ML19085A495

From kanterella
Jump to navigation Jump to search
COL Docs - NRC Feedback from Todays Public Meeting (Vogtle Planned LAR on AP1000 Radiation Reconciliation)
ML19085A495
Person / Time
Site: Vogtle  
Issue date: 03/26/2019
From:
NRC
To:
NRC/NRO/DLSE/LB4
References
Download: ML19085A495 (3)


Text

1 Vogtle PEmails From:

Habib, Donald Sent:

Tuesday, March 26, 2019 2:19 PM To:

Chamberlain, Amy Christine Cc:

Vogtle PEmails; Stutzcage, Edward; Dudek, Michael; Dixon-Herrity, Jennifer; Patel, Chandu; Ray, Sheila

Subject:

NRC Feedback from Today's Public Meeting (Vogtle Planned LAR on AP1000 Radiation Reconciliation)

Amy -

Below is additional NRC feedback from todays public meeting discussion about the planned LAR for detailed AP10000 radiation reconciliation.

Don Habib U.S. Nuclear Regulatory Commission Office of New Reactors Project Manager NRO/DLSE, Licensing Branch 2 O-8D13 301-415-1035 NRC Takeaway #1 -

Design basis radiation sources over 100 millicuries, that are associated with a component which is part of the plant design and requires radiation shielding and/or radiation protection controls, are included in the application. Specifically, NRC SRP Section 12.2 states, Descriptions should be provided for all radiation sources that require (1) shielding, (2) special ventilation systems, (3) special storage locations and conditions, (4) traffic or access control, (5) special plans or procedures, or (6) monitoring equipment. The source descriptions should include all pertinent information required for (1) input to shielding codes used in the design process, (2) establishment of related facility design features, (3) development of plans and procedures, (4) assessment of occupational exposure and (5) determination of radiation dose to electrical equipment important to safety as described in 10 CFR 50.49. Unless described within other sections of the SAR, source descriptions should include the methods, models and assumptions used as the bases for all values provided in SAR Section 12.2. A listing of isotope, quantity, form, and use of all required radiation sources containing byproduct, source, and special nuclear material exceeding 3.7 E+9 Bq (100 millicuries) that may warrant shielding design consideration, should be provided.

NRC Takeaway #2 -

The basis for requesting this information includes several regulations, including 10 CFR 52.47(a)(5) (for DCDs) and 10 CFR 52.79(a)(3) (for COLs), which requires that applications contain the kinds and quantities of radioactive materials expected to be produced in the operation and the means for controlling and limiting radioactive effluents and radiation exposure within the limits set forth in Part 20 of this chapter.

NRC Additional Suggestions -

In addition, the NRC staff identifies that the LAR should also discuss if there is a need for any inspections or work inside the tank; and any impacts on worker dose and worker dose estimates (depending how the worker

2 dose estimates in FSAR Section 12.4 were performed and the consideration of the radioactivity in the IRWST for how it may impact those numbers). This should also include whether there are any special radiation protection design features or controls associated with reducing the dose rate in and around the tank or reducing radiation exposure to workers in or around the tank.

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

435 Mail Envelope Properties (SN4PR0901MB2175A1044200F4AF00FA2C63975F0)

Subject:

NRC Feedback from Today's Public Meeting (Vogtle Planned LAR on AP1000 Radiation Reconciliation)

Sent Date:

3/26/2019 2:19:02 PM Received Date:

3/26/2019 2:19:05 PM From:

Habib, Donald Created By:

Donald.Habib@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None "Stutzcage, Edward" <Edward.Stutzcage@nrc.gov>

Tracking Status: None "Dudek, Michael" <Michael.Dudek@nrc.gov>

Tracking Status: None "Dixon-Herrity, Jennifer" <Jennifer.Dixon-Herrity@nrc.gov>

Tracking Status: None "Patel, Chandu" <Chandu.Patel@nrc.gov>

Tracking Status: None "Ray, Sheila" <Sheila.Ray@nrc.gov>

Tracking Status: None "Chamberlain, Amy Christine" <ACCHAMBE@southernco.com>

Tracking Status: None Post Office:

SN4PR0901MB2175.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2808 3/26/2019 2:19:05 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: