 P1 TEH TEC 5
12 ONI 08C
-0.02 1.56 38 P1 TEH TEC 5
13 ONI 06H
-0.03 1.76 21 P1 08H TEH 5
18 SAi 06H
-0.05 0.31 52 0.40 0.23 93 6
06H 06H 5
18 OSI 06H
-0.05 0.51 23 P1 TEH TEC 5
18 ONI 08H 0.08 1.63 32 P1 TEH TEC 5
25 ONI 06C 0.00 1.73 26 P1 08C TEC 5
25 OSI 05H 0.00 0.56 107 P1 08H TEH 5
25 ONI 06H 0.03 1.93 39 P1 08H TEH 5
25 ONI 08H 0.00 1.47 42 P1 08H TEH 5
26 OSI 02H 0.00 0.51 147 P1 08H TEH 5
26 OSI 03H
-0.20 0.32 81 P1 08H TEH 5
26 ONI 07H 0.00 1.35 52 P1 08H TEH 5
28 SCI TSH 0.00 0.08 98 0.75 0.27 59 P2 TSH TSH 5
28 OSI 04H
-0.19 1.46 37 P1 08H TEH 5
29 SAi 02H
-0.19 0.34 23 0.18 0.21 61 6
02H 02H 5
29 OSI 02H
-0.12 1.18 104 P1 TEH TEC 5
29 ONI 06C
-0.02 1.47 29 P1 TEH TEC 5
30 OSI 03H 0.03 0.15 35 P1 08H TEH 5
31 ONI 07C 0.00 1.29 51 P1 TEH TEC 5
35 ONI 04H 0.15 1.35 31 P1 TEH TEC 5
53 OSI 02H 0.22 0.57 120 P1 TEH TEC 5
53 ONI 04H
-0.02 1.35 51 P1 TEH TEC 5
53 ONI 07H 0.00 1.37 45 P1 TEH TEC 5
56 SCI TSH 0.00 0.18 186 1.42 0.50 136 P2 TSH TSH 5
59 SCI TSH
-0.01 0.18 80 0.61 0.20 95 P2 TSH TSH 5
61 PSI 07H
-0.49 15.46 164 8
TEH TEC 5
71 ONI 08H 0.03 1.56 46 P1 TEH TEC 5
72 SCI TSH
-0.15 0.19 105 0.80 0.19 91 P2 TSH TSH 5
79 ONI 06H 0.00 1.28 52 P1 TEH TEC 5
80 OSI 05H 0.07 0.17 100 P1 TEH TEC 5
82 OSI 03H 0.00 0.27 119 P1 TEH TEC 6
10 SCI TSH
-0.11 0.17 171 1.30 0.30 73 P2 TSH TSH 6
11 ONI 06H 0.00 1.57 41 P1 TEH TEC 6
12 ONI 07H 0.00 1.44 44 P1 TEH TEC 6
14 ONI 06H 0.00 1.35 47 P1 TEH TEC 6
15 OSI 02H 0.10 0.34 124 P1 TEH TEC 6
15 ONI 03H 0.15 1.25 54 P1 TEH TEC 6
15 ONI 08H 0.02 1.35 46 P1 TEH TEC 6
17 ONI 04H 0.10 1.34 53 P1 TEH TEC 6
20 OSI 04H
-0.02 0.36 84 P1 TEH TEC Page 3 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 6
20 ONI 08H 0.05 1.32 52 P1 TEH TEC 6
27 OSI 06H 0.00 0.24 88 P1 TEH TEC 6
27 ONI 07H
-0.02 2.07 34 P1 TEH TEC 6
27 ONI 05C
-0.02 1.42 32 P1 TEH TEC 6
29 ONI 08H 0.00 1.27 46 P1 TEH TEC 6
32 OSI 02H 0.00 0.21 148 P1 TEH TEC 6
33 SCI TSH 0.00 0.13 118 0.90 0.20 100 P2 TSH TSH 6
33 ONI 08H 0.00 1.38 31 P1 TEH TEC 6
34 OSI 02H 0.00 0.56 155 P1 TEH TEC 6
34 ONI 08H 0.00 1.45 46 P1 TEH TEC 6
35 SCI TSH 0.00 0.16 105 0.80 0.10 93 P2 TSH TSH 6
35 OSI 02H
-0.05 1.14 104 P1 TEH TEC 6
35 OSI 03H
-0.03 0.31 97 P1 TEH TEC 6
35 OSI 05H
-0.05 0.47 78 P1 TEH TEC 6
35 OSI 08H 0.00 0.42 51 P1 TEH TEC 6
35 ONI 08H 0.08 1.27 54 P1 TEH TEC 6
35 SAi 02H
-0.20 0.13 26 0.20 0.11 115 6
02H 02H 6
36 ONI 08H 0.00 1.51 45 P1 TEH TEC 6
37 ONI 04C 0.00 1.70 14 P1 TEH TEC 6
40 OSI 03H
-0.05 0.26 144 P1 TEH TEC 6
40 OSI 04H 0.05 0.29 142 P1 TEH TEC 6
40 ONI 07C 0.00 1.59 41 P1 TEH TEC 6
40 ONI 05C
-0.02 1.25 35 P1 TEH TEC 6
40 ONI 02C
-0.09 1.42 25 P1 TEH TEC 6
41 OSI 08H 0.16 0.25 24 P1 TEH TEC 6
41 SAi TSH 0.89 0.27 69 0.53 0.14 87 6
TSH TSH 6
41 SAi 08H
-0.03 0.35 42 0.32 0.12 77 6
08H 08H 6
43 OSI 02H 0.00 0.30 85 P1 TEH TEC 6
43 ONI 05H
-0.02 1.41 42 P1 TEH TEC 6
43 ONI 06H
-0.02 1.38 43 P1 TEH TEC 6
43 ONI 07H 0.02 1.39 52 P1 TEH TEC 6
59 SCI TSH
-0.08 0.25 148 1.13 0.19 60 P2 TSH TSH 6
63 ONI 08H
-0.05 1.35 45 P1 TEH TEC 6
68 ONI 05H 0.02 1.56 51 P1 TEH TEC 6
68 ONI 06H 0.02 1.36 55 P1 TEH TEC 6
68 ONI 07H 0.02 1.75 45 P1 TEH TEC 7
4 ONI 06H
-0.02 1.55 52 P1 TEH TEC 7
4 ONI 07H
-0.02 1.34 49 P1 TEH TEC 7
6 ONI 04H
-0.05 1.88 50 P1 TEH TEC 7
7 ONI 04H 0.14 1.27 24 P1 TEH TEC 7
14 OSI 03H 0.17 0.23 119 P1 TEH TEC 7
18 OSI 02H
-0.03 0.26 80 P1 TEH TEC 7
18 OSI 03H
-0.05 0.35 111 P1 TEH TEC 7
18 OSI 05H
-0.08 0.34 139 P1 TEH TEC Page 4 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 7
19 OSI 02H 0.00 0.46 124 P1 TEH TEC 7
19 OSI 03H 0.05 0.44 91 P1 TEH TEC 7
19 ONI 07H 0.00 1.29 51 P1 TEH TEC 7
22 MCI TSH
-0.19 0.05 111 0.85 0.10 99 P2 TSH TSH 7
27 OSI 05H 0.10 0.42 152 P1 TEH TEC 7
31 ONI 04H
-0.05 1.31 41 P1 TEH TEC 7
31 ONI 07H
-0.02 1.82 36 P1 TEH TEC 7
31 ONI 07C
-0.22 1.36 28 P1 TEH TEC 7
31 ONI 05C 0.10 1.87 12 P1 TEH TEC 7
33 SCI TSH
-0.13 0.10 25 0.19 0.10 134 P2 TSH TSH 7
40 SCI TSH
-0.13 0.19 100 0.76 0.10 88 P2 TSH TSH 7
47 ONI 04H 0.00 1.42 10 P1 TEH TEC 7
49 OSI 02H 0.05 0.17 126 P1 TEH TEC 7
49 ONI 05H 0.02 1.39 25 P1 TEH TEC 7
49 ONI 07H
-0.02 1.38 40 P1 TEH TEC 7
51 OSI 02H
-0.03 0.20 34 P1 STH TEC 7
51 OSI 05H 0.03 0.53 69 P1 STH TEC 7
57 ONI 02H
-0.20 1.30 41 P1 STH TEC 7
57 ONI 04H 0.15 1.42 19 P1 STH TEC 7
57 ONI 05H 0.20 1.72 30 P1 STH TEC 7
57 ONI 07H
-0.05 1.40 22 P1 STH TEC 7
60 ONI 03H
-0.05 1.32 24 P1 TEH TEC 7
68 SCI TSH
-0.17 0.19 109 0.83 0.15 105 P2 TSH TSH 7
72 ONI 04H 0.02 1.46 48 P1 TEH TEC 7
72 ONI 06H 0.00 1.25 50 P1 TEH TEC 7
79 SCI TSH
-0.04 0.20 269 2.06 0.21 63 P2 TSH TSH 7
83 ONI 08H 0.03 1.43 48 P1 TEH TEC 7
83 ONI 07C 0.00 1.33 50 P1 TEH TEC 7
87 ONI 07H 0.00 1.53 50 P1 TEH TEC 7
94 OSI 02H 0.02 0.20 161 P1 TEH TEC 8
2 ONI 05H 0.03 1.40 55 P1 TEH TEC 8
6 ONI 04H 0.15 1.56 31 P1 TEH TEC 8
13 ONI 06H 0.02 1.28 53 P1 STH TEC 8
17 ONI 05H 0.00 1.25 49 P1 TEH TEC 8
19 OSI 02H
-0.02 0.39 112 P1 TEH TEC 8
28 OSI 02H
-0.03 0.26 85 P1 STH TEC 8
28 ONI 07H 0.00 1.29 54 P1 STH TEC 8
28 ONI 08H 0.00 1.46 40 P1 STH TEC 8
29 OSI 02H
-0.03 0.26 143 P1 STH TEC 8
32 SAi 05H 0.06 0.41 29 0.22 0.09 96 6
05H 05H 8
32 OSI 03H
-0.05 0.33 83 P1 TEH TEC 8
32 OSI 05H 0.03 0.34 34 P1 TEH TEC 8
32 ONI 07H 0.00 1.44 20 P1 TEH TEC 8
32 ONI 08H 0.00 1.82 29 P1 TEH TEC Page 5 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 8
33 ONI 07C 0.20 1.29 11 P1 STH TEC 8
34 OSI 03H
-0.20 0.88 52 P1 TEH TEC 8
40 ONI 05C
-0.02 1.42 27 P1 TEH TEC 8
40 SCI TSH
-0.08 0.69 152 1.16 0.08 97 P2 TSH TSH 8
42 DSI 02H 0.02 0.15 134 P1 STH TEC 8
42 ONI 08H 0.02 1.27 44 P1 STH TEC 8
50 SCI TSH
-0.08 0.15 52 0.40 0.08 112 P2 TSH TSH 8
52 SCI TSH
-0.09 0.17 98 0.75 0.13 98 P2 TSH TSH 8
54 SCI TSH 0.00 0.15 215 1.64 0.11 79 P2 TSH TSH 8
55 SCI TSH
-0.01 0.20 46 0.35 0.12 68 P2 TSH TSH 8
56 DNI 08H 0.00 1.32 41 P1 STH TEC 8
59 DNI 08H 0.02 1.34 52 P1 TEH TEC 8
59 ONI 03C 0.00 1.28 21 P1 TEH TEC 8
61 SCI TSH
-0.10 0.22 149 1.14 0.13 91 P2 TSH TSH 8
65 ONI 07H 0.00 1.40 52 P1 TEH TEC 8
65 DNI 08H 0.02 1.30 48 P1 TEH TEC 8
65 ONI 07C 0.00 1.32 45 P1 TEH TEC 8
66 ONI 06H 0.10 1.39 40 P1 TEH TEC 8
66 ONI 08H
-0.02 1.45 45 P1 TEH TEC 8
67 OSI 02H
-0.02 0.25 125 P1 TEH TEC 8
69 DSI 02H 0.00 0.26 140 P1 TEH TEC 8
69 ONI 08H 0.00 1.25 54 P1 TEH TEC 8
74 ONI 03H 0.00 1.37 55 P1 TEH TEC 8
74 ONI 07H 0.02 1.34 45 P1 TEH TEC 8
74 ONI 08H 0.03 1.26 44 P1 TEH TEC 8
76 DSI 05H 0.02 0.18 106 P1 TEH TEC 8
