Letter Sequence Acceptance Review |
---|
EPID:L-2018-LLA-0286, Armed Forces Radiobiology Research Institute Reactor Facility Request to Amend the Technical Specifications for License R-84 (Approved, Closed) |
|
MONTHYEARML18276A0772018-09-25025 September 2018 Armed Forces Radiobiology Research Institute Reactor Facility Request to Amend the Technical Specifications for License R-84 Project stage: Request ML18292A6132018-10-26026 October 2018 Armed Forces Radiobiology Research Institute - Supplemental Info Needed for Acceptance of Requested LAR Required Qualifications of Reactor Facility Director and Required SRO Presence in Reactor Room During Maintenance/Calibration for Afrri Project stage: Acceptance Review ML18318A3062018-11-0808 November 2018 Us Dept of Defense, Uniformed Services Univ. of the Health Sciences - Submittal of License Amendment Request (LAR) for Reactor Facility Director (Rfd) Qualification Tech Spec, Operations Minimum Staff Tech Spec, and Audit Function Tech Spec Project stage: Request ML18347B3852018-12-14014 December 2018 Armed Forces Radiobiology Research Institute - Acceptance of Requested Licensing Action Regarding License Amendment for Changing the Required Qualifications of Reactor Facility Director for the Armed Forces Radiobiology Research Institute . Project stage: Acceptance Review ML19101A1932019-02-27027 February 2019 Armed Forces Radiobiology Research Institute (Afrri) - License Amendment Request (LAR) for Reactor Facility Director (Rfd) Qualification Tech Spec, Operations Minimum Staff Tech Spec, and Audit Function Tech Spec, Docket No. 50-170, License Project stage: Request ML19058A3272019-08-14014 August 2019 Armed Forces Radiobiology Research Institute - Issuance of Amendment No. 25 Regarding Changing the Required Qualifications of Reactor Facility Director Per Technical Specification 6.1.3.1.B. and 6.2.5 Audit Frequencies Project stage: Approval ML20024D9942020-01-23023 January 2020 NRR E-mail Capture - Acceptance Review Results for Watts Bar Nuclear Plant, Units 1 and 2, License Amendment Request for TS 3.8.1, AC Sources - Operating Project stage: Acceptance Review 2018-09-25
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000170/20232012023-09-26026 September 2023 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000170/2023201 ML23163A2262023-08-10010 August 2023 Examination Result Letter No. 50-170/OL-23-01, Armed Forces Radiobiology Research Institute ML23214A1552023-07-13013 July 2023 Uniformed Services University of the Health Sciences - Change of Director at the Uniformed Services University of the Health Sciences (Usuhs), Armed Forces Radiobiology Research Institute (Afrri) in Bethesda, Maryland ML23163A2252023-06-13013 June 2023 Examination Report Letter No. 50-170/OL-23-01, Armed Forces Radiobiology Research Institute ML23040A4612023-05-0404 May 2023 Examination Confirmation Letter No. 50-170-OL-23-01, Armed Forces Radiobiology Research Institute ML23080A0162023-03-10010 March 2023 2022 Annual Operating Report for the Armed Forces Radiobiology Research Institute (Afrri) ML22263A2382022-09-12012 September 2022 Uniformed Services Univ. of the Health Sciences - Letter of Reply to the Event Report No. 54349 IR 05000170/20222012022-08-24024 August 2022 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000170/2022201 ML22131A3712022-06-27027 June 2022 Armed Forces Radiobiology Research Institute - Issuance of Amendment No. 26 to Renewed Facility Operating License No. R-84 ML22118A8682022-04-28028 April 2022 Armed Forces Radiobiology Research Institute (Afrri) - Supplement to the License Amendment Request for the Digital Instrumentation and Control Upgrade ML22096A2802022-04-0404 April 2022 Uniformed Services Univ. of the Health Sciences, Armed Forces Radiobiology Research Institute (Afrri), Submittal of Supplement to License Amendment Request for the Digital Instrumentation and Control Upgrade ML22090A1762022-03-31031 March 2022 Submittal of 2021 Annual Operating Report Required by the Technical Specifications for the Armed Forces Radiobiology Research Institute (Afrri) Facility Operating License No. R-84, Docket 50-170 ML22067A2462022-03-29029 March 2022 Armed Forces Radiobiology Research Institute (Afrri) Digital Instrumentation and Control (I&C) Audit Report ML21362A7662022-01-14014 January 2022 Armed Forces Radiobiology Research Institute Routine Inspection Report No. 05000170_2021203 ML22007A2642022-01-0707 January 2022 Us Dept. of Defense, Uniformed Services Univ. of the Health Sciences - the Armed Forces Radiobiology Research Institute (Afrri) Is Submitting a Supplement to the License Amendment Request for the Digital Instrumentation and Control Upgrade ML21327A3812021-12-30030 December 2021 Examination