ML19011A194

From kanterella
Jump to navigation Jump to search
Meeting Summary: Meeting with X-Energy to Provide Pre-Application Information Related to Criticality Safety Regarding the Triso-X Fuel Fabrication Facility License Application
ML19011A194
Person / Time
Site: Triso-X
Issue date: 01/17/2019
From: David Tiktinsky
NRC/NMSS/DFCSE/LOB
To: Margie Kotzalas
NRC/NMSS/DFCSE/LOB
DTiktinsky NMSS/FCSE/LOB 415.8740
Shared Package
ML19011A192 List:
References
Download: ML19011A194 (4)


Text

R. Johnson UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 17, 2019 MEMORANDUM TO:

Margie A. Kotzalas, Chief Fuel Facility Licensing and Oversight Branch Division of Fuel Cycle Safety, Safeguards, and Environmental Review Office of Nuclear Material Safety and Safeguards FROM:

David H. Tiktinsky, Sr. Project Manager /RA/

Fuel Facility Licensing and Oversight Branch Division of Fuel Cycle Safety, Safeguards, and Environmental Review Office of Nuclear Material Safety and Safeguards

SUBJECT:

MEETING

SUMMARY

MEETING WITH X-ENERGY TO PROVIDE PRE-APPLICATION INFORMATION RELATED TO CRITICALITY SAFETY REGARDING THE TRISO-X FUEL FABRICATION FACILITY LICENSE APPLICATION PURPOSE:

The purpose of the meeting was for X-Energy to provide a pre-application discussion of criticality safety related to an application for a first of a kind commercial TRISO-X fuel fabrication facility. X-Energy is planning to apply for a license for a Category II fuel fabrication facility as defined in Title 10 of the Code of Federal Regulations Part 70, Domestic Licensing of Special Nuclear Material.

MEETING

SUMMARY

The meeting took place on December 12, 2018, at the U.S. Nuclear Regulatory Commission Two White Flint Building in Rockville, Maryland. Attendees included X-Energy, Paschal Solutions (an X-Energy contractor) and staff from the Office of Nuclear Material Safety and Safeguards.

DISCUSSION:

X-Energy discussed their approach to integrating criticality safety into their anticipated application for a TRISO-X fuel fabrication facility. X-Energy is currently developing its preliminary design and nuclear criticality safety evaluations.

CONTACT: David Tiktinsky, NMSS/FCSE 301-415-8740

M. Kotzalas 2

They also discussed the qualifications of the team that is performing the criticality analyses and level of experience the team members possess. The design philosophy they are following is intended to assure that double contingency is met in the process design and that nuclear criticality safety is integrated into the design from the onset of the project.

There was a discussion of the establishment of nuclear criticality safety design requirements through the development of preliminary criticality safety evaluations. The calculational methods and validation of criticality models that are being used were described at the meeting. There was a further discussion of the development of the upper subcritical limit and the area of applicability.

X-Energy also stated that the integrated safety analyses (ISA) is scheduled to start in the fourth quarter of 2019 and criticality will be addressed in the ISA. The ISA will also identify criticality scenarios and items relied on for safety.

ACTION ITEMS No regulatory decisions were made at the meeting.

If you have any questions or comments, please contact me at (301) 415-8740 or via e-mail at David.Tiktinsky@nrc.gov.

Docket No. 070-07027

Enclosures:

Attendees List Meeting Attachment

M. Kotzalas 3

SUBJECT:

MEETING

SUMMARY

MEETING WITH X-ENERGY TO PROVIDE PRE-APPLICATION INFORMATION RELATED TO CRITICALITY SAFETY REGARDING THE TRISO-X FUEL FABRICATION FACILITY LICENSE APPLICATION DATED: January 17, 2019 DISTRIBUTION:

FCSE r/f ADAMS Accession Number: ML19011A192 (Pkg)

ML19011A194 (Ltr) *via email OFC FSCE/LOB FSCE/ERB FSCE/LOB FSCE/LOB NAME DTiktinsky

  • AWalker-Smith MKotzalas DTiktinsky DATE 01/16/2019 01/16/2019 01/16/2019 01/17/2019 OFFICIAL RECORD COPY

Enclosure MEETING

SUMMARY

MEETING WITH X-ENERGY TO PROVIDE PRE-APPLICATION INFORMATION RELATED TO CRITICALITY SAFETY REGARDING THE TRISO-X FUEL FABRICATION FACILITY LICENSE APPLICATION December 12, 2018 Attendees List Pete Pappano X-Energy Mark McClure Centrus Tracy Henson Paschal Solutions Clint Gross Paschal Solutions James Hammelman NRC/NMSS Yawar Faraz NRC/NMSS April Smith NRC/NMSS Jeremy Munson NRC/NMSS Samantha Crane NRC Annie Ramirez NRC/NMSS David Tiktinsky NRC/NMSS