79 DNI 08H 0.15 1.28 25 P1 TEH TEC 8
85 OSI 02H
-0.03 0.07 134 P1 TEH TEC 8
91 OSI 04H
-0.03 0.28 96 P1 TEH TEC 9
3 ONI 05H
-0.04 1.25 48 P1 TEH TEC 9
4 DNI 06H 0.02 1.42 55 P1 TEH TEC 9
4 DNI 07H 0.00 1.27 52 P1 TEH TEC 9
7 DNI 07H 0.02 1.37 46 P1 TEH TEC 9
7 ONI 08H
-0.07 1.35 41 P1 TEH TEC 9
10 OSI 02H
-0.07 0.91 113 P1 TEH TEC 9
10 DNI 05H
-0.05 1.28 53 P1 TEH TEC 9
10 DNI 06H 0.00 1.46 49 P1 TEH TEC 9
12 DNI 06H
-0.02 1.33 47 P1 TEH TEC 9
13 OSI 02H
-0.08 0.27 100 P1 TEH TEC 9
13 DNI 08H 0.00 1.27 46 P1 TEH TEC 9
14 OSI 03H 0.00 0.13 75 P1 TEH TEC 9
14 ONI 07H
-0.03 1.27 46 P1 TEH TEC 9
16 DSI 02H
-0.03 0.41 147 P1 TEH TEC 9
16 DSI 03H 0.02 0.42 60 P1 TEH TEC Page 6 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 9
16 OSI 04H 0.00 0.44 146 P1 TEH TEC 9
18 OSI 05H
-0.05 0.30 92 P1 TEH TEC 9
25 ONI 05C
-0.05 1.40 36 P1 TEH TEC 9
27 ONI 03H 0.02 1.54 55 P1 TEH TEC 9
28 ONI 07H 0.05 1.40 52 P1 TEH TEC 9
28 ONI 08C 0.00 1.53 39 P1 TEH TEC 9
28 ONI 07C 0.05 1.25 42 P1 TEH TEC 9
29 ONI 06H 0.00 1.55 45 P1 TEH TEC 9
31 ONI 06H 0.02 1.30 24 P1 STH TEC 9
33 ONI 08H 0.10 1.31 22 P1 TEH TEC 9
34 SAi 02H
-0.24 0.13 29 0.22 0.12 49 P4 02H 02H 9
34 OSI 02H 0.07 0.27 140 P1 TEH TEC 9
34 ONI 06C
-0.05 1.32 32 P1 TEH TEC 9
35 OSI 02H 0.00 0.35 143 P1 TEH TEC 9
35 ONI 08H 0.00 1.28 48 P1 TEH TEC 9
35 ONI 06C 0.21 1.29 21 P1 TEH TEC 9
35 SCI TSH 0.00 0.37 117 0.89 0.19 60 P2 TSH TSH 9
37 ONI 04H 0.00 1.80 30 P1 TEH TEC 9
37 ONI 05H 0.00 1.64 18 P1 TEH TEC 9
37 ONI 06H
-0.02 1.86 30 P1 TEH TEC 9
37 ONI 07H
-0.17 1.76 16 P1 TEH TEC 9
37 ONI 08H 0.05 1.89 28 P1 TEH TEC 9
37 ONI 02C
-0.25 1.59 9
P1 TEH TEC 9
38 OSI 05H
-0.10 0.60 159 P1 TEH TEC 9
40 OSI 03H 0.02 0.35 107 P1 TEH TEC 9
40 ONI 06H 0.02 1.29 54 P1 TEH TEC 9
40 ONI 07H 0.05 1.57 40 P1 TEH TEC 9
40 ONI 08H 0.02 1.27 43 P1 TEH TEC 9
-0.05 33 0.36 56 6
TSC TSC 9
42 VOL TSC
-0.05 0.21 55 0.42 0.36 56 6
TSC TSC 9
49 ONI 08H 0.20 1.57 28 P1 TEH TEC 9
51 OSI 04H
-0.12 0.52 100 P1 STH TEC 9
51 SAi 04H
-0.06 0.17 29 0.22 0.11 94 2
04H 04H 9
56 OSI 02H
-0.08 0.20 83 P1 TEH TEC 9
56 OSI 04H 0.02 0.23 71 P1 TEH TEC 9
56 ONI 06H 0.00 1.25 48 P1 TEH TEC 9
57 OSI 02H
-0.24 0.74 136 P1 TEH TEC 9
57 OSI 03H
-0.12 0.31 101 P1 TEH TEC 9
58 SCI TSH 0.00 0.00 82 0.62 0.22 105 P2 TSH TSH 9
59 ONI 07H 0.00 1.37 53 P1 TEH TEC 9
62 ONI 05H
-0.02 1.27 47 P1 TEH TEC 9
62 ONI 08H
-0.02 1.31 54 P1 TEH TEC 9
68 SCI TSH
-0.09 0.17 226 1.73 0.22 97 P2 TSH TSH 9
74 OSI 03H
-0.02 0.21 146 P1 TEH TEC Page 7 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW {Inches) {Degrees) {Inches) VOL TS {Degrees) CHAN FROM TO 9
75 SCI TSH
-0.15 0.22 142 1.08 0.18 122 P2 TSH TSH 9
83 PSI 04H
-0.07 8.60 72 8
TEH TEC 10 4
DNI 06H 0.00 1.38 53 P1 TEH TEC 10 7
DSI 02H
-0.10 0.38 86 P1 TEH TEC 10 7
DSI 03H 0.00 0.32 126 P1 TEH TEC 10 7
DNI 06H 0.02 1.61 49 P1 TEH TEC 10 8
DSI 03H 0.00 0.26 71 P1 TEH TEC 10 10 DNI 07H 0.00 1.49 45 P1 TEH TEC 10 12 DNI 06H 0.00 1.40 26 P1 TEH TEC 10 12 DNI 07H 0.00 1.63 21 P1 TEH TEC 10 15 DNI 05H 0.00 1.35 54 P1 TEH TEC 10 15 DNI 07H 0.00 1.44 50 P1 TEH TEC 10 18 DNI 06H 0.00 1.39 39 P1 TEH TEC 10 19 DSI 04H
-0.05 0.25 107 P1 TEH TEC 10 20 DNI 04H 0.20 1.33 23 P1 TEH TEC 10 26 DSI 04H 0.00 0.12 82 P1 TEH TEC 10 29 DNI 07H
-0.16 1.62 19 P1 TEH TEC 10 32 DNI 08C 0.15 1.89 17 P1 TEH TEC 10 34 DSI 04H 0.02 0.77 19 P1 TEH TEC 10 34 SAi 04H 0.08 0.29 45 0.34 0.10 104 6
04H 04H 10 37 DSI 03H
-0.02 0.10 89 P1 TEH TEC 10 37 DNI 05C 0.00 1.31 29 P1 TEH TEC 10 40 SCI TSH 0.02 0.17 34 0.26 0.16 91 P2 TSH TSH 10 47 DNI 04H 0.02 1.36 48 P1 TEH TEC 10 47 DNI 05H 0.05 1.44 37 P1 TEH TEC 10 47 DNI 06H 0.05 1.67 26 P1 TEH TEC 10 47 DNI 07H
-0.12 1.47 20 P1 TEH TEC 10 47 DNI 07C 0.00 1.33 25 P1 TEH TEC 10 49 DNI 08C 0.00 1.37 31 P1 STH TEC 10 49 DNI 07C 0.05 1.44 45 P1 STH TEC 10 57 DNI 02H
-0.22 1.72 21 P1 TEH TEC 10 57 DNI 03H 0.00 1.48 31 P1 TEH TEC 10 57 DNI 04H 0.00 1.61 32 P1 TEH TEC 10 57 DNI 05H 0.05 1.77 27 P1 TEH TEC 10 57 DNI 06H
-0.10 1.26 24 P1 TEH TEC 10 57 DNI 07H 0.02 1.79 34 P1 TEH TEC 10 57 DNI 08H
-0.15 1.35 27 P1 TEH TEC 10 58 DSI 04H 0.00 0.17 31 P1 TEH TEC 10 58 DNI 07C 0.00 1.63 17 P1 TEH TEC 10 63 SCI TSH
-0.10 0.00 145 1.10 0.11 89 P2 TSH TSH 10 64 DNI 02H 0.00 1.67 8
P1 TEH TEC 10 64 DNI 03H 0.00 1.32 23 P1 TEH TEC 10 64 DNI 05C
-0.17 1.34 18 P1 TEH TEC 10 69 DNI 04H 0.00 2.50 10 P1 TEH TEC Page 8 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 10 69 ONI 06C 0.10 1.46 10 P1 TEH TEC 10 72 ONI 07C 0.00 1.40 15 P1 TEH TEC 10 83 ONI 04C
-0.09 1.45 19 P1 TEH TEC 10 86 ONI 08C
-0.03 1.32 35 P1 TEH TEC 10 89 ONI 05H 0.27 1.91 12 P1 TEH TEC 10 89 ONI 06H
-0.03 2.15 27 P1 TEH TEC 10 89 ONI 07H
-0.08 1.54 37 P1 TEH TEC 10 89 ONI 08C
-0.16 1.38 26 P1 TEH TEC 10 89 ONI 07C
-0.07 1.18 32 P1 TEH TEC 11 2
OSI 03H 0.00 0.68 101 P1 TEH TEC 11 3
ONI 04H 0.02 2.08 44 P1 TEH TEC 11 3
ONI 05H
-0.02 1.66 48 P1 TEH TEC 11 3
ONI 07H
-0.03 1.38 48 P1 TEH TEC 11 3
ONI 08H
-0.10 2.12 29 P1 TEH TEC 11 5
ONI 04H 0.02 2.05 46 P1 TEH TEC 11 5
ONI 05H 0.00 1.90 45 P1 TEH TEC 11 5
ONI 06H
-0.02 1.43 57 P1 TEH TEC 11 5
ONI 07H
-0.02 1.32 49 P1 TEH TEC 11 7
ONI 02H 0.15 1.31 9
P1 TEH TEC 11 12 ONI 05H 0.00 1.72 47 P1 STH TEC 11 12 ONI 07H 0.00 1.39 50 P1 STH TEC 11 12 ONI 08H
-0.02 1.60 44 P1 STH TEC 11 12 ONI 02C
-0.05 1.45 20 P1 STH TEC 11 20 ONI 06H 0.03 1.54 47 P1 TEH TEC 11 20 ONI 07H
-0.02 1.32 48 P1 TEH TEC 11 20 ONI 08C 0.00 1.32 47 P1 TEH TEC 11 24 ONI 04H 0.12 1.29 26 P1 TEH TEC 11 29 ONI 07H 0.00 1.32 35 P1 TEH TEC 11 37 MCI TSH
-0.13 0.69 152 1.16 0.21 107 P2 TSH TSH 11 48 MCI TSH
-0.04 0.36 157 1.20 0.06 77 P2 TSH TSH 11 48 OSI 02H 0.00 0.69 62 P1 TEH TEC 11 48 ONI 06H 0.05 1.96 38 P1 TEH TEC 11 48 ONI 07H 0.05 2.21 37 P1 TEH TEC 11 48 OSI 08H 0.05 0.35 77 P1 TEH TEC 11 48 ONI 04C 0.02 1.87 27 P1 TEH TEC 11 48 ONI 03C 0.00 1.57 21 P1 TEH TEC 11 48 ONI 02C
-0.02 1.38 18 P1 TEH TEC 11 52 MCI TSH 0.00 0.00 194 1.48 0.23 97 P2 TSH TSH 11 58 SCI TSH
-0.05 0.16 45 0.34 0.09 84 P2 TSH TSH 11 59 SCI TSH
-0.04 0.18 126 0.96 0.25 81 P2 TSH TSH 11 60 SCI TSH
-0.10 0.26 125 0.95 0.34 86 P2 TSH TSH 11 62 SCI TSH
-0.10 0.18 123 0.94 0.24 96 P2 TSH TSH 11 74 ONI 07H 0.00 1.52 54 P1 TEH TEC 11 76 ONI 03H 0.00 1.35 52 P1 TEH TEC Page 9 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 11 77 DNI 03H 0.12 1.30 55 P1 TEH TEC 11 77 DSI 05H 0.02 0.39 73 P1 TEH TEC 11 77 DNI 06H 0.02 1.76 54 P1 TEH TEC 11 78 DSI 05H 0.05 0.15 61 P1 TEH TEC 11 78 DSI 06H
-0.05 0.21 24 P1 TEH TEC 11 79 DNI 07C 0.00 1.30 45 P1 TEH TEC 11 80 DNI 06H 0.27 1.57 15 P1 TEH TEC 11 80 DNI 03C
-0.05 1.32 18 P1 TEH TEC 12 3
DNI 07H 0.03 1.20 11 P1 TEH TEC 12 6
DNI AV4 6.87 0.22 115 5
TEH TEC 12 7
DNI 04H 0.09 1.31 7
P1 TEH TEC 12 7
DNI 06H 0.14 1.44 11 P1 TEH TEC 12 7
DNI 04C 0.19 1.47 7
P1 TEH TEC 12 16 SAi 02H
-0.34 0.23 32 0.25 0.15 106 P4 02H 03H 12 16 DSI 02H
-0.18 0.47 146 P1 TEH TEC 12 16 DNI 07H 0.00 1.50 44 P1 TEH TEC 12 19 DNI 07H 0.13 1.35 14 P1 TEH TEC 12 19 DNI 08C
-0.07 1.34 13 P1 TEH TEC 12 19 DNI 06C
-0.27 1.57 7
P1 TEH TEC 12 19 DNI 05C
-0.02 1.92 22 P1 TEH TEC 12 20 DNI 05H 0.05 1.53 46 P1 TEH TEC 12 23 DNI 02C 0.33 1.68 16 P1 TEH TEC 12 26 DNI 05H
-0.03 1.32 11 P1 TEH TEC 12 27 DNI 05H 0.12 1.47 17 P1 TEH TEC 12 32 DNI 08C
-0.05 1.19 36 P1 TEH TEC 12 34 DSI 02H 0.00 0.26 91 P1 TEH TEC 12 34 DNI 06H 0.00 1.93 41 P1 TEH TEC 12 38 DNI 06H 0.02 1.29 31 P1 TEH TEC 12 39 SCI TSH
-0.05 0.17 125 0.95 0.25 91 P2 TSH TSH 12 44 SCI TSH
-0.10 0.12 134 1.02 0.10 96 P2 TSH TSH 12 48 DSI 05H
-0.05 0.28 52 P1 TEH TEC 12 53 SCI TSH
-0.06 0.12 38 0.29 0.11 114 P2 TSH TSH 12 60 SCI TSH
-0.12 0.12 57 0.43 0.08 132 P2 TSH TSH 12 64 DNI 04H 0.02 1.80 48 P1 TEH TEC 12 64 DNI 07H 0.00 1.59 51 P1 TEH TEC 12 64 DNI 08C
-0.05 1.27 49 P1 TEH TEC 12 64 DNI 03C 0.00 1.40 10 P1 TEH TEC 12 67 DNI 08C
-0.02 1.32 41 P1 TEH TEC 12 69 DSI 02H 0.05 0.33 60 P1 TEH TEC 12 69 DSI 03H
-0.02 0.23 107 P1 TEH TEC 12 69 DNI 08C
-0.02 1.35 37 P1 TEH TEC 12 70 DSI 03H 0.05 0.28 120 P1 TEH TEC 12 71 DNI 08H
-0.07 1.60 42 P1 TEH TEC 12 71 DNI 07C 0.02 1.32 41 P1 TEH TEC Page 10 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 12 71 ONI 06C 0.00 1.78 33 P1 TEH TEC 12 72 OSI 02H
-0.03 0.31 142 P1 TEH TEC 12 72 ONI 05H 0.00 1.61 53 P1 TEH TEC 12 73 OSI 05H 0.07 0.16 123 P1 TEH TEC 12 73 ONI 06H 0.00 1.36 56 P1 TEH TEC 12 73 ONI 07H 0.00 1.62 45 P1 TEH TEC 12 74 OSI 02H
-0.18 0.32 136 P1 TEH TEC 12 74 OSI 03H 0.00 0.51 66 P1 TEH TEC 12 74 ONI 07H 0.00 1.48 50 P1 TEH TEC 12 74 ONI 07C 0.00 1.32 43 P1 TEH TEC 12 75 ONI 02H 0.00 2.15 44 P1 TEH TEC 12 75 ONI 03H 0.00 1.73 45 P1 TEH TEC 12 75 ONI 04H 0.19 1.65 35 P1 TEH TEC 12 75 ONI 05H 0.09 1.78 28 P1 TEH TEC 12 75 ONI 06H
-0.03 1.48 43 P1 TEH TEC 12 75 ONI 06C
-0.05 1.60 32 P1 TEH TEC 12 75 ONI 05C 0.00 1.28 48 P1 TEH TEC 12 75 ONI 04C 0.09 1.83 16 P1 TEH TEC 12 78 ONI 06C
-0.09 1.34 32 P1 TEH TEC 12 80 OSI 05H 0.15 0.13 88 P1 TEH TEC 13 4
ONI 03H 0.05 1.84 34 P1 TEH TEC 13 4
ONI 07H
-0.05 1.37 37 P1 TEH TEC 13 22 ONI 06H 0.05 1.50 52 P1 TEH TEC 13 22 ONI 07H 0.03 1.75 39 P1 TEH TEC 13 27 ONI 02H 0.00 1.32 41 P1 TEH TEC 13 29 ONI 05H
-0.02 1.37 40 P1 TEH TEC 13 29 ONI 06H 0.00 1.62 35 P1 TEH TEC 13 32 OSI 02H
-0.05 0.10 116 P1 TEH TEC 13 33 PSI 03H
-0.53 15.67 157 8
TEH TEC 13 39 OSI 05H
-0.17 0.39 134 P1 TEH TEC 13 39 ONI 08H
-0.02 1.30 38 P1 TEH TEC 13 41 ONI 03H 0.02 1.36 20 P1 TEH TEC 13 41 ONI 07H 0.02 1.64 23 P1 TEH TEC 13 45 ONI 02H
-0.02 1.29 51 P1 TEH TEC 13 46 ONI 08C
-0.02 1.41 16 P1 TEH TEC 13 47 ONI 07C 0.00 1.32 43 P1 TEH TEC 13 47 ONI 04C 0.15 1.49 18 P1 TEH TEC 13 49 OSI 04H 0.05 0.17 83 P1 TEH TEC 13 55 SCI TSH 0.00 0.00 105 0.80 0.10 82 P2 TSH TSH 13 56 SCI TSH 0.01 0.18 137 1.05 0.11 101 P2 TSH TSH 13 57 ONI 07H
-0.02 1.56 41 P1 TEH TEC 13 58 SCI TSH
-0.09 0.15 77 0.59 0.15 84 P2 TSH TSH 13 60 OSI 02H 0.05 0.37 168 P1 TEH TEC 13 64 SCI TSH
-0.11 0.00 57 0.43 0.14 57 P2 TSH TSH Page 11 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 13 65 OSI 06C 0.05 0.13 104 P1 TEH TEC 13 66 ONI 05C
-0.12 1.28 17 P1 TEH TEC 13 67 ONI 08H 0.00 1.26 52 P1 TEH TEC 13 67 OSI 06C
-0.02 0.24 71 P1 TEH TEC 13 70 ONI 08H
-0.05 1.27 41 P1 TEH TEC 13 71 OSI 04H
-0.03 0.17 24 P1 TEH TEC 13 76 SCI TSH 0.00 0.22 134 1.02 0.25 85 P2 TSH TSH 13 80 OSI 03H 0.02 0.45 83 P1 TEH TEC 13 80 ONI 08H 0.02 1.25 54 P1 TEH TEC 13 80 ONI 07C
-0.05 1.76 34 P1 TEH TEC 13 80 ONI 06C 0.00 2.17 25 P1 TEH TEC 13 80 ONI 03C
-0.37 1.36 14 P1 TEH TEC 13 80 ONI 02C
-0.37 1.55 14 P1 TEH TEC 13 83 ONI 06H 0.00 1.91 47 P1 TEH TEC 13 83 ONI 07H 0.03 2.04 45 P1 TEH TEC 13 83 ONI 02C
-0.35 1.27 11 P1 TEH TEC 13 84 OSI 02H 0.00 0.39 66 P1 TEH TEC 13 85 OSI 02H 0.03 0.33 75 P1 TEH TEC 13 85 ONI 08C 0.00 1.44 41 P1 TEH TEC 13 85 ONI 07C
-0.02 1.82 34 P1 TEH TEC 13 85 ONI 05C
-0.08 1.60 31 P1 TEH TEC 13 85 ONI 03C
-0.05 1.41 19 P1 TEH TEC 13 86 OSI 03H 0.02 0.25 113 P1 TEH TEC 13 86 ONI 07H 0.02 1.71 49 P1 TEH TEC 13 86 ONI 08H 0.00 1.69 47 P1 TEH TEC 13 86 ONI 05C 0.00 1.86 29 P1 TEH TEC 13 87 ONI 08C
-0.02 1.89 34 P1 TEH TEC 13 87 ONI 07C
-0.02 2.08 30 P1 TEH TEC 13 87 ONI 06C 0.00 2.07 25 P1 TEH TEC 13 87 ONI 05C
-0.03 1.91 27 P1 TEH TEC 13 91 OSI 05H 0.00 0.79 126 P1 TEH TEC 13 92 OSI 04H 0.02 0.50 101 P1 TEH TEC 14 6
ONI 03H 0.17 2.44 10 P1 TEH TEC 14 15 ONI 03H 0.05 1.82 19 P1 TEH TEC 14 15 OSI 04H 0.00 0.26 132 P1 TEH TEC 14 19 ONI 06H 0.03 1.36 36 P1 TEH TEC 14 20 ONI 03H
-0.05 1.38 32 P1 TEH TEC 14 20 OSI 03H
-0.02 0.25 48 P1 TEH TEC 14 20 ONI 05H 0.37 1.54 16 P1 TEH TEC 14 20 ONI 06H 0.00 1.60 40 P1 TEH TEC 14 20 ONI 08C
-0.05 1.32 35 P1 TEH TEC 14 20 ONI 04C 0.00 2.10 11 P1 TEH TEC 14 21 ONI 06H 0.00 1.38 50 P1 TEH TEC 14 21 ONI 07H 0.00 1.61 33 P1 TEH TEC Page 12 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 14 24 ONI 05H
-0.03 1.31 52 P1 TEH TEC 14 24 ONI 06H 0.00 1.41 46 P1 TEH TEC 14 24 ONI 07H 0.02 1.38 39 P1 TEH TEC 14 25 OSI 05H 0.05 0.18 123 P1 TEH TEC 14 27 OSI 05H 0.05 0.45 158 P1 TEH TEC 14 31 OSI 02H 0.00 0.10 20 P1 TEH TEC 14 37 ONI 08H 0.17 1.32 15 P1 TEH TEC 14 37 ONI 07C
-0.02 1.'37 19 P1 TEH TEC 14 39 ONI 06H 0.02 1.39 47 P1 TEH TEC 14 40 OSI 05H
-0.02 0.20 30 P1 TEH TEC 14 40 SAi 05H
-0.07 0.22 32 0.25 0.12 95 6
05H 05H 14 41 ONI 05H 0.05 1.36 37 P1 TEH TEC 14 42 ONI 06H 0.05 1.32 44 P1 TEH TEC 14 43 ONI 06H 0.00 1.45 28 P1 TEH TEC 14 48 OSI 05H 0.00 0.39 140 P1 TEH TEC 14 49 ONI 06H 0.05 1.30 46 P1 TEH TEC 14 49 ONI 07H 0.02 1.43 49 P1 TEH TEC 14 49 ONI 08H 0.00 1.46 42 P1 TEH TEC 14 49 ONI 08C 0.05 1.38 34 P1 TEH TEC 14 49 ONI 07C 0.17 1.30 30 P1 TEH TEC 14 49 ONI 06C 0.10 1.28 40 P1 TEH TEC 14 49 ONI 05C
-0.05 1.50 35 P1 TEH TEC 14 50 OSI 03H 0.00 0.21 122 P1 TEH TEC 14 50 ONI 08H
-0.05 1.28 55 P1 TEH TEC 14 50 ONI 07C 0.00 1.15 43 P1 TEH TEC 14 50 ONI 03C
