MONTHYEARML19064B2652019-03-14014 March 2019 Summary of February 28, 2019, Public Meeting with Pacific Gas and Electric Company to Discuss the Proposed Relief Request Concerning Reactor Vessel Internal Visual Examination for the Diablo Canyon Nuclear Power Plant, Units 1 & 2 Project stage: Meeting 2019-03-14
[Table View] |
|
---|
Category:Meeting Summary
MONTHYEARML24157A0252024-07-0101 July 2024 Memo to Michelle Rome Summary of 4/4/2024 Meeting with CA Shpo ML24143A1202024-06-0303 June 2024 Memo to Michelle Rome Summary of 4/5/2024 Meeting with Ytt ML24108A1472024-05-0707 May 2024 February 2024 Diablo Canyon Public Scoping Meetings - Summary ML24108A1482024-05-0707 May 2024 February 2024 Environmental Scoping Meetings Related to the Diablo Canyon LRA - Memo ML24081A3362024-03-22022 March 2024 Summary of March 7, 2024, Closed Presubmittal Meeting with Pacific Gas and Electric Company Alternative Security Measures for Early Warning System License Amendment and Exemption Requests for Diablo Canyon Units 1 and 2 ML23268A4072023-09-27027 September 2023 Summary of September 19, 2023, Closed Public Meeting with Pacific Gas and Electric Company Regarding Alternative Security Measures for Early Warning System License Amendment Request for Diablo Canyon Nuclear Power Plant, Units 1 and 2 ML23265A1902023-09-26026 September 2023 Meeting Summary: September 13, 2023 Diablo Canyon, Units 1 and 2 License Renewal Application Pre-Application Meeting ML23143A2262023-06-0101 June 2023 May 3, 2023, Summary of Public Meeting to Discuss the End of Cycle Assessment and Pre-Submittal License Renewal Process Overview for Diablo Canyon Power Plant, Units 1 and 2 ML22272A5072022-09-29029 September 2022 Summary of September 27, 2022, Closed Meeting with Pacific Gas and Electric Company Regarding Planned Security Plan Changes for Diablo Canyon Nuclear Power Plant, Units 1 and 2 ML22147A0932022-06-0606 June 2022 2021 Annual Assessment Public Meeting Summary ML22126A0162022-05-0909 May 2022 Summary of April 27, 2022, Closed Teleconference with Pacific Gas and Electric Company Regarding Alternative Security Measures for Early Warning System License Amendment Request for Diablo Canyon Nuclear Power Plant, Units 1 and 2 ML21246A0202021-09-0808 September 2021 Summary of August 30, 2021, Pre-Submittal Teleconference with Pacific Gas and Electric Company Regarding a Post-Shutdown Emergency Plan License Amendment Request for Diablo Canyon Nuclear Power Plant, Units 1 and 2 ML21140A3892021-05-24024 May 2021 Riv Column 1 EOC 2020 Public Meeting Summary ML20332A1802020-12-0101 December 2020 Summary of November 24, 2020, Pre-Submittal Teleconference with Pacific Gas and Electric Company a Permanently Defueled Technical Specification License Amendment Request ML20231A6522020-08-24024 August 2020 Summary of Teleconference with Pacific Gas & Electric Company Regarding an Exigent Amendment Request to Modify Diablo Canyon Power Plant, Units 1 & 2, Technical Specification 3.7.5, Auxiliary Feedwater (AFW) System EPID L-2020-LLA-017 ML20189A2832020-07-0707 July 2020 Summary of Region IV Annual Assessment Public Meeting ML19318F5272019-11-15015 November 2019 Summary of the August 27, 2019, Public Meeting Near the Diablo Canyon Nuclear Power Plant Regarding the Establishment and Operation of Community Advisory Boards ML19196A0742019-07-22022 July 2019 Summary of Meeting with Pacific Gas and Electric Company Regarding Forthcoming Activities Associated with Diablo Canyon Nuclear Power Plant, Units 1 and 2 Planned Decommissioning ML19064B2652019-03-14014 March 2019 Summary of February 28, 2019, Public Meeting with Pacific Gas and Electric Company to Discuss the Proposed Relief Request Concerning Reactor Vessel Internal Visual Examination for the Diablo Canyon Nuclear Power Plant, Units 1 & 2 ML18348A4202018-12-31031 December 2018 Summary of Meeting with Pacific Gas & Electric Co. to Discuss Exemption Request to Withdraw Funds from the Nuclear Decommissioning Trusts to Fund Decommissioning Planning Activities at Diablo Canyon Nuclear Power Plant ML18207A7332018-08-10010 August 2018 Summary of Pre-Licensing Meeting with PG&E Co. to Discuss the Proposed LAR to Implement WCAP-16996-A, Revision 1, Realistic LOCA Evaluation Methodology Applied to the Full Spectrum of Break Sizes at Diablo Canyon ML17198A6032017-07-17017 July 2017 Summary of Annual Assessment Meeting Regarding Diablo Canyon Power Plant 2016 Performance ML16190A1782016-07-0808 July 2016 Summary of Annual Assessment Town Hall Meeting and Public Outreach Regarding Diablo Canyon Power Plant 2015 Performance ML16011A2042016-01-14014 January 2016 Summary of Conference Call on January 7, 2016, Between the U.S. NRC and Pacific Gas and Electric Co. Concerning the Responses to RAI for the Review of the Diablo Canyon Power Plant, Units 1 and 2, License Renewal Application (CAC Nos. MF401 ML15343A1272015-12-24024 December 2015 Summary of Meeting with Pacific Gas and Electric to Discuss Diablo Canyon, Units 1 and 2 Amendment Request to Revise UFSAR for Beacon Power Distribution Monitoring System Methodology and TS 5.6.5 (COLR) Paragon and Nexus Methodologies ML15348A1702015-12-17017 December 2015 Summary of Telephone Conference Call Held Between NRC and Pacific Gas and Electric Co., Concerning the RAI Responses Pertaining to the Diablo Canyon Power Plant LRA Environmental Review ML15280A2842015-10-20020 October 2015 Summary of Meeting with Pacific Gas & Electric to Discuss Diablo Canyon, Units 1 and 2 Request to Adopt National Fire Protection Association NFPA 805, Performance-Based Standard for Fire Protection for LWR Generating Plants (2001 Edition), ML15279A4222015-10-0909 October 2015 Summary of 8/25/15 Meeting with Pacific Gas and Electric to Discuss Diablo Canyon Units 1 and 2 Amendment Request to Adopt Risk-Informed Completion Times, TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times-RITSTF Initiati ML15275A1302015-10-0707 October 2015 Summary of the Site Audit Related to the Diablo Canyon Power Plant, Units 1 and 2 License Renewal Environmental Review ML15275A0942015-10-0707 October 2015 Summary of the Severe Accident Mitigation Alternatives Site Audit Related to the Diablo Canyon Power Plant, Units 1 and 2 License Renewal Review ML15233A0062015-09-10010 September 2015 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML15233A0052015-09-0909 September 2015 Summary of Meeting with Pacific Gas and Electric to Discuss Diablo Canyon, Units 1 & 2 License Amendment Request to Adopt Risk-Informed Completion Times, TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times-RITSTF. Initiati ML15233A4912015-09-0101 September 2015 August 5, 2015, Public Scoping Meetings for the Environmental Review of the Diablo Canyon Power Plant, Units 1 and 2 License Renewal Application ML15209A9442015-07-28028 July 2015 June 24, 2015, Summary of Annual Assessment Meeting with Pacific Gas and Electric and Public Open House Regarding Diablo Canyon Power Plant 2014 Performance ML15125A1862015-05-27027 May 2015 April 28, 2015, Summary of Category 1 Public Meeting with Pacific Gas and Electric Company to Discuss Diablo Canyon'S Seismic Hazard Reevaluation Associated with Implementation of Japan Lessons-Learned Near-Term Task Force Recommendation 2. ML15134A2572015-05-18018 May 2015 5/7/15 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML15092A0792015-04-16016 April 2015 July 14-17, 2014 - Summary of Diablo Canyon, Units 1 and 2, Audit to Adopt National Fire Protection Association NFPA 805, Performance-Based Standard for Fire Protection for LWR Generating Plants (2001 Edition) ML15069A0952015-03-24024 March 2015 Summary of Telephone Conference Call Held on March 4, 2015 Between the U.S. Nuclear Regulatory Commission and Pacific Gas and Electric Company Concerning the Diablo Canyon Power Plant, Units 1 and 2, License Renewal Application ML15043A1992015-02-19019 February 2015 2/3/2015 Summary of Meeting with Pacific Gas and Electric Regarding Presubmittal Discussion on Alternate Source Term License Amendment Request for Diablo Canyon Power Plant, Units 1 and 2 ML15037A2482015-02-0505 February 2015 Summary of Regulatory Conference to Discuss Safety Significance of Diablo Canyon Power Plant Protective Action Recommendations for Areas of the Ocean Finding ML14350A2712014-12-22022 December 2014 Summary of 12/11/14 Preapplication Meeting with Pacific Gas and Electric Company to Discuss License Amendment Request to Support Installation of 500 Kilovolt Output Generator Breakers at Diablo Canyon, Units 1 and 2 ML14029A4502014-12-10010 December 2014 Summary of 12/18/13 Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML14295A7332014-11-17017 November 2014 9/24/14 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML14197A3522014-07-22022 July 2014 7/9/14 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML14157A0912014-06-17017 June 2014 Summary of 5/21/14 Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML14155A3742014-06-0404 June 2014 May 22, 2014, Summary of Annual Assessment Meeting with Pacific Gas and Electric Regarding Diablo Canyon Power Plant 2013 Performance ML14113A4932014-05-0606 May 2014 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML14113A4222014-04-23023 April 2014 Public Meeting with Pacific Gas & Electric (Pg&E)To Discuss the Operating Performance for Diablo Canyon Power Plant for the Period January 1 - December 31, 2013 ML13329A4172013-12-30030 December 2013 Summary of Meeting with Pacific Gas and Electric Company to Discuss Digital Replacement of Process Protection System at Diablo Canyon Power Plant, Units 1 and 2 ML13354C0912013-12-23023 December 2013 Summary of Annual Assessment Meeting with Pacific Gas & Electric Re Diablo Canyon Nuclear Power Plant 2012 Performance 2024-07-01
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 14, 2019 LICENSEE: Pacific Gas and Electric Company FACILITY: Diablo Canyon Nuclear Power Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF FEBRUARY 28, 2019, PRESUBMIITAL TELECONFERENCE MEETING WITH PACIFIC GAS AND ELECTRIC COMPANY TO DISCUSS A PROPOSED RELIEF REQUEST CONCERNING REACTOR VESSEL INTERNAL VISUAL EXAMINATION FOR THE DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2 (EPID L-2019-LRM-0009)
On February 28, 2019, a Category 1 public meeting was held by teleconference between the U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Pacific Gas and Electric Company (PG&E, the licensee). The purpose of the meeting was to discuss a proposed relief request concerning reactor vessel internal visual examination for the Diablo Canyon Nuclear Power Plant, Units 1 and 2 (DCPP). The meeting notice and agenda, dated February 14, 2019, are available in the Agencywide Documents Access and Management System Accession No. ML19045A004. No formal presentation slides were used during the meeting. Enclosed is a list of attendees.
During the meeting, the following information was discussed, which will be included in the proposed relief request:
- Table IWB-2500-1, Examination Category B-N-1, Item B13.10, of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (ASME Code),Section XI, requires a periodic visual VT-3 examination. The ASME Code requires that this examination be performed each inspection period (3~ years) on average after the first inspection interval.
