Text
AVAILABILITY OF REFERENCE MATERIALS IN NRC PUBLICATIONS NRC Reference Material As of November 1999, you may electronically access NUREG-series publications and other NRC records at NRCs Library at www.nrc.gov/reading-rm.html. Publicly released records include, to name a few, NUREG-series publications; Federal Register notices; applicant, licensee, and vendor documents and correspondence; NRC correspondence and internal memoranda; bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their attachments.
NRC publications in the NUREG series, NRC regulations, and Title 10, Energy, in the Code of Federal Regulations may also be purchased from one of these two sources.
- 1. The Superintendent of Documents U.S. Government Publishing Office Washington, DC 20402-0001 Internet: bookstore.gpo.gov Telephone: (202) 512-1800 Fax: (202) 512-2104
- 2. The National Technical Information Service 5301 Shawnee Road Alexandria, VA 22312-0002 www.ntis.gov 1-800-553-6847 or, locally, (703) 605-6000 A single copy of each NRC draft report for comment is available free, to the extent of supply, upon written request as follows:
Address: U.S. Nuclear Regulatory Commission Office of Administration Multimedia, Graphics, and Storage &
Distribution Branch Washington, DC 20555-0001 E-mail: distribution.resource@nrc.gov Facsimile: (301) 415-2289 Some publications in the NUREG series that are posted at NRCs Web site address www.nrc.gov/reading-rm/
doc-collections/nuregs are updated periodically and may differ from the last printed version. Although references to material found on a Web site bear the date the material was accessed, the material available on the date cited may subsequently be removed from the site.
Non-NRC Reference Material Documents available from public and special technical libraries include all open literature items, such as books, journal articles, transactions, Federal Register notices, Federal and State legislation, and congressional reports.
Such documents as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings may be purchased from their sponsoring organization.
Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at The NRC Technical Library Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 These standards are available in the library for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from American National Standards Institute 11 West 42nd Street New York, NY 10036-8002 www.ansi.org (212) 642-4900 Legally binding regulatory requirements are stated only in laws; NRC regulations; licenses, including technical specifications; or orders, not in NUREG-series publications.
The views expressed in contractor prepared publications in this series are not necessarily those of the NRC.
The NUREG series comprises (1) technical and administrative reports and books prepared by the staff (NUREG-XXXX) or agency contractors (NUREG/CR-XXXX),
(2) proceedings of conferences (NUREG/CP-XXXX),
(3) reports resulting from international agreements (NUREG/IA-XXXX),(4) brochures (NUREG/BR-XXXX), and (5) compilations of legal decisions and orders of the Commission and Atomic and Safety Licensing Boards and of Directors decisions under Section 2.206 of NRCs regulations (NUREG-0750).
DISCLAIMER: This report was prepared as an account of work sponsored by an agency of the U.S. Government.
Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third partys use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party would not infringe privately owned rights.
NUREG/KM-0011 Critical Heat Flux Data Used to Generate the 2006 Groeneveld Lookup Tables Office of Nuclear Regulatory Research Manuscript Completed: July 2016 Date Published: January 2019 Prepared by:
D.C. Groeneveld Thermalhydraulics Consultants, Inc.
P.O. Box 1335 Deep River, Ontario, Canada K0J 1P0
iii ABSTRACT This report contains a compilation of over 25,000 critical heat flux (CHF) data points obtained in water-cooled tubes that were used to derive the 2006 Groeneveld CHF lookup table. This compilation is based on 62 data sets that have been obtained during the past 60 years. This NUREG report describes the pertinent experimental details and possible concerns for these data sets. It also discusses the applicability and validity of the CHF lookup table to reactor conditions of interest and includes a graphical comparison of the ranges of conditions covered by these primary data and subsequently obtained supplementary data sets.
v FOREWORD The history of critical heat flux (CHF) is the history of its experimental data. There are few collections of those data from as wide a range of experiments as those given in the Groeneveld lookup tables, and there are likely few individuals who have had as much history as Dr.
Groeneveld himself. The U.S. Nuclear Regulatory Commission (NRC) created this NUREG report for two purposes:
- 1) to define and capture the all-important data that comprise the Groeneveld lookup table, including detailed data from over 60 data sets that span over 65 years of data collection
- 2) to include many of Dr. Groenevelds personal insights into the history, current state, and future of CHF predictioninformation that does not appear in any textbook or journal article and is often known only by those who have tremendous experience in the field I am grateful to the NRC and particularly to Andrew Ireland and the Office of Research for supporting this work and to Dr. Groeneveld for being willing to create it. It not only provides key information on very important data but also fills in much of the undocumented history of CHF.
Joshua S. Kaizer, Ph.D.
Reactor Engineer Nuclear Reactor Regulation
vii TABLE OF CONTENTS ABSTRACT................................................................................................................... iii FOREWORD................................................................................................................... v LIST OF FIGURES......................................................................................................... ix LIST OF TABLES.......................................................................................................... ix 1 INTRODUCTION........................................................................................................ 1 2 CRITICAL HEAT FLUX MEASUREMENTS AND UNCERTAINTIES........................ 3 2.1 Early Flow Boiling Testing............................................................................................... 3 2.2 Critical Heat Flux Detection Methods............................................................................... 3 2.3 Uncertainties in Critical Heat Flux.................................................................................... 4 2.4 Critical Heat Flux Reproducibility..................................................................................... 5 3 EVOLUTION OF CRITICAL HEAT FLUX PREDICTION METHODS........................ 7 3.1 Empirical Critical Heat Flux Correlations.......................................................................... 7 3.2 Analytical Critical Heat Flux Models................................................................................. 7 3.3 Critical Heat Flux Lookup Table Methods........................................................................ 8 4 DATABASE FOR THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE................ 11 4.1 Critical Heat Flux Data Compilations............................................................................. 11 4.2 Electronic Database of Data Used To Derive the 2006 Critical Heat Flux Lookup Table............................................................................................................................. 11 4.3 Description of the Experimental Data Sets.................................................................... 20 5 DERIVATION OF THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE................. 21 5.1 Critical Heat Flux Data Selection Criteria....................................................................... 21 5.2 Derivation of the Skeleton Table.................................................................................... 21 5.3 Derivation of the 2006 Critical Heat Flux Lookup Table................................................. 22 6 DISCUSSION............................................................................................................ 25 6.1 Critical Heat Flux Data Coverage.................................................................................. 25 6.2 Reliability of the Critical Heat Flux Lookup Table Entries............................................... 28 6.3 Additional Data Sets Not Used To Derive the 2006 Critical Heat Flux Lookup Table............................................................................................................................. 28 6.4 Application to Geometries Other Than Upflow in 8-Millimeter Tubes............................. 28 7 CONCLUSIONS AND FINAL REMARKS................................................................ 31 8 REFERENCES......................................................................................................... 33
viii APPENDIX A
SUMMARY
DESCRIPTIONS OF CRITICAL HEAT FLUX EXPERIMENTAL DATA USED TO DERIVE THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE........................................... 39 APPENDIX B REFERENCES TO CRITICAL HEAT FLUX DATA SETS FOR WATER-COOLED TUBES................................................................... 79 APPENDIX C COMPLETE 2006 CRITICAL HEAT FLUX LOOKUP TABLE............. 95
ix LIST OF FIGURES Figure 6-1 CHF Data Coverage on an L/D Versus D Map...................................................26 Figure 6-2 CHF Data Coverage on a Mass Flux Versus Pressure Map...............................26 Figure 6-3 CHF Data Coverage on a Quality Versus Pressure Map....................................27 Figure 6-4 CHF Data Coverage on a Quality Versus Mass Flux Map..................................27 Figure A-1 Test-Section Details In Lowdermilk Et al. (1958)................................................66 LIST OF TABLES Table 4-1 Sample Page From The CHF Database (CD Spreadsheet CHF Data for 2006 LUT.xls)................................................................................................... 12 Table 4-3 Ranges of Conditions of Processed CHF Data Sets.......................................... 13
1 1 INTRODUCTION Various prediction methods for the critical heat flux (CHF) have been proposed during the past 70 years. The earliest prediction methods were primarily empirical. These crude empirical correlations lacked any physical basis and had a limited range of application. Subsequently, a large number of phenomenological equations or physical models for CHF were developed; many of these models were subsequently used in reactor safety analysis codes. Physical models and phenomenological equations, however, depend on the mechanisms controlling the CHF, which changes with flow regime. These changes necessitate the use of a combination of different models, equations, or correlations for predicting the CHF during typical reactor scenarios. Because of this and because of the proliferation of CHF equations and correlations (over 500 CHF correlations are currently available for water-cooled tubes only), a more universal CHF prediction methodology was required. Hence, lookup tables (LUTs) for predicting the CHF in water-cooled tubes were subsequently derived.
The CHF LUT can be thought of as a normalized CHF databank. Compared to other available prediction methods, the LUT approach has the following advantages:
The approach has greater accuracy.
It has a wider range of applicability.
It can predict the correct asymptotic trend(s).
It requires less computing time.
It can be updated if additional data become available.
Although LUTs were initially developed for tubes and have been successfully used in subchannel codes, the greatest potential for their application is in predicting the consequences of postulated loss-of-coolant accidents. Applying the LUTs to transient heat transfer in bundles requires the use of adjustment factors to correct for geometry, flux shape, and possibly transient effects. Here the advantages of the LUT technique (wide range of application, greater accuracy, and more efficiency in computing) are particularly important to the user.
Section 2 of this report discusses the types of CHF experiments and CHF detection methods used during the past 70 years and various factors that could affect the uncertainty in the CHF measurements. Section 3 provides the background to CHF prediction methods in general and CHF LUTs specifically, while Section 4 describes the database for the 2006 CHF LUT and explains how the CHF data were obtained. Section 5 describes the methodology for deriving the CHF LUT.
Section 6 discusses the database coverage of the present and expanded database (data identified subsequent to the 2006 CHF LUT derivation) and describes some limitations in the CHF LUT and possible future improvements.
3 2 CRITICAL HEAT FLUX MEASUREMENTS AND UNCERTAINTIES 2.1 Early Flow Boiling Testing Before the advent of nuclear reactors, the need for CHF measurements was not urgent because most boiling processes in which CHF was encountered were temperature controlled (e.g., heat exchanger tubes in fossil-fueled boilers). However, water-cooled nuclear reactors, which are limited in power by the CHF occurrence, are basically heat-flux-controlled systems. Hence, exceeding the CHF can have serious consequences, particularly for pressurized-water reactors.
For this reason, most of the countries with an interest in nuclear energy became active in CHF measurements by the mid-1900s. In the United States, McAdams et al. (1949) and Jens and Lottes (1951) reported early flow boiling CHF measurements in simple geometries, such as electrically heated tubes, annuli, or rectangular channels (see also the early review of CHF studies by DeBortoli (1958)). CHF experimentation expanded greatly in the 1960s and 1970s in parallel with the worldwide construction of water-cooled nuclear reactors.
2.2 Critical Heat Flux Detection Methods CHF is typically characterized by a noticeable increase in surface temperature in response to a small change in heat flux. This change in temperature can be very drastic (for example, under pressurized-water reactor conditions referred to as fast dryout (Groeneveld, 1986)), or this change can be gradual (for example, under boiling-water reactor conditions, referred to as slow dryout). Over the past 70 years, CHF experimenters have used many different CHF detection methods. The sections below summarize the four main methods.
Visual Early CHF papers identified the CHF as the heat flux at which the test section started to redden visually. Some early researchers (e.g., Hood and Isakoff, 1962) used this method. Although this method could work well for so-called fast dryouts or departure from nucleate boiling (DNB) at subcooled CHF conditions, the slow dryouts, which are typical under boiling-water reactor conditions, would result in only modest temperature excursions that do not result in a discoloration of the heated surface.
Physical Burnout At high flows and high subcoolings, the CHF is typically very high, making it difficult to switch off the power at CHF before failure of the test section. Several investigators have reported that their CHF corresponded frequently to a physical burnout at the CHF occurrence (e.g., Hood and Isakoff, 1962; Pabisz and Bergles, 1996).
4 Change in Test-Section Resistance The test-section material used in most CHF experiments is either Inconel or stainless steel.
Inconel has a very low-temperature coefficient of resistance compared to stainless steel, which has a much higher value. The use of a stainless steel test section as one leg of a Wheatstone bridge allows detection of a CHF when the change in test-section resistance caused by a significant temperature excursion results in an imbalance in the Wheatstone bridge, triggering a power supply trip. Dell et al. (1969), Matzner et al. (1965), Hewitt et al. (1965), and others reported this CHF detection method.
Test-Section Thermocouples The most common method for detecting CHF is the use of thermocouples attached to the downstream end of the heated length of the test section. This method is most effective for most types of CHF occurrences except for very fast temperature excursions, in which a method based on detecting a change in test-section resistance may be more effective. For very slow dryouts, this method may not always be reliable because of the absence of a noticeable dryout temperature excursion. Here, a more reliable method is based on monitoring the change in the slope of Tw/q (Groeneveld, 1986).
In some cases, the CHF was actually a byproduct of a film boiling experiment in which detailed wall temperature distributions were measured; for any given heat flux, the CHF quality was either assumed to be the quality where the first rise in surface temperature was detected, or the CHF quality was defined as the average of the last pre-CHF quality and the (subsequent) first post-CHF quality. Examples of this type of CHF measurement are Era et al. (1966), Bennett et al. (1967), and Herkenrath et al. (1967); the latter two sources refer to CHF validation data sets.
2.3 Uncertainties in Critical Heat Flux CHF is primarily a function of flow conditions and test-section geometry. Because the LUT is based only on CHF measurements obtained in a tubular geometry, this section does not discuss how noncircular geometries affect CHF. In CHF experiments, the CHF is a function of the following primary parameters: (1) pressure (either at the start of the heated length or at the CHF location), (2) inlet temperature, (3) mass flow, (4) diameter, and (5) heated length. Several experimenters (e.g., Lee and Obertelli, 1963; Lee, 1965) have shown that the primary parameters, heated length and inlet temperature, can be replaced by thermodynamic quality at the CHF location as long as the heated length is sufficiently long (e.g., the length-to-diameter (L/D) ratio is greater than 50) to remove any upstream history effects. Thus, for a given inside diameter, CHF becomes a function of the flow conditions at CHF (i.e., mass flux, pressure, and thermodynamic qualitythe three parameters of the CHF LUT).
The following secondary parameters could affect the CHF:
Test-Section Orientation. Although most CHF tests have been performed for upward flow in vertical test sections, some investigators have investigated the CHF behavior in horizontal flow and downflow (e.g., Wong et al., 1990). Based on an extensive analysis of CHF in horizontal tubes, Wong et al. (1990) has shown that the effects of a horizontal test-section orientation are not significant at high flow where flow stratification occurrence is suppressed.
The boundaries of flow stratification can be estimated from flow regime maps, such as those proposed by Taitel and Dukler (1975).
5 Test-Section Material. Test-section material, in general, has little effect on CHF during flow boiling. However, for low flows and conditions where CHF is the result of DNB, high-conducting test-section materials could suppress the occurrence of hot spots under bubbles and thus increase the CHF.
Type of Heating. Most CHF experiments are performed on directly heated tubes (Joule heating), whereas the most typical application is indirect heating of a fuel sheath for which the heat source is nuclear heat. Leung et al. (1982) compared experimentally the CHF for direct and indirect heating and observed no significant effect.
Wall Thickness. Several experimenters (e.g., Bergles, 1963; Bennett et al., 1965) investigated the wall thickness effect of CHF but found no discernible effect. Some effect could possibly be present for very thin walls that could limit the heat of hotspots during a DNB-type CHF.
Surface Roughness. Most test sections had a very smooth surface finish (similar to a fuel sheath), and the impact of the very small surface roughness was not found to be significant.
Even for cases with a machined surface roughness, the impact of roughness on CHF is generally small because the vapor generation rate at the surface usually determines the CHF occurrence. However, when the surface roughness becomes larger than the film thickness (in annular film dryout), premature film breakdown could reduce CHF.
Inlet/Outlet Throttling. The majority of CHF experiments considered the flow free from fluctuations; however, restricting the flow at the outlet could cause an instability in flow and pressure and, therefore, could significantly reduce CHF, as observed by Lowdermilk (1958) and Mayinger et al. (1966). Kirillov (1997) also observed flow oscillations with a soft inlet (no throttling) as opposed to a hard inlet (with throttling) that generally suppressed the occurrence of flow oscillations.
Dissolved Gas Content in the Coolant. Most CHF experiments used degassed water; however, some experiments have purposely used dissolved gas in the coolant to examine its effect on boiling heat transfer. Kirillov (1997) reported on Russian experiments in which reductions of up to 30 percent in CHF were observed for dissolved gas content of 4,000 normal cubic centimeters per kilogram.
2.4 Critical Heat Flux Reproducibility In the late 1960s and 1970s, the concern was raised in Europe that significant differences in CHF could exist between measurements obtained at different heat transfer laboratories on nominally the same test section and for the same flow conditions. Therefore, two independent reproducibility exercises were performed, one in Western Europe in 1970 and one reported in the Union of Soviet Socialist Republics (U.S.S.R.) literature in 1984/1985. The objective of these reproducibility studies was to determine the variation in CHF measurements between various laboratories. About 8-10 laboratories participated in each of these two reproducibility studies. The sections titled, CISE (1970)/Nilsson (1970) European CHF Reproducibility Exercise, and Kirillov (1984, 1985) CHF Reproducibility Study, in Appendix I summarize these two reproducibility studies. In general, the agreement between the various European laboratories was within 10 percent except for two outliers that were later disqualified.
7 3 EVOLUTION OF CRITICAL HEAT FLUX PREDICTION METHODS 3.1 Empirical Critical Heat Flux Correlations CHF prediction methods for flow boiling were reported as early as 1949 (McAdams, 1949). The interest in CHF initially grew slowly but expanded rapidly in the early 1960s as an improved knowledge of CHF was urgently needed to determine the power limits for the many reactors then under construction around the world. A book by Tong (1965) (the first book that covered flow boiling CHF) reviewed several of the early CHF prediction methods, most of which were purely empirical. In parallel, Clerici (1966) published a list of over 50 CHF correlations for water-cooled tubes. Since then, the number of published CHF correlations for water-cooled tubes has increased to well over 500. In contrast to pool boiling for which the early prediction methods are still in use, none of the early flow boiling CHF correlations for tubes carry much credibility today, partially because the pool boiling CHF equations had a physical basis, whereas the tube CHF correlations were virtually all empirical.
Most of the tube CHF correlations have essentially the form = (,,, ) or are in a dimensionless form
= (
0.5
()
0.5,,
), although other dimensionless parameters may have been used as well. The choice of correlation parameters (,,, ) is essentially correct, but the functional relationship between these parameters varies with flow conditionshence, the large proliferation of correlations. The CHF equations of Katto (1992) and Lee and Mudawar (1988) deserve special mention because they (1) have a phenomenological basis, (2) are based on a large database, and (3) appear to have a wider range of validity.
3.2 Analytical Critical Heat Flux Models The lack of a satisfactory CHF prediction technique using empirical correlations led to the development of analytical CHF models, starting in the late 1960s. These models, which were based on the physical mechanisms and satisfy the conservation equations, can be divided into two main groups:
- 1) Annular Film Dryout Models. These models are based on a mass balance on the liquid film in annular flow and postulate that CHF corresponds to the depletion of the liquid film.
Hewitt and co-workers (Hewitt and Hall-Taylor, 1970; Bennett et al., 1967) developed the original annular film dryout models in the 1960s. The models differ in the equations for droplet entrainment and deposition and interfacial friction and heat transfer. These models provide reasonable predictions of CHF for the annular flow at medium to high pressures and flows and void fractions exceeding 50 percent (Hewitt and Hall-Taylor, 1970).
- 2) Bubbly Layer Models. These models postulate that CHF occurs in the lower quality regime when the bubble layer covering the heated surface becomes so thick and saturated with bubbles that no liquid mixing between the near-wall layer and the cooler core liquid is possible. Tong (1965, 1968) and Tong and Hewitt (1972) proposed early versions of this model. This model and subsequent variations proposed by Weisman and Pei (1983) and Ying and Weisman (1986) appear to predict the CHF with reasonable accuracy under high-pressure, high-flow, and low-quality or subcooled conditions.
8 Although the analytical models have improved significantly and usually predict the correct asymptotic trends after suitable fine tuning, the evaluation process is complex and time consuming. In the 1970s and 1980s, developing CHF models was a popular academic pursuit and resulted in the more than 50 CHF models now available, each based on different assumptions of interfacial relationships. CHF models tend to be less accurate than empirical correlations over the range of the correlations database. Weisman (1992) presented an excellent review of the analytical CHF models.
3.3 Critical Heat Flux Lookup Table Methods Because of the proliferation in CHF correlations and models and the limited range of application of the models and correlations, the need for a more generalized CHF prediction technique is obvious. As a basis of the generalized technique, the common local conditions hypothesis was used (i.e., the assumption was that the CHF for a water-cooled tube and a fixed tube diameter is a unique function of local pressure (P), mass flux (G), and thermodynamic quality (X)). Doroshchuk et al. (1975) made an initial attempt to construct a standard table of CHF values for a given geometry using a limited database of 5,000 data points for water-cooled tubes. This table and all subsequent tables contain normalized CHF values for a vertical 8-millimeter (mm) water-cooled tube for various pressures, mass fluxes, and qualities. The Center for Nuclear Studies in Grenoble (France), the University of Ottawa (Canada), the Institute of Physics and Power Engineering (IPPE) (U.S.S.R.), and Atomic Energy of Canada Limited (AECL) (Canada) subsequently improved and expanded the CHF LUT using an ever-increasing CHF database.
In 1986, Groeneveld et al. published the AECL-UO table, which covers a much wider range of conditions than Doroshchuks table. The databank on which the 1986 LUT was based contained 15,442 CHF data points taken from 12 separate data sets and the two data compilations of Thompson and MacBeth (1964) and Zenkevich (1974). Kirillov et al. (1989a, 1989b, 1991a, 1991b) improved the CHF table of Doroshchuk et al. by introducing a larger database, but the range of applications covered in their tables remained smaller than that of the AECL-UO table. Groeneveld and Kirillov used different databases and methodologies to derive their respective tables. A subsequent data exchange agreement between Groeneveld and Kirillov resulted in a combined CHF databank of more than 30,000 tube CHF data points (24,000 data points after removing duplicates), which was used to derive the 1995 CHF LUT.
The 1995 CHF LUT has a wider range of validity and presents normalized CHF values for 21 pressures, 20 mass fluxes, and 23 critical qualities covering, respectively, ranges of 0.1 to 20 megapascals (MPa), 0 to 8 megagrams per square meter per second (zero flow refers to pool-boiling conditions), and -50 to 100 percent (negative qualities refer to subcooled conditions). The 1995 LUT also removed the sharp variations in CHF that were present at some of the boundaries between regions where experimental data were available and regions where correlations and extrapolations were used. A smoothing procedure developed by Huang and Cheng (1994), as described in Section 5.3, was used to suppress these sharp variations.
Between 1995 and 2006, 27 additional CHF data sets for vertical tubes with upward water flow that were not used for the development of the 1996 CHF LUT were acquired. Further enhancements were made to the CHF LUT and its database by AECL and the University of Ottawa, culminating in the 2006 CHF LUT as described in the Nuclear Engineering and Design article by Groeneveld et al. (2007) titled, The 2006 CHF Look-Up Table. Appendix II-1 lists the CHF data sets used for developing the 2006 CHF LUT. Note that the space requirements of the
9 Nuclear Engineering and Design journal did not permit the inclusion of the complete CHF LUT; instead, the journal article presented a somewhat condensed version. Appendix III presents the complete CHF LUT.
The most recent CHF LUT method (Groeneveld et al., 2007) provides CHF values for water-cooled tubes at discrete values of pressure (P), mass flux (G), and thermodynamic quality (X), covering respectively the ranges of 0.1 to 20 MPa, 0 to 7,500 kilograms per square meter per second (kg m-2 s-1) (zero flow refers to pool-boiling conditions), and -50 to 100 percent (negative qualities refer to subcooled conditions). Linear interpolation between table values is used for determining CHF at in-between table conditions. Extrapolation is usually not necessary because the table covers a very wide range of conditions. Compared to other available prediction methods, the tabular approach has the following advantages:
The approach has greater accuracy.
It has a wider range of applicability.
It can predict the correct asymptotic trend(s).
It requires less computing time.
It can be easily updated if additional data become available.
Section 5.0 summarizes the derivation of the LUT. Since the derivation of the 2006 CHF LUT, additional data sets have become available. Sections II-2 and II-3 of Appendix II provide references to these additional data sets. These additional data sets can be used to update the CHF LUT or to independently validate the CHF LUT.
