NRG FORM 699 ** <>""-,.

U.S. NUCLEAR REGULATORY COMMISSION (03-2013) f)

. *



-;.-+,,

CONVERSATION RECORD NAME OF PERSON($) CONTACTED OR IN CONTACT WITH YOU Kirstein, Erik S; GE Power E-MAIL ADDRESS Erik.kirstein@ge.com ORGANIZATION GNF-A LICENSE NUMBER($)

NIA SUBJECT DATE OF CONTACT 01/1712019 TELEPHONE NUMBER (910) 819-5365 DOCKET NUMBER($)

71-3093 CONTROL NUMBER($)

NIA DATE OF SIGNATURE

.JI i  \\ \\.

TYPE OF CONVERSATION DE-MAIL 0 TELEPHONE 0 INCOMING D OUTGOING 1/1712019, 2:00 PM - CONFERENCE CALL TO DISCUSS CLAR1FICATION QUESTIONS REGARDING REQUESTS FOR SUPPLEMENTAL INFOMATION (THERMAL EVALUATION) MODEL NO. TK-C69 (DOCKET NO. 71-3093)

SUMMARY

Attendees:

GNF-A \\GE Power (TVEL's Representative in the U.S.):

Erik Kirstein, Senior Nuclear Packaging Engineer NRC:

Jimmy Chang, Thermal Reviewer Norma Garcia Santos, Project Manager Continue on Page 2 ACTION REQUIRED (IF ANY)

GNF-A would provide a time frame in which it would be submitting the response to the supplemental information. GNF-A also agreed to provide an update of the need date to complete this action. The staff noted that it could not commit to any dates at this time.

Continue on Page 3 NAME OF PERSON DOCUMENTING CONVERSff/pN Norma Nf ia Santos, Jimmy Chang,/and Erik Ki7t NRC FORx9(03-2013)

,_/

Page 1 of 2

NRG FORM 699 (03-2013)

SUMMARY

. (Continued from page 1)

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD (continued)

On January 17, 2019, GNF-A participated on a phone call with the NRC staff (thereafter, the staff) to clarify questions related to the request for supplemental information (RSI) related to the revalidation recommendation request from the U.S. Department of Transportation (DOT) for the Model No. TK-C69 transportation package. The discussion was focused on RSis Th-2, Th-4, and Th-5.

the following is a summary of the discussion with GNF-A:

RSI-Th-2 and Th-4 GNF-A asked if this question is similar to the requirement in Part 71, to demonstrate that the package will stand temperature changes from ambient temperatures to extreme cold and heat conditions. The staff pointed out that the evaluation for the package should include the effects of thermal stresses to the package under extreme cold and heat conditions as required in the IAEA regulations.

Therefore, the applicant needs to provide information about the performance of the package under these conditions. In terms ofRSI-Th-4, GNF-A mentioned that paragraph 653(b) is applicable to Type B packages and the Model No. TK-C69 would be transporting Type A contents. The staff mentioned that there is an RSI question related to confirm the type on content to be transported in the Model No. TK-C69, just to confirm that the package will be used to transport only Type A material.

RSI -Th-5 GNF-A asked if this question was focused on providing information regarding the effects of thermal stresses in the package at extreme heat conditions, since Chapter 3 of the application does not include this information. The staff pointed out that the applicant should explain how the thermal evaluation considered gaps between components and identify these gaps in its response.

The staff mentioned that adding a statement in the application about these items should be sufficient at the acceptance review phase.

GNF-A agreed to verify if the need of this action has changed and to provide an estimated time frame in which it would submit the RSI responses.