WAmeren Callaway Plant MISSOURI Februa1y 20, 2019 ULNRC-06488 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington., DC 20555-0001 10 CPR 50.47 10 CFR 50.54(q)

IO CPR 50 Appendix E, IV.B.2 10 CFR 50.90 Ladies and Gentlemen:

DOCKET NUMBERS 50-483 AND 72-1045 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.

RENEWED FACILITY OPERATING LICENSE NPF-30 SUPPLEMENT AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE AMENDMENT REQUEST FOR EMERGENCY ACTION LEVEL (EAL) CHANGES

References:

1) ULNRC-06433, "License Amendment Request for Emergency Action Level (EAL) Changes," dated September 4, 2018 (ADAMS Accession No. ML18247A467)
2) Conespondence from Jolm Klos to Tom Elwood, "Formal release of RAI Ref:

Callaway Plant EAL changes L-2018-LLA-0239," dated December 20, 2018 (ADAMS Accession No. ML18355A488)

3) NEI 99-01, "Development of Emergency Action Levels for Non-Passive Reactors," Revision 6, dated November 2012 (ADAMS Accession No. ML12326A805)
4) EPFAQ 2016-002, "Clarification of Equipment Damage as a Result of a Hazardous Event" (ADAMS Accession No. MLI 7195A299)
5) EPFAQ 2018-004, EPFAQ 2018-04 Clarification ofHazardous Events and Safety Systems Concunence Package for Public Comment Release," dated May 3 J, 2018 (ADAMS Accession No. ML! 8268A168)

Per Reference 1, Union Electric Company (Ameren Missouti) submitted a 1icense amendment request for an emergency action level (EAL) scheme change for Callaway Plant (Callaway). Specifica11y Ameren Missouri proposed changes to EALs CA6. l, "Cold Shutdown / Refueling System Malfunction 83 15 County Road 459 Steedman MO 65077 AmerenMissouri.com

ULNRC-06488 February 20, 2019 Page 2 of 5

- Hazardous event affecting a SAFETY SYSTEM needed for the cmTent operating MODE: Alert,"

and SA9.1, "System Malfunction - Hazardous event affecting a SAFETY SYSTEM needed for the cunent operating MODE: Alert" (including addition of a new definition for the tenn "Loss of Safety Function (LOSF)" and re-definition of the tenn "Visible Damage"), along with deletion of Initiating Condition (IC) HG 1 and associated EAL HG 1.1, "Hazard - HOSTILE ACTION resulting in loss of physical control of the facility: General Emergency," in connection with the Callaway Plant Radiological Emergency Response Plan (RERP).

Per Reference 2, the NRC staff transmitted a request for additional information (RAI) needed to facilitate the technical review being conducted by the Office of Nuclear Security and Incident Response/ Division of Preparedness and Response/Reactor Licensing Branch (NSIR/DPR/RLB).

Through discussion with the NRC staff during a telephone conference on December 18, 2018, Ameren Missouri proposed to revise its original LAR such that the verbiage that had been provided for the requested EAL changes regarding "Loss of Safety Function" would be replaced with verbiage that is consistent with Reference 3, as modified in accordance with the NRC staff guidance provided in Reference 4.

When the originally proposed verbiage was replaced in order to effect alignment with the noted NRC-recognized guidance, Ameren Missouri also considered additional NRC-recognized guidance, as provided in Reference 5, which is applicable to the proposed changes. Changes per the latter would add clarification text to the Bases for EALs CA6.1 an SA9.1 that is consistent with Reference 5, including examples of systems and components to which the clarification applies.

All of these changes require revision of the originally proposed changes, and consequently, this letter is hereby submitted as a supplement to the original LAR. This letter also serves to provide a response to the Reference 2 RAI, notwithstanding the applicability of the RAI questions/requests to the originally proposed changes.