11 4 DATABASE FOR THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE 4.1 Critical Heat Flux Data Compilations DeBortoli (as reported by Firstenberg et al. (1960)) created the first CHF data compilation for tube data. Subsequently, many CHF data compilations have been assembled, either for tube CHF data or for tube and more complex geometries (e.g., annuli or bundles). Seventeen CHF data compilations for tubes were identified; Section II-4 of Appendix II includes references to these data sets.
Many of these compilations give sources for the CHF data used to derive the CHF LUTs. To eliminate possible errors in transcribing data, we always attempted to locate the original source of the data instead of relying on the (sometimes questionable) accuracy of the CHF compilations done by others.
Two of the compilations (European Reproducibility Study 1970 and U.S.S.R. Reproducibility Study 1984) represent the results of two separate CHF reproducibility studies. Eight to 10 laboratories participated in each of these two reproducibility studies. The Appendix I sections titled, Kirillov (1984, 1985) CHF Reproducibility Study, and CISE (1970)/Nilsson (1970)
European CHF Reproducibility Exercise, summarize these two reproducibility studies.
4.2 Electronic Database of Data Used To Derive the 2006 Critical Heat Flux Lookup Table The 25,000 experimental data points used to derive the 2016 CHF LUT were tabulated in an electronic database (Compact Disc (CD) Spreadsheet CHF Data for 2006 LUT.xls). The first page of this database (Table 4-1) provides an overview of the flow parameters for each CHF point. Section 4.3 summarizes each data set.
Table 4-2 summarizes the range of conditions of each processed CHF data set and includes supplementary data that have been processed subsequent to the 2006 CHF LUT derivation with the data set name presented in italics. Section II-2 of Appendix II provides the references to these data sets. In addition, Section II-3 of Appendix II contains references to additional data sets that have not yet been processed.
12 Table 4-1 Sample Page from the CHF Database (CD Spreadsheet CHF Data for 2006 LUT.xls)
Data D
L P
G Xchf DHin CHF Tin Reference m
m kPa kg m-2s-1 kJ/kg kW m-2
°C 25 0.004 0.396 100 77.5 0.84 317 442 23.94 Lowdermilk, 1958 26 0.004 0.396 100 142.7 0.79 317 757 23.94 Lowdermilk, 1958 27 0.004 0.396 100 203.9 0.7 317 978 23.94 Lowdermilk, 1958 28 0.004 0.396 100 271.8 0.73 317 1,325 23.94 Lowdermilk, 1958 29 0.004 0.396 100 421.3 0.62 317 1,798 23.94 Lowdermilk, 1958 30 0.004 0.396 100 543.6 0.58 317 2,239 23.94 Lowdermilk, 1958 31 0.004 0.396 100 679.5 0.55 317 2,712 23.94 Lowdermilk, 1958 32 0.004 0.396 100 978.5 0.5 317 3,564 23.94 Lowdermilk, 1958 33 0.004 0.396 100 1,372.7 0.45 317 4,573 23.94 Lowdermilk, 1958 34 0.004 0.396 100 1,644.5 0.42 317 5,236 23.94 Lowdermilk, 1958 35 0.004 0.594 100 77.5 0.88 324 300 22.27 Lowdermilk, 1958 36 0.004 0.594 100 135.9 0.81 324 505 22.27 Lowdermilk, 1958 37 0.004 0.594 100 203.9 0.75 324 694 22.27 Lowdermilk, 1958 38 0.004 0.594 100 258.2 0.71 331 852 20.6 Lowdermilk, 1958 39 0.004 0.594 100 407.7 0.63 331 1,199 20.6 Lowdermilk, 1958 40 0.004 0.594 100 543.6 0.6 331 1,514 20.6 Lowdermilk, 1958 41 0.004 0.594 100 693.1 0.58 331 1,892 20.6 Lowdermilk, 1958 42 0.004 0.594 100 992.1 0.56 331 2,618 20.6 Lowdermilk, 1958 43 0.004 0.792 100 78.8 0.74 331 196 20.6 Lowdermilk, 1958 44 0.004 0.792 100 135.9 0.76 331 347 20.6 Lowdermilk, 1958 45 0.004 0.792 100 217.5 0.72 331 536 20.6 Lowdermilk, 1958
13 Table 4-2 Ranges of Conditions of Processed CHF Data Sets Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Alekseev (1964) data from Kirillov (1992) 70 10.00 10.01 1.000 4.966 9,800 19,610 216 7,566
-0.866 0.944 57 1,398 134 4,949 139.77 357.93 Alessandrini et al.
(1963) 753 15.2 24.9 0.80 2.46 4,795 5,148 1,080 4,140
-0.04 0.75
-1,110 365 206 3,689 185 265 Babarin et al.
(1969) 163 12.0 0.96 1.80 284 310 50 500 0.466 1.091 37.6 495 190 2,300 15 124 Babcock and Hood (1962) 39 8.00 22.5 0.61 413 6,890 2,946 11,452
-0.187
-0.05 202 639 4,876 10,546 19 177 Baek (2001) 56 6.00 10.0 0.18 0.40 101 3,618 497 2,032
-0.091 0.099 254 935 2,041 7,413 5.9 40.2 Bailey (1977) 110 15.0 3.77 5.37 1,350 7,080 49 1,383 0.45 0.99
-178 473 84 1,134 93 286 Bailey and Lee (1969) 158 9.30 3.05 6,895 18,340 958 4,242 0.069 0.727 54 604 344 2,221 199 347 Becker et al.
(1963)
AE-114 2,659 3.94 20.10 0.100 3.750 216 8,973 100 3,183
-0.069 1.054
-50 1,640 278 7,477 25.42 Becker (1965)
AE-RTL-778 1,326 3.93 37.47 0.216 3.750 1,128 9,905 159.5 5,586
-0.005 0.993
-16 2,711 503 6,620 63.32 288.71 Becker (1970)
TPM-RL-1260 116 2.40 36.03 0.500 1.880 3,050 7,100 93.3 2,725 0.207 0.903 371 1,065 1,026 5,130 51.75 113.22 Becker et al.
(1971)
KTH-NEL-14 1,455 10.00 10.01 1.000 4.966 3,000 20,000 156 8,111
-0.866 1.061 26 1,414 135 5,476 124.75 358.65
14 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Bennett et al.
(1965)
AERE-R 5055 201 9.22 12.62 1.524 5.563 6,612 7,481 623.8 5,844.4 0.026 0.948 21 691 589.6 3,299.7 157.67 279.45 Bergelson (1980) data from Kirillov (1992) 328 8.00 0.241 0.400 170 3,080 1,927 7,078
-0.295 0.090 96 853 3,511 14,571 28.94 169.20 Bergles (1963)
ASME 63-WA-182 117 0.62 6.21 0.011 0.155 140 586 1,518.7 24,272.4
-0.137 0.111 25 534 4,957.1 44,713 3.10 116.55 Bertoletti et al.
(1964) 386 4.90 15.20 0.050 2.675 4,881 9,876 1,051 3,948.8
-0.083 0.774
-28 769 198.7 7,502.8 112.97 302.14 Biancone et al.
(1965) 245 10.2 17.1 0.78 1.32 7,914 14,396 465 3,167
-0.25 0.662 45 1,355 742 6,649 48 326 Borodin and Macdonald (1983)
CRNL-2538 Restricted distribution Burck and Hufschmidt (1965) 143 10.0 0.35 1,100 3,090 917 3,756
-0.246 0.087 532 939 4,500 12,200 16.7 60.8 Campolunghi (1973) 218 12.0 15.6 20.5 254 9,660 1,111 2,545 0.296 0.772 19.6 740 155 479 205 260 Celata et al.
(1992a) set 1 60 6.00 8.00 0.10 0.15 398 5,120 2,019 10,046
-0.517
-0.106 350 1,018 7,428 29,514 29 81 Celata et al.
(1992b) set 2 78 2.50 5.00 0.20 0.40 107 2,181 2,166 32,637
-0.091 0.287 345 790 5,347 42,777 19 55 Celata and Mariani (1993) 88 0.10 22.50 0.002 0.610 90 6,890 917 90,000 0.007 0.923 88 1,023 4,000 228,000 3.44 245.78
15 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Celata et al.
(1993) 78 2.50 0.10 578 2,714 11,240 40,000
-0.357
-0.104 387 844 12,113 60,579 30 70.5 Cheng et al.
(1983a) 150 12.60 0.370 0.740 101 687 50 400 0.187 1.227 42 210 331.2 2,115 70.00 154.61 Cheng et al.
(1983b) 132 4.80 0.19 0.38 100 700 300 750 0.082 0.765 42 214 889 2,131 49.6 145 Dell et al. (1969)
AERE-M 2216 82 6.17 0.914 5.512 6,895 14,328.9 4,135.8 0.144 0.779 79 365 492.7 3,340.4 217.13 270.09 Doerffer (1999)
Proprietary data Doerffer et al.
(1997)
Proprietary data Era et al. (1966) 163 5.98 1.602 4.800 6,777 7,049 1,105 3,014.9 0.374 0.952
-1,211 565 109.2 1,960.9 181.13 509.30 Griffel (1965)
NYO-187-7 397 6.22 37.46 0.610 1.972 3,448 10,343 637.3 18,577.2
-0.209 0.592 45 1,209 1,400.6 8,107.3 87.68 287.07 Groeneveld (1985)
Proprietary data Hassid et al.
(1967)
CISE-R-236 191 24.90 25.10 1.590 2.391 2,942 6,090 369.3 3,857.5
-0.035 0.838 1,427 3,433 1,430.9 3,444.1 153.89 267.66 Hewitt et al.
(1965)
AERE-R 4864.
442 9.30 0.229 3.048 101 208 90.9 301 0.160 1.083
-41 383 144 4,013 13.71 119.39 Hood (1962) 61 6.30 25.4 0.61 414 8,412 2,156 11,390
-0.25
-0.05 204 1,113 5,741 11,830
-20 243
16 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Hood and Isakoff (1962) 24 8.00 22.2 0.60 1.10 6,895 664 2,726 0.001 0.484 66 1,224 3,186 4,637 7.5 272 Inasaka et al.
(1991) 8 6.00 0.10 104 114 6,520 11,364
-0.09
-0.07 250 266 7,280 11,200 39 41 Inasaka and Nariai (1989) 29 3.00 0.10 290 1,050 4,300 29,900
-0.188
-0.051 266 626 7,300 44,500 25 78 Jafri (1993) 49 15.8 2.44 317 1,060 1,439 8,102
-0.021 0.28 223 667 1,795 5,691 19 129 Jens and Lottes (1951)
Subcooling CHF data 48 5.74 0.625 3,448 13,790 1,301.8 10,603.9
-0.464
-0.015 279 1,310 2,965.3 11,924.4 70.52 285.05 Judd and Wilson (1966)
BAW-3238-9 49 11.30 1.829 6,861 13,859 673.9 3,428 0.016 0.776 33 730 593.1 2,668.8 207.11 323.84 Kim et al. (2000) 502 6.00 12.0 0.30 1.77 104 951 21 277 0.397 1.251 0.8 634 130 1,598 20 156 Kirillov et al.
(1984) 2,470 7.71 8.09 0.990 6.000 6,370 18,040 494 4,154
-0.494 0.981 7
1,537 110 7,700 79.41 350.90 Kureta (1997) 913 1.00 6.00 0.04 0.68 101.3 4.1 19,130
-0.147 1.664 0
391 185 158,100 6.7 100 Ladislau (1978)
(see Kirillov database (1992))
136 4.00 0.200 420 1,000 884 5,504
-0.051
-0.009 104 638 1,860 4,631 28.04 149.56 Lee (1965) 38 9.50 1.73 3.05 6,828 7,024 2,020 5,720 0.002 0.433 75.5 577 1,307 3,873 161 271
17 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Lee (1966)
AEEW-R479 435 14.10 44.70 0.635 1.524 8,237 12,579 332.2 3,410.3
-0.110 0.780 60 451 870.7 3,738.2 259.80 318.09 Leung et al.
(1989) 66 5.45 2.511 5,030 9,710 1,167.6 9,938.3 0.210 0.578 6
316 656.2 3,058.3 227.85 305.33 Leung et al.
(1990)
Restricted distribution Lowdermilk et al.
(1958) 470 4.00 4.80 0.119 0.991 100 27.2 4,865.5 0.030 1.236 317 331 167 9,525 20.91 24.24 Matzner et al.
(1965) 99 10.20 2.438 4.877 6,893 1,193.3 9,559.8 0.008 0.693 48 1,183 643.5 4,041 65.61 275.82 Mayinger et al.
(1966) 128 7.00 0.560 0.980 1,925 10,244 2,233 3,734 0.098 0.405
-239 314 924 5,618 233.28 310.09 Mudawar and Bowers (1999) 174 0.40 2.50 0.004 0.031 250 17,240 5,000 134,000
-1.778
-0.062 254 1,579 9,400 276,000 18 70 Nariai et al.
(1987) 93 1.00 3.00 0.009 0.101 100 6,710 20,910
-0.134 0.007 149.5 353 4647 69,990 15.4 64 Nariai et al.
(1991) 7 6.00 0.10 196 1,470 7,700 9,952
-0.24
-0.096 306 618 12,110 17,230 33 53 Nariai CHF data set from Celata (2001) 14 6.0 0.100 100 1,500 4,590 8,690
-0.2595 0.0577 31 281 8,500 22,100 38.3 44.7 Nguyen and Yin (1975) 56 12.60 2.438 4.877 6,645 8,401 929.6 3,838.4 0.216 0.738 52 413 677 2,023.7 225.06 276.81 Olekhnovitch (1997) 479 8.00 0.75 3.50 507 4,036 977 6,122 0.046 0.761 4
498 523 5,550 47 244
18 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Ornatskii (1963) 69 2.00 0.04 17,732 20,265 5,000 30,000
-2.41
-0.054 175 1,811 5,579 70,314
-21 335 Ornatskii and Kichigin (1961) 222 2.00 0.04 1,013 7,599 5,000 30,000
-0.654
-0.002 72 1,176 6,392 70,895 2.25 263.8 Ornatskii and Kichigin (1962) 169 2.00 0.04 7,599 15,199 5000 30000
-1.23
-0.026 79 1,566 8,136 72,058 0.88 331 Ornatskii and Viniarskii (1965) 109 0.50 0.014 1,013 7,194 20,000 90,000
-0.572
-0.107 321 1,942 39,542 224,459
-20 195 Pabisz and Bergles (1996) 10 4.40 6.20 0.11 0.154 627 1,284 2,417 4,994
-0.196
-0.133 567 698 7,370 13,880 15.3 46 Peterlongo et al.
(1964) 349 15.1 15.2 1.62 4.02 4933 6,551 1,010 4,020
-0.02 0.608
-90 1,038 895 4,115 27 281 Ruan (1994) 41 9.00 0.40 106 707 12 207 0.469 0.966 15 279 139.4 1,955 40 153 Rudzinski (1999)
MR1-A Data (Private Communication)
Restricted distribution Shan (2005) 24 8.00 1.00 13,337 14,808 572 4,137
-0.022 0.422 97 692 819.5 4,511 198 328 Shlykov et al.
(1970) 60 3.60 0.10 76.5 386 12,865 25,494
-0.167
-0.022 149 508 12,800 30,300 3
98 Smolin et al.
(1962) 369 3.84 10.80 0.776 4.000 7,840 19,610 498 7,556
-0.132 0.795 5
1,329 230 5,652 140.35 350.39
19 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Smolin et al.
(1979) data from Kirillov (1992) 2,987 3.84 16.00 0.690 6.050 2,940 17,710 490 7,672
-0.136 0.789 4
1,362 245 5,626 72.72 351.65 Snoek (1988)
(CRNL-4231)
Proprietary data Soderquist (1994) 1,463 8.00 8.10 1.00 6.00 970 20,120 243 6,086
-0.169 1.336 35 693 94 3,879 112 355 Stein (2004) 383 9.00 0.13 0.45 1,090 7,140 24 304.5
-0.002 1
215 1,245 237.5 4,700.5 134 272 Swenson et al.
(1962) 25 10.4 10.5 1.75 1.80 13,790 679 1,765 0.178 0.502 44 564 587 1,063 231 329 Tain (1994) 55 8.00 1.75 6,849 10,127 2,401 7,832 0.028 0.378 27 455 1,341 4,358 191 299 Tong (1964) 266 6.22 12.90 0.380 3.660 5,171 13,790 678 14,002 0.002 0.502 5
1,060 587 6,139 263.94 330.85 Vandervort (1992) 210 0.30 2.70 0.002 0.066 131 2,277 8,438 41,810
-0.276
-0.018 169 759 18,700 123,800 6.4 85 Waters et al.
(1965) 37 11.2 0.61 3.65 6,895 10,342 6,578 9,548
-0.033 0.322
-322 1,050 2,017 5,389 87 313 Weber and Johannsen (1990) 55 9.70 0.043 110 1,200 10.8 301 0.072 1.53 4.2 577 1,495 7,572 65 175 Whittle and Forgan (1967) 59 6.45 0.4064 0.6096 117.2 172.4 1,643.5 9,137
-0.0311
-0.0088 290 171 660 3,480 35 75
20 Source of CHF Data Number of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature Reference number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C Williams and Baus (1980) 129 9.50 1.84 2,758 15,169 324 4,663
-0.025 0.929 140 1,223 388 4,073 90 315 Yildiz (1997) 385 6.00 8.00 0.17 0.31 90 721 48.5 411 0.001 0.914
-4.26 1,057 533 4,381 31 158 Yin et al. (1988) 287 13.40 3.658 1,028 21,197 1,938.9 2,081.6 0.075 0.431 0
493 583.3 1,863.7 128.42 358.41 Zenkevich (1969) data from Kirillov (1992) 5,595 3.99 15.10 0.250 6.000 5,880 19,610 498 9,876
-1.652 0.964 2
1,644 136 14,760 76.01 361.79 Zenkevich (1971) data from Kirillov (1992) 392 7.80 8.05 7.000 20.000 6,860 17,650 1,008 2,783 0.262 0.876 18 1,549 47 1,283 81.96 352.22 Zenkevich et al.
(1974) data different from the others 823 4.80 12.60 1.000 6.000 5,890 19,620 497.2 6,694.4
-0.221 0.969 5
1,381 230 4,740 96.70 358.24 Zenkevich et al.
(1964) 63 6.8 10.0 0.10 0.39 3,924 9,810 550 6,444
-0.02 0.693 131 279 4,910 9,710 211 286 4.3 Description of the Experimental Data Sets Appendix I summarizes the pertinent experimental details of the many data sets used to derive the 2006 CHF LUT. This appendix generally specifies the method of CHF detection. If a method is not specified, CHF detection by thermocouples is the most likely method.
21 5 DERIVATION OF THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE 5.1 Critical Heat Flux Data Selection Criteria Not all CHF data points were used for the derivation of the CHF LUTs. The CHF data selection criteria used for screening the CHF database have evolved from the relatively simple check for duplicates and heat balance inconsistencies used during the 1986 CHF LUT derivation to the more sophisticated approach used in the 2006 CHF LUT derivation process. The most recent CHF data selection criteria are as follows:
acceptable values for diameter (3 < D < 25 mm), L/D ratio (L/D > 50 for Xcr > 0, L/D > 25 for Xcr < 0), pressure (100 P 21,000 kilopascal (kPa)), mass flux (0 G < 8,000 kg m-2 s-1), and quality (Xcr < 1.0) data that must satisfy the heat balance (i.e., reported power should be approximately equal to [flow]*[enthalpy rise])
identification of outliers using the slice method (Durmayaz et al., 2004)
The slice method was introduced to examine all the data behind each set of flow conditions in the LUT. For each nominal LUT pressure slice, (1+)
2
(+1+)
2 and for each nominal mass flux, (1+)
2
(+1+)
2
, a CHF versus critical quality plot was created. Data that did not obviously agree with the bulk of the data and the previous CHF LUT were labeled as outliers and were excluded in the CHF LUT derivation process. A similar slice approach was used for the CHF versus pressure (P) and CHF versus mass flux (G) plots.
identification of duplicate data using the slice method (i.e., more than one author may have reported the same data sets) removal of data sets that display a significant scatter and generally disagree with the bulk of the data These bad data sets may result from soft inlet conditions that can give rise to flow instabilities or a poorly performed experiment (e.g., large uncertainties in instrumentation).
5.2 Derivation of the Skeleton Table The derivation of the CHF LUT requires a skeleton table to provide the initial estimate of the CHF LUT values. The skeleton CHF values are used for evaluating the slopes of CHF versus P, G, or X. The slopes are used for extrapolating selected CHF measurements to the surrounding LUT values of pressure (P), mass flux (G), and thermodynamic quality (X) as described by Groeneveld et al. (1996). The skeleton table also provides the default CHF values under conditions where no experimental data are available.
22 The skeleton table is primarily based on the 1995 CHF LUT but with corrections to the subcooled region. These corrections were necessary because the skeleton table for the 1995 CHF LUT was partially based on the Katto (1992) equation, which was subsequently found to contain discontinuities or trend reversals at certain conditions.
Values in the skeleton table for G = 0 kg m-2 s-1 and X < 0 are predicted using the Zuber (1959) correlation with the correction factor derived by Ivey and Morris (1962). The skeleton table values for G > 300 kg m-2 s-1 and X < 0 are either maintained or replaced with the predicted values by the Hall and Mudawar (2000) equation, based on a visual observation of the plots produced by slicing the LUT and the data trends.
Generally, for 0 < G < 300 kg m-2 s-1 and X < 0, the skeleton table values are established using a linear interpolation between those at zero flow and 500 kg m-2 s-1 to provide a smooth transition.
Compared to the 1995 LUT, three additional pressures (2, 4, and 21 MPa) and one mass flux (750 kg m-2 s-1) were added to the 2006 LUT. The skeleton CHF values for conditions involving pressures at 2 and 4 MPa and a mass flux of 750 kg m-2 s-1 were obtained from linear interpolation. The skeleton table CHF values for 21 MPa were interpolated using the CHF versus pressure trend of the Zuber pool-boiling CHF equation, which was found to approximately agree with CHF versus pressure trends for flow boiling at very high pressures.
5.3 Derivation of the 2006 Critical Heat Flux Lookup Table The primary building blocks for the CHF LUT are the screened database and the skeleton table.
The steps described below were taken during the LUT derivation process.
The 1995 CHF LUT, which was modified as described in the previous section, was used as the skeleton table. The effect of tube diameter on CHF is accounted for by using the diameter correction factor,
=8= (
8) 0.5
, for the range of 3 < D < 25 mm. Outside this range, the diameter effect appears to be absent (Wong, 1994).
For each set of LUT conditions (each combination of Px, Gy, and Xz), all experimental data falling within the range Px-1 < Pexp < Px+1, Gy-1 < Gexp < Gy+1, and Xz-1 < Xexp < Xz+1 were selected. Each experimental CHF point was corrected for the differences in pressure (Pexp - Px), mass flux (Gexp - Gy), and quality (Xexp - Xz), using the slopes of the skeleton table and given an appropriate weight as described by Groeneveld et al. (1986, 2007). The weighted, averaged CHF value for all corrected data surrounding each table entry was used to replace the skeleton CHF value.
The updated CHF LUT is not smooth and displays an irregular variation (without any physical basis) in the three parametric ranges: pressure (P), mass flux (G), and quality (X). These fluctuations are attributed to data scatter, systematic differences between different data sets, and possible effects of second-order parameters such as heated length, surface conditions, and flow instability. Sharp variations in CHF were also observed at some of the boundaries between regions where experimental data are available and regions where correlations and extrapolations were used. Before finalizing the LUT, a smoothing procedure developed by Huang and Cheng (1994) was applied. The principle of the smoothing method is to fit three polynomials to six table entries in each parametric direction. The three polynomials intersect each other at the table entry, where the CHF value is then adjusted. This method significantly improved the smoothness of the LUT. A third-order polynomial was initially used for the
23 smoothing of the 1995 CHF LUT. However, the 2006 analysis showed that a first-order polynomial results in a smoother table with no significant loss in prediction accuracy.
Applying the smoothing process to the table entries under all conditions suppressed the discontinuity at the boundaries of the limiting quality region (LQR), as described by Groeneveld et al. (2007), resulting in a nonrepresentative trend to the experimental data. To maintain the physical trend of the table entries at the LQR, an intermediate table was created that maintained the more abrupt changes at the boundaries of the LQR, extrapolated to the nearest LUT qualities. Some smoothing was subsequently needed to avoid a fluctuation in CHF with pressure and mass flux.
