Technical Specification 5.6.5.d A member of the STARS Alliance LLC Callaway

  • Diablo Canyon
  • Palo Verde
  • Wolf Creek Palo Verde Nuclear Generating Station 5801 S. Wintersburg Road Tonopah, AZ 85354 102-07815-MDD/MSC December 5, 2018 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Reference:

Arizona Public Service Company letter number 102-07682, Unit 1 Core Operating Limits Report (COLR), Revision 25, Unit 2 COLR, Revision 21, and Unit 3 COLR, Revision 24, dated April 12, 2018 (ADAMS Accession No. ML18102B685)

Subject:

Palo Verde Nuclear Generating Station Unit 2 Docket Number STN 50-529 Renewed Operating License Number NPF-51 Current Core Operating Limits Report

Dear Sirs:

Pursuant to Palo Verde Nuclear Generating Station (PVNGS) Technical Specifications, Section 5.6.5.d, Arizona Public Service Company (APS) provided, in the referenced letter, the PVNGS Unit 2 Core Operating Limits Report (COLR), Revision 21. The PVNGS Unit 2 COLR, Revision 21, remains valid and is applicable for Unit 2 operating cycle 22, which began on December 3, 2018.

No commitments are being made to the NRC by this letter. Should you need further information regarding this submittal, please contact Matthew S. Cox, Licensing Section Leader, at (623) 393-5753.

Sincerely, Michael D. DiLorenzo Nuclear Regulatory Affairs Department Leader MDD/MSC/TMJ/mg cc:

K. M. Kennedy NRC Region IV Regional Administrator S. P. Lingam NRC NRR Project Manager for PVNGS M. M. OBanion NRC NRR Project Manager C. A. Peabody NRC Senior Resident Inspector for PVNGS Dilorenzo, Michael D(Z99838)

Digitally signed by Dilorenzo, Michael D(Z99838)

DN: cn=Dilorenzo, Michael D(Z99838)

Date: 2018.12.05 14:33:44 -07'00'