Confirmation Letter No. 50-170/OL-22-01, Armed Forces Radiobiology Research Institute ML21316A0332021-11-0808 November 2021 Afrri - LAR - Digital IC - Functional Requirement Specification ML21302A0972021-10-28028 October 2021 Afrri LAR for the Digital Instrumentation and Control Upgrade Revision 1 ML21270A0672021-10-22022 October 2021 Letter - Armed Forces Radiobiology Research Institute - Exemption from 10 CFR 55.31(a)(5) and 55.45(b) ML21302A1072021-10-15015 October 2021 Enclosure 4 - Affidavit for Proprietary Information ML21285A0252021-10-0707 October 2021 Afrri - RO Licensing Exemption Request Supplemental Information ML21260A1842021-09-17017 September 2021 Us Dept of Defense, Uniformed Services Univ. of the Health - Afrri Exemption Request for Licensing of Reactor Operators ML21253A0012021-09-13013 September 2021 Us Department of Defense Armed Forces Radiology Research Institute - Regulatory Audit Plan for Digital Instrumentation and Control System Upgrade IR 05000170/20212022021-08-24024 August 2021 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000170/2021202 IR 05000170/20212012021-08-24024 August 2021 Armed Forces Radiobiology Research Institute - Nuclear Regulatory Commission Security Inspection Report No. 05000170/2021201 (Public) ML21138A9092021-05-14014 May 2021 Uniformed Services Univ. of the Health Sciences, Interim Reactor Facility Director Change Update ML21316A0372021-04-27027 April 2021 Enclosure 4 - Affidavit for Proprietary Information ML21089A1212021-03-29029 March 2021 Uniformed Services Univ. of the Health Sciences - 2020 Annual Operating Report ML21053A2672021-02-25025 February 2021 Armed Forces Radiobiology Research Institute Acceptance of the Application for a Llicense Amendment Digital Instrumentation and Control Upgrade ML21042B8412021-02-11011 February 2021 Transmittal of Proposed Changes to the Technical Specifications in Support of the License Amendment Request for the Digital Instrumentation and Control Upgrade for the Afrri Triga Reactor ML21041A1652021-02-10010 February 2021 EA-2020-056, Armed Forces Radiobiology Research Institute, Relaxation Letter ML21036A2972021-02-0505 February 2021 Response to NRC 01/08/2021 Letter Re License Amendment Request for Facility Operating License No. R-84 for the Afrri Triga Reactor Docket No. 50-170 IR 05000170/20202012021-01-14014 January 2021 Armed Forces Radiobiology Research Institute - Nuclear Regulatory Commission Routine and Follow-up Inspection Report No. 05000170/2020201 ML20303A2062020-11-19019 November 2020 Cover Letter to Confirmatory Order and NRC Investigation Report 1-2019-003 to Armed Forces Radiobiology Research Institute (EA-20-056) ML20318A3392020-11-10010 November 2020 Afrri LAR for Digital I&C Upgrade ML20322A0372020-11-0909 November 2020 Signed Consent and Hearing Waiver from Armed Forces Radiobiology Research Institute (EA-20-056) ML20108F5342020-03-30030 March 2020 2019 Annual Operating Report Required by the Technical Specifications for the Armed Forces Radiobiology Research Institute Reactor (License R-84, Docket 50-170) ML20023C3412020-03-0303 March 2020 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Notice of Violation IR 05000170/20192032019-12-30030 December 2019 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Reactive Inspection Report 05000170/2019203 ML19357A0622019-12-13013 December 2019 Armed Forces Radiobiology Research Institute (Afrri) - Change in Afrri Licensee (Level I Management), Docket No. 50-170, License R-84 ML19281C3322019-09-0505 September 2019 Appointment of Walter (Dale) Tomlinson as the Reactor Facility Director for the Armed Forces Radiobiology Research Institute (Afrri) Training; Docket 50-170, License R-84 ML19058A3272019-08-14014 August 2019 Armed Forces Radiobiology Research Institute - Issuance of Amendment No. 25 Regarding Changing the Required Qualifications of Reactor Facility Director Per Technical Specification 6.1.3.1.B. and 6.2.5 Audit Frequencies IR 05000170/20192022019-07-17017 July 2019 Armed Forces Radiobiology Research Institute - Nuclear Regulatory Commission Reactive Safety Conscious Work Environment Issue of Concern Follow-Up Interim Inspection Report No. 05000170/2019-202-0004 ML19170A1052019-06-0606 June 2019 Us Dept. of Defense, Armed Forces Radiobiology Research Institute - Reply to Notice of Violation Dated May 10, 2019 ML19087A1272019-03-18018 March 2019 Us Dept. of Defense, Uniformed Services Univ. of the Health Sciences - Submittal of 2018 Annual Operating Report IR 05000170/20192012019-03-14014 March 2019 Armed Forces Radiobiology Research Institute - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000170/2019201 ML19101A1932019-02-27027 February 2019 Armed Forces Radiobiology Research Institute (Afrri) - License