25 6 DISCUSSION 6.1 Critical Heat Flux Data Coverage The tabulation of experimental CHF data is based on the primary CHF parameters (i.e., those parameters used in correlating the CHF, such as pressure (P), mass flux (G), quality at CHF (XCHF), and diameter (D). Because the quality at CHF is a calculated parameter, it is sometimes replaced with heated length (L) and inlet subcooling (Hin) or inlet temperature. Figures 6-1 through 6-4 show the primary conditions for which water CHF data were available at the time of the 2006 CHF LUT derivation. These figures show CHF data coverage on L/D versus D, mass flux (G) versus pressure (P), quality (X) versus pressure (P), and quality (X) versus mass flux (G) maps, respectively. Superimposed on this are the supplementary data taken from 27 references processed after the 2006 CHF LUT. Appendix II-2 provides the references to these data sets.1 Note that the supplementary data fill in some, but not all, gaps in the data. Despite the large database (over 40,000 data points), noticeable gaps still exist in flow conditions and geometry where CHF data are not available. The primary conditions for which data are scarce or missing include (1) high flows and high qualities, (2) low flows and low qualities, and (3) pressure ranges of 0.2 to 0.5 MPa. The reasons for the scarcity of CHF data under the above conditions are as follows:
High Flow/High Quality. Obtaining CHF data at high flows and high qualities is very difficult because it requires the use of a complex two-phase inlet setup. Additional heat balance calculations across a preheater or mixer are necessary to obtain the test-section inlet enthalpy and inlet quality. The method used to introduce the two-phase mixture into the test section can also affect the CHF. Using a very long test section would be an alternative approach, but it is complex and expensive and would result in a very large pressure drop. Note that, at low pressures and high flows, this has occasionally resulted in critical flow conditions, which provide an upper flow limit (Tain, 1995).
Low Flow/Subcooled CHF. At low pressures, negative qualities of less than -0.20 are impossible to obtain because they would result in water temperatures less than 0 degrees Celsius (C). In addition, the CHF is very high under these conditions, and this would result in a very large axial quality gradient (dX/dZ) (i.e., obtaining low-flow/low-quality CHF data would require very short test sections, whereby the entrance effects could affect the CHF). In addition, at highly subcooled conditions, the CHF can occur so fast that, in some tests, each CHF occurrence resulted in a physical test-section failure because of burnout.
Low Pressures. Experiments at low pressure, especially for higher qualities and lower flow, could cause flow instability and, therefore, could lower the CHF.
Another possible reason for the scarcity in data for some of these conditions is lack of interest since heat transfer equipment may not operate under these conditions.
1 Appendix II also contains references to additional data sets that have not yet been processed and, therefore, are not shown in Figures 6-1 through 6-4.
26 Figure 6-1 CHF Data Coverage on an L/D Versus D Map Figure 6-2 CHF Data Coverage on a Mass Flux Versus Pressure Map
27 Figure 6-3 CHF Data Coverage on a Quality Versus Pressure Map Figure 6-4 CHF Data Coverage on a Quality Versus Mass Flux Map
28 6.2 Reliability of the Critical Heat Flux Lookup Table Entries Appendix III shows the complete CHF LUT. In the condensed CHF LUT (as reported in Groeneveld et al. (2007)), four levels of shading were applied to highlight regions of uncertainty.
The uncolored entries represent areas that were derived directly from the experimental data and, hence, have the least uncertainty. The light gray regions represent calculated values based on selected prediction methods that provide reasonable predictions under neighboring conditions where experimental data are available. The uncertainty in this region depends on the level of extrapolation from data-based regions. The uncertainty is expected to be small at conditions slightly beyond the range of data, but it becomes larger as the extrapolation is further beyond this range. The medium gray regions represent conditions for which CHF values were often impossible to obtain, including (1) conditions for which critical flow may exist, (2) coolant enthalpies, where the bulk of the liquid starts to become solid (Tbulk < 0.01 degree C), and (3) G = 0, where the concept of flow quality becomes imaginary. Those regions are included only to improve interpolation accuracy of other regions. Extrapolation into the medium gray region should be avoided. Finally, the dark gray entries represent the LQR, where rapid changes in CHF versus quality curve can be observed. Note that the LQR does not occur at all pressures and mass fluxes. The shading coding can be extrapolated to the complete CHF LUT in Appendix III for conditions where no shading was shown (e.g., P = 4, 8, 9, and 11 MPa).
6.3 Additional Data Sets Not Used To Derive the 2006 Critical Heat Flux Lookup Table Besides the above data sets, the literature includes a number of additional CHF data sets for upward water flow in vertical tubes. The current CHF database does not yet include these data sets. These data sets need to be transcribed from the reports and compiled into a database.
Section II-3 of Appendix II includes references to these additional data sets.
6.4 Application to Geometries Other Than Upflow in 8-Millimeter Tubes The LUT was based solely on CHF data obtained in directly heated tubes within the diameter range of 3 to 25 mm. The CHF values measured in tubes having diameters other than 8 mm (CHFD) were normalized to an equivalent CHF value in an 8-mm tube (CHF8) using the relationship 8 = (
8)
. In the derivation of the LUT, various values of the exponent n were used; the optimum value was found to be close to n = 0.5, and this value was used for the derivation of the 2006 CHF LUT.
When applying the LUT to subcooled conditions, Tanase et al. (2009) found a slight improvement in prediction accuracy when they used a value of n = 0.33. Mishima et al. (1985, 1987) noted that, for flooding-type CHF (low-flow and low-pressure conditions), the CHF increases with an increase in diameter; therefore, they recommended a negative exponent, n = -0.2 to -0.3, for those specific conditions.
Various investigators have applied the CHF LUT to bundle geometries. When applying the LUT in a subchannel code, the common practice has been to correct the CHF LUT by using the equivalent diameter in the above equation. This practice ignores the possible effect of having a convex surface instead of a concave surface. Doerffer et al. (1994, 1997) compared the CHF in internally heated and bilateral heated annuli and concluded that the CHF on the inner rod in annuli (after correcting for the equivalent diameter effect) is lower than it is in tubes, especially
29 at higher qualities, whereas the reduction in CHF is least or nonexistent at subcooled conditions. They proposed correction factors that depend on geometry and flow conditions.
Rod-spacing devices, such as grids or endplates and spacers in Canadian deuterium uranium (CANDU) reactors, are known to enhance CHF. The spacer effect decays exponentially downstream from the rod-spacing device according to = 0 (1 +
), where CHF0 is the undisturbed CHF, L/D is the nondimensional distance from an upstream spacing device, and the constant a depends on the flow blockage of the spacing device (Groeneveld et al., 1999, 2001). Groeneveld et al. (1996, 1999) made some interim recommendations based on data from CANDU-type bundles, but their application to mixing vane grids is questionable. In general, the CHF enhancement aspects for the various mixing vane designs is proprietary information that fuel vendors generally do not release. Groeneveld et al. (1999) have also recommended various bundle-CHF correction factors that can be used in conjunction with the CHF LUT to predict the CHF in new bundle geometries for which CHF data are not yet available.
31 7 CONCLUSIONS AND FINAL REMARKS Because of the proliferation in CHF correlations (greater than 500) and CHF models (greater than 50) and because of the limited range of applicability of the models and correlations, an urgent need for a more generalized CHF prediction technique is obvious. The CHF LUT was developed in response to this need.
The CHF LUT is basically a normalized databank. Compared to other available prediction methods, the LUT approach has the following advantages: (1) it has greater accuracy, (2) it has a wider range of application, (3) it can predict the correct asymptotic trend(s), (4) it requires less computing time, and (5) it can be easily updated if additional data become available.
Despite the large database (over 40,000 data points), noticeable gaps still exist in the database at flow conditions for which CHF data are not available. The primary conditions under which data are scarce or missing are (1) high flows and high qualities, (2) low flows and low qualities, and (3) pressure ranges of 0.2 to 0.5 MPa.
The uncertainty in the regions where data are scarce or nonexistent depends on the level of extrapolation from data-based regions. The uncertainty is expected to be small at conditions slightly beyond the range of data, but it becomes larger as the extrapolation is further beyond this range.
Since the derivation of the 2006 CHF LUT, additional data sets have become available.
Sections II-2 and II-3 of Appendix II provide references to the additional data sets.
These additional data sets can be used to update the CHF LUT or to independently validate the CHF LUT.
The CHF LUT was derived based on data from 62 data sets obtained during the past 65 years. Some data lack sufficient information to assess the uncertainty of the data.
The ideal (but expensive) approach for removing the uncertainty in the database is to perform an extensive CHF experimentation by a reputable thermal-hydraulic laboratory covering all attainable2 conditions of the CHF LUT.
2 Some conditions correspond to critical flow; estimated CHF values were included in the LUT only to facilitate extrapolation from adjacent CHF conditions.
33 8 REFERENCES Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1965), Measurements of Burnout Heat Flux in Uniformly Heated Round Tubes at 1,000 psia, AERE-R 5055, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1967), Heat Transfer to Steam-Water Mixtures Flowing in Uniformly Heated Tubes in Which the Critical Heat Flux Has Been Exceeded, AERE-R 5373, Atomic Energy Research Establishment, Harwell, United Kingdom.
Bergles, A.E. (1963), Subcooled Burnout in Tubes of Small Diameter, American Society of Mechanical Engineers Winter Annual Meeting, Philadelphia, PA, November 17-22, 1963, Paper No. 63-WA-182.
Clerici, G.C., S. Garriba, R. Sala, and A. Tozzi (1966), Catalogue of Burnout Correlations for Forced Convection in the Quality Region, USAEC Rep. EURAEC-1729, United States-Euratom Joint Research and Development Program, Washington, DC.
DeBortoli, R.A., S.J. Green, B.W. LeTourneau, M. Troy, and A. Weiss (1958),
Forced-Convection Heat Transfer Burnout Studies for Water in Rectangular Channels and Round Tubes at Pressures above 500 psia, WAPD-188, Westinghouse Atomic Power Division, Westinghouse Electric Corporation, Pittsburgh, PA, October 1958.
Dell, F.R., G.F. Hewitt, R.K.F. Keeys, and R.A. Stinchcombe (1969), Burnout Heat Flux Measurements in a Long Tube, AERE-M 2216, Atomic Energy Research Establishment, Harwell, United Kingdom, June 1969, 16 pages.
Doerffer, S., D.C. Groeneveld, S.C. Cheng, and K.F. Rudzinski (1994), A Comparison of Critical Heat Flux in Tubes and Annuli, Nuclear Engineering and Design 149:167-175.
Doerffer, S., D.C. Groeneveld and S.C. Cheng (1997), A Comparison of Critical Heat Flux in Tubes and Bilaterally Heated Annuli, Nuclear Engineering and Design 177:105-120.
Doroshchuk, V.E., I.L. Levitan, and F.P. Lantzman (1975), Investigation into Burnout in Uniformly Heated Tubes, 75-WA/HT-22, American Society of Mechanical Engineers, New York, NY.
Durmayaz, A., D.C. Groeneveld, and S.C. Cheng (2004), Assessment of Critical-Heat-Flux Look-Up Tables, Experimental Data and Selected Correlations, in the Proceedings of the 6th International Conference on Simulation Methods in Nuclear Engineering, October 12-15, 2004, Montreal, Quebec, Canada.
Era, A., G.P. Gaspari, A. Hassid, A. Milani, and R. Zavattarelli (1966), Heat Transfer Data in the Liquid Deficient Region for Steam-Water Mixtures at 70 kg/cm2 Flowing in Tubular and Annular Conditions, CISE-R-184, Centro Informazioni Studi Esperienze (CISE), Milan, Italy, June 1966, 108 pages.
34 Firstenberg, H., S. Preiser, K. Goldmann, G. Rabinowitz, and L. LoBianco (1960), Compilation of Experimental Forced-Convection, Quality Burnout Data with Calculated Reynolds Numbers, NDA-2131-16, U.S. Atomic Energy Commission, Washington, DC, June 1960, 60 pages.
Groeneveld, D.C. (1986), The Onset of Dry Sheath ConditionA New Definition of Dryout, Nuclear Engineering and Design 92:135-140.
Groeneveld, D.C., S.C. Cheng, and T. Doan (1986). 1986 AECL-UO Critical Heat Flux Lookup Table, Heat Transfer Engineering 7:46-62.
Groeneveld, D.C., L.K.H. Leung, P.L. Kirillov, V.P. Bobkov, I.P. Smogalov, V.N. Vinogradov, X.C. Huang, and E. Royer (1996), The 1995 Look-Up Table for Critical Heat Flux in Tubes, Nuclear Engineering and Design 163:1-23.
Groeneveld, D.C., L.K.H. Leung, P.L. Kirillov, F.D. Auria, N. Aksan, A. Badulescu, W.-P. Baek, M.K. Chung, and J. Cleveland (1999), A General Critical Heat Flux Prediction Method for Advanced Water-Cooled Reactors, in the Proceedings of the 9th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-9), San Francisco, CA, October 3-8, 1999.
Groeneveld, D.C., I.L. Pioro, Y. Guo, S.C. Cheng, Yu.V. Antoshko, and A.Z. Vasic (2001),
Experimental and Analytical Study of the Effect of Flow Obstacles on the Critical Heat Flux, in the Proceedings of the 4th World Congress on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics, Thessalonika, Greece.
Groeneveld, D.C., J.Q. Shan, A.Z. Vasic, L.K.H. Leung, A. Durmayaz, J. Yang, S.C. Cheng, and A. Tanase (2007), The 2006 CHF Look-Up Table, Nuclear Engineering and Design 237:
1909-1922.
Hall, D.D., and I. Mudawar (2000), Critical Heat Flux (CHF) for Water Flow in TubesI.
Compilation and Assessment of World CHF Data, International Journal of Heat and Mass Transfer 43(14):2573-2604, July 2000.
Herkenrath, H., P. Mrk-Mrkenstein, U. Jung, and F.J. Weckermann (1967), Warmeubergung an Wasser bei Erzwungener Stromung in Druckbereich von 140 bis 250 bar, EUR-3658d, European Atomic Energy Community (EURATOM).
Hewitt, G.F., and N.S. Hall-Taylor (1970), Annular Two-Phase Flow, Pergamon Press, Oxford, United Kingdom.
Hewitt, G.F., H.A. Kearsey, P.M.C. Lacey, and D.J. Pulling (1965), Burnout and Film Flow in the Evaporation of Water in Tubes, AERE-R 4864, Atomic Energy Research Establishment, Harwell, United Kingdom, March 1965, 58 pages.
Hood, J.J., and L. Isakoff (1962), Heavy Water Moderated Power Reactors, DP-755, E.I. du Pont de Nemours and Company, Wilmington, DE, July 1962, 38 pages.
Huang, X.C., and S.C. Cheng (1994), Simple Method for Smoothing Multidimensional Experimental Data with Application to the CHF and Post Dryout Look-Up Tables, Numerical Heat Transfer, Part B 26(4,):425-438, December 1994.
35 Ivey, H.J., and D.J. Morris (1962), On the Relevance of the Vapour-Liquid-Exchange Mechanism for Subcooled Boiling Heat Transfer at High Pressures, AEEW-R 137, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Katto, Y. (1992), A Prediction Model of Subcooled Water Flow Boiling CHF for Pressure in the Range 0.1-20 MPa, International Journal of Heat and Mass Transfer 35(5):1115-1123.
Kirillov, P.L. (1997), 1995 Look-Up Table for Calculating the Critical Heat Flux, addendum and comments, Thermal Engineering 44(10):841-850.
Kirillov, P.L., V.P. Bobkov, E.A. Boltenko, I.B. Katan, I.P. Smogalev, and V.N. Vinogradov (1991a), New CHF Table for Water in Round Tubes, IPPE-2225, Institute of Physics and Power Engineering, Obninsk, Russia.
Kirillov, P.L., V.P. Bobkov, E.A. Boltenko, V.N. Vinogradov, I.B. Katan and I.P. Smogalev, (1991b), Lookup Tables of Critical Heat Fluxes, Atomnaya Energiya 71:18-28 (in Russian).
Kirillov, P.L., V.P. Bobkov, E.A. Boltenko, V.N. Vinogradov, A.A. Ivashkevitch, I.B. Katan, and I.P. Smogalev (1989a), A Method of the Development of Standard CHF Data for Tubes with Uniform Heat Flux, F.E. Dzerzhinskii, All-Union Heat Engineering Institute, FEI-2030, Obninsk, Russia (in Russian).
Kirillov, P.L., V.P. Bobkov, V.N. Vinogradov, V.S. Donisov, A.A. Ivashkevitch, I.B. Katan, E.I.
Paniutchev, I.P. Smogalev, and O.B. Salnikova (1989b), On Standard Critical Heat Flux Data for 10 mm ID Tubes, in the Proceedings of the 4th International Topical Meeting on Nuclear Reactor Thermal Hydraulics, Volume 1, pp. 103-108, Karlsruhe, Germany.
Lee, D.H. (1965), An Experimental Investigation of Forced Convection Burnout in High-Pressure Water. Part III: Long Tubes with Uniform and Nonuniform Heat Flux, AEEW-R 355, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Lee, C.H., and I. Mudawar (1988), A Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling Based on Local Bulk Flow Conditions, International Journal of Multiphase Flow 14:711-728.
Lee, D.H., and J.D. Obertelli (1963), An Experimental Investigation of Forced Convection Boiling in High Pressure Water, AEEW-R 213, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Leung, A., S. Banerjee, and D.C. Groeneveld (1982), Investigation of the Effects of Heater Characteristics on CHF Performance of a Long Vertical Annulus in High Pressure Water, in the Proceedings of the 7th International Heat Transfer Conference, Volume 4, pp. 303-308, Munich, Germany.
Lowdermilk, W.H., C.D. Lanzo, and B.L. Siegel (1958), Investigation of Boiling Burnout and Flow Stability for Water Flowing in Tubes, NACA-TN-4382, National Advisory Committee for Aeronautics (NACA), Cleveland, OH, September 1958.
Matzner B., E.O. Moeck, J.E. Casterline, and G.A. Wikhammer (1965), Critical Heat Flux in Long Tubes at 1,000 psi with and without Swirl Promoters, 65-WA/HT-30, AECL-2446, Proceedings of the American Society of Mechanical Engineers, New York, NY, 16 pages.
36 Mayinger F., O. Schad, and E. Weiss (1966), Untersuchung der kritischen Heizflachenbelastung (Burnout) bei sieden dem Wasser, Investigation into the Critical Heat Flux in Boiling, Report No. 09.03.01, Maschinenfabrik Augsburg-Nurnberg AG, Munich, Germany, May 1966.
McAdams, W.H., C.S. Minden, R. Carl, D.M. Picornell, and J.E. Dew (1949), Heat Transfer at High Rates to Water with Surface Boiling, Journal of Industrial and Engineering Chemistry 41:1945-1953.
Mishima, K., et al. (1985), Boiling Burnout and Instability for Water Flowing in Round Tubes under Atmospheric Pressure, International Journal of Heat and Mass Transfer 28(6):
1115-1129.
Mishima, K., et al. (1987), Effect of Channel Geometry on Critical Heat Flux for Low Pressure Water, International Journal of Heat and Mass Transfer 30(6):1169-1182.
Tain, R.M., D.C. Groeneveld, and S.C. Cheng (1995), Limitations of the Fluid-to-Fluid Scaling Techniques for Critical Heat Flux in Flow Boiling, International Journal of Heat and Mass Transfer 38:2195-2208.
Taitel, Y., and A.E. Dukler (1975), A Model for Predicting Flow Regime Transitions in Horizontal and Near Horizontal Gas/Liquid Flow, 750WA/HT829, American Society of Mechanical Engineers, New York, NY, and also AIChE Journal 22.
Tanase, A., et al. (2009), Diameter Effect on the Critical Heat Flux, Nuclear Engineering and Design 239:289-294 Thompson, B., and R.V. MacBeth (1964), Boiling Water Heat Transfer Burnout in Uniformly Heated Round Tubes: A Compilation of World Data with Accurate Correlations, AEEW-R 359, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Tong, L.S. (1965), Boiling Heat Transfer and Two-Phase Flow, John Wiley & Sons, New York, NY.
Tong, L.S. (1968), Boundary-Layer Analysis of the Flow Boiling Crisis, International Journal of Heat and Mass Transfer 11:1208-1211.
Tong, L.S., and G.F. Hewitt (1972), Overall View Point of Flow Boiling CHF Mechanisms, 72-HT-54, American Society of Mechanical Engineers, New York, NY.
Weisman, J. (1992), The Current Status of Theoretically Based Approaches to the Prediction of the Critical Heat Flux in Flow Boiling, Nuclear Technology 99:1-21, July 1992.
Weisman, J., and B.S. Pei, (1983), Prediction of Critical Heat Flux in Flow Boiling at Low Qualities, International Journal of Heat and Mass Transfer 26:1463-1477.
Wong, Y.L., D.C. Groeneveld, and S.C. Cheng (1990), CHF Predictions in Horizontal Tubes, International Journal of Multiphase Flow 16:123-138.
Wong, W. (1994), Effect of Diameter on the Critical Heat Flux, Master of Applied Science Thesis, Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.
37 Ying, S.H., and J. Weisman (1986), Prediction of the CHF in Flow Boiling at Intermediate Qualities, International Journal of Heat and Mass Transfer 29(11):1639-1648.
Zenkevich, A. (1974), Analysis and Generalization of Experimental Data on Heat Transfer Crisis Associated with Forced Convection of Cooling Water in Tubes, AECL-Tr-Misc.-304, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada.
Zuber, N. (1959), Hydrodynamic Aspects of Boiling Heat Transfer, Ph.D. Thesis, AECU-4439, Research Laboratory, Los Angeles and Ramo-Wooldridge, University of California Los Angeles, California.
39 APPENDIX A
SUMMARY
DESCRIPTIONS OF CRITICAL HEAT FLUX EXPERIMENTAL DATA USED TO DERIVE THE 2006 CRITICAL HEAT FLUX LOOKUP TABLE Alekseev et al. (1964)
The original reference is in Russian and did not contain the numerical data, but the data plots were of good enough quality for extraction using graphical digitization techniques. However, the data used for the lookup table (LUT) derivation were taken from Kirillovs database (1,064 data points were labeled as Alekseev 1964), which was in digital form and was transferred to the University of Ottawa (UofO) in 1991. Kirillov presumably obtained the Alekseev et al. data directly from Alekseev. The table below lists the ranges of conditions of the data set.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 1,064 10.00 10.01 1.000 4.966 9,800 19,610 216 7,566
-0.866 0.944 57 1,398 134 4,949 139.77 357.93
REFERENCE:
Alekseev, G.V., B.A. Zenkevich, O.L. Peskov, N.D. Sergeev, and V.I. Subbotin (1964),
Burn-Out Heat Fluxes under Forced Water Flow, in the Proceedings of the 3rd United Nations International Conference on the Peaceful Uses of Atomic Energy, A/CONF.28/P/327a, International Atomic Energy Agency, Vienna, Austria, pp. 295-304.
Alessandrini et al. (1963)
Alessandrini et al. (1963) obtained data for upward flow of steam-water mixtures in vertical tubes. The data set contained 753 data points of which 161 were used to derive the 2006 LUT.
The two test sections (G1 and G2) were made from seamless American Iron and Steel Institute (AISI) Type 321 (G1) or 304 (G2) stainless steel tubing. The heated length varied from 0.796-2.456 meters with a uniform heat flux distribution. The inlet quality varied from 0.208 to 0.677.
The following effects were also investigated:
the effect of the heated length (L) or of the length-to-diameter (L/D) ratio on the CHF the influence of a mixer at the inlet of the test section and a steam separator at the outlet of the test section on the critical heat flux (CHF) the effect of an intermediate nonheated section between two heated sections
40 The table below lists the ranges of conditions that the CHF test covered.
Tube Diameter Tube Length Heated Length Pressure Mass Flux Local Quality Heat Flux Inlet Temperature mm m
m kPa kg m-2 s-1 kW m-2
°C 15.2 (G2) 24.9 (G1) 2.917 (G1) 2.916 (G2) 0.796 2.456 4,874 5,099 1,080 3,990
-0.05 0.74 214 3,662 186 266
REFERENCE:
Alessandrini, A., G. Peterlongo, and R. Ravetta (1963), Large Scale Experiments on Heat Transfer and Hydrodynamics with Steam-Water Mixtures: Critical Heat Flux and Pressure Drop Measurements in Round Vertical Tubes at the Pressure of 51 kg/cm2 abs., CISE-R-86, Centro Informazioni Studi Esperienze (CISE), Milan, Italy.