-0.37 1.67 11 P1 TEH TEC 14 53 OSI 02H
-0.08 0.11 71 P1 TEH TEC 14 54 OSI 02H 0.05 0.25 42 P1 TEH TEC 14 54 ONI 05H 0.00 1.65 53 P1 TEH TEC 14 54 ONI 06H 0.00 1.72 43 P1 TEH TEC 14 54 ONI 07H 0.02 1.40 48 P1 TEH TEC 14 54 ONI 08H
-0.02 1.27 46 P1 TEH TEC 14 55 ONI 05H 0.00 1.37 37 P1 TEH TEC 14 55 ONI 06H
-0.17 1.58 23 P1 TEH TEC 14 56 SCI TSH
-0.11 0.21 106 0.81 0.17 85 P2 TSH TSH 14 58 OSI 02H 0.07 0.31 161 P1 TEH TEC 14 58 ONI 08H 0.03 1.33 45 P1 TEH TEC 14 58 ONI 06C 0.00 1.55 33 P1 TEH TEC 14 58 ONI 02C
-0.15 1.59 15 P1 TEH TEC 14 59 OSI 02H 0.02 0.09 95 P1 TEH TEC 14 59 OSI 03H 0.05 0.20 59 P1 TEH TEC 14 59 OSI 06H 0.07 0.42 146 P1 TEH TEC 14 59 ONI 08H
-0.02 1.72 38 P1 TEH TEC 14 59 ONI 08C
-0.07 1.55 36 P1 TEH TEC Page 13 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 14 59 ONI 07C
-0.03 1.45 39 P1 TEH TEC 14 59 ONI 04C
-0.26 1.31 19 P1 TEH TEC 14 60 ONI 08H 0.00 1.41 51 P1 TEH TEC 14 61 ONI 06H 0.02 1.66 48 P1 TEH TEC 14 61 ONI 08H 0.03 1.46 43 P1 TEH TEC 14 61 ONI 07C 0.07 1.43 31 P1 TEH TEC 14 61 ONI 06C 0.00 1.31 32 P1 TEH TEC 14 64 ONI 04H 0.00 2.19 50 P1 TEH TEC 14 64 ONI 07C
-0.02 1.72 32 P1 TEH TEC 14 64 ONI 02C 0.27 1.92 13 P1 TEH TEC 14 65 ONI 02H 0.00 2.84 45 P1 TEH TEC 14 65 OSI 03H
-0.05 0.36 81 P1 TEH TEC 14 65 ONI 04C
-0.17 1.56 16 P1 TEH TEC 14 66 ONI 06H 0.00 1.31 50 P1 TEH TEC 14 66 ONI 08H
-0.02 1.49 43 P1 TEH TEC 14 67 ONI 07H 0.00 1.39 51 P1 TEH TEC 14 67 ONI 06C 0.17 1.37 25 P1 TEH TEC 14 68 OSI 02H 0.03 0.31 40 P1 TEH TEC 14 70 OSI 02H 0.05 0.34 55 P1 TEH TEC 14 70 OSI 03H 0.02 0.75 149 P1 TEH TEC 14 70 ONI 07H
-0.02 1.35 52 P1 TEH TEC 14 70 ONI 04C 0.32 1.45 11 P1 TEH TEC 14 72 OSI 06H 0.05 0.10 28 P1 TEH TEC 14 73 ONI 06H 0.17 1.77 32 P1 TEH TEC 14 73 ONI 07H 0.02 1.94 37 P1 TEH TEC 14 73 ONI 06C
-0.02 2.15 27 P1 TEH TEC 14 74 ONI 05H 0.02 1.38 50 P1 TEH TEC 14 77 ONI 05H 0.02 1.32 55 P1 TEH TEC 14 77 ONI 08H 0.00 1.46 44 P1 TEH TEC 14 77 ONI 07C
-0.02 1.59 35 P1 TEH TEC 14 80 OSI 03H 0.00 0.20 128 P1 TEH TEC 14 86 OSI 04H 0.05 0.28 37 P1 TEH TEC 15 22 SCI TSH
-0.19 0.14 17 0.13 0.12 112 P2 TSH TSH 15 26 ONI 07C
-0.03 1.36 23 P1 TEH TEC 15 27 OSI 05H
-0.02 0.17 119 P1 TEH TEC 15 28 ONI 02H 0.12 1.31 16 P1 TEH TEC 15 31 OSI 04H 0.00 0.30 36 P1 STH TEC 15 31 SAi 04H 0.00 0.29 32 0.25 0.18 72 2
04H 05H 15 35 ONI 06H
-0.02 1.59 38 P1 TEH TEC 15 38 ONI 07H 0.02 1.35 41 P1 TEH TEC 15 40 ONI 06H 0.05 1.26 50 P1 TEH TEC 15 40 ONI 07H 0.00 1.32 44 P1 TEH TEC 15 40 ONI 08H 0.02 1.64 35 P1 TEH TEC 15 47 ONI 05H 0.17 1.38 15 P1 TEH TEC Page 14 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 15 50 ONI 07H 0.00 1.26 47 P1 TEH TEC 15 50 ONI 08H
-0.10 1.29 45 P1 TEH TEC 15 51 SCI TSH 0.00 0.31 71 0.54 0.46 113 P2 TSH TSH 15 54 ONI 04H 0.00 1.37 44 P1 TEH TEC 15 60 ONI 04H
-0.02 1.28 52 P1 TEH TEC 15 62 SCI TSH 0.00 3.23 102 0.78 0.12 83 P2 TSH TSH 15 63 OSI 02H 0.00 0.12 82 P1 TEH TEC 15 63 ONI 06H 0.02 1.73 32 P1 TEH TEC 15 65 ONI 03H 0.00 1.45 51 P1 TEH TEC 15 67 OSI 02H 0.00 0.27 32 P1 TEH TEC 15 70 ONI 03H 0.00 1.34 51 P1 TEH TEC 15 71 OSI 02H 0.07 0.11 83 P1 TEH TEC 15 72 OSI 02H 0.00 0.15 63 P1 TEH TEC 15 73 OSI 03H
-0.02 0.57 112 P1 TEH TEC 15 73 OSI 05H 0.02 0.17 100 P1 TEH TEC 15 74 OSI 03H
-0.15 1.04 41 P1 TEH TEC 15 74 ONI 05H 0.00 1.56 55 P1 TEH TEC 15 74 ONI 07H 0.05 1.74 49 P1 TEH TEC 15 74 ONI 08H 0.00 1.77 46 P1 TEH TEC 15 75 SAi 08H
-0.03 0.29 25 0.19 0.08 131 6
08H 08H 15 75 OSI 02H 0.02 0.63 144 P1 TEH TEC 15 75 OSI 08H 0.05 0.39 167 P1 TEH TEC 15 75 ONI 07C 0.00 1.71 37 P1 TEH TEC 15 75 ONI 02C 0.10 1.38 13 P1 TEH TEC 15 76 ONI 08H
-0.02 1.26 51 P1 TEH TEC 15 78 ONI DSC
-0.15 1.57 22 P1 TEH TEC 15 80 ONI 02H
-0.02 2.05 50 P1 TEH TEC 15 80 ONI 04H 0.02 2.13 48 P1 TEH TEC 15 80 ONI 05H 0.02 1.88 51 P1 TEH TEC 15 80 ONI 07H 0.02 1.76 46 P1 TEH TEC 15 80 ONI 08H 0.00 1.83 42 P1 TEH TEC 15 80 ONI 07C 0.02 1.61 35 P1 TEH TEC 15 82 ONI 03H 0.02 1.51 50 P1 TEH TEC 15 82 ONI 07H
-0.03 1.48 51 P1 TEH TEC 15 82 ONI 08H 0.03 1.20 58 P1 TEH TEC 15 86 NQI 05H 20.11 0.18 98 3
TEH TEC 15 91 ONI DSC 0.03 1.59 9
P1 TEH TEC 16 11 OSI 05H
-0.07 0.23 131 P1 TEH TEC 16 11 SAi 05H
-0.14 0.19 31 0.23 0.10 89 P4 05H 06H 16 18 ONI 04H 0.22 1.43 17 P1 TEH TEC 16 38 ONI 07C
-0.12 1.75 10 P1 TEH TEC 16 39 ONI 04H
-0.07 1.77 10 P1 TEH TEC 16 40 ONI 03H
-0.02 1.42 45 P1 TEH TEC 16 40 ONI 05H 0.05 1.48 41 P1 TEH TEC Page 15 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 16 40 ONI 06H 0.00 1.45 47 P1 TEH TEC 16 40 ONI 07H 0.02 1.30 47 P1 TEH TEC 16 44 ONI 05H 0.05 1.37 48 P1 TEH TEC 16 48 SCI TSH 0.00 0.33 78 0.60 0.20 64 P2 TSH TSH 16 50 OSI 05C 0.05 0.22 158 P1 TEH TEC 16 52 OSI 02H 0.05 0.55 151 P1 TEH TEC 16 52 ONI 07H 0.00 1.44 53 P1 TEH TEC 16 52 ONI 04C 0.02 1.47 17 P1 TEH TEC 16 52 ONI 02C 0.22 1.63 13 P1 TEH TEC 16 53 OSI 03H
-0.02 0.17 44 P1 TEH TEC 16 54 ONI 08H 0.02 1.37 50 P1 TEH TEC 16 54 ONI 07C 0.00 2.11 28 P1 TEH TEC 16 55 ONI 03H 0.00 1.48 53 P1 TEH TEC 16 55 ONI 07H 0.00 1.26 55 P1 TEH TEC 16 56 ONI 07H 0.05 1.61 41 P1 TEH TEC 16 57 ONI 06H
-0.03 1.60 47 P1 TEH TEC 16 57 ONI 08H 0.00 1.94 37 P1 TEH TEC 16 57 ONI 08C
-0.05 1.49 40 P1 TEH TEC 16 57 ONI 07C
-0.05 1.31 39 P1 TEH TEC 16 59 ONI 02H 0.00 1.51 55 P1 TEH TEC 16 59 ONI 03H
-0.05 2.15 47 P1 TEH TEC 16 59 ONI 04H
-0.17 0.96 53 P1 TEH TEC 16 59 ONI 07H 0.05 1.88 37 P1 TEH TEC 16 59 ONI 08C'
-0.37 1.50 16 P1 TEH TEC 16 59 ONI 07C
-0.17 1.26 26 P1 TEH TEC 16 59 ONI 06C
-0.02 1.72 30 P1 TEH TEC 16 60 OSI 02H
-0.05 0.13 144 P1 TEH TEC 16 62 OSI 08H
-0.02 0.06 103 P1 TEH TEC 16 66 OSI 03H
-0.02 0.16 63 P1 TEH TEC 16 66 ONI 07C 0.00 1.41 33 P1 TEH TEC 16 70 OSI 03H 0.00 0.31 89 P1 TEH TEC 16 72 OSI 02H 0.00 0.11 127 P1 TEH TEC 16 72 ONI 05H 0.02 1.73 46 P1 TEH TEC 16 76 OSI 02H 0.02 0.32 113 P1 TEH TEC 16 77 OSI 05H
-0.05 0.20 150 P1 TEH TEC 16 84 ONI 07H 0.00 1.52 49 P1 TEH TEC 16 86 ONI 02C 0.15 1.56 14 P1 STH TEC 17 6
ONI 02H 0.15 1.37 18 P1 TEH TEC 17 10 OSI 03H
-0.09 0.33 165 P1 TEH TEC 17 12 ONI 04H 0.18 1.84 15 P1 TEH TEC 17 23 ONI 07C
-0.12 1.15 17 P1 STH TEC 17 27 OSI 04H 0.05 0.12 84 P1 TEH TEC 17 31 ONI 04H
-0.10 1.31 16 P1 TEH TEC 17 32 OSI 05H 0.05 0.25 32 P1 TEH TEC Page 16 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 17 33 SCI TSH
-0.17 0.18 145 1.10 0.62 38 P2 TSH TSH 17 35 ONI 06H 0.02 1.45 29 P1 TEH TEC 17 39 ONI 05H 0.20 1.79 17 P1 TEH TEC 17 46 OSI 02H 0.02 0.54 20 P1 TEH TEC 17 46 ONI 04H 0.00 1.27 23 P1 TEH TEC 17 46 SAi TSH 0.00 0.12 35 0.27 0.15 53 6