Amendment Request (LAR) for Reactor Facility Director (Rfd) Qualification Tech Spec, Operations Minimum Staff Tech Spec, and Audit Function Tech Spec, Docket No. 50-170, License ML18347B3852018-12-14014 December 2018 Armed Forces Radiobiology Research Institute - Acceptance of Requested Licensing Action Regarding License Amendment for Changing the Required Qualifications of Reactor Facility Director for the Armed Forces Radiobiology Research Institute . ML18354A7292018-12-0606 December 2018 Us Dept. of Defense, Uniformed Services Univ. of the Health Sciences - One Time Fuel Movement at the Armed Forces Radiobiology Research Institute Reactor Facility ML18318A3062018-11-0808 November 2018 Us Dept of Defense, Uniformed Services Univ. of the Health Sciences - Submittal of License Amendment Request (LAR) for Reactor Facility Director (Rfd) Qualification Tech Spec, Operations Minimum Staff Tech Spec, and Audit Function Tech Spec 2023-09-26
[Table view] |
Text
December 14, 2018 Captain John Gilstad, Director Armed Forces Radiobiology Research Institute National Naval Medical Center 8901 Wisconsin Avenue Bethesda, Maryland 20889-5603
SUBJECT:
ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE - ACCEPTANCE OF REQUESTED LICENSING ACTION REGARDING LICENSE AMENDMENT FOR CHANGING THE REQUIRED QUALIFICATIONS OF REACTOR FACILITY DIRECTOR FOR THE ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE REACTOR FACILITY (EPID NO. L-2018-LLA-0286)
Dear Captain Gilstad:
By letter dated November 8, 2018 (Agencywide Documents Access and Management System Accession No. ML18318A306), Armed Forces Radiobiology Research Institute (AFRRI) submitted a license amendment request (LAR) for the AFRRI reactor facility. AFRRI requested the amendment to revise its technical specifications to make two changes: (1) to allow it to change the qualifications of the reactor facility director, and (2) to change the frequency of reviews and audits of the Operator Requalification Program, Emergency Plan, and Physical Security Plan. AFRRI stated that the amendment is necessary to correct problems that resulted in the issuance of a Notice of Violation on July 5, 2018, as well as to ensure more safe and efficient reactor operation.
The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this LAR. The NRC staff performed this acceptance review to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the facility.
Consistent with Section 50.90, Application for amendment of license, construction permit, or early site permit, of Title 10 of the Code of Federal Regulations (10 CFR), whenever a holder of a license desires to amend the license, an application for an amendment must be filed with the Commission, as specified in 10 CFR 50.4, Written communications, fully describing the changes desired, and following as far as applicable, the form prescribed for original applications. Section 50.34, Contents of applications; technical information, of 10 CFR addresses the content of technical information required. This section stipulates that the submittal address the design and operating characteristics, unusual or novel design features, and principal safety considerations.
The NRC staff has reviewed AFRRIs application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review
J. Gilstad and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.
If you have any questions regarding this review, please contact me at 301-415-3398, or by electronic mail at Cindy.Montgomery@nrc.gov.
Sincerely,
/RA/
Cindy Montgomery, Project Manager Research and Test Reactors Licensing Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 50-170 License No. R-84 cc: See next page
Armed Forces Radiobiology Research Institute Docket No. 50-170 cc:
Director, Maryland Office of Planning 301 West Preston Street Baltimore, MD 21201 Montgomery County Executive 101 Monroe Street, 2nd Floor Rockville, MD 20850 Environmental Program Manager III Radiological Health Program Air & Radiation Management Adm.
Maryland Department of the Environment 1800 Washington Blvd., Suite 750 Baltimore, MD 21230-1724 Director Air & Radiation Management Adm.
Maryland Department of the Environment 1800 Washington Blvd., Suite 710 Baltimore, MD 21230 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611 Manager Nuclear Programs Maryland Department of Natural Resources Tawes B-3 Annapolis, MD 21401 Mr. Walter Dale Tomlinson Interim Reactor Facility Director Armed Forces Radiobiology Research Institute 4555 South Palmer Road, Building 42 Bethesda, MD 20889-5648
ML18347B385 *concurred via email OFFICE NRR/DLP/PRLB/PM* NRR/DLP/PRLB/LA* NRR/DLP/PRLB/BC NRR/DLP/PRLB/PM NAME CMontgomery NParker AAdams (WKennedy for) CMontgomery DATE 12/12/2018 12/13/2018 12/14/2018 12/14/2018