PS~G Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201/430-7000 January 18, 1978 Director of Nuclear Reactor Regulation
- u. s. Nuclear Regulatory Commission Washington, D. c.
20555 Attention:
Mr. George Lear, Chief Operating Reactors Branch #3 Division of Operating Reactors Gentlemen:
IN-SERVICE INSPECTION AND TESTING PROGRAMS UNIT NO. 1 DOCKET NO. 50-272 SALEM NUCLEAR GENERATING STATION In our letter of October 11, 1977 on In-service inspection and Testing Program, Footnote 1 of Attachment 1, Table 2; was incomplete.
Please replace Table 2 with the attached revision.
If you require additional information or clarification, please contact us.
The Energy People Very truly yours, F.~
General Manager -
Electric Production 780270046 95-2001 (400M) 9-77
/
Item No.
Cl.l Cl.2 Cl.3 Cl.4 Examination category Table XW:-2520 C-A C-B c-c
-C-D
.ld"l71CBMEm l
<:alp>nents and Parts tD be Examined Pressure V~ls l CirCllllf erential b.Jtt welds
'HOzzle-to-vessel welds Integrally-welded supports Pressure-retai.nin;i bolting C2._!
C2.2 C-F,C-G C-F, C-G I Ci........... w "".:::.""
1':lB;litudinal weld joints in fittings C2.3 C2.4 C2.5 C2.6 C3.l C3.2 C3.3 C3.4 C4.l C4.2 C4.3 C4.4 U.:jk C-F, C-G C-D C-E-1 C-E-2 C-F, C-G C-D C-E-1 C-E-2
- C-F, C-G C-D C-E-1 C-E-2 P77 71 50/53 Rev. l 10/30/77 Branch pipe-to-pipe weld joints Pressure-retaining bolting Integrally-welded supports SIJtp>rt ~nts Pimp; 1 Pulp casing welds Pressure-retaining bolting Integrally-welded suwcrts SIJtp>rt cxmponents Valves No ~ts within this category Pressure-retaining bolting Integrally-welded suwcrts
~rt 1
c:aiponents l
Class 2 CclJFonents (subject tc the exerptioo a:iteria of DC 1220)
- Charging Safety Injection Purrps 11, 12, and 13 No. 1 Reactor Coolant Filter No. 1 Excess Letdown Heat Exchanger (Tube Side)
No. l Regenerative Heat Exchanger
'HO. 1 Letdown Heat Exchanger (Tube Side) 11cc\\mllators 11, 12, 13, and 14
- -eoron Injection Tank llefueling Water Tank Safety Injection Pumps 11 and 12 mm Heat Exchangers 11 and 12 mm Pimps 11 and 12 Chemical Volume and Control Tank Bead Tanks 11, 12, 13 and 14 Jlefueling Water Storage Tank Beat Exchanger llefueling Water Storage Tank Beating Water Becirc. Pimp Contaiment $pray ~
11 and 12 Steam Generators 11, 12, 13 and 14 (Shell Side) llethod Volanetric Volumetric Surface Visual am either surface or volumetric Vol1m1etric Volumetric Volumetric Visual and either surface or wlumetric Surface Visual Volumetric Visual and either surface or volumetric Surface Visual Visual am either surface or volumetric Surface Visual
) 1