ML19071A107
| ML19071A107 | |
| Person / Time | |
|---|---|
| Site: | Surry |
| Issue date: | 03/04/2019 |
| From: | Garver R Virginia Electric & Power Co (VEPCO) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 19-093 | |
| Download: ML19071A107 (6) | |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 MAR O 4 20fi9 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 2 Serial No.
SPS-LIC/CGL Docket No.
License No.
INSERVICE INSPECTION OWNER'S ACTIVITY REPORT (OAR)19-093 RO 50-281 DPR-37 In accordance with the requirements of ASME Code Case N-532-5, Virginia Electric and Power Company (Dominion Energy Virginia) hereby submits the lnservice Inspection Owner's Activity Report (Form OAR-1) for Surry Unit 2 refueling outage S2R28, which ended on December 6, 2018. This document contains the reporting requirements for the first refueling outage of the second period in the fifth ten-year inservice inspection interval for Surry Unit 2.
If you have any questions concerning this information, please contact Mrs. Candee G. Lovett at (757) 365-2178.
Very truly yours, Rob M. Garver II Director Station Safety & Licensing Surry Power Station
Attachment:
Owner's Activity Report (Form OAR-1),
Surry Unit 2 Refueling Outage S2R28, Second Period of the Fifth ISi Interval Commitments made in this letter:
None
cc:
U.S. Nuclear Regulatory Commission Region II Marquis One. Tower*
245 Peachtree Center Avenue NE Suite 1200 Atlanta, Georgia 30303-1257
- NRC Senior Resident Inspector Surry Power Station Ms. K. Cotton Gross NRC Project Manager-Surry U. S. Nuclear Regulatory Commission One \\Nhite Flint North Mail Stop 08 G9A 11555 Rockville Pike Rockville, Maryland 20852-2738 Mr. James R. Hall NRC Senior Project Manager-North Anna U.S. Nuclear Regulatory Commission One White Flint North Mail.Stop 08 G-9A 11555 Rockville Pike Rockville, MD 20852-2738 Mr. R. A. Smith Authorized Nuclear Inspector Surry Power Station Serial No.: 19-093 Docket No.: 50-281 Page 2 of 2
ATTACHMENT OWNER'S ACTIVITY REPORT (FORM OAR-1 },
SURRY UNIT 2 REFUELING OUTAGE S2R28, SECOND PERIOD OF THE FIFTH ISi INTERVAL VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION ENERGY VIRGINIA)
Serial No.: 19-093 Docket No.: 50-281
CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number 2-5-2-1 (Unit 2, 5th Interval, 2nd Period, 1st Report)
Plant Surry Power Station, 5570 Hog Island Road, Surry, VA 23883 CASE N-532-5 Unit No., ____ _,,.,-""'2_,.,,-,-----
Commercial service date 05/01/1973 Refueling outage no. --~S~2=R=2~8-(if applicable) current inspection interval -------------------,-,-,--=--:--'S="'th-,,.,--,,---,---------------
C1st, 2nd, 3rd, 4th, other)
Current inspection period 2nd (1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans 2004 Edition Date and revision of inspection plans Surry Unit 2, 5th Int ISI Plan, Revision 5, January 2019 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Code Cases used for inspection and evaluation: See ISI Plan for list of Code Cases (if applicable, indudlng cases modified by case N-532 and later revisions)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of S2R28 conform to the requireme ts of Section XI.
(refueling outage number)
Signed
/ ISI Progam Owner Date __ _,,,2"-+-/.._J..,_'l_,t..... 1_j_,__ ____________ _
ner or Owner's Designee, lltle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/repla_cement activities and evaluation described in this report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
X ~
-- Commissions --------~N=B~-~79=3=3~N=S=*=IS=:~V~A=B=B3=(.,_,R,,__) _______ _
Inspector's Signature National Board, State, Province, and Endorsements
Page 1 of 1 CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-1 OWNER'S ACTIVITY REPORT Table 1 CASE N-532-5 Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service Examination Category and Item Description Evaluation Description Item Number None
Page 1 of 1 CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-1 OWNER'S ACTIVITY REPORT Table 2 CASE N-532-5 Abstract of Repair/replacement Activities Required for Continued Service Code Class Item Description Date Repair/Replacement Description of Work Completed Plan Number 1
02-RC-E-1 A-HTEXCH Primary manway stud identified with 11/15/2018 2018-182 damaged threads. Replace one primary stud and nut.
3 02-SW-PP-48.00-WS-Engineering identified one through-11/11/2018 2018-178 PIPE-102-10 wall corrosion pit identified in line 48.00-WS-102-10.
3 02-SW-PP-8.00-WS-PIPE-Perform weld repairs as instructed by 11/13/2018 2018-184 488-21X Base Metal Repair sheet. Weld repair required on 8"-WS-488-21X weldolet connection to 36"-WS-104-10.