TSH TSH 17 49 ONI 06C 0.05 1.52 28 P1 TEH TEC 17 49 ONI 05C
-0.05 1.77 28 P1 TEH TEC 17 49 ONI 04C
-0.02 1.49 15 P1 TEH TEC 17 51 ONI 05H 0.00 1.37 50 P1 TEH TEC 17 51 ONI 07H 0.02 1.28 52 P1 TEH TEC 17 51 ONI 08H
-0.07 1.84 40 P1 TEH TEC 17 53 ONI 08C 0.05 1.61 37 P1 TEH TEC 17 54 ONI 08H
-0.02 1.77 41 P1 TEH TEC 17 54 ONI 08C
-0.25 1.67 16 P1 TEH TEC 17 54 ONI 07C 0.03 2.01 29 P1 TEH TEC 17 54 ONI 06C 0.02 1.62 31 P1 TEH TEC 17 54 ONI 03C
-0.32 1.48 14 P1 TEH TEC 17 59 OSI 02H 0.05 0.26 145 P1 TEH TEC 17 59 OSI 05H 0.05 0.22 121 P1 TEH TEC 17 66 ONI 03H 0.00 1.54 55 P1 TEH TEC 17 72 ONI 02H
-0.07 1.13 21 P1 TEH TEC 17 73 SCI TSH 0.00 0.33 160 1.22 0.28 18 P2 TSH TSH 17 76 ONI 02H 0.00 1.97 55 P1 TEH TEC 17 76 ONI 03H 0.00 1.92 41 P1 TEH TEC 17 76 ONI 07H 0.00 1.77 48 P1 TEH TEC 17 76 ONI 05C 0.26 1.70 15 P1 TEH TEC 17 81 OSI 03H 0.00 0.10 142 P1 TEH TEC 17 81 OSI 04H
-0.05 0.17 63 P1 TEH TEC 17 83 ONI AV2 5.59 0.17 108 5
TEH TEC 17 84 OSI 03H 0.02 0.11 95 P1 TEH TEC 17 85 ONI 05H 0.00 1.36 53 P1 TEH TEC 18 7
OSI 04H 0.02 0.25 147 P1 TEH TEC 18 7
ONI 07H 0.03 1.26 50 P1 TEH TEC 18 7
ONI 08H 0.00 1.45 45 P1 TEH TEC 18 10 OSI 03H 0.00 0.60 170 P1 TEH TEC 18 10 OSI 04H 0.00 0.21 138 P1 TEH TEC 18 15 ONI 08H
-0.15 1.85 17 P1 TEH TEC 18 17 ONI 04H
-0.15 1.49 21 P1 TEH TEC 18 27 SAi TSH 0.16 0.14 38 0.29 0.13 56 6
TSH TSH 18 27 OSI 07H
-0.03 0.13 35 P1 TEH TEC 18 30 OSI 04H 0.00 0.08 35 P1 TEH TEC 18 32 ONI 07H
-0.02 1.36 48 P1 TEH TEC 18 32 ONI 08H 0.00 1.30 49 P1 TEH TEC Page 17 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 18 43 ONI 05H 0.05 1.44 49 P1 TEH TEC 18 43 ONI 06H 0.02 1.35 52 P1 TEH TEC 18 43 ONI 07H 0.02 1.68 36 P1 TEH TEC 18 45 ONI 07H 0.00 1.26 51 P1 TEH TEC 18 47 OSI 02H 0.00 0.24 130 P1 TEH TEC 18 47 OSI 05H
-0.05 0.38 94 P1 TEH TEC 18 48 ONI 07H 0.05 1.82 41 P1 TEH TEC 18 48 ONI 08H 0.02 1.99 37 P1 TEH TEC 18 52 ONI 06C 0.00 2.14 26 P1 TEH TEC 18 52 ONI 05C
-0.05 2.14 21 P1 TEH TEC 18 52 ONI 04C 0.02 1.30 17 P1 TEH TEC 18 55 ONI 04H 0.02 1.78 48 P1 TEH TEC 18 55 ONI 05H 0.00 2.33 41 P1 TEH TEC 18 55 ONI 06H 0.00 1.73 43 P1 TEH TEC 18 55 ONI 07H 0.00 1.33 51 P1 TEH TEC 18 55 ONI 08C
-0.03 1.48 35 P1 TEH TEC 18 55 ONI 07C 0.00 1.51 32 P1 TEH TEC 18 55 ONI 06C 0.02 1.56 29 P1 TEH TEC 18 56 ONI 04H 0.02 1.44 53 P1 TEH TEC 18 56 ONI 05H 0.00 1.67 52 P1 TEH TEC 18 56 ONI 07H 0.00 1.63 43 P1 TEH TEC 18 56 ONI 08H 0.03 1.37 44 P1 TEH TEC 18 57 OSI 02H 0.02 0.45 71 P1 TEH TEC 18 57 ONI 04H 0.07 1.54 49 P1 TEH TEC 18 57 ONI 05H 0.02 1.72 52 P1 TEH TEC 18 57 ONI 06H 0.03 1.68 51 P1 TEH TEC 18 57 ONI 07H
-0.02 1.80 44 P1 TEH TEC 18 57 ONI 08H 0.02 1.53 43 P1 TEH TEC 18 57 ONI 05C 0.02 1.58 29 P1 TEH TEC 18 58 OSI 02H 0.05 0.56 84 P1 TEH TEC 18 83 ONI 05H
-0.02 1.26 53 P1 TEH TEC 18 88 OSI 05H 0.02 0.11 94 P1 TEH TEC 19 7
OSI 02H
-0.02 0.35 112 P1 TEH TEC 19 7
OSI 03H
-0.02 0.31 91 P1 TEH TEC 19 7
SAi 03H 0.00 0.13 22 0.16 0.14 86 6
02H 03H 19 8
OSI 03H
-0.07 0.22 119 P1 TEH TEC 19 8
ONI 04H 0.00 1.36 52 P1 TEH TEC 19 13 ONI 04H 0.10 1.48 16 P1 TEH TEC 19 15 OSI 03H
-0.03 0.21 136 P1 TEH TEC 19 15 OSI 04H
-0.02 0.19 117 P1 TEH TEC 19 45 SCI TSH
-0.03 0.10 60 0.46 0.16 78 P2 TSH TSH 19 49 ONI 08C
-0.07 1.31 19 P1 TEH TEC 19 54 ONI 04H 0.25 1.26 14 P1 TEH TEC 19 56 OSI 03H
-0.20 0.47 72 P1 TEH TEC Page 18 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 19 56 ONI 06H 0.03 1.51 47 P1 TEH TEC 19 56 ONI 07H 0.00 1.36 49 P1 TEH TEC 19 56 ONI 08H 0.00 1.29 41 P1 TEH TEC 19 57 OSI 02H 0.07 0.44 165 P1 TEH TEC 19 57 OSI 04H 0.02 0.18 136 P1 TEH TEC 19 57 ONI 08H
-0.03 1.54 44 P1 TEH TEC 19 59 ONI 02H 0.03 2.30 53 P1 TEH TEC 19 59 ONI 03H 0.03 2.34 37 P1 TEH TEC 19 59 ONI 04H
-0.03 2.93 37 P1 TEH TEC 19 59 ONI 05H
-0.32 2.27 15 P1 TEH TEC 19 59 ONI 08H 0.34 1.37 15 P1 TEH TEC 19 59 ONI 06C
-0.14 1.44 24 P1 TEH TEC 19 59 ONI 05C 0.34 2.31 16 P1 TEH TEC 19 60 OSI 02H 0.03 0.15 58 P1 TEH TEC 19 60 ONI 03H
-0.05 1.53 53 P1 TEH TEC 19 60 ONI 07H 0.00 1.29 48 P1 TEH TEC 20 7
OSI 08C
-0.05 0.09 60 P1 TEH TEC 20 9
OSI 03H 0.00 0.18 137 P1 TEH TEC 20 9
ONI 06H 0.00 1.30 49 P1 TEH TEC 20 9
ONI 07H 0.00 1.30 41 P1 TEH TEC 20 10 ONI 03H 0.00 1.30 50 P1 TEH TEC 20 10 OSI 04H 0.00 0.20 78 P1 TEH TEC 20 12 OSI 02H 0.00 0.10 103 P1 TEH TEC 20 15 ONI 07H 0.02 1.49 36 P1 TEH TEC 20 20 ONI 05H 0.00 1.26 53 P1 TEH TEC 20 22 OSI 02H 0.09 0.30 115 P1 TEH TEC 20 22 OSI 03H 0.02 0.18 75 P1 TEH TEC 20 22 OSI 08H 0.00 0.22 46 P1 TEH TEC 20 22 ONI 08C 0.05 1.24 30 P1 TEH TEC 20 24 ONI 06H 0.07 1.53 17 P1 TEH TEC 20 25 ONI 07H 0.00 1.30 41 P1 TEH TEC 20 36 ONI 06H 0.02 1.50 51 P1 TEH TEC 20 40 ONI 07H 0.02 1.30 23 P1 TEH TEC 20 43 ONI 06H 0.05 1.34 52 P1 TEH TEC 20 46 ONI 02C 0.02 1.48 16 P1 TEH TEC 20 57 OSI 02H 0.03 0.13 121 P1 STH TEC 20 57 ONI 07C 0.00 1.27 34 P1 STH TEC 20 57 ONI 06C
-0.05 1.89 14 P1 STH TEC 20 58 ONI 08C
-0.07 1.67 18 P1 TEH TEC 20 60 ONI 08H 0.00 1.25 42 P1 TEH TEC 20 61 ONI 06H 0.02 1.41 51 P1 TEH TEC 20 61 ONI 08H 0.00 1.59 38 P1 TEH TEC 20 62 OSI 05H
-0.07 0.40 135 P1 TEH TEC 20 64 PCT AV1 0.00 19 1.52 0
P2 TEH TEC Page 19 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 20 64 PCT AV2 0.00 23 2.08 0
P2 TEH TEC 20 64 PCT AV3 0.00 22 1.94 0
P2 TEH TEC 20 68 DNI 06C 0.10 1.34 13 P1 TEH TEC 20 72 DSI 07C
-0.07 0.22 37 P1 TEH TEC 20 72 DNI 07C 0.09 1.64 14 P1 TEH TEC 20 75 DSI 05H
-0.02 0.35 167 P1 TEH TEC 20 78 DSI 04H 0.05 0.14 141 P1 TEH TEC 20 78 DNI 08H 0.00 1.38 41 P1 TEH TEC 20 81 DNI 05C 0.16 1.91 17 P1 TEH TEC 20 85 DSI 03H 0.00 0.29 160 P1 TEH TEC 21 10 DNI 06H
-0.02 1.25 53 P1 TEH TEC 21 12 DNI 07H 0.00 1.80 29 P1 TEH TEC 21 13 DNI 05H
-0.02 1.28 36 P1 TEH TEC 21 18 DSI 04H 0.00 0.41 170 P1 TEH TEC 21 21 DNI 05H 0.07 1.54 23 P1 TEH TEC 21 21 DNI 07H 0.18 1.68 16 P1 TEH TEC 21 25 DSI 03H 0.05 0.19 74 P1 TEH TEC 21 26 DSI 05H 0.02 0.35 86 P1 TEH TEC 21 34 DSI 02H 0.02 0.41 158 P1 TEH TEC 21 40 DNI 07H 0.00 1.58 42 P1 TEH TEC 21 42 DNI 06H 0.00 1.32 53 P1 TEH TEC 21 42 DNI 07H 0.00 1.32 48 P1 TEH TEC 21 43 DSI 02H 0.00 0.28 154 P1 TEH TEC 21 43 DNI 05H 0.00 1.28 52 P1 TEH TEC 21 45 DNI 06H 0.00 1.27 56 P1 TEH TEC 21 45 DNI 07H 0.00 1.43 42 P1 TEH TEC 21 46 DSI 02H 0.00 0.17 53 P1 TEH TEC 21 48 DNI 02H 0.11 1.28 39 P1 TEH TEC 21 48 DNI 03H
-0.12 1.30 25 P1 TEH TEC 21 48 DNI 05H
-0.05 1.92 26 P1 TEH TEC 21 48 DNI 06H 0.00 1.34 42 P1 TEH TEC 21 48 DNI 08H 0.19 1.45 14 P1 TEH TEC 21 48 DNI 08C 0.00 1.42 22 P1 TEH TEC 21 51 DNI 03H
-0.16 1.35 7
P1 TEH TEC 21 51 DNI 06H 0.17 1.38 9
P1 TEH TEC 21 51 DNI 05C
-0.12 1.41 18 P1 TEH TEC 21 55 DSI 02H 0.00 0.05 104 P1 TEH TEC 21 60 DNI 05H 0.00 1.29 38 P1 TEH TEC 21 60 DNI 08H
-0.08 1.37 35 P1 TEH TEC 21 61 DSI 08H 0.05 0.14 121 P1 TEH TEC 21 72 DSI 03H
-0.03 0.30 58 P1 TEH TEC 21 73 DSI 03H
-0.18 0.90 50 P1 TEH TEC 21 73 DNI 07H
-0.22 1.64 9
P1 TEH TEC 21 73 DNI 02C
-0.02 1.43 16 P1 TEH TEC Page 20 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 21 75 ONI 08C 0.03 1.36 32 P1 TEH TEC 21 75 ONI 05C 0.05 1.38 1
P1 TEH TEC 21 77 ONI 03H 0.05 1.25 18 P1 TEH TEC 21 77 ONI 05H 0.20 1.22 11 P1 TEH TEC 21 78 OSI 08H 0.02 0.14 147 P1 TEH TEC 21 85 ONI AV3
-1.30 0.49 154 5
TEH TEC 21 87 OSI 08C 0.02 0.11 69 P1 TEH TEC 22 7
OSI 02H 0.08 0.20 130 P1 TEH TEC 22 10 ONI 08C
-0.20 1.29 13 P1 TEH TEC 22 10 ONI 07C
-0.12 1.30 17 P1 TEH TEC 22 12 ONI 03H 0.00 1.45 49 P1 TEH TEC 22 15 ONI 06H 0.00 1.30 50 P1 TEH TEC 22 18 ONI 08C
-0.05 1.73 22 P1 TEH TEC 22 21 OSI 02H
-0.02 0.12 139 P1 TEH TEC 22 21 OSI 03H 0.00 0.39 151 P1 TEH TEC 22 23 OSI 02H
-0.09 0.25 163 P1 TEH TEC 22 23 ONI 08H 0.02 1.67 13 P1 TEH TEC 22 24 OSI 02H 0.07 0.27 132 P1 TEH TEC 22 25 OSI 02H 0.05 0.17 89 P1 TEH TEC 22 33 ONI 08H
-0.02 1.27 42 P1 TEH TEC 22 36 ONI 06H 0.02 1.36 52 P1 TEH TEC 22 46 SCI TSH 0.00 0.40 118 0.90 0.11 87 P2 TSH TSH 22 51 ONI 07H 0.00 1.36 53 P1 TEH TEC 22 51 ONI 08C 0.05 2.12 27 P1 TEH TEC 22 53 ONI 03H
-0.02 1.45 17 P1 TEH TEC 22 53 ONI 04H 0.00 1.80 19 P1 TEH TEC 22 53 ONI 06H 0.05 1.26 32 P1 TEH TEC 22 53 ONI 08H
-0.07 1.30 14 P1 TEH TEC 22 59 ONI 05H 0.00 1.27 40 P1 TEH TEC 22 59 ONI 05C 0.08 1.32 14 P1 TEH TEC 22 65 ONI 07H 0.10 1.28 23 P1 TEH TEC 22 65 ONI 05C
-0.07 1.89 18 P1 TEH TEC 22 66 ONI 03H
-0.05 1.64 29 P1 TEH TEC 22 66 ONI 06H 0.00 1.44 28 P1 TEH TEC 22 72 ONI 04H 0.00 1.25 53 P1 TEH TEC 22 74 ONI 04H
-0.15 2.01 13 P1 TEH TEC 22 74 ONI 08H
-0.26 2.25 12 P1 TEH TEC 22 76 ONI 05H 0.18 1.60 17 P1 TEH TEC 22 76 ONI 06H 0.07 1.32 27 P1 TEH TEC 23 10 ONI 07H 0.00 1.51 23 P1 TEH TEC 23 11 OSI 02H
-0.07 0.39 23 P1 TEH TEC 23 11 OSI 03H
-0.05 0.15 92 P1 TEH TEC 23 11 ONI 08H
-0.05 1.26 36 P1 TEH TEC 23 18 SCI TSH
-0.11 0.22 138 1.06 0.21 92 P2 TSH TSH Page 21 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW {Inches) {Degrees) {Inches) VOLTS {Degrees) CHAN FROM TO 23 19 OSI 02H
-0.07 0.67 39 P1 TEH TEC 23 19 ONI 03H
-0.02 1.59 38 P1 TEH TEC 23 19 ONI 04H
-0.05 1.58 44 P1 TEH TEC 23 20 OSI 02H
-0.05 0.22 138 P1 TEH TEC 23 21 OSI 03H 0.00 0.20 128 P1 TEH TEC 23 21 ONI 07H 0.18 1.26 19 P1 TEH TEC 23 22 SCI TSH
-0.21 0.25 29 0.22 0.14 105 P2 TSH TSH 23 22 SAi TSH
-0.10 0.14 51 0.39 0.10 115 6
TSH TSH 23 22 ONI 05H 0.20 1.40 20 P1 TEH TEC 23 26 ONI 07H 0.00 1.28 55 P1 TEH TEC 23 27 SCI TSH
-0.06 0.16 66 0.51 0.22 79 P2 TSH TSH 23 33 ONI 07H 0.00 1.39 44 P1 TEH TEC 23 40 ONI 05H 0.00 1.29 55 P1 TEH TEC 23 46 ONI 03H
-0.18 1.37 24 P1 TEH TEC 23 46 ONI 06H 0.00 1.89 35 P1 TEH TEC 23 46 ONI 07H
-0.25 1.58 10 P1 TEH TEC 23 46 ONI 08C 0.14 1.30 11 P1 TEH TEC 23 49 ONI 06C 0.30 2.26 9
P1 TEH TEC 23 52 OSI 03H 0.02 0.29 40 P1 TEH TEC 23 53 SAi 02H
-0.10 0.20 43 0.33 0.11 101 6
02H 02H 23 53 OSI 02H 0.05 0.20 17 P1 TEH TEC 23 80 ONI 07H
. -0.14 1.53 21 P1 TEH TEC 23 81 ONI 04H 0.00 1.49 54 P1 TEH TEC 23 87 OSI 04H 0.00 0.33 132 P1 TEH TEC 24 16 OSI 02H 0.05 0.39 170 P1 TEH TEC 24 16 OSI 03H 0.02 0.15 134 P1 TEH TEC 24 17 ONI 05H 0.05 1.54 51 P1 TEH TEC 24 17 ONI 08C 0.00 1.38 32 P1 TEH TEC 24 23 OSI 05H
-0.09 0.83 23 P1 TEH TEC 24 24 OSI 02H
-0.04 0.11 102 P1 TEH TEC 24 24 ONI 05H
-0.17 1.41 29 P1 TEH TEC 24 27 SAi TSH 0.00 0.13 42 0.32 0.16 44 6
TSH TSH 24 29 ONI 07H
-0.03 1.47 28 P1 TEH TEC 24 29 ONI 08H 0.00 1.44 29 P1 TEH TEC 24 33 OSI 03H
-0.02 0.21 58 P1 TEH TEC 24 39 OSI 02H
-0.03 0.22 73 P1 TEH TEC 24 40 ONI 05H 0.02 1.40 49 P1 TEH TEC 24 40 ONI 06H 0.02 1.30 47 P1 TEH TEC 24 43 ONI 06H 0.00 1.25 41 P1 TEH TEC 24 52 OSI 02H 0.02 0.20 124 P1 TEH TEC 24 52 ONI 05H 0.00 1.38 52 P1 TEH TEC 24 52 ONI 06H 0.00 1.25 53 P1 TEH TEC 24 59 ONI 04H
-0.13 1.42 16 P1 TEH TEC 24 63 OSI 05H 0.07 0.42 161 P1 TEH TEC Page 22 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21 A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 24 69 ONI 04C
-0.20 1.28 10 P1 TEH TEC 24 70 SCI TSH
-0.13 0.00 182 1.39 0.08 84 P2 TSH TSH 24 80 OSI 03H
-0.02 0.19 135 P1 TEH TEC 24 80 ONI 05H 0.02 1.38 52 P1 TEH TEC 25 21 OSI 02H 0.03 0.06 101 P1 TEH TEC 25 22 OSI 02H
-0.07 0.42 30 P1 TEH TEC 25 30 OSI 04H 0.03 0.32 64 P1 TEH TEC 25 30 OSI 06H 0.02 0.10 90 P1 TEH TEC 25 39 ONI 07C 0.11 1.36 11 P1 TEH TEC 25 46 SCI TSH
-0.14 0.21 295 2.26 0.14 87 P2 TSH TSH 25 50 OSI 08H 0.02 0.14 104 P1 TEH TEC 25 53 ONI 06H 0.02 1.44 19 P1 TEH TEC 25 77 ONI AV2 9.16 0.46 154 5
TEH TEC 26 15 OSI 03H 0.05 0.17 135 P1 TEH TEC 26 17 ONI 08H
-0.02 1.42 42 P1 TEH TEC 26 19 OSI 04H 0.02 0.14 68 P1 TEH TEC 26 24 ONI 05H 0.00 1.25 47 P1 TEH TEC 26 25 ONI 07H 0.00 1.27 49 P1 TEH TEC 26 28 ONI 08H
-0.03 1.41 38 P1 TEH TEC 26 28 SCI TSH
-0.07 0.25 134 1.02 0.19 77 P2 TSH TSH 26 36 ONI 03H 0.00 1.51 44 P1 TEH TEC 26 36 ONI 04H 0.05 1.52 40 P1 TEH TEC 26 36 ONI 06H 0.03 1.42 44 P1 TEH TEC 26 36 ONI 05C 0.00 1.57 15 P1 TEH TEC 26 37 NQI 06H 17.18 0.33 99 3
STH TEC 26 39 ONI 04H 0.00 1.29 54 P1 TEH TEC 26 40 ONI 06H 0.02 1.26 34 P1 TEH TEC 26 42 OSI 02H
-0.02 0.33 124 P1 TEH TEC 26 43 ONI 05H 0.00 1.46 37 P1 TEH TEC 26 43 ONI 06H 0.00 1.30 35 P1 TEH TEC 26 45 ONI 05H 0.00 1.49 44 P1 TEH TEC 26 45 ONI 06H 0.00 1.37 50 P1 TEH TEC 26 49 ONI 05H 0.00 1.25 53 P1 TEH TEC 26 60 ONI 06H 0.00 1.29 31 P1 TEH TEC 26 67 ONI 04H
-0.16 1.48 21 P1 TEH TEC 26 80 OSI 05H
-0.05 0.11 79 P1 TEH TEC 27 32 OSI 02H
-0.03 0.21 58 P1 TEH TEC 27 33 OSI 03H
-0.18 0.43 57 P1 TEH TEC 27 34 OSI 04H
-0.05 0.21 90 P1 TEH TEC 27 42 OSI 04H 0.00 0.20 134 P1 TEH TEC 27 42 OSI 05H 0.18 0.27 61 P1 TEH TEC 27 42 SAi 04H 0.03 0.18 49 0.38 0.10 94 6
04H 04H 27 47 OSI 02H
-0.02 0.28 111 P1 TEH TEC 27 47 ONI 06H 0.02 1.53 45 P1 TEH TEC Page 23 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 27 47 ONI 07H 0.02 1.32 43 P1 TEH TEC 27 58 ONI 07C
-0.22 2.14 9
P1 TEH TEC 27 64 OSI 02H
-0.02 0.22 49 P1 TEH TEC 27 64 ONI 07H 0.00 1.35 36 P1 TEH TEC 27 71 PCT AV2 0.26 16 1.09 0
P2 TEH TEC 27 71 PCT AV3 0.00 16 1.10 0
P2 TEH TEC 27 71 PCT AV4
-0.29 14 0.91 0
P2 TEH TEC 27 75 OSI 05H 0.00 0.28 148 P1 TEH TEC 27 75 PCT AV3 0.00 11 0.65 0
P2 TEH TEC 27 79 ONI AV2 15.34 0.52 155 5
TEH TEC 28 13 OSI 03H 0.02 0.33 159 P1 TEH TEC 28 16 ONI 03H
-0.02 1.41 36 P1 TEH TEC 28 17 ONI 04H 0.02 1.26 51 P1 TEH TEC 28 17 ONI 05H 0.02 1.37 47 P1 TEH TEC 28 21 SAi TSH 0.07 0.18 52 0.40 0.11 91 6
TSH TSH 28 26 OSI 04H 0.00 0.26 81 P1 TEH TEC 28 27 PSI 05H
-0.54 15.42 157 8
TEH TEC 28 27 ONI 07H 0.00 1.25 26 P1 TEH TEC 28 27 SCI TSH
-0.10 0.18 38 0.29 0.16 76 P2 TSH TSH 28 30 ONI 08H 0.00 1.43 11 P1 TEH TEC 28 41 OSI 02H 0.00 0.20 90 P1 TEH TEC 28 41 ONI 05H 0.00 1.39 50 P1 TEH TEC 28 41 ONI 06H 0.02 1.32 47 P1 TEH TEC 28 41 ONI 07H 0.02 1.38 43 P1 TEH TEC 28 42 ONI 03H
-0.02 1.33 70 P1 TEH TEC 28 44 ONI 05H
-0.03 1.36 55 P1 TEH TEC 28 45 OSI 02H 0.02 0.26 77 P1 TEH TEC 28 46 OSI 03H
-0.02 0.10 65 P1 STH TEC 28 54 OSI 02H
-0.05 0.17 111 P1 TEH TEC 28 56 OSI 03H 0.12 0.60 157 P1 TEH TEC 28 56 ONI 06H 0.02 1.43 52 P1 TEH TEC 28 59 ONI 04H
-0.27 1.25 64 P1 STH TEC 28 64 SCI TSH 0.04 0.24 35 0.27 0.12 89 P2 TSH TSH 28 66 SAi 04H
-0.20 0.21 29 0.22 0.13 114 6
04H 04H 28 66 OSI 04H 0.00 0.15 146 P1 TEH TEC 28 67 SCI TSH
-0.02 0.17 100 0.81 0.62 20 P2 TSH TSH 28 70 SAi TSH 0.00 0.16 58 0.45 0.15 77 6
TSH TSH 28 75 ONI 07H 0.03 1.25 33 P1 TEH TEC 28 75 ONI 08H
-0.02 1.27 26 P1 TEH TEC 28 77 SCI TSH 0.02 0.28 162 1.23 0.28 35 P2 TSH TSH 29 13 ONI 08H
-0.02 1.29 37 P1 TEH TEC 29 16 ONI 06H 0.03 1.58 44 P1 TEH TEC 29 16 ONI 07H
-0.02 1.39 44 P1 TEH TEC 29 18 ONI 05H 0.00 1.41 53 P1 TEH TEC Page 24 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 29 19 DNI 08H 0.00 1.54 22 P1 TEH TEC 29 24 DSI 02H
-0.02 0.19 68 P1 TEH TEC 29 24 DSI 04H 0.12 0.14 25 P1 TEH TEC 29 24 DNI 07H 0.00 1.23 58 P1 TEH TEC 29 24 DNI 08H
-0.05 1.43 40 P1 TEH TEC 29 29 DNI 03H 0.09 1.98 18 P1 TEH TEC 29 30 DSI 05H 0.00 0.32 17 P1 TEH TEC 29 54 SAi 03H
-0.05 0.29 37 0.28 0.11 99 6
03H 03H 29 54 SAi 03H 0.06 0.39 58 0.45 0.12 89 6
03H 03H 29 54 DSI 03H 0.00 0.21 97 P1 TEH TEC 29 56 DNI 06H 0.32 1.37 13 P1 STH TEC 29 62 DNI 02H
-0.05 1.42 52 P1 TEH TEC 29 65 DSI 02H
-0.05 0.10 16 P1 TEH TEC 29 69 SCI TSH
-0.03 0.17 118 0.90 0.16 108 P2 TSH TSH 29 72 PCT AV1 0.39 15 1.03 0
P2 TEH TEC 29 76 DNI 08H 0.10 1.43 11 P1 TEH TEC 30 20 DNI 08H 0.17 1.34 22 P1 TEH TEC 30 21 DNI 06H 0.02 1.35 46 P1 TEH TEC 30 22 DSI 02H 0.00 0.21 43 P1 TEH TEC 30 25 DNI 05H
-0.22 1.33 11 P1 TEH TEC 30 25 SCI TSH
-0.20 0.13 126 0.96 0.08 91 P2 TSH TSH 30 28 DSI 03H 0.00 0.23 153 P1 TEH TEC 30 38 DSI 02H
-0.02 0.20 144 P1 TEH TEC 30 38 DNI 06H
-0.02 1.38 25 P1 TEH TEC 30 40 SCI TSH
-0.10 0.21 145 1.10 0.15 102 P2 TSH TSH 30 44 SCI TSH
-0.08 0.21 115 0.88 0.10 105 P2 TSH TSH 30 49 DNI 08C 0.14 1.25 12 P1 TEH TEC 30 51 DSI 08C 0.03 0.24 66 P1 TEH TEC 30 51 DNI 04C
-0.22 1.37 12 P1 TEH TEC 30 52 DNI 07C
-0.15 1.37 15 P1 STH TEC 30 58 DSI 04H 0.03 0.09 16 P1 TEH TEC 30 63 DSI 08H 0.15 0.17 127 P1 STH TEC 30 68 DSI 02H
-0.02 0.24 26 P1 TEH TEC 31 14 DSI 04H 0.08 0.31 161 P1 TEH TEC 31 18 DSI 02H 0.03 0.63 54 P1 TEH TEC 31 18 DSI 03H
-0.02 0.31 61 P1 TEH TEC 31 23 DNI 04H 0.00 1.43 51 P1 TEH TEC 31 23 DNI 06H 0.00 1.42 47 P1 TEH TEC 31 23 DNI 07H 0.00 1.27 45 P1 TEH TEC 31 24 DNI 02H 0.07 1.44 13 P1 TEH TEC 31 24 DNI 08H
-0.19 1.48 13 P1 TEH TEC 31 30 DNI 07H 0.16 1.73 13 P1 TEH TEC 31 35 DNI 04H
-0.02 1.29 15 P1 TEH TEC 31 35 DNI 06H 0.00 1.50 17 P1 TEH TEC Page 25 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 31 35 ONI 07H 0.12 1.79 9
P1 TEH TEC 31 39 ONI 05H 0.02 1.35 38 P1 TEH TEC 31 66 MCI TSH
-0.10 0.16 51 0.39 0.12 85 P2 TSH TSH 31 68 PCT AV2 0.00 16 1.17 0
P2 TEH TEC 31 68 PCT AV3 0.00 23 1.96 0
P2 TEH TEC 31 68 ONI 05C
-0.03 1.76 14 P1 TEH TEC 31 69 PCT AV3
-0.25 13 0.64 0
P2 STH TEC 31 74 SAi 02H 0.00 0.16 71 0.54 0.44 86 6
01H 02H 31 74 OSI 02H 0.10 0.39 133 P1 TEH TEC 32 22 OSI 02H 0.00 0.16 55 P1 TEH TEC 32 27 OSI 03H 0.12 0.56 47 P1 TEH TEC 32 27 ONI 04H
-0.05 1.25 14 P1 TEH TEC 32 35 OSI 06H 0.00 0.10 118 P1 TEH TEC 32 36 ONI 04H 0.00 1.14 35 P1 TEH TEC 32 36 ONI 02C 0.05 1.61 11 P1 TEH TEC 32 38 OSI 02H
-0.05 0.16 55 P1 TEH TEC 32 38 OSI 03H
-0.09 0.25 98 P1 TEH TEC 32 45 OSI 02H
-0.05 0.39 42 P1 TEH TEC 32 51 OSI 05H 0.05 0.16 115 P1 TEH TEC 32 53 OSI 03H
-0.05 0.21 40 P1 TEH TEC 32 69 NQI 01C 3.86 0.23 128 3
STH TEC 32 75 NQI 04C 19.37 2.07 84 6
TEH TEC 33 18 OSI 02H 0.00 0.13 137 P1 TEH TEC 33 18 OSI 03H
-0.05 0.29 50 P1 TEH TEC 33 22 OSI 02H 0.00 0.23 127 P1 TEH TEC 33 22 ONI 06H 0.00 1.28 55 P1 TEH TEC 33 27 OSI 06H
-0.05 0.26 115 P1 TEH TEC 33 27 ONI 07H 0.05 1.36 41 P1 TEH TEC 33 27 SAi TSH
-0.06 0.16 38 0.29 0.11 62 6
TSH TSH 33 42 OSI 05H 0.05 0.25 114 P1 TEH TEC 33 45 OSI 07H 0.05 0.21 65 P1 STH TEC 33 53 PSI 04H
-0.51 16.13 162 8
TEH TEC 33 54 OSI 06H 0.02 0.23 131 P1 STH TEC 33 57 OSI 04H
-0.02 0.25 23 P1 TEH TEC 33 63 ONI 06H 0.00 1.43 50 P1 TEH TEC 33 64 ONI 06H 0.00 1.32 48 P1 TEH TEC 33 66 OSI 02H 0.05 0.30 11 P1 TEH TEC 33 69 PCT AV2
-0.18 10 0.80 0
P2 TEH TEC 33 69 PCT AV3 0.00 12 0.99 0
P2 TEH TEC 33 69 WAR AV3 0.00 0.25 152 2
08C AV3 33 70 ONI 04H 0.00 1.26 55 P1 TEH TEC 33 70 PCT AV1 0.17 19 1.74 0
P2 TEH TEC 33 73 SCI TSH 0.00 0.11 82 0.62 0.23 21 P2 TSH TSH 33 74 PCT AV1 0.08 6
0.42 0
P2 TEH TEC Page 26 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH 3/4TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 34 24 OSI 03H 0.00 0.11 92 P1 TEH TEC 34 26 ONI 04H 0.05 1.21 26 P1 TEH TEC 34 33 ONI 02H
-0.07 1.42 25 P1 TEH TEC 34 33 ONI 03H
-0.02 1.21 50 P1 TEH TEC 34 33 ONI 04H 0.00 1.45 49 P1 TEH TEC 34 38 ONI 03H
-0.07 1.20 36 P1 TEH TEC 34 38 ONI 06H 0.00 1.31 16 P1 TEH TEC 34 40 OSI 03H 0.02 0.21 82 P1 TEH TEC 34 41 ONI 04H 0.03 1.33 37 P1 TEH TEC 34 46 PSI 03H
-0.52 16.87 166 8
TEH TEC 34 48 PCT AV2 0.00 17 0.91 0
P2 TEH TEC 34 48 PCT AV3
-0.07 16 0.81 0
P2 TEH TEC 34 48 PCT AV3 0.00 33 3.46 0
P2 TEH TEC 34 49 PSI 03H
-0.10 15.55 161 8
TEH TEC 34 49 PSI 03C 0.05 15.28 163 8
TEH TEC 34 52 OSI 02H 0.05 0.30 124 P1 STH TEC 34 52 PSI 03H
-0.54 17.18 160 8
STH TEC 34 53 OSI 02H 0.05 0.26 77 P1 STH TEC 34 56 OSI 05H
-0.02 0.28 31 P1 TEH TEC 34 66 MCI TSH 0.00 0.00 182 1.39 0.14 78 P2 TSH TSH 34 70 PCT AV1 0.02 17 0.91 0
P2 TEH TEC 34 70 PCT AV2 0.26 21 1.37 0
