OFFICIAL USE ONLY - PROPRIETARY INFORMATION January 25, 2019 MEMORANDUM TO: Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation FROM: Ekaterina Lenning, Project Manager Licensing Processes Branch /RA/
Division of Licensing Projects Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF DECEMBER 4-5, 2018, CLOSED AUDIT OF THE WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-17794-P, REVISION 0, AND WCAP-17794-NP, REVISION 0, "10X10 SVEA FUEL CRITICAL POWER EXPERIMENTS AND NEW CPR CORRELATION: D5 FOR SVEA-96 OPTIMA3" (EPID: L-2014-TOP-0002)
On December 4-5, 2018, a closed audit was conducted by the U.S. Nuclear Regulatory Commission (NRC) staff at the Westinghouse Electric Company (Westinghouse) Rockville office. The purpose of the audit was to review the information related to the NRC review of WCAP-17794-P, Revision 0, and WCAP-17794-NP, Revision 0, "10x10 SVEA Fuel Critical Power Experiments and New CPR Correlation: D5 for SVEA-96 Optima3" Westinghouse Topical Report (TR) and discuss open items contained within the audit plan. By letter dated December 19, 2018, Westinghouse submitted presentation slides (Agencywide Documents Access and Management System Accession No. ML18354B194).
CONTACT: Ekaterina Lenning 301-415-3151
Enclosure:
Proprietary Audit Summary NOTICE: The enclosure transmitted herewith contains proprietary information.
When separated from the enclosure, this transmittal document is decontrolled.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
ML18177A254 (Package); ML18165A087 (Notice);
ML18361A665 (Memorandum); ML18361A669 (Enclosure Proprietary audit summary)
- Concurred via e-mail NRC-001 OFFICE NRR/DLP/PLPB/PM NRR/DLP/PLPB/LA* NRR/DSS/SNPB/BC NRR/DLP/PLPB/BC NRR/DLP/PLPB/PM NAME ELenning DHarrison RLukes DMorey ELenning DATE 12/27/18 1/17/19 1/23/19 1/25/19 1/25/19