- The proposed relief request is to propose an alternative to the visual VT-3 examination specified by ASME Code,Section XI, for Examination Category B-N-1 for the remainder of the fourth inservice inspection interval under Title 1O of the Code of Federal Regulations paragraph 50.55(a)(z)(1 ), "Acceptable level of quality and safety."
- The licensee stated that the Electric Power Research Institute (EPRI) assessment, documented by Report 3002012966, 1 "Evaluation of Basis for Periodic Visual Examination of Accessible Areas of Reactor Vessel Interior per Examination Category B-N-1of ASME Section XI, Division 1," documents the basis and benefit of the periodic visual VT-3 examination of the reactor 1 The EPRI report may not be publically available. Also, the EPRI report has not been endorsed by the NRC staff.
2 vessel interior specified for ASME Examination Category B-N-1. As determined by a review of the historical evolution of the requirements for Examination Category B-N-1, the purpose of this examination is to detect foreign material and debris in the interior of the reactor vessel. The EPRI report concludes that other industry requirements and guidance are sufficient for the purposes of detecting and removing foreign material and debris in the reactor vessel.
- Foreign material and debris examinations are not directly related to vessel integrity and are routinely performed during refueling outages at DCPP through core plate foreign object search and retrieval, core verification, and other maintenance activities. The practices at DCPP during refueling outages to exclude foreign material and to detect and remove foreign material and debris from the interior of the reactor vessel and fuel assemblies are sufficient to provide an acceptable level of quality and safety in lieu of the ASME Examination Category B-N-1 visual VT-3 examination requirement.
- The licensee further stated that ASME is in the process of approving a code case eliminating the need for the visual VT-3 examination specified by the Code. The licensee believes that the NRC staff has also voted in favor of the code case.
However, a code case has not been published at this time.
- The licensee stated that the proposed alternative meets the requirements of 10 CFR 50.55a(z)(1) and provides an acceptable level of quality and safety.
The NRC staff stated that since the referenced EPRI report used as the basis for justification for the proposed alternative has not been endorsed by the NRC staff, the request needs to address all the qualitative analysis included in the EPRI report on a plant-specific basis, and the submittal has to be a stand-alone document without references to the analysis included in the EPRI report. Any additional supporting analysis performed by the licensee or Westinghouse should also be included in the submittal.
The purpose of the meeting was to exchange technical information and no regulatory decisions were made during the meeting.
The licensee indicated that the request will be submitted to the NRC staff before the end of March 2019, and requested the NRC staff to complete its review by October 1, 2019. The staff indicated that it will try its best to support the licensee's requested date. The staff stated that a high quality submittal that does not require requests for additional information, will assist the staff in meeting the licensee's requested date Public Comments The following comments were made by some of the members of the public on teleconference.
Comment 1 Mr. Marvin Lewis indicated that Framatome has developed an Angle Beam Ultrasonic Probe technique (no details provided), and suggested that the licensee should be asked to use this technique instead of eliminating the visual VT-3 examination required by the ASME Code. The NRC staff indicated that the examination technique, suggested by Mr. Lewis, qualifies as volumetric examination and cannot be considered as a replacement for visual VT-3
3 examination. However, this comment does not apply to the topic of discussion. Mr. Lewis stated that he disagreed with the NRC staff and did not ask for any further clarification Comment 2 Ms. Linda Seeley was concerned about NRC staff authorizing fewer inspections instead of asking for more. The NRC stated that the purpose of the call is to exchange technical information. At this time no regulatory decision is being made by the NRC and no official submittal has been made by the licensee. The NRC staff further stated that they will review the request when submitted and will make its decision based on the information and justification provided by the licensee in its application. The decision will be based on maintaining an acceptable level of quality and safety as required by the regulation at 10CFR 50.55a(z)(1 ).
Additionally, the NRC staff discussed that they are not obligated to approve the request if it does not satisfy the requirements of the regulations.