P2 TEH TEC 34 70 PCT AV3 0.29 23 1.57 0
P2 TEH TEC 35 32 ONI 07H 0.14 1.21 14 P1 TEH TEC 35 38 ONI 03H 0.10 1.19 33 P1 TEH TEC 35 42 DNI 08H 0.10 1.96 14 P1 TEH TEC 35 45 OSI 02H
-0.22 0.80 131 P1 TEH TEC 35 45 ONI 04H 0.10 1.52 33 P1 TEH TEC 35 45 DNI 05H 0.02 1.63 41 P1 TEH TEC 35 45 DNI 06H 0.03 1.82 34 P1 TEH TEC 35 45 ONI 07H 0.02 2.05 29 P1 TEH TEC 35 45 ONI 08H
-0.02 1.58 18 P1 TEH TEC 35 46 PSI 03H
-0.12 7.99 63 8
TEH TEC 35 50 PSI 03H
-0.04 7.99 50 8
TEH TEC 35 51 PSI 03H
-0.04 7.65 43 8
TEH TEC 35 51 PSI 08H
-0.02 7.83 43 8
TEH TEC 35 54 PSI 07H 0.39 8.01 69 8
TEH TEC 35 54 CSI 07H 0.00 74.52 267 10 07H 07H 35 70 PCT AV3
-0.20 13 1.08 0
P2 TEH TEC 35 72 PCT AV1 0.68 17 1.54 0
P2 TEH TEC 35 72 PCT AV3 0.00 16 1.35 0
P2 TEH TEC 36 23 DNI 06H
-0.12 1.55 20 P1 TEH TEC 36 28 OSI 03H
-0.02 0.38 83 P1 TEH TEC 36 28 OSI 04H 0.05 0.10 70 P1 TEH TEC Page 27 of30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 36 28 ONI 07H 0.00 1.22 49 P1 TEH TEC 36 31 ONI 06H 0.15 1.43 19 P1 TEH TEC 36 37 ONI 02H 0.15 1.49 16 P1 TEH TEC 36 37 ONI 03H 0.00 1.45 38 P1 TEH TEC 36 44 OSI 03H 0.00 0.27 41 P1 TEH TEC 36 46 OSI 06H 0.05 0.19 102 P1 TEH TEC 36 46 ONI 07H 0.00 1.34 49 P1 TEH TEC 37 26 ONI 07H 0.07 1.35 17 P1 TEH TEC 37 30 OSI 08H 0.00 0.16 30 P1 TEH TEC 37 39 OSI 02H
-0.02 0.18 123 P1 TEH TEC 37 39 OSI 03H
-0.02 0.20 88 P1 TEH TEC 37 42 OSI 03H 0.00 0.28 77 P1 TEH TEC 37 43 ONI 03H 0.00 1.79 35 P1 TEH TEC 37 43 ONI 06H 0.14 1.52 22 P1 TEH TEC 37 43 ONI 07H 0.00 1.31 44 P1 TEH TEC 37 43 PCT AV1 0.30 14 1.21 0
P2 TEH TEC 37 46 ONI 06H 0.02 1.25 45 P1 TEH TEC 37 53 ONI 06H 0.22 1.51 10 P1 TEH TEC 37 53 ONI 07H 0.00 1.18 29 P1 TEH TEC 37 54 ONI 04H 0.00 1.41 47 P1 TEH TEC 37 54 OSI 05H 0.00 0.13 125 P1 TEH TEC 37 54 ONI 06H 0.00 1.36 50 P1 TEH TEC 37 56 OSI 02H
-0.02 0.15 34 P1 TEH TEC 37 56 OSI 03H 0.03 0.38 57 P1 TEH TEC 37 56 ONI 04H 0.00 1.57 52 P1 TEH TEC 37 56 ONI 08H 0.02 1.33 38 P1 TEH TEC 37 60 ONI 07C
-0.20 1.62 14 P1 TEH TEC 37 66 SCI TSH 0.00 0.00 182 1.39 0.16 54 P2 TSH TSH 38 26 ONI 05H 0.05 1.50 17 P1 TEH TEC 38 37 ONI 03H 0.07 1.74 26 P1 TEH TEC 38 37 ONI 04H
-0.02 1.94 33 P1 TEH TEC 38 37 ONI 07H 0.05 1.41 33 P1 TEH TEC 38 40 OSI 05H 0.03 0.32 117 P1 TEH TEC 38 44 OSI 02H
-0.02 0.19 39 P1 TEH TEC 38 45 ONI 06H 0.02 1.23 43 P1 TEH TEC 38 45 ONI 07H 0.00 1.41 39 P1 TEH TEC 38 48 ONI 02H
-0.05 1.26 23 P1 TEH TEC 38 48 ONI 03H 0.05 1.69 14 P1 TEH TEC 38 48 ONI 05H 0.16 1.58 11 P1 TEH TEC 38 48 ONI 07H 0.13 1.40 9
P1 TEH TEC 38 52 ONI 03H 0.23 1.86 15 P1 TEH TEC 38 52 ONI 06H
-0.23 1.25 18 P1 TEH TEC 38 52 ONI 07H
-0.10 1.79 22 P1 TEH TEC 38 52 ONI 08H 0.03 1.22 37 P1 TEH TEC Page 28 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOLTS (Degrees) CHAN FROM TO 38 64 PCT AV2 0.27 19 1.14 0
P2 TEH TEC 38 64 PCT AV3
-0.16 14 0.70 0
P2 TEH TEC 38 64 WAR AV3
-0.16 0.23 122 2
08C AV3 38 72 PCT AV1 0.23 11 0.49 0
P2 TEH TEC 38 72 PCT AV2
-0.13 12 0.55 0
P2 TEH TEC 39 23 OSI 02H 0.02 0.98 31 P1 TEH TEC 39 31 ONI 04H 0.15 1.39 17 P1 TEH TEC 39 32 ONI 07H
-0.16 1.38 18 P1 TEH TEC 39 38 PCT AV3
-0.03 14 0.68 0
P2 TEH TEC 39 39 ONI 04H 0.05 1.36 48 P1 TEH TEC 39 39 ONI 05H 0.00 1.26 46 P1 TEH TEC 39 39 ONI 07H 0.00 1.38 36 P1 TEH TEC 39 42 OSI 02H 0.00 0.38 57 P1 TEH TEC 39 46 OSI 02H
-0.02 0.34 149 P1 TEH TEC 39 47 OSI 02H 0.02 0.27 137 P1 TEH TEC 39 54 ONI 02H
-0.12 1.34 17 P1 TEH TEC 39 55 ONI 03H 0.00 1.34 55 P1 STH TEC 39 55 ONI 04H 0.02 1.32 54 P1 STH TEC 39 60 ONI 04H 0.00 1.25 55 P1 TEH TEC 39 61 SCI TSH 0.00 0.00 62 0.47 0.20 113 P2 TSH TSH 39 62 SCI TSH
-0.06 0.21 152 1.16 0.13 90 P2 TSH TSH 39 66 ONI 08H 0.00 1.30 40 P1 TEH TEC 39 68 PCT AV1
-0.09 8
0.64 0
P2 TEH TEC 40 29 OSI 02H 0.00 0.11 15 P1 TEH TEC 40 33 ONI 08H 0.00 1.34 29 P1 TEH TEC 40 37 OSI 03H 0.10 0.99 56 P1 TEH TEC 40 39 ONI 07H 0.07 1.57 8
P1 TEH TEC 40 39 ONI 07H 0.23 1.57 8
P1 TEH TEC 40 44 ONI 05H 0.00 1.43 37 P1 TEH TEC 40 44 OSI 06C 0.00 0.13 116 P1 TEH TEC 40 49 ONI 03H
-0.07 1.45 27 P1 TEH TEC 40 51 ONI 04H 0.00 1.44 49 P1 TEH TEC 40 54 ONI 04H 0.03 1.44 51 P1 TEH TEC 40 54 ONI 08C 0.00 1.32 15 P1 TEH TEC 40 56 ONI 06H 0.03 1.25 35 P1 TEH TEC 40 56 ONI 07H 0.00 1.37 28 P1 TEH TEC 40 65 PCT AV3 0.17 21 1.33 0
P2 TEH TEC 40 65 WAR AV3 0.17 0.30 143 2
08C AV3 40 66 PCT AV1 0.00 21 1.37 0
P2 TEH TEC 40 66 WAR AV1 0.00 0.71 6
2 08H AV1 40 69 PCT AV2 0.30 20 1.28 0
P2 TEH TEC 40 69 PCT AV3 0.16 22 1.43 0
P2 TEH TEC 40 69 PCT AV4 0.19 26 2.11 0
P2 TEH TEC 40 69 WAR AV4 0.19 0.52 128 2
08C AV4 Page 29 of 30
Beaver Valley Unit #2 2R20 Steam Generator Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)
LENGTH ANGLE WIDTH PHASE ROW COL IND LOC INCH
%TW (Inches) (Degrees) (Inches) VOL TS (Degrees) CHAN FROM TO 41 27 OSI 03H
-0.05 0.11 152 P1 TEH TEC 41 32 ONI 05H 0.10 1.34 20 P1 TEH TEC 41 33 ONI 05H 0.19 1.56 17 P1 TEH TEC 41 33 ONI 06H 0.22 1.23 19 P1 TEH TEC 41 52 ONI 03H 0.00 1.71 52 P1 TEH TEC 41 52 ONI 04H 0.00 1.50 42 P1 TEH TEC 41 52 ONI 05H 0.00 1.30 54 P1 TEH TEC 41 53 ONI 03H
-0.02 1.48 51 P1 TEH TEC 41 55 PSI 07H
-0.02 8.69 70 8
TEH TEC 41 55 ONI 08H 0.00 1.28 24 P1 TEH TEC 41 57 ONI 05H 0.00 1.25 34 P1 TEH TEC 41 68 PCT AV2 0.20 11 0.90 0
P2 TEH TEC 41 68 WAR AV2 0.26 0.33 304 2
08H AV2 42 37 PCT AV3
-0.16 18 1.36 0
P2 TEH TEC 42 48 SCI TSH 0.00 0.18 122 0.93 0.33 59 P2 TSH TSH 42 49 SCI TSH
-0.04 0.21 149 1.14 0.11 83 P2 TSH TSH 42 64 OSI 04H 0.03 0.26 57 P1 TEH TEC 43 40 PSI 08H
-0.05 9.14 66 8
TEH TEC 43 42 PCT AV1 0.25 16 1.44 0
P2 TEH TEC 43 44 ONI 04H
-0.02 1.31 53 P1 TEH TEC 43 45 ONI 04H 0.07 1.32 15 P1 TEH TEC 43 50 ONI 03H
-0.07 1.47 25 P1 TEH TEC 43 54 ONI 04H
-0.10 1.32 25 P1 TEH TEC 43 54 PSI 01C
-0.45 6.44 50 8
TEH TEC 43 56 PCT AV3 0.26 11 0.87 0
P2 TEH TEC 43 57 PCT AV1 0.24 14 1.21 0
P2 TEH TEC 44 35 OSI 03H
-0.05 0.18 119 P1 TEH TEC 44 40 OSI 05C 0.09 0.18 142 P1 TEH TEC 44 42 PCT AV1 0.18 18 1.04 0
P2 TEH TEC 44 42 PCT AV2 0.25 26 1.98 0
P2 TEH TEC 44 48 PCT AV1 0.10 14 0.67 0
P2 TEH TEC 44 48 PCT AV2
-0.31 16 0.83 0
P2 TEH TEC 44 50 ONI 03H
-0.22 1.05 24 P1 TEH TEC 44 55 PCT AV3
-0.02 25 1.85 0
P2 TEH TEC 44 55 PCT AV4
-0.25 27 2.23 0
P2 TEH TEC 44 55 WAR AV3 0.02 0.27 111 2
08C AV3 44 55 WAR AV4
-0.25 0.57 123 2
08C AV3 44 58 OSI 06H 0.05 0.14 13 P1 TEH TEC 45 40 PCT AV1 0.37 36 4.34 0
P2 TEH TEC 45 55 PSI 06H
-0.02 16.35 165 8
TEH TEC 46 52 OSI 06H 0.03 0.23 51 P1 TEH TEC Page 30 of 30