Babarin et al. (1969)
The Babarin et al. (1969) CHF data set for upward flow in a smooth tube contained 163 data points. The test section was a vertical, uniformly heated stainless steel tube with a 12-millimeter (mm) inner diameter (ID) and a heated length varying from 0.96 to 1.8 m. The quality was calculated from a heat balance. Because the CHF equals zero at the maximum critical quality of 1.0 and this data set has 49 CHF data points with quality greater than 1, the accuracy of the complete data set is in question. The table below lists the ranges of conditions covered by the CHF test.
Tube Diameter Tube Length Pressure Mass Flux Heat Flux Thermodynamic Quality Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 12 0.96 1.8 290 304 50 500 190 2,300 0.4665 1.0903 15 124
REFERENCE:
Babarin, V.P., R.I. Sevastyanov, and I.T. Aladyev (1969), A Special Hydrodynamic Effect on the Boiling Crisis in Tubes, Heat TransferSoviet Research 1(4):34-41, July 1969.
Babcock and Hood (1962)
The Babcock and Hood 1962 data are virtually the same as the Hood (1962) data although Hood (1962) has approximately 50 percent more data, which is not surprising because the source is also the same. The slight differences (within a few percentage points) are probably the result of the different unit conversions and properties used. The table below lists the test conditions.
41 Number of data points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 39 8.00 22.5 0.61 413 6,890 2,946 11,452
-0.187
-0.05 202 639 4,876 10,546 19 177
REFERENCES:
Hood, J.J. (1962), Heavy Water Moderated Power Reactors, DP-725, E.I. du Pont de Nemours and Company, Wilmington, DE, April 1962, 53 pages.
Babcock, D.F., and R.R. Hood (1962), Heavy Water Moderated Power Reactors, DP-725, E.I. Dupont de Nemours and Company, Wilmington, DE.
Baek (2001)
An electronic copy of this data set was obtained in private communication with the author, W.-P.
Baek, from the Korean Advanced Institute of Science and Technology (KAIST). This data set is sometimes referred to as Baik (2001). Details of the experiment are not known except that the CHF corresponds to a sharp wall temperature rise of about 100 degrees Kelvin above the saturation temperature. This data set contains 63 data points of which 34 were used for the LUT derivation. The table below lists the ranges of flow parameters.
Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Heat Flux Critical Quality Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 6.0 10.0 0.180 0.480 30.0 80.0 101.0 3,618.0 299.0 2,032.0 1,222.0 7,412.8
-0.109 0.099 5.9 40.2
REFERENCE:
Baek, W.-P. (2001), KAIST, Korea. Data obtained through private communication with D.C. Groeneveld.
Bailey (1977)
The vertical test section was made from a 15-mm-ID (18-mm outside diameter) Inconel tube and had a uniformly heated length of 5.4 meters. The test section was instrumented with 58 thermocouples attached to the tube in diametrically opposed pairs, generally every 76 mm.
The experiments were performed by measuring the CHF occurrence at the outlet and by subsequently increasing the power such that the CHF spread upstream and post-CHF temperatures could be measured. The report contains tables of CHF data. The table below lists ranges of flow parameters.
42 Tube Diameter Pressure Mass Flux Heat Flux Thermodynamic Quality Surface Temperature mm kPa kg m-2 s-1 kW m-2
°C 15 1,370 6,990 49 668 84 799 0.78 1.21 200 697 The post-CHF temperatures can be extracted from Figures 8-17 (Bailey, 1977) in which the wall temperature is plotted as a function of thermodynamic quality.
REFERENCE:
Bailey, N.A. (1977), Dryout and Post Dryout Heat Transfer at Low Flow in a Single Tube Test Section, AEEW-R 1068, United Kingdom Atomic Energy Authority, Harwell, United Kingdom (United Kingdom).
Bailey and Lee (1969)
This CHF data set contains 158 data points. The test section consisted of a vertical tube through which the water flowed upwards. The tube was made from commercial stainless steel-grade AISI 316. Inlet and outlet bulk temperatures were measured with chromel-alumel thermocouples. For greater accuracy, Chromel/Constantan thermocouples were used for the wall temperature measurement. The table below lists the ranges of flow parameters.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 158 9.30 3.05 6,895 18,340 958 4,242 0.069 0.727 54 604 344 2,221 199 347
REFERENCE:
Bailey, N.A., and D.H. Lee (1969), An Experimental and Analytical Study of Boiling Water at 2,000 to 2,600 psi. Part I: Dryout and Post-Dryout Heat Transfer, AEEW-R 659, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Becker et al. (1963)
This experiment obtained 809 burnout measurements covering the conditions listed in the table below.
Tube Diameter Heated Length Pressure Mass Flux Steam Quality Heat Flux Inlet Subcooling mm mm kg cm-2 kg m-2 s-1 W cm-2
°C 10.04 (except for Lh = 600 mm where the ID = 9.9 mm) 600 2,500 5.3 37.3 100 1,890 0.20 0.95 50 515 56 212
43 In the graphically presented results, the burnout steam quality (X) was plotted against the pressure with the surface heat flux as parameter. This report did not tabulate any data. After cross-checking the data, it was found that Table 1.2 in AE-177 (Becker et al., 1965) also contains the data (i.e., Report AE-177 contains a compilation of all Swedish tube CHF data up to 1965).
The test section was made of stainless steel tube and was 2,800 mm long with a 10.04-mm ID.
During the first test series, the copper power clamps were placed in such a way that the heated length was 2,500 mm. Afterwards, the lower power clamp was moved upwards in steps of 250 mm so that heated lengths of 2,250, 2,000, 1,750, 1,500, 1,250, and 1,000 mm were obtained. In addition, the report includes runs performed with a test section having a 9.96-mm ID and 600-mm heated length.
To protect the test section, a burnout detector was used to switch off the power supply when excessive temperatures occurred in the last 100-mm length of the test section. The excessive temperature often occurred suddenly, indicating that burnout conditions had been reached.
Burnout always occurred just below the upper power clamp.
REFERENCES:
Becker, K.M., P. Persson, L. Nilsson, and O. Eriksson (1963), Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Round Ducts, AE-114 (Part 2),
Aktiebolaget Atomenergi, Stockholm, Sweden.
Becker, K.M., O. Hernborg, M. Bode, and O. Eriksson (1965), Burnout Data for Flow of Boiling Water in Vertical Round Ducts, Annuli and Rod Clusters, AE-177, Aktiebolaget Atomenergi, Stockholm, Sweden.
Becker (1965)
AE-177 (Becker et al., 1965) and AE-178 (Becker, 1965) basically compile all Swedish CHF data up to 1965.
Table I of AE-177 contains the tables of the burnout data obtained in Sweden by Becker for flow in vertical channels at the Heat Engineering Laboratory of AB Atomenergi in Stockholm, Sweden. The data are a compilation of Swedish CHF data obtained in tubes, annuli, and three-and seven-rod clusters.
Table I in AE-177 contains 3,473 round tube data points, including the tube CHF data of Becker et al. (1963), as follows:
Table I.1 in AE-177 contains 571 data points that are also found in CD Spreadsheet CHF Data for 2006 LUT.xls (#901-1459).
Table I.2 in AE-177 contains about 1,787 data points. The first 162 data points are also found in CD Spreadsheet CHF Data for 2006 LUT.xls (#1490-1649). Runs 163-971 are the same data from AE-114 (Becker et al., 1963) and are found in CD Spreadsheet CHF Data for 2006 LUT.xls #1650-2458. For run numbers greater than 971, the data are again found in CD Spreadsheet CHF Data for 2006 LUT.xls, while some of the runs are duplicated in Table 1.2 in AE-178.
44
The 273 CHF data points in Table 1.3 in AE-177 are also found in CD Spreadsheet CHF Data for 2006 LUT.xls while some of the data are duplicated in Table 1.3 in AE-178. All data in CD Spreadsheet CHF Data for 2006 LUT.xls were used to derive the 2006 CHF LUT.
Table I.4 in AE-177 contains 811 CHF data points that also appear in Table 1.4 in AE-178, but Table 1.4 in AE-177 contains an additional 32 data points obtained in a 20.02-mm tube. The first 665 runs are also in the CD Spreadsheet CHF Data for 2006 LUT.xls (#5005-5664).
The tables in AE-178 include the following:
Table I in AE-178 comprises Table 1.2 (P = 2.7-31), Table 1.3 (P = 41), and Table 1.4 (P > 41 kilograms per square meter (kg/m2)). Table I.2 contains about 460 Swedish CHF data points, Table I.3 contains about 28 data points, and Table I.4 contains about 770 CHF data points (in total, about 1,258 data points). In Table 1.4 of AE-178, runs 1-665 were the same as CD Spreadsheet CHF Data for 2006 LUT.xls runs (#5005-5664). However, runs 666-861 of Table I.4 obtained in 19.93-and 24.95-mm tubes could not be located in the CD Spreadsheet CHF Data for 2006 LUT.xls database because the tube diameter greater than 16 mm was possibly outside the range of interest of the CHF LUT.
Table II in AE-178 contains about 400 tube CHF data points labeled as Columbia University Ref. 7, which refers to the following report:
Babcock, D.F. (coordinator), Heavy Water Moderated Power Reactors, Progress Reports May-June 1963 and January-February 1964, Atomic Energy Commission Research and Development Reports DP-855 and DP-895, Savannah River Laboratory, Aiken, South Carolina.
These data were obtained in tubes with IDs ranging from 6.22 to 37.47 mm and pressures ranging from 52.7 to 105.7 kilograms per square centimeter (kg/cm2). These data apparently were not used for the 2006 CHF LUT derivation.
Table III of AE-178 contains 626 CHF tube measurements labeled as Winfrith Data Ref. 13, which refers to the following reference:
Lee, D.H., and J.D. Obertelli (1963), An Experimental Investigation of Forced Convection Boiling in High Pressure Water, AEEW-R 213, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
The Table III data were obtained in tubes with IDs ranging from 5.59 to 11.46 mm and pressures ranging from 40 to 135 kg/cm2. The original Lee and Obertelli reference is contained in the supplementary CHF database in Section 6.3, but these data were not used for the 2006 CHF LUT derivation.
The table below lists test conditions taken from AE-178. The 811 CHF measurements were obtained in a tube with an ID of 9.98 mm. Reference is also made to the earlier 488 measurements by Becker in tubes at pressures of 2.7, 10, 20, and 30 kg/cm2, which appear in Table 1.2 in AE-178.
45 No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 K
kW m-2 811 9.98 1-3.5 4,100-10,100 222-3,477 0.01-0.98 56-240 510-4,340
?
3.93-24.97 1-2.5 3,100-7,100 220-5,450 0-0.96 53-230 1,000-5,700 The processed data appear to be confusing. Runs 1-843 of the processed data correspond to the data of Table I.4 in both AE-177 and AE-178. However, the authors have been unable to find the source of the data for runs 1001-1500. These data appear in the CD Spreadsheet CHF Data for 2006 LUT.xls file (#5666-6049).
REFERENCES:
Becker, K.M. (1965), An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, AE-178, Aktiebolaget Atomenergi, Stockholm, Sweden.
Becker, K.M., O. Hernborg, M. Bode, and O. Eriksson (1965), Burnout Data for Flow of Boiling Water in Vertical Round Ducts, Annuli and Rod Clusters, AE-177, Aktiebolaget Atomenergi, Stockholm, Sweden.
Becker (1970)
The purpose of this experiment was to investigate the CHF at conditions not covered by Beckers previous experiments (i.e., in tubes with an ID of 2.40, 3.00, and 36.05 mm at pressures of 30, 50, and 70 bar). The small diameter tubes had a heated length of 500 mm, and the heated length of the large diameter tube was 1,880 mm. Because of limitations on the available power supply, only low-flow (95-428 kilograms per square meter per second (kg m-2 s-1) CHF measurements were possible for the large diameter tube. The mass flux range for the small diameter tube was 290 to 2,725 kg m-2 s-1. The report tabulated the CHF measurements. Of the 113 CHF measurements obtained in the 2.4-and 3.0-mm tubes, 69 were included in the CD Spreadsheet CHF Data for 2006 LUT.xls data file (#13142-13211) and were used in the 2006 LUT derivation. The 47 CHF measurements obtained for the tube with an ID of 36.03 mm were not used in the derivation of the 2006 LUT because the diameter was too large.
Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 2.40 36.05 0.500 1.880 3,050 7,100 93.3 2,725 0.207 0.903 371 1,065 1,026 5,130 51.75 113.22
46
REFERENCE:
Becker, K.M. (1970), Burnout Measurements in Vertical Round Tubes, Effect of Diameter, TPM-RL-1260, Aktiebolaget Atomenergi, Teknisk PM, Stockholm, Sweden, December 1970, 16 pages.
Becker et al. (1971)
This report contains a large amount of data (1,650 data points) obtained in 10-mm-ID tubes with a heated length of 1, 2, 3, and 4.966 meters (Becker et al., 1971). This database contains 90 CHF data points obtained in a 10-mm-ID tube having a 2-meter heated length with pressures of 3-, 5-, 7-, and 9 megapascals (MPa). These data points, also reported by Nilsson (1970),
were used as part of the European CHF reproducibility exercise (CISE, 1970). The database used to derive the LUT (see CD Spreadsheet CHF Data for 2006 LUT.xls) contains 1,435 data points (Data #13240-14674 from Becker et al. (1971)) obtained in about 10-mm-ID tubes.
Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 10.00 10.01 1.000 4.966 3,000 20,000 156 8,111
-0.866 1.061 26 1,414 135 5,476 124.75 358.65
REFERENCES:
Becker, K.M., G. Strand, D. Djursing, O. Eklind, K. Lindberg, and C. sterdahl (1971),
Round Tube Burnout Data for Flow of Boiling Water at Pressures Between 30 and 200 bar, KTH-NEL-14, Royal Institute of Technology, Stockholm, Sweden.
Nilsson, L. (1970), Repeatability Tests of Critical Heat Flux Data for 1970 Meeting of the European Two-Phase Flow Group, Comparison of Results by Beckers Burnout Correlation, AE-TPM-RL-1229, Aktiebolaget Atomenergi, Stockholm, Sweden, June 1970, 24 pages.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, CISE Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970.
Bennett et al. (1965)
Bennet et al. (1965) performed the CHF experiments in the United Kingdom Atomic Energy Authoritys Harwell high-pressure loop using stainless steel tubular test sections. Most tests were performed inside 0.497-inch tubes, but tests using a limited test matrix were also performed in tubes with a nominal 3/8-inch bore. The latter tests investigated the effect of wall thickness by varying the thickness from 0.036 inch to 0.082 inch. The effect was negligible.
47 No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 201 9.22 12.62 1.524 5.563 6,612 7,481 623.8 5,844.4 0.026 0.948 21 691 589.6 3,299.7 157.67 279.45
REFERENCE:
Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1965), Measurements of Burnout Heat Flux in Uniformly Heated Round Tubes at 1,000 psia, AERE-R 5055, United Kingdom Atomic Energy Authority, Harwell, UK.
Bergelson (1980)
The data set labeled as Bergelson was used for the 2006 LUT derivation and was part of the data compilation transferred to UofO by Kirillov. The paper labeled as Bergelson (1980) does not contain these data; instead, it contains only subcooled CHF data obtained under forced convective conditions in several fluids, including a few water data, in graphical form. The table below lists the ranges of CHF test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 328 8.00 0.241 0.400 170 3,080 1,927 7,078
-0.295 0.090 96 853 3,511 14,571 28.94 169.20
REFERENCE:
No reference.
Bergles (1963)
Bergles performed subcooled CHF tests at the Massachusetts Institute of Technology test facility using small-diameter tubing (stainless steel) at low pressure with variable wall thickness (0.006 to 0.036 inch) and short heated lengths. The effect of wall thickness was found to be insignificant. The CHF decreased with increasing diameter. The table below lists the ranges of flow conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 117 0.62 6.21 0.011 0.155 140 586 1,518.7 24,272.4
-0.137 0.111 25 534 4,957.1 44,713 3.10 116.55
48 The data were extracted from Figures 3-8 (Bergles, 1963) using graphical digitization techniques. This introduces additional errors. Only seven data points were used for the 2006 LUT derivation.
REFERENCE:
Bergles, A.E. (1963), Subcooled Burnout in Tubes of Small Diameter, 63-WA-182, American Society of Mechanical Engineers Winter Annual Meeting, Philadelphia, PA, November 17-22, 1963.
Borodin and Macdonald (1983) and Leung (1982)
These two references refer to the same data set, which was measured by Borodin and MacDonald (1983) at Atomic Energy of Canada Limited (AECL) in Chalk River, Ontario, Canada, but analyzed by Leung (1982). Because of the restricted distribution of this data, the test parameters and CHF data are not included here.
REFERENCES:
Borodin, A. (1983), AECL Internal Report CRNL-2538. Restricted Distribution.
Leung, A. (1982), A study of the CHF Performance of Light and Heavy Water in Long Vertical Tubes, AECL Power Projects Report AI-1024, Sheridan Park, Canada.
Restricted Distribution.
Burck and Hufschmidt (1965)
CHF measurements were obtained for subcooled water in directly heated 10-mm-ID tubes. The tube material was not specified (likely stainless steel). The authors refer to a special burnout detector, which was described elsewhere (i.e., the reference is not available). The table below lists the ranges of flow conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 143 10.0 0.35 1,100 3,090 917 3,756
-0.246 0.087 532 939 4,500 12,200 16.7 60.8
REFERENCE:
Burck, E., and W. Hufschmidt (1965), Measurement of the Critical Heat-Flux-Density of Subcooled Water in Tubes at Forced Flow, EUR 2432.d, Australian Atomic Energy Commission, Research Establishment, Sydney, Australia, Translated by J.B. Hopkinson, July 1969, LIB/TRANS 210, 40 pages.
Celata et al. (1992a)
This data set is referred to as Celata et al. (1992a) in Table 4-2 of this report. Tests were performed in 6-and 8-mm-ID tubes having a wall thickness of 0.25 mm and very short heated
49 lengths (10 to 15 centimeters (cm)). Because of the high subcooling, the CHF was very high, which physically damaged the test section when CHF conditions were reached. The table below lists the ranges of flow conditions.
No. of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 60 6.00 8.00 0.10 0.15 398 5,120 2,019 10,046
-0.517
-0.106 350 1,018 7,428 29,514 29 81
REFERENCE:
Celata, G.P., M. Cumo, and A. Mariani (1992a), CHF in Highly Subcooled Flow Boiling with and without Turbulence Promoters, Meeting of the European Two-Phase Flow Group, Paper C1, Stockholm, Sweden, June 1-3, 1992, 14 pages.
Celata et al. (1992b)
This data set is referred to as Celata et al. (1992b) in Table 4-2 of this report. Tests were performed in 2.5-and 5-mm-ID tubes made of Type 304 stainless steel and short (20- to 40-cm) heated lengths. Because of the high subcooling, the CHF was very high, which physically damaged the test section when CHF conditions were reached. The table below lists the range of flow conditions.
No. of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 78 2.50 5.00 0.20 0.40 107 2,181 2,166 32,637
-0.091 0.287 345 790 5,347 42,777 19 55
REFERENCE:
Celata, G.P., M. Cumo, and A. Mariani (1992b), Subcooled Water Flow Boiling CHF with Very High Heat Fluxes, Revue Générale de Thermique 31(362):106-114.
Celata and Mariani (1993)
The Celata and Mariani (1993) database contains 1,887 CHF data points from 23 references that had been scanned and digitized in the 1990s; 1,357 of these data points were obtained in round tubes and were tabulated separately. This database was transferred to UofO by G.P.
Celata (see Celata (1993) below).
50 The data are from (1) Reference 2 of Celata and Mariani (1993), which is also referred to as Celata et al. (1993) (see the International Journal of Heat and Mass Transfer article referenced below) and (2) Reference 4 of Celata and Mariani (1993), which is an unpublished report from the Italian National Agency for New Technologies and Sustainable Economic Development (ENEA) and therefore not available.
REFERENCES:
Celata, G.P., and A. Mariani (1992), A Data Set of Critical Heat Flux in Water Subcooled Flow Boiling, Addendum to the Specialists Workshop on the Thermal Hydraulics of High Heat Flux Components in Fusion Reactors, ENEA, Casaccia, Rome, Italy, September 9-12, 1992.
Celata, G.P., M. Cumo, and A. Mariani (1993), Burnout in Highly Subcooled Flow Boiling in Small Diameter Tubes, International Journal of Heat and Mass Transfer 36:1269-1285.
Celata, G.P. (1993), Personal communication letter between G.P. Celata and Professor S.C. Cheng, University of Ottawa, Ottawa, Ontario, Canada, April 22, 1993.
Celata et al. (1993)
These CHF experiments were designed in support of fusion reactors that require very high heat flux removal rates (up to 60 megawatts per square meter) from the diverters. The experiments were performed in small diameter stainless steel (2.5-mm-ID) tubes with a wall thickness of 0.25 mm and a heated length of 100 mm. It is unclear whether Celata et al. (1993) used these data for the LUT derivation. The table below lists the ranges of test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 78 2.50 0.10 578 2,714 11,240 40,000
-0.357
-0.104 387 844 12,113 60,579 30 70.5
REFERENCE:
Celata, G.P., M. Cumo, and A. Mariani (1993), Burnout in Highly Subcooled Water Flow Boiling in Small Diameter Tubes, International Journal of Heat and Mass Transfer 36(5):1269-1285.
Cheng et al. (1983a, 1983b)
The original references for these two data sets are no longer available. Cheng and his students performed CHF tests on the low-pressure UofO test facility. The table below lists the ranges of test conditions.
51 No. of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 150 12.60 0.370 0.740 101 687 50 400 0.187 1.227 42 210 331.2 2,115 132 4.80 0.19 0.38 100 700 300 750 0.082 0.765 42 214 889 2,131
REFERENCES:
Cheng, S.C., K.T. Poon, P. Lau, K.T. Heng, T. Doan, and C.Y. Chan (1983a), CHF Experiments and Construction of CHF Table, University of Ottawa, Ottawa, Ontario, Canada, AECL Contract, 1st Progress Report, July 1982-March 1983.
Cheng, S.C., K.T. Poon, T. Doan, S.K. Chin, and Y.M. Koo (1983b), CHF Experiments and Construction of CHF Table, University of Ottawa, Ottawa, Ontario, Canada, AECL Contract, Contract Report No. 2, December 1983.
CISE (1970)/Nilsson (1970) European CHF Reproducibility Exercise Because of concerns that CHF measurements could vary significantly between different laboratories even though the test equipment and the test conditions were nominally identical, the European Two-Phase Group decided to perform a so-called CHF reproducibility exercise.
The objective of this reproducibility exercise was to determine the variation in CHF measurements between various laboratories. CISE (1970) and Nilsson (1970) reported the results of this exercise. The very large CISE report contains individual chapters written by each of the participating laboratories. Nilssons report (1970) also contains all individual data sets (i.e., a total of 594 CHF measurements were taken by the participating laboratories) and describes the analysis of the data.
The following organizations/laboratories participated in the exercise:
AB Atomenergi (AE), Nykping, Sweden Allgemeine Elektricitts-Gesellschaft AG, Telefunken, Frankfurt am Main, Germany Commissariat lEnergie Atomique, Paris, France CISE, Milan, Italy EUR, Ispra, Italy Maschinenfabrik Augsburg-Nurnberg AG, Munich, Germany Societ Ricerche Impianti Nucleari (Sorin), Italy United Kingdom Atomic Energy Authority, Harwell, United Kingdom
52 The table below lists the nominal test conditions.
Tube Diameter Heating Length Pressure Mass Flux Inlet Subcooling mm m
MPa kg m-2 s-1 kJ kg-1 10 2
3, 5, 7, and 9 260 6,000 15 3,235 The above ranges of conditions were the maximum ranges; the ranges of conditions were different for the various laboratories.
The discrepancy in CHF values was expected to be within 10 percent; however, the discrepancy initially exceeded 30 percent. After careful examination of the two outliers (the other laboratories were within 10 percent), two laboratories found inconsistencies in their measurement approach and hardware (which may have given rise to flow instabilities), and one laboratory withdrew its results.
REFERENCES:
CISE (1970), Exercise on Reproducibility of Critical Heat Flux DatePresentation of Experimental Results, Meeting of the European Two-Phase Group, June 9-11, 1970, Milan, Italy.
Nilsson, L. (1970), Repeatability Tests of Critical Heat Flux Data for [the] 1970 Meeting of the European Two-phase Flow Group, Comparison of Results by Becker's Burnout Correlation, AE-TPM-RL-1229, Aktiebolaget Atomenergi, Stockholm, Sweden, 23 pages.