Ms. Seeley asked if the NRC staff has ever denied such requests. The staff replied that the NRC has denied relief request in the past. Ms. Seeley further asked if the staff has ever denied any such request for DCPP. The staff stated that they can answer this question only after review of plant records. Ms. Seeley did not have any further questions.
Comment 3 Ms. Donna Gilmore asked the NRC staff to explain the reason for performing the visual VT-3 examinations. The NRC staff stated that the purpose is to identify any loose parts or foreign materials inside the reactor vessel. Ms. Gilmore asked what will be the consequences if any foreign materials go undetected. The NRC staff stated that most of the time there will not be any significant consequences, and that the foreign materials are likely to be detected and removed during the following refueling outage. In a worst case scenario, the foreign materials may result in some fuel cladding damage resulting in fuel leak. However, cladding is only one of the three barriers and there should be no dose consequence to the public.
No Public Meeting Feedback forms were received.
Please direct any inquiries to me at 301-415-3016 or via e-mail at Balwant.Singal@nrc.gov.
~i-~,\,\;~
Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323
Enclosure:
List of Attendees cc: Listserv
LIST OF ATIENDEES FEBRUARY 28, 2019, PRESUBMITIAL TELECONFERENCE MEETING WITH PACIFIC GAS AND ELECTRIC COMPANY TO DISCUSS A PROPOSED RELIEF REQUEST CONCERNING REACTOR VESSEL INTERNAL VISUAL EXAMINATION DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2 NAME ORGANIZATION David Alley NRC 1 (NRR)2 David Dijamco NRC (NRR)
Simon Sheng NRC (NRR)
Mark Yoo NRC (NRR)
Balwant Singal NRR (NRR)
David Gonzalez PG&E 3 James Hill PG&E Michael Richardson PG&E Rama Thatipamala PG&E Robert Grizzi EPRl 4 Chris Joffe EPRI Gary Stevens EPRI Markus Burkardt Dominion Engineering5 Glenn White Dominion Engineering Donna Gilmore Member of the Public Marvin Lewis Member of the Public Linda Seeley Member of the Public 1 U.S. Nuclear Regulatory Commission (NRC) 2 Office of Nuclear Reactor Regulation (NRR) 3 Pacific Gas and Electric Company (PG&E) 4 Electric Power Research Institute (EPRI) 5 Representing PG&E Enclosure
SUBJECT:
SUMMARY
OF FEBRUARY 28, 2019, PRESUBMITIAL TELECONFERENCE MEETING WITH PACIFIC GAS AND ELECTRIC COMPANY TO DISCUSS A PROPOSED RELIEF REQUEST CONCERNING REACTOR VESSEL INTERNAL VISUAL EXAMINATION FOR THE DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2 (EPID L-2019-LRM-0009) DATED MARCH 14, 2019 DISTRIBUTION:
PUBLIC PM File Copy RidsACRS_MailCTR Resource RidsNrrDorl Resource RidsNrrDorlLpl4 Resource RidsNrrLAPBlechman Resource RidsNrrPMDiabloCanyon Resource RidsRgn4MailCenter Resource RidsNrrDmlrMvib Resource DDijamco, NRR SSheng, NRR MYoo, NRR JLarsen, RIV MMcCoppin, OEDO RIV ADAMS A ccess1on Nos.: M eetmg Not1ce:
. ML19045A004 S ummary: ML190648265 *via
. e-ma1*1 OFFICE NRR/DORL/LPL4/PM NRR/DORL/LPL4/LAit NRR/DORL/LPL4/LA NAME BSingal KZeleznock PBlechman DATE 03/11/19 03/08/19 03/01/19 OFFICE NRR/DLPM/MVIB/BC NRR/DORL/LPL4/BC NRR/DORL/LPL4/PM NAME DAIiey RPascarelli BSingal DATE 03/05/19 03/14/19 03/14/19 OFFICIAL RECORD COPY .