All required infonnation pertaining to the new changes and RAI response is provided in the attachments to this letter. Specifically, the response to the RAI is provided in Attaclunent 1 to this letter, and Attaclunents 2, 3, and 4, respectively, provide a revised evaluation of proposed EALs, revised mark-ups of proposed Callaway EAL Technical Bases Document affected pages, and revised clean copies of proposed Callaway EAL Technical Bases Document affected pages. A revised clean copy of the proposed Emergency Action Level Classification Matrix is also provided for infonnation as Attaclunent 5. The supplemental material that is provided in Attaclunents 2, 3, 4, and 5 supersedes material that had been submitted per Reference 1.

This submittal does not contain new commitments. For any questions concerning this letter, please contact Mr. Tom Elwood at 314-225-1905.

        • * *** * ****** ***** ************************ ** ******************** ************************* * **** ** ** ******* ** ******************l************ * ***************************l****************I***********************************

ULNRC-0648 8 February 20, 2019 Page 3 of 5 I declare under penalty of perjury that the foregoing is true and correct.

Sincerely Executed on: February 20, 2019

~~J~

Roger C. Wink Manager, Regulatory Affairs Attadunents: 1) Response to Request for Additional Infonnation

2) Evaluation of Proposed Emergency Action Levels
3) Mark-ups of Callaway EAL Technical Bases Document affected pages
4) Revised affected pages of EIP-ZZ-00101 Addendum 2, "Emergency Action Level Technical Bases Document," Proposed Revision 016 (Clean Copy)
5) EAL Matrix from EIP-ZZ-00101 Addendum 1, "Emergency Action Level Classification Matrix," Proposed Revision 009 (Clean Copy - lnfonnation Only)

ULNRC-06488 February 20, 2019 Page 4 of 5 cc:

Mr. Scott A. Morris Regional Administrator U.S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Director Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Cmmnission Washington, DC 20555-0001 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Co1mnission 8201 NRC Road Steedman, MO 65077 Mr. L. J olm Klos Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 09E3 Washington, DC 20555-0001 Senior Emergency Preparedness Analyst U.S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511

:; : ::::.: ::: ; :::: ::: ~.: :.: :: :. :: : : : : : : : : : :: :. : : : :: :::.: **:::;:: ::. *: :: : : :. ;: =~.. :: ::.~ :::.. ; : :::::,; :: ~::::::: :::;.. : :.:. :: ::::::: :::: ::::~:::. ::. ::; : ::. ~::.:;::: ;:: : ::.:.. ::::: :: :. ; :::::: ::::::: ::: ;~::.: ;;;:::: :: ::: :: :: : :

ULNRC-0648 8 February 20, 2019 Page 5 of 5 Index and send hardcopy to QA File Al60.0761 Hard copy:

Certrec Corporation 6100 Western Place, Suite 1050 Fort Worth, TX 76107 (Certrec receives ALL attachments as Jong as they are non-safeguards and may be publicly disclosed.)

Electronic distribution for the following can be made via RERP ULNRC Distribution:

F. M. Diya T. E. Hernna1U1 B. L. Cox F. J. Bianco S. P. Banker G. P. Rauch R. C. Wink T. B. Elwood T. R. Wiltman Corporate Communications NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)

Missouri Public Service Cmrunission Mrs. Collette Linder, REP Manager (SEMA)

.:: ::: ::; : :::: ;~::: ~;::. : :::::. :: :::::*: ::::.: :.::* :::*.. ::: :::: ~:;: ::. : : :: ;:. ::* '.:: :* '. :::* : :::; ~= :: :: : ::: :.:::: :: : ::: :::;:: ~ :*.. :::.:: :::.::: :: : :.::. :;.:::.:::. ::: : :. ::: : ::::: :::.:.. :: ::::.::. :: : ::. :.:: :.: : : :. ::.. ::: : :.

= :::~::: :: : : :::::::~: :::::~::: ::: ::::: :::::: :: : :: : :: : :: : :: : :! : :::::: :: : *:. :: ::: ::: ;;: :::::: :::: ::::: :: : ::::::; ::: ::: : : ;: :: ::: ::: ::: :

~ ::::::~::::::::; :: :::: :;; ::::;;:~ ::. :: :::::: :::::: :: : :::::::: :::::::: ::.: :: :: :::;:: :: :: :