Dell et al. (1969)
Burnout heat flux measurements were reported for water flowing upward in a 0.243-inch ID stainless steel tube. Tube lengths of up to 217 inches were used, which gave an L/D ratio higher than that used in previous experiments. CHF occurrence was detected by a Wheatstone bridge at the end of the heated length where CHF occurred first (i.e., because stainless steel has a fairly high temperature coefficient of resistivity, it is suitable for use as a part of the Wheatstone circuit). CHF values were obtained for mass velocities of 1x106, 2x106, and 3x106 pounds per hour per square foot with an outlet pressure of 1,000 pounds per square inch, absolute (psia).
No. of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 82 6.17 0.914 5.512 6,895 14,328.9 4,135.8 0.144 0.779 79 365 492.7 3,340.4
53
REFERENCE:
Dell, F.R., G.F. Hewitt, R.K.F. Keeys, and R.A. Stinchcombe (1969), Burnout Heat Flux Measurements in a Long Tube, AERE-M 2216, Atomic Energy Research Establishment, Harwell, United Kingdom, June 1969, 16 pages.
Doerffer (1999)
This proprietary data set belongs to AECL. The electronic copy of this data set was obtained through private communication with the author. An AECL unpublished report contains details of the experiment. Because the data set is proprietary, the test parameters and CHF data are not included here.
REFERENCE:
Personal communication with D.C. Groeneveld (original reference: Doerffer, S. (1999),
Effect of Flow Orientation on CHF in Smooth Tubes, AECL unpublished report).
Doerffer et al. (1997)
This proprietary data set belongs to AECL. The electronic copy of this data set was obtained through private communication with the author. An AECL unpublished report contains details of the experiment. However, a recent paper by Doerffer and Groeneveld (1999) describes the same data set. Because the data set is proprietary, the test parameters and CHF data are not included here.
REFERENCES:
Doerffer, S., K.F. Rudzinski, and D.C. Groeneveld (1997), Fluid-to-Fluid Modelling of CHF Enhancement in a Tube, AECL unpublished report RC-1922, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada.
Doerffer, S., and D.C. Groeneveld (1999), Fluid-to-Fluid Modelling of CHF Enhancement in a Tube, in the Proceedings of the 9th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-9), San Francisco, CA, October 3-8, 1999.
Era et al. (1966)
CHF data were extracted from this post-dryout experiment. The accuracy of the results depends on the axial spacing of the thermocouples (20 cm in this experiment) and, therefore, is slightly below that of regular CHF tests. The tests were performed using an 8-mm-ID stainless steel tube with a heated length of 4.8 m. The wall thickness was 1.5 mm. The table below lists the test conditions.
54 No. of Data Points Tube Diameter Heating Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 163 5.98 1.602 4.800 6,777 7,049 1,105 3,014.9 0.374 0.952
-1,211 565 109.2 1,960.9
REFERENCE:
Era, A., G.P. Gaspari, A. Hassid, A. Milani, and R. Zavattarelli (1966), Heat Transfer Data in the Liquid Deficient Region for Steam-Water Mixtures at 70 kg/cm2 Flowing in Tubular and Annular Conditions, CISE-R-184, Centro Informazioni Studi Esperienze, Milan, Italy, June 1966, 108 pages.
Griffel (1965)
This thesis contains a large amount of CHF data obtained in different diameter tubes. All tubes were made of Type 304 stainless steel. The flow was vertically upwards. These data were used in the derivation of the CHF LUT. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 397 6.22 37.46 0.610 1.972 3,448 10,343 637.3 18,577.2
-0.209 0.592 45 1,209 1,400.6 8,107.3
REFERENCE:
Griffel, J. (1965), Forced Convection Boiling Burnout for Water in Uniformly Heated Tubular Test Sections, Doctor of Engineering Science Thesis, Columbia University, New York, NY.
Groeneveld (1985)
Groeneveld (1985) contains a proprietary data set.
REFERENCE:
Groeneveld, D.C. (1985), AECL internal unpublished report, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada.
55 Hewitt et al. (1965)
CHF experiments were performed in directly heated stainless steel tubes with vertical flow upwards. Burnout detector trip wires were attached to the exit end of the test section and were connected to a Wheatstone-type bridge, which detected any difference in electrical resistance (resulting from change in tube temperature) between parts of the test section immediately adjacent to the downstream end and the parts just below that. Any imbalance in the bridge actuated the circuit breaker and cut off the electrical power supply. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 442 9.30 0.229 3.048 101 208 90.9 301 0.160 1.083
-41 383 144 4,013
REFERENCE:
Hewitt, G.F., H.A. Kearsey, P.M.C. Lacey, and D.J. Pulling (1965), Burnout and Film Flow in the Evaporation of Water in Tubes, AERE-R 4864, Atomic Energy Research Establishment, Harwell, United Kingdom, March 1965, 58 pages.
Hood (1962)
These tests were likely obtained using a similar visual burnout detection as described by Hood and Isakoff (1962) (see the section titled, Hood and Isakoff (1962), below). The flow was downwards, which probably would not have affected the results because the flow was quite high. The Babcock and Hood (1962) data are virtually the same as the Hood (1962) data although Hood (1962) has about 50 percent more data. This is not surprising because the source is also the same. The slight differences (within a few percentage points) is probably the result of the different unit conversions and properties used. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 45 8, 12.5, 22.2 0.61 414 8,412 2,156 11,390
-0.25
-0.05 204 1,113 5,741 11,830
REFERENCES:
Hood, J.J. (1962), Heavy Water Moderated Power Reactors, DP-725, E.I. du Pont de Nemours and Company, Wilmington, DE, April 1962, 53 pages.
Babcock, D.F., and R.R. Hood (1962), Heavy Water Moderated Power Reactors, DP-725, E.I. Dupont de Nemours and Company, Wilmington, DE.
56 Hood and Isakoff (1962)
Stainless steel tubing was used in these CHF tests with upward flow. In most cases, the burnout occurred within 1/2 inch (and never more than 7/8 inch) from the downstream end of the heated part of the tube. Burnout was detected primarily by the melting of the tube wall or observation of an incandescent spot on the outside of the tube wall. In some tests, burnout was detected by the change in electrical resistance of the last inch of the heated length. The change in resistance was observed with a null-balance circuit (Wheatstone bridge), which was calibrated during the tests in which the melting of the tube wall occurred.
Only about 50 percent of the measurements were used for the LUT derivation; it is unclear why all the 22.2-mm data and some of the other diameter data were excluded. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 24 8.00 22.2 0.60 1.10 6,895 664 2,726 0.001 0.484 66 1,224 3,186 4,637
REFERENCE:
Hood, J.J., and L. Isakoff (1962), Heavy Water Moderated Power Reactors, DP-755, E.I. du Pont de Nemours and Company, Wilmington, DE, July 1962, 38 pages.
Inasaka and Nariai (1989)
These high-heat flux burnout tests were performed in a 3-mm tube at highly subcooled conditions. The flow was up to 30 megagrams per square meter per second. No CHF detectors were used. The power was increased gradually, and CHF was recorded when the test section melted. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 29 3.00 0.10 290 1,050 4,300 29,900
-0.188
-0.051 266 626 7,300 44,500
REFERENCE:
Inasaka, F., and H. Nariai (1989), Critical Heat Flux of Subcooled Flow Boiling with Water, in the Proceedings of the 4th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), Karlsruhe, Germany, October 10-13, 1989, Volume 1, pp. 115-120.
57 Jafri (1993)
The data were obtained from Jafris doctoral thesis (1993). The data set contains 21 data points for upflow and about 30 data points for downflow. All experimental data refer to the vertical orientation using pure water as a test fluid. The material of test section was Inconel 625 with a wall thickness of 1.65 mm. Eight data points have two phases at the test-section inlet, and the same data points have dryout quality greater than 1; they have been rejected. The table below lists the range of parameters for this data set.
Tube Diameter Heated Length L/D Ratio Pressure Mass Flux Local Quality Inlet Temperature Heat Flux mm m
kPa kg m-2 s-1
°C kW m-2 15.7 2.440 155.414 362 1,060 1,439 7,830 0.0947 1
74.4 265 1,800 5,620
REFERENCE:
Jafri, T.M. (1993), Analysis of Critical Heat Flux for Vertical Round Tubes, Ph.D.
Thesis, Columbia University, New York, NY, 164 pages.
Jens and Lottes (1951)
Jens and Lottes (1951) reported on some very early CHF experiments that were performed in tubes. Table II-V in the report contains the data obtained either at the University of California, Los Angeles (UCLA) (see references below), or at Purdue University by Weatherhead (1950).
The analysis did not use the Weatherhead data. The table below lists the ranges covered by the UCLA experiment.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 48 5.74 0.625 3,448 13,790 1,301.8 10,603.9
-0.464
-0.015 279 1310 2,965.3 11,924.4 70.52 285.05 It is not clear which reference below refers to the UCLA report (Boelter (1949), Gunther (1951),
or McAdams et al. (1948)).
REFERENCES:
Jens, W.H., and P.A. Lottes (1951), Analysis of Heat Transfer Burnout, Pressure Drop and Density Data for High-Pressure Water, ANL-4627, Argonne National Laboratory, Lemont, IL, May 1, 1951, 73 pages.
Boelter, L.M.K., et al. (1949), Boiling Studies, U.S. Atomic Energy Commission Research Contract No. AT-11-1-Gen-9, Progress Report No. 1, U.S. Atomic Energy Commission, Washington, DC, August 1949.
58 Gunther, F.C. (1951), Photographic Study of Surface-Boiling Heat Transfer to Water with Forced Convection, Transactions of the American Society of Mechanical Engineers, Vol. 73, No. 2, pp. 115-123 McAdams, W.H., J.N. Addonas, and W.E. Kennel (1948), Heat Transfer at High Rates to Water with Surface Boiling, ANL-4268, reproduced by Argonne National Laboratory, Lemont, IL, December 1948.
Weatherhead, R. (1950), Thesis in Mechanical Engineering, Purdue University, West Lafayette, IN.
Judd and Wilson (1966)
These experiments were performed as part of a series of tests to examine the effect of axial flux shape. This section reports the uniform axial flux distribution (AFD) data. Thermocouples were attached every 1 inch along the downstream part of the test section. The material of the test section was not specified. The table below lists the ranges of conditions covered by the experiment.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 49 11.30 1.829 6,861 13,859 673.9 3,428 0.016 0.776 33 730 593.1 2,668.8 207.11 323.84
REFERENCE:
Judd, D.F., and R.H. Wilson (1966), Burnout for Flow Inside Round Tubes with Nonuniform Heat Fluxes, BAW-3238-9, Babcock & Wilcox Company, Lynchburg, VA, May 1966, 123 pages.
Kim et al. (2000)
This data set contains 512 CHF data points; however, the author mentions 513 data points.
The test sections were made of vertical Inconel 625 tubes through which the subcooled water flowed upwards. Three K-type thermocouples were brazed to the outer surface of the test section to detect CHF. The table below lists the ranges of flow parameters.
Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Critical Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 6.0 12.0 0.300 1.770 41.7 295.0 104.0 951.0 20.0 277.0 0.323 1.251 120.0 1,598.0 20.5 156.3
59
REFERENCE:
Kim, H.C., W.-P. Baek, and S.H. Chang (2000), Critical Heat Flux of Water in Vertical Round Tubes at Low Pressure and Low Flow Conditions, Nuclear Engineering and Design 199:49-73.
Kirillov (1984, 1985) CHF Reproducibility Study Kirillov et al. (1984) compared the results of a unique collaborative CHF experimental investigation performed at 10 different laboratories in the Union of Soviet Socialist Republics (U.S.S.R.). The objective of this collaboration was to compare the CHF obtained in various experimental test facilities at the same nominal conditions.
All CHF experiments were performed in tubes of Kh18N10T steel (i.e., stainless steel consisting of 18-percent chrome and 10-percent nickel) with an ID of 8 mm and a wall thickness of 2 mm.
The tube lengths were 1, 3, and 6 meters. All 10 participating laboratories used tubes produced from the same batch. The table below lists the test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 2,470 7.71 8.09 0.990 6.000 6,370 18,040 494 4,154
-0.494 0.981 7
1,537 110 7,700 79.41 350.90 This CHF reproducibility exercise was performed during 1981-1983 and yielded about 2,500 experimental values of the CHF power. No precise references for the various laboratories and their results were given. Kirillov et al. (1984, 1985) referred to them as follows:
VTI F.E. Dzerzhinskii, All-Union Heat Engineering Institute (FEI)
I. Polzunov, Central Boiler-Turbine Institute (TsKTI)
V. Kurchatov, Institute of Atomic Energy (IAE)
Institute of Engineering Thermophysics of the Academy of Sciences of the Ukrainian SSR (ITTF)
Special Design Office (SDO) Gidropress NIKIET Scientific-Production Union (SPU) Energiya Kiev Polytechnical Institute (KPI), Ukraine Elektrogorsk Research Station (ENIS)
60 The results show that the spread in CHF power was 16 to 32 percent for the 1-meter heated length and 10 percent for the 3-meter heated length. The spread in CHF on a CHF versus critical quality plot was significantly higher. Additional details of this reproducibility exercise appear in Kirillov (1997). Note that Kirillov and coworkers at the Institute of Physics and Power Engineering (IPPE) in Obninsk originally compiled a CHF database of over 14,000 data points from primarily U.S.S.R. sources (the IPPE database). These data were transferred to UofO around 1992.
The original Kirillov database, which Kirillov transferred to Groeneveld in the early 1990s, consisted of six data sets identified by the original experimenter. The reproducibility exercise data reported here were a subset of the original 14,000 data points from IPPE and were labeled as Kirillov et al., 1984.
REFERENCES:
Kirillov, P.L., O.L. Peskov, and N.P. Serdun (1985), Control Experiment on Critical Heat Transfer during Water Flow in Pipes, Soviet Atomic Energy 57:858-860, Translation from original article by Kirillov et al. in Atomnaya Energiya 57(6):422-423, December 1984.
Kirillov, P.L. (1997), Addendum and comments to the paper titled, 1995 Look-Up Table for Calculating Critical Heat Flux in Tubes, Thermal Engineering 44(10):841-850.
Kirillov Database (1992)
Kirillov and coworkers at the IPPE in Obninsk, Russia, compiled a CHF database of over 14,000 data points from primarily U.S.S.R. sources. These data were transferred to UofO around 1992.
Subsequently, Groeneveld and Kirillov combined their databases, which expanded the total number of data points beyond 29,000. The combined database is referred as the the AECL-UO-IPPE CHF database, which became the basis of the 1996 CHF LUT (Groeneveld et al., 1995).
The database that Kirillov transferred to Groeneveld consisted of six data sets that the original experimenter identified. The table below lists the original experimenters and the number of data points in each subset of Kirillovs database.
Experimenter Number of Data Points Alekseev et al. (1964) 1,108 Zenkevich (1969) 5,641 Zenkevich et al. (1971) 392 Ladislau (1978) 136 Smolin et al. (1979) 3,009 Bergelson (1980) 336 Kirillov et al. (1984) 2,470
61 Some data originating from the U.S.S.R. were already covered in the AECL-UO database and were removed from the Kirillov database. The subset labeled as Kirillov et al., 1984 contains 2,470 data points that were actually obtained by other experimenters (names unknown) as their contribution to the reproducibility exercise described by Kirillov et al. (1984) and Kirillov (1997) and reported above under the section Kirillov (1984, 1985) CHF Reproducibility Study.
REFERENCES:
Groeneveld, D.C., L.K.H. Leung, P.L. Kirillov, V.P. Bobov, I.P. Smogalev, V.N.
Vinogradov, X.C. Huang, and E. Royer (1996), The 1995 Look-Up Table for Critical Heat Flux in Tubes, Nuclear Engineering and Design 163:1-23.
Kirillov, P.L., O.L. Peskov, and N.P. Serdun (1985), Control Experiment on Critical Heat Transfer during Water Flow in Pipes, Soviet Atomic Energy 57:858-860, Translation from original article by Kirillov et al. in Atomnaya Energiya 57(6):422-423, December 1984 Kureta (1997)
These data were extracted from Kuretas doctoral thesis (1997). The data set contains 949 data points with tubes of a small diameter under low-pressure conditions. All experimental data were obtained in a vertical test section with upflow using pure water as a test fluid. Atmospheric pressure is the exit pressure of the test sections. Details on the material of the test section or the method of CHF detection are not available. The table below lists the ranges of conditions covered by the data set.
Tube Diameter Heated Length L/D ratio Pressure Mass Flux Local Quality Heat Flux Inlet Temperature mm mm kPa kg m-2 s-1 kW m-2
°C 1.0 6.0 4.0 680.0 1.0 113.3 101.3 0
19,130
-0.147
> 1.0 35.3 158,100 6.7 100.0 Note that the L/D ratio is sometimes 1, which seems experimentally very difficult to achieve.
The CHF screening tests for acceptable CHF data reject very low L/D data.
REFERENCE:
Kureta, M. (1997), A Data Set of Critical Heat Flux for Flow-Boiling of Water in Small-Diameter Tubes under Low-Pressure Conditions, Kyoto University, Kyoto, Japan, Ph.D. Thesis, Appendix A, 44 pages.
62 Lee (1965)
Lee (1965) experimentally investigated the effect of AFD, wall thickness, heated length, and tube diameter in his experiments. Lees tube diameters varied from 0.364 to 0.464 inch, the wall thickness varied from 0.034 to 0.080 inch, and the heated length varied from 34 to 144 inches. Appendix II of Lees report summarizes the tube diameter and heated length results as follows: 165 tube CHF points are tabulated, all for pressures around 1,000 psia (about 7 MPa). The quality ranges from 0.007 to 0.447, and the mass flux ranges from 1.468x106 to 3.017x106 pounds per hour per square foot.
Lee compared his results to those of Lee and Obertelli (1963) and Kearsey (1964). Appendix IV contains eight data points obtained by Lee and Obertelli (1963) under conditions similar to Lees 1965 study; these data points are part of the dataset described separately under Lee and Obertellli (1963). Appendix V of Lees report contains 52 CHF data points obtained from Kearsey (1964), which were also obtained under similar conditions. The reproducibility of the data is quite good, generally within 3 percent. Kearseys data were not used for development of the 2006 CHF LUT.
Finally, Appendix VI of Lees report tabulated his (1963) CHF data (87 CHF data points),
designed to investigate the wall thickness effect. The effect varies from no effect for the longer length of 68 inches to possibly an 8-percent higher CHF for the thicker wall and for the shorter heated length (34 inches).
Only 37 CHF data points from Lee (1965) were used in the development of the 2006 CHF LUT, while 242 CHF measurements were obtained. The remainder can be used for future LUT updates or for validation of the 2006 CHF LUT. The table below lists the ranges of the Lee (1965) data used for LUT derivation.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 37 9.50 1.73 3.05 6,828 7,024 2,020 5,720 0.002 0.433 75.5 577 1,307 3,873 161 271
REFERENCES:
Lee, D.H. (1965), An Experimental Investigation of Forced Convection Burnout in High-Pressure Water. Part III: Long Tubes with Uniform and Nonuniform Heat Flux, AEEW-R355, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Lee, D.H., and J.D. Obertelli (1963), An Experimental Investigation of Forced Convection Boiling in High Pressure Water, AEEW-R213, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Kearsey, H.A. (1964), Private communication with Lee, D.H.
63 Lee (1966)
Lee (1966) performed several tests with larger diameter tubes (0.554, 0.862, 1.11, and 1.76 inches) at high pressures. The experimental technique was similar to that used by Lee (1965); the test section was equipped with thermocouples acting as CHF detectors. The table below lists the ranges of conditions covered by the CHF experiments.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 435 14.10 44.70 0.635 1.524 8,237 12,579 332.2 3,410.3
-0.110 0.780 60 451 870.7 3,738.2 259.80 318.09
REFERENCE:
Lee, D.H. (1966), An Experimental Investigation of Forced Convection Burnout in High-Pressure Water. Part IV: Large Diameter Tubes at about 1,600 P.S.I.,
AEEW-R479, Atomic Energy Research Establishment, Winfrith, Dorchester, Dorset, United Kingdom, November 1966, 70 pages.
Lee, D.H. (1965), An Experimental Investigation of Forced Convection Burnout in High-Pressure Water. Part III: Long Tubes with Uniform and Nonuniform Heat Flux, AEEW-R355, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Leung (1989)
Leung (1989) obtained these data as part of his doctoral thesis research. He did not report them in his thesis (Leung, 1994), but the thesis refers to these CHF tests, and the geometry of his thesis experiments corresponds exactly to this geometry. The table below lists the range of test conditions.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 66 5.45 2.511 5,030 9,710 1,167.6 9,938.3 0.210 0.578 6
316 656.2 3,058.3 227.85 305.33
REFERENCE:
Leung, L.K.H. (1994), A Model for Predicting the Pressure Gradient along a Heated Channel during Flow Boiling, Ph.D. Thesis, Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.
64 Leung et al. (1990)
The Leung et al. (1990) data were used to derive the 2006 CHF LUT. Because of the restricted distribution of this data, the test parameters and CHF data are not included here.
It is suspected that the data for this experiment came from the following reference, which has a restricted distribution.
REFERENCE:
Leung, L.K.H., S.T. Yin, and J. Martin (1990), Measurements of Critical Heat Flux, Post-Dryout Pressure Drops and Wall Temperature in Tubes, COG-90-32 (also ARD-TD-227), Restricted Distribution.
Lowdermilk et al. (1958)
The purpose of this CHF experiment was to investigate the effects of flow-system characteristics on flow stability and burnout. An open-cycle or once-through flow system was chosen, and the flow was restricted upstream from the test section and discharged into a compressible volume at the exit of the test section. With this system, flow stability and burnout can be defined by determining the pressure drop across the flow restriction in addition to usual burnout variables, such as flow rate, pressure, temperature, and tube geometry.
The test sections were made of Type 347 stainless steel. Figure A-1 shows the test-section schematic with the power clamp location. The table below lists the dimensions of the test section.
Inside Diameter (mm)
Heated Length/Diameter Ratio Unheated Length/Diameter Ratio Wall Thickness (mm)
Wall Thickness/Inside Diameter Ratio 1.30 50, 100, 150, 200, 250 7.3 0.84 0.65 1.30 250 7.3 1.88 1.45 1.93 50, 100, 150, 200, 250 4.9 1.02 0.53 2.44 50, 100, 150, 200, 250 3.9 1.45 0.59 3.12 25, 50, 100, 150, 200, 250 3.0 1.65 0.53 3.96 25, 50, 100, 150, 200, 250 2.4 1.22 0.31 4.76 25, 50, 100, 150, 200, 250 2.0 2.37 0.50 The test sections were polished before their installation. For the majority of the runs conducted, the heated length of the test section was varied by using the 250 L/D (length-diameter) sections and by clamping the inlet electric power supply cable at the desired location along the tube length, as shown in Figure A-1. In the experimental runs using a preheater, the preheater power supply cables were connected across the length of the tube that was not being heated by the main power supply, as shown in Figure A-1.
65 The data shown in Tables I and II in Lowdermilk et al. (1958) should not be used in future LUT derivations/validations because, respectively, they correspond to the effect of a compressible volume and the effect of a flow restriction at the inletboth of which were found to have a strong effect on CHF. The maximum values of the burnout heat flux were obtained for a stable flow by restricting the flow upstream from the test section. The minimum pressure drop across the restriction required to stabilize the flow increased from 5 to 100 pounds per square inch (psi) when the inlet flow velocity was increased from 0.5 to 40 feet per second.
In addition, a compressible volume introduced in the flow system between the flow restriction and the inlet of the test section resulted in unsteady flow during burnout. The flow fluctuations increased, and the burnout heat flux decreased with an increase in the compressible volume.
Figure A-1 Test section Details in Lowdermilk et al. (1958)
The table below lists the range of test conditions suitable for LUT derivation.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 470 4.00 4.80 0.119 0.991 100 27.2 4,865.5 0.030 1.236 317 331 167 9,525 20.91 24.24 For the 2006 LUT derivation, only 112 CHF data points were usedthe data with small diameters (D < 4 mm) and short lengths (L/D < 50) were excluded.
66
REFERENCE:
Lowdermilk, W.H., C.D. Lanzo, and B.L. Siegel (1958), Investigation of Boiling Burnout and Flow Stability for Water Flowing in Tubes, NACA-TN-4382, National Advisory Committee for Aeronautics (NACA), Cleveland, OH, September 1958, 52 pages.
Matzner et al. (1965)
Matzner et al. (1965) performed CHF experiments at Columbia University on an Inconel tube with vertical upflow. The test section was equipped with thermocouples at the downstream end to detect CHF occurrence. As extra protection, the test section was also used as one leg of a Wheatstone bridgean imbalance in the bridge circuit was indicative of CHF occurrence. The table below lists the ranges of conditions covered by the CHF experiments.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 99 10.20 2.438 4.877 6,893 1,193.3 9,559.8 0.008 0.693 48 1,183 643.5 4,041 65.61 275.82
REFERENCE:
Matzner, B., E.O. Moeck, J.E. Casterline, and G.A. Wikhammer (1965), Critical Heat Flux in Long Tubes at 1,000 psi with and without Swirl Promoters, Paper 65-WA/HT-30, AECL-2446, Proceedings of the American Society of Mechanical Engineers, 16 pages.
Mayinger et al. (1966)
The purpose of this CHF experiment was to study the effects of upstream history and the inlet conditions, as well as the L/D ratio of the test channel. The tests were made at pressures of 70 to 140 kilogram-force per square centimeter using internally cooled tubes with diameters varying from 0.7 to 1.5 cm. The conditions at the test channel inlets covered mass flows between 100 and 350 grams per square centimeter per second using either a subcooled inlet or two-phase inlet (up to 20 percent).
The two types of burnout observed are completely different in their physical appearance. One type is characterized by the occurrence of fluctuations in the pressure and mass flow shortly before film boiling starts; this was designated as pulsating burnout. The other type shows a hydrodynamically completely stable behavior until film boiling suddenly occurs. Pulsating burnout (observed only at subcooled boiling conditions) was found to lead to critical heat flux levels 20 to 50 percent below those obtained with hydrodynamically stable flow. An even greater influence on the CHF was obtained by a reduction of the L/D ratio. With very short test sections with an L/D ratio of 5 to 10, the critical heat flux is 4 to 5 times the value obtained with long test channels with an L/D ratio of 80 to 100. The table below lists the ranges of conditions covered by the CHF experiments.
67 No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 128 7.00 0.560 0.980 1,925 10,244 2,233 3,734 0.098 0.405
-239 314 924 5,618 233.28 310.09
REFERENCE:
Mayinger, F., O. Schad, and E. Weiss (1966), Untersuchung der kritischen Heizflachenbelastung (Burnout) bei sieden dem Wasser (Translation: Investigation into the Critical Heat Flux in Boiling), 09.03.01, Maschinenfabrik Augsburg-Nurnberg AG, Munich, Germany, May 1966, 265 pages.
Nariai et al. (1987)
The Nariai et al. (1987) data were obtained in small diameter tubes (1, 2, and 3 mm) under high flow and at near-atmospheric pressure. This paper does not report the data, which were obtained separately. Only seven data points were used for the 2006 CHF LUT derivation. The table below lists the ranges of conditions covered by the CHF experiments.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 93 1.00 3.00 0.009 0.101 100 6,710 20,910
-0.134 0.007 149.5 353 4,647 69,990 15.4 64
REFERENCE:
Nariai, H., F. Inasaka, and T. Shimura (1987), Critical Heat Flux of Subcooled Flow Boiling in Narrow Tubes, in the Proceedings of the 1987 American Society of Mechanical Engineers/Japan Society of Mechanical Engineers Thermal Engineering Joint Conference, Honolulu, HI, March 22-27, 1987, P.J. Marto and I. Tanasawa (Eds.),
American Society of Mechanical Engineers, New York, NY, Volume 5, pp. 455-462.
Nariai CHF Data Set from Celata (2001)
The data were contained in 2001 from a personal communication from G.P. Celata to UofO.
Celata had received data directly from Nariai. This data set contains 14 data points. Details of the experiment are not known. The table below lists the ranges of flow parameters.
68 Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Critical Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 6.0 0.100 16.6 100.0 1,500.0 4,590.0 8,690.0
-0.2596 0.0577 8,500.0 22,100.0 38.3 44.7
REFERENCE:
Personal communication between G.P. Celata and Professor S.C. Cheng, University of Ottawa, Ottawa, Ontario, Canada, April 22, 1993.
Nguyen and Yin (1975)
CHF tests were performed in an Inconel 600 tube with an ID of 0.496 inch. Measurements were obtained with the test section in both the vertical and horizontal positions (this paper reports only the vertical tube CHF data). CHF was detected using Type K thermocouples. The table below lists the ranges of conditions covered by the CHF experiments.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 56 12.60 2.438 4.877 6,645 8,401 929.6 3,838.4 0.216 0.738 52 413 677 2,023.7 225.06 276.81
REFERENCE:
Nguyen, D.M., and S.T. Yin (1975), An Experimental Investigation of Water Critical Heat Flux in a Tubular Channel in Both Horizontal and Vertical Attitudes, Technical Memorandum CWTM-013-HT, Westinghouse Canada Limited, Toronto, Canada, December 1975, 39 pages.
69 Olekhnovitch (1997)
The electronic copy of this data set was obtained from private communications between D.C.
Groeneveld and A. Olekhnovitch. Olekhnovitch et al. (1999) and Olekhnovitch (1997) later described details of the experiment for the same data set. This data set contains 479 data points. The test sections consisted of vertical, uniformly heated tubes through which the water flowed vertically upwards. The Inconel 600 tubes had a wall thickness of either 1 mm or 2 mm.
To detect the dryout occurrence, 30 chromel-alumel thermocouples were spot welded on the surface of the tube. The table below lists the ranges of flow parameters.
Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Critical Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 8.0 0.750 3.500 93.8 437.5 507.0 4,036.0 977.0 6,122.0 0.0460 0.7610 523.0 5,550.0 47.2 2
44.5 REFERENCES
Olekhnovitch, A. (1997), Etude de Flux de Chaleur Critique a des Pressions Faibles, Universite de Montreal, Montreal, Quebec, Canada, Ph.D. Thesis, October 1997, 599 pages.
Olekhnovitch, A., A. Teyssedou, A. Tapucu, P. Champagne, and D.C. Groeneveld (1999), Critical Heat Flux in Vertical Tube at Low and Medium Pressures. Part I:
Experimental Results. Nuclear Engineering and Design 193:73-89 Olekhnovitch, A., A. Teyssedou, and P. Tye (1999), Critical Heat Flux in Vertical Tube at Low and Medium Pressures. Part II: New Data Presentation. Nuclear Engineering and Design 193:91-103.
Pabisz and Bergles (1996)
Pabisz and Bergles (1996) investigated the effect of additives on CHF. The data reported here are the 10 reference tests that measured the CHF in a directly heated tube; six of these tests were used as a database for the derivation of the 2006 CHF LUT. The tubes were made of stainless steel, and CHF was defined as the heat flux where actual burnout (i.e., tube failure) occurred. The table below lists the ranges of conditions covered by the CHF experiments.
Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 4.40 6.20 0.11 0.154 627 1,284 2,417 4,994
-0.196
-0.133 567 698 7,370 13,880 15.3 46
70
REFERENCE:
Pabisz, R.A., Jr., and A.E. Bergles (1996), Enhancement of Critical Heat Flux in Subcooled Flow Boiling of Water by Use of a Volatile Additive, in the Proceedings of the American Society of Mechanical Engineers Heat Transfer Division (HTD), Presented at the 1996 International Mechanical Engineering Congress and Exposition, Atlanta, GA, November 17-22, 1996, HTD-Volume 334, Volume 3, pp. 305-312.
Peterlongo et al. (1964)
Peterlongo et al. (1964) obtained data for upward flow of steam-water mixtures in round vertical tubes. The data set contains 351 data points without obstacles and additional data points with internal obstacles. The test sections were seamless AISI Type 304 stainless steel tubes with a length of 4.996 meters. CHF was detected by nickel-nickel/chrome thermocouples attached to the heated tube. For subcooled or low-quality conditions, CHF was of the departure from nucleate boiling type, characterized by a sharp increase in temperature for a small increase in heat flux. However, for higher qualities, the CHF was more of a slow dryout type. Here, the wall temperature rise was plotted against heat flux (i.e., the boiling curve), and CHF was defined as a sharp decrease in the slope of a heat flux versus wall temperature plot. The table below lists the ranges of test conditions covered by the tests.
Tube Diameter Tube Length Heated Length Pressure Mass Flux Local Quality Heat Flux Inlet Temperature mm m
m kPa kg m-2 s-1 kW m-2
°C 15.1 15.2 4.996 1.6 4.116 4,982 6,551 1,080 3,910
-0.023 0.608 895 4,115 26.15 280.47
REFERENCE:
Peterlongo, G., R. Ravetta, B. Riva, L. Rubiera, and F.A. Tacconi (1964), Large Scale Experiments on Heat Transfer and Hydrodynamics with SteamWater Mixtures: Further Critical Power and Pressure Drop Measurements in Round Vertical Tubes with and without Internal Obstacles, R-122, Centro Informazioni Studi Esperienze (CISE),
Segrate, Milan, Italy.
Rudzinski et al. (1999)
This experiment was performed as part of an investigation to examine the effect of flow, pressure, and heat flux transients on CHF. Only the reference steady-state tests are reported here. Because of the restricted distribution of this data, the test parameters and CHF data are not included here.
71
REFERENCE:
Rudzinski, K.F., D.C. Groeneveld, and S. Doerffer (1999), Analysis of the Flow Transient CHF and Rewetting Data Obtained in an 8 mm Tube, FFC-FCT-65, COG-96-510, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada, February 1999, 142 pages. Restricted Distribution.
Shan (2005)
Shan (2005) was assisting in the UofO LUT development work before 2005. He identified some CHF tube data that were labeled as Col-U (Columbia University). This data set was based on both 8-mm and 15.82-mm-ID tube test sections. No source for these data could be found. The table below lists the ranges of conditions covered by the CHF experiments used in the derivation of the 2006 LUT.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Heat Flux Number Mm m
kPa kg m-2 s-1 kW m-2 24 8.00 15.82 1.00 2.4384 317 14,808 572 8,015
-0.022 0.422 819.5 5,691 Smolin et al. (1962)
The Smolin et al. (1962) reference for these data does not seem to correspond to the experimental data because it refers to 8-mm data that were obtained only at P = 150 atmospheres. The 1962 experiment was performed in a 2.6-meter-long heated test section where the flow was slowly reduced for a fixed heat flux until a temperature rise of about 10 to 15 degrees Kelvin was detected by the thermocouples welded to the test-section wall near the downstream end of the heated length. (See also the reference to Smolins work in Zenkevich (1974)). The table below lists the test conditions.
REFERENCES:
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1962), On the Heat Transfer Crisis in Steam-Generating Pipes, Soviet Journal of Atomic Energy 13:968-972, Translation from Atomnaya Energiya 13(4):360-364.
Groeneveld, D.C., L.K.H. Leung, P.L. Kirillov, V.P. Bobov, I.P. Smogalev, V.N.
Vinogradov, X.C. Huang, and E. Royer (1996), The 1995 Look-Up Table for Critical Heat Flux in Tubes, Nuclear Engineering and Design 163:1-23.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number Mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 369 3.84 10.80 0.776 4.000 7,840 19,610 498 7,556
-0.132 0.795 5
1,329 230 5,652 140.35 350.39
72 Smolin (1979)
The Smolin (1979) data came from the database transferred by Kirillov to UofO around 1992 and described above under the section titled, Kirillov Database (1992). No documentation was provided. Smolins experiment may have been similar to an earlier experiment by Smolin, as reported in Smolin (1962). The table below lists the test conditions.
REFERENCE:
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1962), On the Heat Transfer Crisis in Steam-Generating Pipes, Soviet Journal of Atomic Energy 13:968-972, Translation from Atomnaya Energiya 13(4):360-364.
Snoek (1988)
The Snoek (1988) experiment was designed to investigate the effect of subchannel shape on CHF. The original report is proprietary to AECL and not available to the public, so the test parameters and CHF data are not included here.
REFERENCE:
Snoek, C.W. (1988), Comparison of the Critical Heat Flux in Interconnected Subchannels of Different Geometry, Internal Report CRNL-4231, CANDEV-88-23, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada, December 1988.
Soderquist (1994)
The electronic copy of this large data set was obtained directly from the author, B. Soderquist, from the Department of Nuclear Reactor Engineering, Royal Institute of Technology, Stockholm, Sweden, and was also made available at an anonymous FTP site. The electronic version contains 1,485 data points. Subsequently, a printed copy of the data and experimental details were received as well. It refers to 1,485 data points that were obtained although the printed copy only contains 1,410 data points. Data points 1411-1485 are missing from the printed version; however, because the first 1,410 data points are the same as in the electronic copy, it is believed that the data points 1411-1485 were obtained in the same manner. The data set also contains 110 CHF data points with quality greater than 1, an obvious impossibility. These X > 1.0 data were all obtained at low flows (G ~ 250 kg m-2 s-1). This suggests that the low-flow data may not be reliable, even though the author quotes errors of 1 percent in pressure, 0.8 percent in mass flux, and 0.5 percent in power. The heat balances for the single-phase flow were within 1 percent. The table below lists the ranges of parameters.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 2,987 3.84 16.00 0.690 6.050 2,940 17,710 490 7,672
-0.136 0.789 4
1,362 245 5,626 72.72 351.65
73 Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Critical Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 7.98 8.11 1.000 6.000 123.3 751.9 970.0 20,120.0 243.0 6,085.0
-0.169 1.00 50.0 3,879.0 118.3 356.9 The test-section material was stainless steel. Because stainless steel has a high-temperature coefficient of resistance compared to Inconel, the true heat flux at the downstream end will be higher than the reported average heat flux.
REFERENCE:
Soderquist, B. (1994), Swedish CHF Data, Department of Nuclear Reactor Engineering, Royal Institute of Technology, Stockholm, Sweden, Personal communication with D.C. Groeneveld (received from Soderquist in March 1994).
Swenson et al. (1962)
Swenson et al. (1962) obtained the data. The data set contains 25 data points with uniform heat flux distribution and other data points with three nonuniform axial heat flux distributions.
The test sections were seamless AISI Type 304 stainless steel tubes with a length of 2.9464 meters (116 inches) and an ID that varied from 10.44 to 11.33 mm (0.411 to 0.446 inch).
The tubes are installed vertically with the flow upward. The intermediate 1.8288-meter (72-inch) length was heated electrically. The table below lists the ranges of conditions covered by the data set.
Tube Diameter Heated Length Pressure Mass Flux Local Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 10.44 10.54 1.8288 13,790 678.7 1,764.7 0.178 0.502 586.83 1,063.24 231.4 329.4
REFERENCE:
Swenson, H.S., J.R. Carver, and C.R. Kakarala (1962), The Influence of Axial Heat-Flux Distribution on the Departure from Nuclear Boiling in a Water-Cooled Tube, Paper No. 62-WA-297, American Society of Mechanical Engineers, New York, NY, 15 pages.
Tian (1994)
The reference or documentation could not be located. The data are from a private communication.
74 Tong (1964)
No documentation could be found for this set of data. The table below lists the ranges of conditions covered by the CHF data set.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 266 6.22 12.90 0.380 3.660 5,171 13,790 678 14,002 0.002 0.502 5
1,060 587 6,139 263.94 330.85
REFERENCE:
No reference.
Waters et al. (1965)
This data set contains 38 data points. The test section consisted of a vertical, uniformly heated Inconel tube with a 4.8-mm wall thickness through which the water flowed upwards. The 20 thermocouples spot welded to the outer surface of the tube at 30.5-cm axial intervals were used as burnout detectors. This experiment showed that the initial CHF occurrence with a uniform AFD can occur at upstream locations, especially at high flows. The dryout quality, the inlet temperature, and the inlet subcooling enthalpy have been calculated by the enthalpies given in the papers. The table below lists the ranges of flow parameters.
Tube Diameter Heated Length Pressure Mass Flux Inlet Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 11.2 3.658 6,894.76 10,342.14 6,645.53 9,547.86
-0.0335 0.3218 2,016.92 5,388.95 86.93 313.48
REFERENCE:
Waters, E.D., J.K. Anderson, W.L. Thorne, and J.M. Batch (1965), Experimental Observations of Upstream Boiling Burnout, Chemical Engineering Progress Symposium Series 61(57):230-237.
Whittle and Forgan (1967)
This data set contains 59 data points. The vertical test sections consisted of a rectangular channel and a single, uniformly heated round tube through which subcooled water flowed upwards. The distinctiveness of this test procedure was that, for a fixed power, the flow rate was reduced from a maximum value while the test-section pressure drop was monitored carefully. The flow rate that corresponded to the minimal pressure drop is related to the CHF occurrence. The table below lists the ranges of flow parameters.
75 Tube Diameter Heated Length Pressure Mass Flux Inlet Quality Heat Flux Inlet Temperature mm M
kPa kg m-2 s-1 kW m-2
°C 6.45 0.4064 0.6096 117.2 172.4 1,643.5 9,137
-0.03105
-0.00879 660 3,480 35 75
REFERENCE:
The reference to this data set may be in the following article:
Whittle, R.H., and R. Forgan (1967), A Correlation for the Minima in the Pressure Drop versus Flow-Rate Curves for Subcooled Water Flowing in Narrow Heated Channels, Nuclear Engineering and Design 6:89-99.
Williams and Baus (1980) (CHF data set from the Zummo database)
The electronic copy of this data set was extracted from the Zummo CHF database. The database was obtained in personal communication between G. Zummo, K. Mishima, and Y.
Guo, and D.C. Groeneveld. The original paper by Williams and Baus (1980) became available later and confirms the validity of the data. This data set contains 129 data points. All experimental data are for a vertical tube with upflow using water as a test fluid. The test section was made of Type 304 stainless steel. The table below lists the ranges of parameters for this data set.
Tube Diameter Heated Length Lh/D ratio Pressure Mass Flux Local Quality Heat Flux Inlet Temperature mm m
kPa kg m-2 s-1 kW m-2
°C 9.5 1.840 193.6842 2,758 15,169 324 4,662
-0.025 0.929 388 4,073 90 315
REFERENCE:
Williams, C.L., and S.G. Baus (1980) Critical Heat Flux Experiments in a Circular Tube with Heavy Water and Light Water, WAPD-TM-1462, Bettis Atomic Power Laboratory, West Mifflin, PA, May 1980.
Yin et al. (1988)
Yin et al. (1988) performed CHF tests in a 13.4-mm-ID tube (with a wall thickness of 1.24 mm) made of Inconel 600 using only one nominal mass flux of 2,030 kg m-2 s-1. The test section was equipped with multiple chromel-alumel thermocouples that served as dryout detectors. The table below lists the ranges of conditions covered by the CHF experiments.
76 No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 287 13.40 3.658 1,028 21,197 1,938.9 2,081.6 0.075 0.431 0
493 583.3 1,863.7 128.42 358.41
REFERENCE:
Yin, S.T., T.-J. Liu, Y.-D. Huang, and R.M. Tain (1988), Measurements of Critical Heat Flux in Forced Flow at Pressures Up to the Vicinity of the Critical Point of Water, in the Proceedings of the 1988 National Heat Transfer Conference, Houston, TX, July 24-27, 1988, Volume 2, pp. 501-506.
Zenkevich (1971)
The data were attributed to Kirillovs database (see the section Kirillov Database (1992)) that was transferred to the UofO in the early 1990s). The 392 CHF were used for the 2006 LUT derivation. Details of the test section and the method of CHF detection are not available. The table below lists the ranges of conditions covered by the CHF data set.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number Mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 392 7.80 8.05 7.000 20.000 6,860 17,650 1,008 2,783 0.262 0.876 18 1,549 47 1,283 81.96 352.22
REFERENCE:
There is no direct reference; the only indirect reference is from Kirillovs 1992 CHF database.
Zenkevich, Peskov, and Subbotin (1964) CHF Data Set This data set contains 67 points. The test section consisted of tubes of 1Cr18Ni9Ti stainless steel with uniformly heated walls 0.75 to 1.5 mm thick. The table below lists the ranges of flow parameters.
Tube Diameter Heated Length Pressure Mass Flux Inlet Quality Heat Flux Inlet Temperature Mm mm kPa kg m-2 s-1 kW m-2
°C 6.8, 8, and 10 100 666 3,924 9,810 550 6,444.5
-0.01971 0.66008 5,000 9,710 211.02 286.39 Only one point was used for the 2006 CHF LUT derivation.
77
REFERENCE:
Zenkevich, B.A., O.L. Peskov, and N.D. Subbotin (1964), A Study of Critical Heat Flux Densities for Tubular Fuel Elements at Atomic Power Stations, Teploenergetika (in Russian) 11(6):20-22, Thermal Engineering (English translation) 11(6):23-25.
Zenkevich CHF data (1969)
A reference for these data could not be found. They were included in the data compilation of Kirillov that was transferred to the UofO in the early 1990s (see the section Kirillov Database (1992)). Details of the test section and the method of CHF detection are not available. The table below lists the ranges of conditions covered by this CHF data set.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux number mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2 5,595 3.99 15.10 0.250 6.000 5,880 19,610 498 9,876
-1.652 0.964 2
1,644 136 14,760 Zenkevich (1974)
The translation of Zenkevich (1974) is a very large report (over 400 pages) and contains about 7,000 CHF data points, many of which were obtained in uniformly heated tubes; the author obtained about 650 of these data points. This valuable resource provides an excellent summary of data obtained in the U.S.S.R. and elsewhere. The translation also includes additional data sets obtained by seven different authors. With the exception of the Smolin et al. (1962, 1964, 1965) data, these additional data were known and have already been tabulated. The odd-numbered tables between Tables 16 and 35 contain CHF data obtained in tubes but with a nonuniform AFD and should be ignored. Table 1 provides the ranges of conditions covered by 31 pre-1974 CHF data known by Zenkevich, some of which had a two-phase inlet. The table below lists the ranges of conditions covered by Zenkevichs tabulation of the CHF data points, which were obtained in uniformly heated tubes and used for the 2006 LUT derivation.
No. of Data Points Tube Diameter Heated Length Pressure Mass Flux Critical Quality Inlet Subcooling Heat Flux Inlet Temperature number Mm m
kPa kg m-2 s-1 kJ kg-1 kW m-2
°C 823 4.80 12.60 1.000 6.000 5,890 19,620 497.2 6,694.4
-0.221 0.969 5
1,381 230 4,740 96.70 358.24 A difference exists between the number of data points in the report attributed to Zenkevich (about 650) and the number of data points attributed to Zenkevich in the database used to derive the 2006 LUT (823).
78
REFERENCES:
Zenkevich, A., O.L. Peskov, G.A. Petrishcheva, N.D. Sergeev, and V.I. Subbotin.
(1974), Analysis and Generalization of Experimental Data on Heat Transfer Crisis Associated with Forced Convection of Cooling Water in Tubes, AECL-Tr-Misc.-304, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada.
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1962), Heat-Transfer Crisis in a Steam-Generating Tube, Atomnaya Energiya 14(4):360-364.
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1964), Experimental Investigation of Heat-Transfer Crisis, Atomnaya Energiya 16(5):417-423.
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1965), Trudy (Proceedings) of the NPO Tsentralny kotloturbinny institut (TsKTI), No. 58.
79 APPENDIX B REFERENCES TO CRITICAL HEAT FLUX DATA SETS FOR WATER-COOLED TUBES B-1 References to Critical Heat Flux Data Sets Used To Derive the 2006 Critical Heat Flux Lookup Table Alekseev, G.V., B.A. Zenkevich, O.L. Peskov, O.V. Remizov, N.D. Sergeev, and V.I. Subbotin (1964), Kriticheskie Teplovie Potoki pri Vhyzdennom Techenii Vodi (in Russian), Burn-Out Heat Fluxes under Forced Water Flow, A/CONF.28/P/327a, 3rd United Nations International Conference on the Peaceful Uses of Atomic Energy, International Atomic Energy Agency, Vienna, Austria, pp. 295-304.
Alessandrini, A., G. Peterlongo, and R. Ravetta (1963), Large Scale Experiments on Heat Transfer and Hydrodynamics with Steam-Water Mixtures: Critical Heat Flux and Pressure Drop Measurements in Round Vertical Tubes at the Pressure of 51 kg/cm2 abs., CISE-R-86, Centro Informazioni Studi Esperienze (CISE), Milan, Italy, United States/European Atomic Energy Community Joint Research and Development Program, EURAEC-951, December 1963, 66 pages.
Babarin, V.P., R.I. Sevast'yanov, and I.T. Alad'yev (1969), A Special Hydrodynamic Effect on the Boiling Crisis in Tubes, Heat TransferSoviet Research 1(4):34-41, July 1969.
Babcock, D.F., and R.R. Hood (1962), Heavy Water Moderated Power Reactors, DP-725, E.I.
Dupont de Nemours and Company, Wilmington, DE.
Baek, W.-P. (2001), Korean Advanced Institute of Science and Technology, Yusong-gu, Taejon, Korea, Personal communication through e-mail with D.C. Groeneveld, April 20, 2001.
Bailey, N.A., and D.H. Lee (1969), An Experimental and Analytical Study of Boiling Water at 2,000 to 2,600 psi, Part I: Dryout and Post-Dryout Heat Transfer, AEEW-R 659, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Bailey, N.A. (1977), Dryout and Post-Dryout Heat Transfer at Low Flow in a Single Tube Test Section, AEEW-R 1068, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Becker, K.M. (1970), December, Burnout Measurements in Vertical Round Tubes, Effect of Diameter, TPM-RL-1260, Aktiebolaget Atomenergi, Teknisk PM, Stockholm, Sweden, December 1970, 16 pages.
Becker, K.M., P. Persson, L. Nilsson, and O. Eriksson (1963), Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Round Ducts (Part 2), AE-114, Aktiebolaget Atomenergi, Stockholm, Sweden, December 1970, 34 pages.
Becker, K.M., O. Hernborg, M. Bode, and O. Eriksson (1965), Burnout Data for Flow of Boiling Water in Vertical Round Ducts, Annuli and Rod Clusters, AE-177, Aktiebolaget Atomenergi, Stockholm, Sweden.
80 Becker, K.M., G. Strand, D. Djursing, D. Eklind, K. Lindberg, and C. sterdahl (1971), Round Tube Burnout Data for Flow of Boiling Water at Pressures Between 30 and 200 bar, KTH-NEL-14, Royal Institute of Technology, Stockholm, Sweden, 41 pages.
Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1965), Measurements of Burnout Heat Flux in Uniformly Heated Round Tubes at 1,000 psia, AERE-R 5055, Atomic Energy Research Establishment, Harwell, Berkshire, United Kingdom, November 1965, 28 pages.
Bergelson, B.R., (1980), Burnout under Conditions of Subcooled Boiling and Force Convection, Thermal Engineering 27m(1m):48-50, Translated from Teploenergetika 27(1):
58-61.
Bergles, A.E. (1963), Subcooled Burnout in Tubes of Small Diameter, Paper No. 63-WA-182, American Society of Mechanical Engineers (ASME) Winter Annual Meeting, Philadelphia, PA, November 17-22, 1963.
Borodin, A.S., and I.P.L. Macdonald (1983), Separate Measurements of Light Water (H2O) and Heavy Water (D2O) Flow Boiling Critical Heat Flux in a Vertical Cylindrical Tube Geometry, CRNL-2538, Atomic Energy of Canada Limited (AECL), Chalk River, Ontario, Canada, June 1983, 284 pages.
Burck, E., and W. Hufschmidt (1965), Measurement of the Critical Heat-Flux-Density of Subcooled Water in Tubes at Forced Flow, EUR 2432.d, Australian Atomic Energy Commission, Research Establishment, Sydney, Australia, Translated by J.B. Hopkinson, July 1969, LIB/TRANS 210, 40 pages.
Celata, G.P., M. Cumo, and A. Mariani (1992a), CHF in Highly Subcooled Flow Boiling with and without Turbulence Promoters, Paper C1, European Two-Phase Flow Group Meeting, Stockholm, Sweden, June 1-3, 1992, 14 pages.
Celata G.P., M. Cumo, and A. Mariani (1992b), Subcooled Water Flow Boiling CHF with Very High Heat Fluxes, Revue Générale de Thermique 31(362):106-114.
Celata, G.P., and A. Mariani (1993), G.P. Celata transferred Celata and Marianis database to the University of Ottawa (see also the personal communication letter between Celata and Professor S.C. Cheng of the University of Ottawa, Ottawa, Canada, April 22, 1993).
Celata, G.P., M. Cumo, and A. Mariani (1993), Burnout in Highly Subcooled Water Flow Boiling in Small Diameter Tubes, International Journal of Heat and Mass Transfer 36(5):1269-1285.
Cheng, S.C., K.T. Poon, P. Lau, K.T. Heng, T. Doan, and C.Y. Chan (1983), CHF Experiments and Construction of CHF Table, University of Ottawa, Ottawa, Canada, AECL Contract, 1st Progress Report, July 1982-March 1983.
Cheng, S.C., K.T. Poon, T. Doan, S.K. Chin, and Y.M. Koo (1983), CHF Experiments and Construction of CHF Table, Report No. 2, University of Ottawa, Ottawa, Canada, AECL Contract, December 1983.
81 Dell, F.R., G.F. Hewitt, R.K.F. Keeys, and R.A. Stinchcombe (1969), Burnout Heat Flux Measurements in a Long Tube, AERE-M 2216, Atomic Energy Research Establishment, Harwell, United Kingdom, June 1969, 16 pages.
Doerffer, S. (1997), AECL, Chalk River, Ontario, Canada, personal communication with D.C.
Groeneveld; Rudzinski, K.F., D.C. Groeneveld, and S. Doerffer (1999), Analysis of the Flow Transient CHF and Rewetting Data Obtained in an 8-mm Tube, FFC-FCT-65, COG-96-510, AECL, Chalk River, Ontario, Canada, February 1999, 142 pages.
Doerffer, S. (1999), Effect of Flow Orientation on CHF in Smooth Tubes, AECL unpublished report, personal communication with D.C. Groeneveld.
Era, A., G.P. Gaspari, A. Hassid, A. Milani, and R. Zavattarelli (1966), Heat Transfer Data in the Liquid Deficient Region for Steam-Water Mixtures at 70 kg/cm2 Flowing in Tubular and Annular Conditions, CISE-R-184, CISE, Milan, Italy, June 1966, 108 pages.
Griffel, J. (1965), Forced Convection Boiling Burnout for Water in Uniformly Heated Tubular Test Sections, NYO-187-7, U.S. Atomic Energy Commission, Washington, DC, 191 pages.
Groeneveld, D.C. (1985), AECL internal unpublished report.
Hewitt, G.F., H.A. Kearsey, P.M.C. Lacey, and D.J. Pulling (1965), Burnout and Film Flow in the Evaporation of Water in Tubes, AERE-R 4864, Atomic Energy Research Establishment, Harwell, United Kingdom, March 1965, 58 pages.
Hood, J.J., and L. Isakoff (1962), Heavy Water Moderated Power Reactors, DP-755, E.I. du Pont de Nemours and Company, Wilmington, DE, July 1962, 38 pages.
Hood, J.J. (1962), Heavy Water Moderated Power Reactors, DP-725, E.I. du Pont de Nemours and Company, Wilmington, DE, April 1962, 53 pages.
Inasaka, F., and H. Nariai (1989), Critical Heat Flux of Subcooled Flow Boiling with Water, in the Proceedings of the 4th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), Karlsruhe, Germany, October 10-13, 1989, U. Muller, K. Rehme, K. Rust, and G.
Braun (Eds.), Volume 1, pp. 115-120, October 1989.
Jafri, T.M. (1993), Analysis of Critical Heat Flux for Vertical Round Tubes, Ph.D. Thesis, Columbia University, New York, NY, 164 pages.
Jens, W.H., and P.A. Lottes (1951), Analysis of Heat Transfer Burnout, Pressure Drop and Density Data for High-Pressure Water, ANL-4627, Argonne National Laboratory, Lemont, IL, May 1, 1951, 73 pages.
Judd, D.F., and R.H. Wilson (1966), Burnout for Flow Inside Round Tubes with Nonuniform Heat Fluxes, BAW-3238-9, Babcock & Wilcox Company, Lynchburg, VA, May 1966, 123 pages.
Kim, H.C., W.-P. Baek, and S.H. Chang (2000), Critical Heat Flux of Water in Vertical Round Tubes at Low Pressure and Low Flow Conditions, Nuclear Engineering and Design 199:49-73.
82 Kirillov, P.L., O.L. Peskov, and N.P. Serdun (1985), Control Experiment on Critical Heat Transfer during Water Flow in Pipes, Soviet Atomic Energy 57:858-860, Translated from Atomnaya Energiya 57(6):422-423, December 1984.
Kureta, M. (1997), A Data Set of Critical Heat Flux for Flow-Boiling of Water in Small-Diameter Tubes under Low-Pressure Conditions, Ph.D. Thesis, Kyoto University, Kyoto, Japan, Appendix A, 44 pages.
Lee, D.H. (1965), An Experimental Investigation of Forced Convection Burnout in High-Pressure Water. Part III: Long Tubes with Uniform and Nonuniform Heat Flux, AEEW-R 355, United Kingdom Atomic Energy Authority, Harwell, United Kingdom.
Lee, D.H. (1966), An Experimental Investigation of Forced Convection Burnout in High Pressure Water. Part IV: Large Diameter Tubes at about 1,600 P.S.I., AEEW-R 479, Atomic Energy Research Establishment, Winfrith, Dorchester, Dorset, United Kingdom, 70 pages.
Leung, L.K.H., et al. (1989). This data set was obtained by Leung as part of his Ph.D. Thesis research. He did not report the data set in his thesis; however, the thesis describes the experimental setup (Leung, L.K.H. (1994), A Model for Predicting the Pressure Gradient along a Heated Channel during Flow Boiling, Ph.D. Thesis, Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada).
Leung, L.K.H., S.T. Yin, and J. Martin (1990), Measurements of Critical Heat Flux, Post-Dryout Pressure Drops and Wall Temperature in Tubes, COG-90-32 (also ARD-TD-227) AECL proprietary report.
Lowdermilk, W.H., C.D. Lanzo, and B.L. Siegel (1958), Investigation of Boiling Burnout and Flow Stability for Water Flowing in Tubes, NACA-TN-4382, National Advisory Committee for Aeronautics (NACA), Cleveland, OH, September 1958, 52 pages.
Matzner, B., E.O. Moeck, J.E. Casterline, and G.A. Wikhammer (1965), Critical Heat Flux in Long Tubes at 1,000 psi with and without Swirl Promoters, ASME Proceedings, Paper No.
65-WA/HT-30, AECL-2446, 16 pages.
Mayinger F., O. Schad, and E. Weiss (1966), Untersuchung der kritischen Heizflachenbelastung (Burnout) bei siedendem Wasser, Investigation into the Critical Heat Flux in Boiling, Report No. 09.03.01, Maschinenfabrik Augsburg-Nurnberg AG, Munich, Germany, May 1966, 265 pages.
Nariai H., F. Inasaka, and T. Shimura (1987), Critical Heat Flux of Subcooled Flow Boiling in Narrow Tube, in the Proceedings of the 1987 ASME/Japan Society of Mechanical Engineers (JSME) Thermal Engineering Joint Conference, Honolulu, HI, March 22-27, 1987, Volume 5, March 1987, pp. 455-462.
Nguyen, D.M., and S.T. Yin (1975), An Experimental Investigation of Water Critical Heat Flux in a Tubular Channel in Both Horizontal and Vertical Attitudes, Technical Memorandum CWTM-013-HT, Westinghouse Canada Limited, Toronto, Canada, December 1975, 39 pages.
Olekhnovitch, A. (1997), Etude de Flux de Chaleur Critique a des Pressions Faibles, Ph.D.
Thesis, Universite de Montreal, Montreal, Quebec, Canada, October 1997, 599 pages.
83 Pabisz, R.A., Jr., and A.E. Bergles (1996), Enhancement of Critical Heat Flux in Subcooled Flow Boiling of Water by Use of a Volatile Additive, in the Proceedings of the ASME Heat Transfer Division (HTD): Presented at the 1996 International Mechanical Engineering Congress and Exposition, Atlanta, GA, November 17-22, 1996, HTD-Volume 334, Volume 3, pp. 305-312.
Peterlongo, G., R. Ravetta, B. Riva, L. Rubiera, and T.A. Tacconi (1964), Large Scale Experiments on Heat Transfer and Hydrodynamics with SteamWater Mixtures: Further Critical Power and Pressure Drop Measurements in Round Vertical Tubes with and without Internal Obstacles, R-122, CISE, Segrate, Milan, Italy.
Rudzinski, K.F., reference unknown.
Shan, J.Q. (2005), reference unknown. While working at the University of Ottawa, J.Q. Shan identified some critical heat flux (CHF) tube data that were labeled as Col-U (Columbia University).
Smolin, V.N., V.K. Polyakov, and V.I. Esikov (1962), On the Heat Transfer Crisis in Steam-Generating Pipes, Soviet Journal of Atomic Energy 13:968-972, Translation from Atomnaya Energiya 13(4):360-364.
Smolin, V.N., et al. (1979), reference unknown. The Smolin (1979) data set was contained in a database that Kirillov transferred to the University of Ottawa around 1992; the section titled, Kirillov Database (1992), in Appendix I of this report describes the database.
Snoek, C.W. (1988), Comparison of the Critical Heat Flux in Interconnected Subchannels of Different Geometry, CRNL-4231, CANDEV-88-23, AECL, Chalk River, Ontario, Canada, 90 pages.
Soderquist, B. (1994), Swedish Tube CHF Data, personal communication with D.C.
Groeneveld, the Department of Nuclear Reactor Engineering, Royal Institute of Technology, Stockholm, Sweden, March 1994, 19 pages.
Swenson, H.S., J.R. Carver, and C.R. Kakarala (1962), The Influence of Axial Heat-Flux Distribution on the Departure from Nuclear Boiling in a Water-Cooled Tube, ASME Proceedings, Paper No. 62-WA-297, 15 pages.
Tain, R.-M. (1994), An Investigation of CHF Fluid-to-Fluid Scaling and Multi-Fluid Prediction Techniques, Ph.D. Thesis, University of Ottawa, Ottawa, Ontario, Canada, December 1994, 406 pages.
Tong, L.S. (1964), reference unknown.
Waters, E.D., J.K. Anderson, W.L. Thorne, and J.M. Batch (1965), Experimental Observations of Upstream Boiling Burnout, Chemical Engineering Progress Symposium Series 61(57):
230-237.
Williams, C.L., and S.G. Baus (1980), Critical Heat Flux Experiments in a Circular Tube with Heavy Water and Light Water, WAPD-TM-1462, Bettis Atomic Power Laboratory, West Mifflin, PA, May 1980, 69 pages.
84 Yin, S.T., T.-J. Liu, Y.-D. Huang, and R.M. Tain (1988), Measurements of Critical Heat Flux in Forced Flow at Pressures Up to the Vicinity of the Critical Point of Water, in the Proceedings of the 1988 National Heat Transfer Conference, Houston, TX, July 24-27, 1988, Volume 2, pp. 501-506.
Zenkevich, A., et al. (1969), reference unknown. The only indirect reference to the Zenkevich data set is from Kirillovs 1992 CHF database transferred to the University of Ottawa in the early 1990s (see a description of the database in the section Kirillov Database (1992), in Appendix I of this report).
Zenkevich, A., et al. (1971), reference unknown. The only indirect reference to the Zenkevich data set is from Kirillovs 1992 CHF database transferred to the University of Ottawa in the early 1990s (see a description of the database in the section Kirillov Database (1992), in Appendix I of this report).
Zenkevich, B.A., O.L. Peskov, and N.D. Subbotin (1964), A Study of Critical Heat Flux Densities for Tubular Fuel Elements at Atomic Power Stations, Teploenergetika (in Russian) 11(6):20-22; Thermal Engineering (English translation) 11(6)23-25.
Zenkevich, A., O.L. Peskov, G.A. Petrishcheva, N.D. Sergeev, and V.I. Subbotin (1974),
Analysis and Generalization of Experimental Data on Heat Transfer Crisis Associated with Forced Convection of Cooling Water in Tubes, Institute of Physics and Power Engineering, Obninsk, Russia (1969); AECL-Tr-Misc.-304, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada, English translation by G. Phillips (1974), 440 pages.
B-2 References to Supplementary Critical Heat Flux Data Sets That Were Processed But Not Used To Derive the 2006 Critical Heat Flux Lookup Table Becker, K.M. (1966), Some Remarks on Correlating the Harwell Round Tube Burnout Data, AE-RTL-855, Atomenergi, Studsvik, Sweden, May 1966, 16 pages.
Becker, K.M., and C.H. Ling (1970), Burnout Measurements in a Round Tube of 7,100 mm Heated Length, KTH-NEL-13, Royal Institute of Technology, Stockholm, Sweden, Laboratory of Nuclear Engineering, June 1970, 17 pages.
Belyakov, I.I. (1976), Issledovanie uhudsheniya Teploobmena v Vertikalnih Trubah (in Russian), Investigation of Post Dryout in Vertical Tubes, Report No. 053501/0-9119, Centralnii Nauchno-Issledovatelskii i Proektno-Konstruktorskii Kotlotyrbinnyii Institut, Central Boiler-Turbine Institute, Leningrad, Russia, 126 pages.
Bergles, A.E., J.P. Roos, and J.G. Bourne (1968), Final Summary Report, Investigation of Boiling Flow Regimes and Critical Heat Flux, NYO-3304-13, Dynatech Corporation, Contract to U.S. Atomic Energy Commission, Washington, DC, July 1968, 77 pages.
Bertoletti, S., C. Lombardi, and M. Silvestri (1964), Heat Transfer to Steam-Water Mixtures, CISE, Milan, Italy, Report CISE R-78, January 1964, 90 pages.
Biancone, F., A. Campanile, G. Galimi, and M. Goffi (1965), Forced Convection Burnout and Hydrodynamic Instability Experiments for Water at High Pressure. Part I: Presentation of Data
85 for Round Tubes with Uniform and Nonuniform Power Distribution, EUR-2490.e, European Atomic Energy Community.
Campolunhi, F., M. Cumo, G. Ferrari, and R. Loe (1973), An Experimental Study on Heat Transfer in Long Sub-Critical Once-Through Steam Generators, International Meeting on Reactor Heat Transfer, Karlsruhe, F.R., Germany, October 9, 1973, M.D. Donne (Ed.),
Gesellschaft for Kernforschung mbH, Karlsruhe, Germany, Paper No. 8/9, pp. 373-401.
Ceresa, I., A. Era, G. Greco, and F. Lucchini (1974), Dryout with Steam-Water Mixtures at 500 bars in Uniformly Heated Round Ducts, CISE-R-359, CISE, Segrate, Milan, Italy, November 1974.
Clark, J.A., and W.M. Rohsenow (1952), Local Boiling Heat Transfer to Water at Low Reynolds Number and High Pressures, DIC-6627, Massachusetts Institute of Technology, Cambridge, MA, July 1952.
Cumo, M., G. Palazzi, and G.C. Urbani (1979), On the Limiting Critical Quality and the Deposition Controlled Burn-Out, Comitato Nazionale Energia Nucleare, Rome, Italy, 1979 Meeting of the European Two-Phase Flow Group, Ispra, Italy, June 5-7, 1979, Paper No. C3, 20 pages.
DeBortoli, R.A., and R. Nasnovi (1957), Burnout Data for 0.186 Inch Inside Diameter by 12 Inches Long Round Nickel Tube, WAPD-TH-308, Westinghouse Atomic Power Division, Westinghouse Electric Corporation, Pittsburgh, PA, 14 pages.
Eicheldinger, C. (1962), PM Research and Development Program, 5th Quarterly Progress Report, MND-MD-2560-2, Martin Marietta Nuclear Division, Martin Marietta Corporation, Raleigh, NC, June 1962, 176 pages.
Epstein, H.M., J.W. Chastain, and S.L. Fawcett (1956), Heat Transfer and Burnout to Water at High Subcritical Pressures, BMI-1116, Battelle Memorial Institute, Columbus, OH, July 1956, 26 pages.
Fiori, M.P., and A.E. Bergles (1968), Model of Critical Heat Flux in Subcooled Flow Boiling, Report No. 70281-56, Massachusetts Institute of Technology, Cambridge, MA, September 1968, 158 pages.
Hassid, A., A. Milani, R. Ravetta, and L. Rubiera (1967), Heat Transfer Crisis with Steam-Water Mixtures in Round Conduits: Reproducibility Tests with Different Experimental Facilities, CISE-R-236, CISE, Milan, Italy, November 1967, 77 pages.
Hunt, T.W., H.S. Jacket, J.D. Roarty, and J.E. Zerbe (1955), An Investigation of Subcooled and Quality Burnout in Circular Channels, WAPD-LSR(IM)-1, Westinghouse Electric Corporation, Atomic Power Division, Pittsburgh, PA, January 1955, 45 pages.
Inasaka et al. (1991), reference unknown. These data may have been included in the database transferred by Celata to the University of Ottawa (personal communication letter between Celata and Professor S.C. Cheng, University of Ottawa, Ottawa, Ontario, Canada, April 22, 1993).
86 Isakoff, L., and H.F. Measley (1962), Heavy Water Moderated Power Reactors, DP-795, E.I.
du Pont de Nemours and Company, Wilmington, DE, November 1962, 39 pages.
Kinoshita, H., H. Nariai, and T. Yoshida (1998), Critical Heat Flux in Subcooled Flow Boiling with Water in a Tube with Axially Nonuniform Heating, Heat TransferJapanese Research 27(2):169-178.
Lee, D.H., and J.D. Obertelli (1963), An Experimental Investigation of Forced Convection Burnout in High Pressure Water. Part I: Round Tubes with Uniform Flux Distribution, AEEW-R 213, Atomic Energy Research Establishment, Winfrith, Dorchester, Dorset, United Kingdom, 81 pages.
Lee, D.H. (1965), An Experimental Investigation of Forced Convection Burnout in High Pressure Water. Part III: Long Tubes with Uniform and Non-Uniform Axial Heating, AEEW-R 355, Atomic Energy Research Establishment, Winfrith, Dorchester, Dorset, United Kingdom, March 1965, 66 pages.
Little, R.B., and R. Trenberth (1966), AEEW-M 623, A Pilot Experimental Investigation into Burnout with Subcooled Water Flowing inside a Tube at High Velocity, Atomic Energy Research Establishment, Winfrith, Dorchester, Dorset, United Kingdom, March 1966, 13 pages.
McGill, H.L., and W.L. Sibbitt (1951), Heat Transfer and Pressure Drop of Water Flowing in a Small Tube, ANL-4603, Argonne National Laboratory, Lemont, IL, Part 1, February 1951, 58 pages.
Mudawar, I., and M.B. Bowers (1999), Ultra-High Critical Heat Flux (CHF) for Subcooled Water Flow BoilingI: CHF Data and Parametric Effects for Small Diameter Tubes, International Journal of Heat and Mass Transfer 42:1405-1428.
Nariai, H., F. Inasaka, W. Fijisaki, and H. Ishiguro (1991), Critical Heat Flux of Subcooled Flow Boiling in Tubes with Internal Twisted Tape, in the 7th Proceedings of Nuclear Thermal Hydraulics: American Nuclear Society 1991 Winter Meeting, American Nuclear Society, La Grange Park, IL, November 1991, pp. 38-46.
Nilsson, L. (1970), Repeatability Tests of Critical Heat Flux Data for 1970 Meeting of the European Two-Phase Flow Group, Comparison of Results by Becker's Burnout Correlation, AE-TPM-RL-1229, Aktiebolaget Atomenergi, Stockholm, Sweden, June 1970, 24 pages.
Ornatskii, A.P., and A.M. Kichigin (1961), Issledovanie Zavisimosti Kriticheskoi Teplovoi Nagruzki ot Vesovoi Skorosti, Nedogreva i Davleniya (in Russian), Teploenergetika 8(2):75-79.
Ornatskii A.P., and A.M. Kichigin (1962), Kriticheskii Teplovie Nagrzki pri Kipenii Nedogrretoi Vodi v Trubah Malogo Diametra v Oblasti Visokih Davlenii (in Russian), Teploenergetika 9(6)44-47.
Ornatskii A.P., and Vinyarskii (1965), Heat Transfer Crisis in a Forced Flow of Underheated Water in Small-Bore Tubes, Teplofizika Visokikh Temperatur (in Russian) 3:444-451; High Temperature (English translation) 3:400-406.
87 Ornatskii, A.P. (1963), Kriticheskie Teplovie Nagruzki i Teplootdacha pri Vinyzdennom Dvizenii Vodi v Trubah v oblasti Sverhvsokih Davlenii (175-220 atm) (in Russian), Critical Heat Loads and Heat Transfer for a Forced Flow of Water in Tubes in the Region of Super High Pressures (175-220 atm), Teploenergetika 10(3):66-69.
Peskov, O.L., V.I. Subbotin, B.A. Zenkevich, N.D. Sergeev (1961), The critical heat Fux for the Flow of steam-water mixtures through pipes, in: S.S. Kutateladze (Ed.), Voprosy Teplootdachi i Gidravliki Dvukhfaznykh Sred, Gosénergoizdat, Moscow, Russia, 1961. Problems of Heat Transfer and Hydraulics of Two-Phase Media, Pergamon Press, Oxford, UK, 1969, pp. 48-62.
Reynolds, J.M. (1957), Burnout in Forced Convection Nucleate Boiling of Water, DSR 7-7673, Massachusetts Institute of Technology, Cambridge, MA, July 1957.
Ruan, S. (1994), Experimentelle Untersuchung der kritischen Warmestromdichte von aufwarts und abwarts stromendem Wasser in einem senkrechten Kreisrohr bei niedrigen Druken und niedrigen Massenstromdichten, Fortschritt Berichte VDI, Reihe 3: Verfahrenstechnik, No. 351, 147 pages.
Shlykov, Yu.P., A.D., Leongardt, and A.P. Potapov (1970), Burnout When Boiling with Subcooled Water Flowing in Tubes at High Velocities and Low Pressures, Thermal Engineering (English translation) 17(3):91-93, from Teploenergetika (in Russian) 17(3):63-65.
Stein, M. (2004), Systematische Untersuchung der kritischen Warmestromdichte beim Stromungssieden von Wasser in lotrechten Kreisrohren mit und ohne poroseer Beschichtung, Ph.D. Thesis, Techischen Universitat Berlin, Berlin, Germany, April 2004, 245 pages.
Tramontini, V.N., M.L. Greenfield, G.C. Wong, R.P. Lipkis, H.I. Leon, R.K. Breeze, and G.S.
Arbuthnot (1951), Final Report on Studies in Boiling Heat Transfer, COO-24, University of California, Los Angeles, CA, March 1951, 498 pages.
Vandervort, C.L. (1992), The Ultimate Limits of Forced Convective Subcooled Boiling Heat Transfer, Ph.D. Theses, Faculty of Rensselaer Polytechnic Institute, Troy, NY, May 1992, 321 pages.
Weatherhead, R.J. (1963), Nucleate Boiling Characteristics and the Critical Heat Flux Occurrence in Subcooled Axial-Flow Water Systems, ANL-6675, Argonne National Laboratory, Lemont, IL, March 1963.
Weatherhead, R.J. (1963), Heat Transfer, Flow Instability, and the Critical Heat Flux for Water in a Small Tube at 200 psia, ANL-6715, Argonne National Laboratory, Lemont, IL, June 1963.
Weber, P., and K. Johannsen (1990), Study of Critical Heat Flux Condition at Convective Boiling of Water: Temperature and Power Controlled Experiments, in the Proceedings of the 9th International Heat Transfer Conference, Jerusalem, Israel, G. Hetsroni (ed.), Hemisphere Publication Corporation, New York, NY, Volume 2, pp. 63-68.
Yildiz, S. (1997), Experimentelle Untersuchung der kritischen Warmestromdichte im Ubergang von DNB-zum Dryout-Mechanismus in glatten and poros beschichteten Rohren bei niedrigen Drucken und Massenstromdichten, Ph.D. Thesis, Technischen Universitat Berlin, Berlin, Germany, 166 pages.
88 Zou, L. (2003), Experimental Study of Dryout of Upward Flow in Vertical Circular Tube (in Chinese), Ph.D. Thesis, China Nuclear Engineering Research Institute, August 2003, 57 pages.
B-3 References to Additional Data Sets Not Yet Processed Aladev, I.T., L.D. Dodonov, and V.S. Udalov (1959), Burn-Out Heat Flux for Flow of Water in Pipes, Soviet Journal of Atomic Energy 6(1):42-45, January 1959.
Becker, K.M., and G. Hernborg (1964), Measurements of Burnout Conditions for Flow of Boiling Water at Low Pressures, AE-R4-346 RPL-753, Aktiebolaget Atomenergi, Stockholm, Sweden, September 1964, 21 pages.
Becker, K.M. (1965), An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, AE-178, Aktiebolaget Atomenergi, Stockholm, Sweden, 163 pages.
Becker, K.M., G. Hernborg, M. Bode, and O. Eriksson (1965), Burnout Data for Flow of Boiling Water in Vertical Round Ducts, Annuli and Rod Clusters, AE-177, Aktiebolaget Atomenerg, Stockholm, Sweden, 116 pages.
Becker, K.M., C.H. Ling, S. Hedberg, and G. Strand (1983), An Experimental Investigation of Post Dryout Heat Transfer, KTH-NEL-33, Royal Institute of Technology, Department of Nuclear Reactor Engineering, Stockholm, Sweden, May 1983, 631 pages.
Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1965), Experiments on Burnout in Uniformly Heated Round Tubes at 1,000 psia with Steam-Water Mixtures at the Tube Inlet, AERE-R 5072, Atomic Energy Research Establishment, Harwell, Berkshire, United Kingdom, November 1965, 32 pages.
Bennett, A.W., G.F. Hewitt, H.A. Kearsey, and R.K.F. Keeys (1967), Heat Transfer to Steam-Water Mixtures Flowing in Uniformly Heated Tubes in Which the Critical Heat Flux Has Been Exceeded, AERE-R 5373, Atomic Energy Research Establishment, Harwell, Berkshire, United Kingdom.
Bergles, A.E. (1962), Force-Convection Surface-Boiling Heat Transfer and Burnout in Tubes of Small Diameter, Ph.D. Thesis, Massachusetts Institute of Technology, Cambridge, MA, May 1962, 153 pages.
Bernath, L. (1960), A Theory of Local-Boiling Burnout and Its Application on Existing Data, Chemical Engineering Progress Symposium Series, Heat TransferStorrs 56(30):95-116.
Bertoletti, S., G.P. Gaspari, C. Lombardi, and Z. Zavattarelli (1963), Critical Heat Flux Data for Fully Developed Flow of Steam-Water Mixtures in Round Vertical Tubes with Non-Uniform Axial Power Distribution, Report No. R-74, CISE, Segrate, Milan, Italy, April 1963, 30 pages.
Biancone, F., A. Campanile, G. Galimi, and M. Goffi (1965), Forced Convection Burnout and Hydrodynamic Instability Experiments for Water at High Pressure. Part I: Presentation of Data for Round Tubes with Uniform and Non-Uniform Power Distribution, EUR 2490.e, European Atomic Energy Community (EURATOM), 102 pages.
89 CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 8, AB Atomenergi, Studsvik, Sweden, pp. 101-110, data from Report No. AE-Rl 700504.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 9, Delahousse, A., Center for Nuclear Studies, Grenoble, France, pp.
111-126.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 10, G.P. Gaspari and M. Protti, CISE, Segrate, Milan, Italy, pp. 127-164.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 11, A. Bahr, H. Herkenrath, and P. Mork-Morkenstein, CCR EURATOM, Ispra, Italy, pp. 165-178.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 12, K.M. Becker, Royal Institute of Technology, Stockholm, Sweden, pp. 179-184.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 13, SORIN, Sluggia, Italy, pp. 185-194.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970, Chapter 14, United Kingdom Atomic Energy Authority, Winfrith, United Kingdom, pp. 195-199.
Casterline, J.E., and B. Matzner (1964), Topical Report #1 Task XVI of Contract at(30-3)-187, USAEC/AECL Cooperative Program on Heavy Water Moderated Power Reactors, Columbia University, New York, NY, July 1964, 59 pages.
Celata, G.P., M. Cumo, and A. Mariani (1992), Subcooled Water Flow Boiling CHF with Very High Heat Fluxes, Revue Générale de Thermique 31(362):106-114, February 1992.
De Bortoli, R.A., et al. (1958), Forced Convection Heat Transfer Burnout Studies for Water in Rectangular Channels and Round Tubes at Pressure above 500 psia, WAPD-188, Westinghouse Electric Corp. Bettis Plant, Pittsburgh, PA.
Doroshchuk, V.E., and F.P. Frid (1961), The Critical Heat Flux for Water Flowing through Round Tubes, in Problems of Heat Transfer and Hydraulics of Two-Phase Media, S.S.
Kutateladze (ed.) (in Russian), Chapter 4, pp. 38-47, Translated into English by O.M. Blunn, J.G. Collier (ed.).
90 Doroshchuk, V.E., and F.P. Lantsman (1963), Vliyanie Diametra Kanala na Kriticheskie Teplovie Nagruzki (in Russian), Effect of Channel Diameter on Critical Heat Loads, Teploenergetika 10(8):73-76.
Doroshchuk, V.E., and F.P. Lantsman (1964), Effect of Pressure and Mass Flow Rate on Burnout Heat Fluxes in a Water and Steam-Water Mixture Flow in Tubes, International Journal of Heat and Mass Transfer 7:187-190.
Dougherty, T., C. Maciuca, E.V. McAssey, Jr., D.G. Reddy, and B.W. Yang (1992), Columbia University Flow Instability Experimental Program, Volume 7, Single Tube Tests, Critical Heat Flux Test Program (U), WSRC-TR-93-688, Westinghouse Savannah River Company, Aiken, SC; CU-HTRF-T8, Columbia University, New York, NY, September 1992, 112 pages.
Gambill, W.R., R.D. Bundy, and R.W. Wansbrough (1961), Heat Transfer, Burnout, and Pressure Drop for Water in Swirl Flow through Tubes with Internal Twisted Tapes, Symposium Series, Chemical Engineering Progress 57(32):127-137.
Greisen, D.A., D.C. Rousar, and W.R. Thompson (1999), Critical Heat Flux Limits for High Velocity, High Subcooling Water Flows, Journal of Thermophysics and Heat Transfer 13(3):321-327, September 1999.
Hassid, A., G.C. Manzoni, R. Ravetta, and L. Rubiera (1966), Heat Transfer Crisis with Steam-Water Mixtures: An Experimental Study on the Increase Critical Power with Local Swirl Promoters in Round Tubes, CISE-R-169, CISE, Milan, Italy, May 1966.
Hassid, A., A. Milani, R. Revetta, and L. Rubiera (1968), Heat Transfer Crisis with Steam-Water Mixtures in Round Conditions: Reproducibility Tests with Different Experimental Facilities, EUR 3920.e, European Atomic Energy Community (EURATOM).
Hata, K., et al. (2005), reference unknown.
Hood, R.R., L. Isakoff, and D.F. Babcock (coordinator) (1963), Heavy Water Moderated Power Reactors, Progress Report May-June 1963, DP-855, E.I. du Pont de Nemours and Company, Wilmington, DE, August 1963, 46 pages.
Hood, R.R., D.F. Babcock (coordinator) (1964), Heavy Water Moderated Power Reactors, Progress Report January-February 1964, DP-895, E.I. du Pont de Nemours and Company, Wilmington, DE, March 1964, 34 pages.
Inasaka, F., and H. Nariai (1992), Critical Heat Flux of Subcooled Flow Boiling for Water in Uniformly Heated Straight Tubes, Fusion Engineering and Design 19:329-337.
Inasaka, F. (1993), Critical Heat Flux of Subcooled Flow Boiling in Water under Uniform Heating Conditions, Papers of Ship Research Institute 30(4):1-69.
Jens, W.H., and P.A. Lottes (1952), Two-Phase Pressure Drop and Burnout Using Water Flowing in Round and Rectangular Channels, ANL-4915, Argonne National Laboratory, Lemont, IL, October 1952, 44 pages.
91 Kabata, Y., R. Nakajima, and K. Shioda (1996), Enhancement of Critical Heat Flux for Subcooled Flow Boiling of Water in Tubes with a Twisted Tape and with a Helically Coiled Wire, Conference Series, International Conference on Nuclear Engineering, Volume 1, Part B, pp. 639-646.
Konkov, A.S. (1966), Experimental Study of the Conditions under Which Heat Exchange Deteriorates When a Steam-Water Mixture Flows in Heated Tubes, Thermal Engineering 13(12):77-82, Translation from Teploenergetika 13(12):53-57.
Kutateladze, S.S. (1959), Kriticheskie Teplovie Potoki pri Techenii Smachivaoi shei Zidkosti s Yadrom, Nedogretim do Temperaturi Nasisheniya (in Russian), Critical Heat Flux in the Flow of a Wetting Liquid with the Core Heated to Saturation Temperature, Nauchnie Dokladi Visshei Shkoli, Energetika, No. 2, pp. 229-239.
Lee, Y.H., and S.H. Chang (2003), The Effect of Vibration on Critical Heat Flux in a Vertical Round Tube, Journal of Nuclear Science and Technology 40(10):734-743, October 2003.
Leung, A. (1982), A Study of the CHF Performance of Light and Heavy Water in Long Vertical Tubes, AI-1024, Atomic Energy of Canada Limited, Thermalhydraulics Branch, Chalk River, Ontario, Canada, April 1982, 69 pages.
Lowdermilk, W.H., and W.F. Weiland (1954), Some Measurements of Boiling Burn-Out, NACA-RM-E54K10, NACA, Cleveland, OH, November 1954, 18 pages.
Mayersak, J., S.D. Raezer, and E.A. Bunt (1964), Confirmation of Gambill-Green Straight Flow Burnout Heat Flux Equation at High Flow Velocity, Transactions of the ASME (Series C),
Journal of Heat Transfer 86:297-198.
Mishima, K. (1984), Boiling Burnout at Low Flow Rate and Low Pressure Conditions, Research Reactor Institute, Kyoto University, Kyoto, Japan, 336 pages.
Nariai, H., F. Inasaka, W. Fijisaki, and H. Ishiguro (1991), Critical Heat Flux of Subcooled Flow Boiling in Tubes with Internal Twisted Tape, in the 7th Proceedings of Nuclear Thermal Hydraulics: American Nuclear Society 1991 Winter Meeting, American Nuclear Society, La Grange Park, IL, November 1991, pp. 38-46.
Nariai, H., F. Inasaka, and T. Shimura (1987), Critical Heat Flux of Subcooled Flow Boiling in Narrow Tube, in the Proceedings of the 1987 ASME/JSME Thermal Engineering Joint Conference, Honolulu, HI, March 22-27, 1987, Volume 5, pp. 455-462.
Pabisz, R.A., and A.E. Bergles, (1996), Enhancement of Critical Heat Flux in Subcooled Flow Boiling of Water by Use of a Volatile Additive, in the Proceedings of the ASME Heat Transfer Division (HTD): Presented at the 1996 International Mechanical Engineering Congress and Exposition, Atlanta, GA, November 17-22, 1996, HTD-Volume 334, Volume 3, pp. 305-312.
Pasint, D., and R.H. Pai (1966), Empirical Correlation of Factors Influencing Departure from Nucleate Boiling in Steam-Water Mixtures Flowing in Vertical Round Tubes, Transactions of the ASME Journal of Heat Transfer, 88(4):367-373, November 1966.
92 Povarnin, P.I., and S.T. Semenov (1959), Issledovanie Krizisa Kipeniya Vodi, Nedogretoi do Temperaturi Nasisheniya pri Dvizenii ee s Bolshoi Skorostiyo v Trubah (in Russian),
Teploenergetika 6(4):72-79.
Povarnin, P.I., and S.T. Semenov (1960), Issledovanie Krizisa Kipeniya pri Techenii Nedogretoi Vodi v Trubkah Malih Dimetrov pri Visokih Davleniyah (in Russian), Teploenergetika 7(1):
79-85.
Rickard, C.L. (1954), Boiling Burnout Newsletter No. 1, BNL-2097, Brookhaven National Laboratory, Upton, NY, December 1954, 8 pages.
Rousar, D.C., and N.E. VanHuff (1966), Heat Transfer Characteristics of 98% H2O2 at High Pressure and High Velocity, Contract AF04 (611)-10785, Final Report AFRPL-TR-66-263, Aerojet, Sacramento, CA, August 1966, 246 pages.
Rudzinski, K.F., D.C. Groeneveld, and S. Doerffer (1999), Analysis of the Flow Transient CHF and Rewetting Data Obtained in an 8 mm Tube, FFC-FCT-65 COG-96-510, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada, February 1999, 142 pages.
Smolin, V.N., V.I. Esikov, and S.V. Shpanskii (1970), Departure from Nucleate Boiling in Channels with Heat Flux Peaking, UDC 621.1.016.4, Thermal Engineering 17(5):95-98, Original in Russian in Teploenergetika 17(5):66-69.
Smolin, V.N., S.V. Shpanskii, V.I., Esikov, and T.K. Sedova (1977), Method of Calculating Burnout in Tubular Fuel Rods When Cooled by Water and Water-Steam Mixture, Teploenergetika 24(12):30-35.
Stein, M. (2004), Systematische Untersuchung der kritischen Warmestromdichte beim Stromungssieden von Wasser in lotrechten Kreisrohren mit und ohne poroseer Beschichtung, Ph.D. Thesis, Techischen Universitat Berlin, Berlin, Germany, April 2004, 229 pages.
Sudo, Y. (1996), Critical Heat Flux under Conditions of High Subcooling and High Velocity at Atmospheric Pressure, Transactions of the JSME (Series B), Volume 62, No. 601, Paper No.
96-0100, pp. 3376-3382, September 1996.
Sursock, J.P. (1973), Un Modele DAssechement en Ecoulement Double-Phase, Note CEA-N-1665, Commissariat a lEnergie Atomique, Paris, France, October 1973, 44 pages.
Swenson, H.S., J.R. Carver, and G. Szoeke (1962), The Effects of Nucleate Boiling Versus Film Boiling on Heat Transfer in Power Boiling Tubes, Transactions of the ASME, Journal of Engineering for Power 84(4):365-371, October 1962.
Vijayarangan, B.R., S. Jayanti, and A.R. Balakrishnan (2005), Studies on Critical Heat Flux in Flow Boiling at Near Critical Pressures, International Journal of Heat and Mass Transfer 49:259-268.
Watson, G.B., R.A. Lee, and M. Wiener (1974), Critical Heat Flux in Inclined and Vertical Smooth and Ribbed Tubes, in the Proceedings of the 5th International Heat Transfer Conference, Tokyo, Japan, September 3-4, 1974, Volume 4, Paper B6.8, pp. 275-279.
93 Weber, P. (1990), Experimentelle Untersuchungen zur Ubergangssieden von stromenden Wasser unter erhohten Druck, Fortschritt Berichte VDI, Reihe 3: Verfahrenstechnik, No. 226, 179 pages.
Whittle, R.H., and R. Forgan (1967), A Correlation for the Minima in the Pressure Drop versus Flow-Rate Curves for Sub-Cooled Water Flowing in Narrow Heated Channels, Nuclear Engineering and Design, Volume 6, Issue 1, 1967, Pages 89-99.
Wurtz, J. (1978), An Experimental and Theoretical Investigation of Annular Steam-Water Flow in Tubes and Annuli at 30 to 90 bar, Report No. 372, Riso National Laboratory, Roskilde, Denmark, 146 pages.
Zenkevich, B.A. (1964), O Vlijnii Skorosti Techenija Nedogretoi Vodi na Kriticheskoie Teplovie Potoki (in Russian), On the Effect of Subcooled Water Flow Velocity on Burnout Heat Fluxes, Inzenerno-Fizicheskii Zurnal 7(7):43-46.
Zenkevich, B.A., and V.I. Subbotin (1957), Critical Heat Loadings in Forced Flow of Water Heated Below Boiling, Letters to the Editor, The Soviet Journal of Atomic Energy, 1958, Volume 3, Number 2, pp. 915-919.
B-4 References to Critical Heat Flux Data Compilations Bernath, L. (1960), A Theory of Local-Boiling Burnout and Its Application on Existing Data, Chemical Engineering Progress Symposium Series, Heat TransferStorrs 56(30):95-116.
Biasi, L., G.C. Clerici, S. Garribba, R. Sale, and A. Tozzi (1967), Studies on Burnout Part 3A New Correlation for Round Ducts and Uniform Heating and Its Comparison with World Data, Energia Nucleare14(9):530-537, September 1967.
Celata, G.P., and A. Mariani (1992), A Data Set of Critical Heat Flux in Water Subcooled Flow Boiling, Addendum to Specialists Workshop on the Thermal-Hydraulics of High Heat Flux Components in Fusion Reactors, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Casaccia, Rome, Italy, September 9-12, 1992, and a personal communication to Professor S.C. Cheng, University of Ottawa, Ottawa, Ontario, Canada, April 22, 1993.
Chen, Y., K. Bi, M. Zhao, C. Yang, and K. Du (2015), Critical Heat Flux with Subcooled Flowing Water in Tubes for Pressures from Atmosphere to Near Critical Point, in the Proceedings of the 16th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-16),
Chicago, IL.
CISE (1970), Exercise on Reproducibility of Critical Heat Flux Data, Presentation of Experimental Results, Meeting of the European Two-Phase Flow Group, Segrate, Milan, Italy, June 8-11, 1970.
Cizek, J. (1993), CHF Data Bankthe 3rd Generation, SVUSS-93-05001, Prague, Czech Republic.
94 Firstenberg, H., S. Preiser, K. Goldmann, G. Rabinowitz, and L. LoBianco (1960), Compilation of Experimental Forced-Convection, Quality Burnout Data with Calculated Reynolds Numbers, NDA-2131-16, U.S. Atomic Energy Commission, Washington, DC, June 1960, 60 pages.
Hall, D.D., and I. Mudawar (2000), Critical Heat Flux (CHF) for Water Flow in TubesI.
Compilation and Assessment of World CHF Data, International Journal of Heat and Mass Transfer 43(14):257-2604, July 2000.
Herkenrath, H., and P. Mrk-Mrkenstein (1969), Die Warmeubergangskrise von Wasser bei erzwungener Stromung under hohen Drucken (in German), Atomkernenergie 14(3):163-170.
Inasaka, F. (1993), Critical Heat Flux of Subcooled Flow Boiling in Water under Uniform Heating Conditions, Papers of Ship Research Institute 30(4):1-69.
Kirillov, P.L. (1992). This database was transferred by Kirillov to the University of Ottawa around 1992 and is described in Appendix I in the section titled, Kirillov Database (1992).
Kirillov, P.L., O.L. Peskov, and N.P. Serdun (1985), Control Experiment on Critical Heat Transfer during Water Flow in Pipes, Soviet Atomic Energy 57(6):858-860, Translation from original article by Kirillov et al. (1984) in Atomnaya Energiya 57(6):422-423, December 1984 Liu, W., H. Nariai, and F. Inasaka (2000), Prediction of Critical Heat Flux for Subcooled Flow Boiling, International Journal of Heat and Mass Transfer 43:3371-3390.
Pei, B.-S. (1981), Prediction of Critical Heat Flux in Flow Boiling at Low Qualities, Ph.D.
Thesis, University of Cincinnati, Cincinnati, OH.
Saint-Hilaire, S.V. (2011), Developpement dune Correlation Predisant lApparition du FCC dans un Tube Vertical Chauffe Uniformement en Convection Forcee Avec un Écoulement Ascendant dEau, Master of Applied Science Thesis, Ecole Polytechnique de Montreal, Montreal, Quebec, Canada, August 2011, 94 pages.
Shim, W.J., and J. Park (2003), Analysis of a Generalized CHF Model in Vertical Round Tubes with Uniform Heat Flux, Journal of Industrial and Engineering Chemistry 9:607-613.
Thompson, B., and R.V. MacBeth (1964), Boiling Water Heat Transfer Burnout in Uniformly Heated Round Tubes: A Compilation of World Data with Accurate Correlations, AEEW-R 356, Atomic Energy Research Establishment, Winfrith, Dorchester, United Kingdom, 137 pages.
Tong, L.S., et al. (1964), reference unknown. No documentation could be found for this data set.
Vandervort, C.L. (1992), The Ultimate Limits of Forced Convective Subcooled Boiling Heat Transfer, Ph.D. Thesis, Faculty of Rensselaer Polytechnic Institute, Troy, NY, May 1992, 321 pages.
95 APPENDIX C COMPLETE 2006 CRITICAL HEAT FLUX LOOKUP TABLE The following pages contain the complete 2006 critical heat flux (CHF) lookup table, which gives the CHF in kilowatts per square meter. Section 6.2 describes the table shading that characterizes the CHF uncertainty.
96
97
98
99
100
101
102
103
104
105
106
107
108
109
NUREG/KM-0011 D.C. Groeneveld D.C. Groeneveld Thermalhydraulics Consultants Inc.
PO Box 1335 Deep River, Ontario, Canada K0J 1P0 Division of Systems Analysis Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 This report contains a compilation of over 25,000 CHF data obtained in water-cooled tubes that were used to derive the 2006 Groeneveld CHF lookup table. This compilation is based on 62 data sets that have been obtained during the past 60 years. The pertinent experimental details and possible concerns for these data sets are described. The applicability and validity of the CHF look-up table to reactor conditions of interest is also discussed. A graphical comparison of the ranges of conditions covered by these primary data and subsequently obtained supplementary data sets is also included.
CHF, Critical Heat Flux, Dryout, Groeneveld January 2019 Technical Critical Heat Flux Data Used to Generate the 2006 Groeneveld Lookup Tables NRC-HQ-60-15-C-0002