. \\ _,/

Public Service Electric and Gas Company Salem Generating Station P. 0. Box #168 Hancocks Bridge, New Jersey 08038 January 12, 1977 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

MONTHLY OPERATING REPORT SALEM NO. 1 DOCKET NO. 50-272 In compliance with Section 6.9, Reporting Requirements for the Salem Technical Specifications, and USNRC Regulatory Guide 1.16, 10 copies of the following monthly operating reports for the month of December 1976 are hereby submitted:

Appendix B -

Average Daily Unit Power Level Appendix C -

Operating Data Report Appendix D -

Unit Shutdowns and Power Reductions Sincerely yours, JJ1~

H. J. fe{1~r Manager -

Salem Generating Station CC:

Mr. James P. O'Reilly

'*ll{;.Copy)

Director of U.S. NRC

~~.

  • Off ice of Inspection and Enforcement

~

  • Region I

~~

631 Park Avenue

~\\:l,

King of Prussia, PA 19406

,?Y-~~1

--~-

~ "~~rn, Director, Office of Management~~Q6't;\\)7*

(2 Information and Program Control )'

U.S. Nuclear Regulatory Commissio ~~

Washington, D.C.

20555

~

The Energy People 95-2189 (2M) 12-74

TYPE F*

  • , FORCED NO.

DATE S: SCHEDULED

  • I

~

I

SUMMARY

(

\\.._)

e.*

APPENDIX D DOCKET NO.

5o-272 UNIT SHUTDOWNS AND POWER 'REDUCTIONS UNIT NAl\\*fE SALEM NO.1 DURATION (HOURS)

REPORT MONTH DECEMBER REASON (1)

METHOD OF SHUTTING DOWN THE REAC,TOR OR REDUCING POWER (2)

(]

  • .::::;\\
y PATE COMPLETED BY G.S. Daves Jr.

TELEPHONE 609-365-7000 Ext. 659 CORRECTIVE ACTIONS/COMMENTS 1*

~---- --------- -

  • Salem No. 1 -

Undergoing power ascension testing.

Unit has not been declared commercial.

U

, \\

I~

I

  • ,.f APPENDIX C OPERATING DATA REPORT DOCKET NO. __

5_o_-_2_7_2 ___ 0 UNIT _S_A_L_E_M_N_O_._l __ _

1-12-77,

. DATE----------

COMPLETED BY G

  • S. DAVES TELEPHONE 609-365-7000 X659 I OPERATING STATUS
1. REPORTING PERIOD:

December 1976 GROSS HOURS IN REPORTJNG PERIOD: __ 7_4_4 ____ _

2. CURRENTLY AUTHORIZED POWER LEVEL (MWt): 3 3 3 8 DESIGN ELECTRICAL RATING (MWe-Net):

1090 TO* Be MAX. DEPEND. CAPACITY (MWe-Nctl: Determined

3. POWER LEVEL TO WHICH RESTRICTED (IF ANY) (MWe-Nct): __

S_E_E_I_T_E_M--'#'--4 _____ _

. 4. REASONS FOR RESTRICTION (IF ANY);

20% of rated' core power until the ECCS Performance is reevaluated by modeling the uooer head temperature as the hot leg temperature.

THIS"MONTH YR TO DATE CUMULATIVE 5 Nu E

0 OR 301.6 30~.6 301.6 MB R OF H URS REACT WAS CRITICAL..... ;.*..*.*.* _;___;,_..:._;;,_

~*

0 0

0

6. REACTORRESERVESHUTDOWNHOURS..*.****..****..** *----
t. HOURS GENERATOR ON LINE.**..**..****..*.***.**.*.
8. UNIT RESERVE SHUTDOWN HOURS **********..**.*.**.**.
9. GROSS THERMAL ENERGY GENERATED (MWH) **....*.. : *...
10. GROSS ELECTRICAL ENERGY GENERATED (MWH)..*....*..***
11. NET ELECTRICAL ENERGY GENERATED (MWHl.*********..**
12. REACTOR SERVICE FACTOR **.*****...**.., ****..*.****.
13. REACTOR AVAILABILITY FACTOR ***.******************..

14.' UNIT SERVICE FACTOR *******, *.*.*****, *******.******

15. UNIT AVAILABILITY FACTOR ****, ********.************

Max. Dependable Capability

16. 'UNIT CAf>ACITY FACTOR (Using MDC).**.********, *********
17. UNIT CAPACITY FACTOR (Using Design MWc).******, **, ***** **
18. UNIT FORCED OUTAGE RATE..*****.***.**, ***********

4 0. 3 0

48697 3230 0

N/A N/A N/A N/A N/A N/A N/A 4 0. 3 40.3 0

0 J~

48697 4869~3 3230 3230 0

0 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NLA

19. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH): 3-18-77 Modification of low pressure turbine blading, 8 weeks.
20. IF SHUT DOWN AT'END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: 1-7-77
21. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 1.16*9 FORECAST ACHIEVED 9-30-76 12-11-76 11-01-76 12-25-76 12-20-76 ---

'.,[

J e

MONTH DECEMBER APPENDIX B AVERAGE DAILY UNIT-POWER LEVEL DOCKET NO.

50-272 UNIT Salem No. 1 DATEl-- 7 7 COMPLETED BY G.S. Daves TELEPHONE 6 o g-3 6 5-7 O O q Ext. 659 1 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Nct)

(i\\fWe-Nct) l 1

0 17 0

2 0

18 0

3 0

19 0

4 0

20 0

-(w 5

0 0

21 6

0 22 0

7 0

23

  • O 8

0 24 0

9 0

25 0

10 26 0

11 0

27 0

12 0

28 24 13 0

29 0

14 30 a*

15 0

31 0

16 0

INSTRUCTIONS

-')

On this form, list the average duily unit power lcwl in MWc-Ncl for each day in the reporting mouth. Compute to frr{

nearest whole nwgawatt.

111csc figures will be used lo plot a graph for ead1 rrpo1ling month. Note that when maximum dcpl'llll:1bll' L'apadty is used for the m'I elcl~trical rating or the unit, there may be lll'l"asions when the daily average pllwcr k*\\*d L'XCci..*ds the l OO'ii* line (or the n~strkled. powL~r k\\'el line). In sudi L~;iscs, the avc1:agl~ llaily unit power output shl'L'l slam Id he

~u~notcd to explain lilt.: app:.m:nl arw11_1:_ilY_.. ___ _