KING OF PRUSSIA, PA 19406-2713 November 14, 2018 Docket File WM-000042 Raymond J. Powell, Chief Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Briana G. DeBoer, Health Physicist Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety NRC OBSERVATIONAL SITE VISIT AT THE BURRELL, PENNSYLVANIA DISPOSAL SITE On October 9 and 10, 2018, a Region I U.S. Nuclear Regulatory Commission (NRC) inspector conducted an observational site visit at the U.S. Department of Energy's (DOE) Burrell, Pennsylvania Disposal Site near Blairsville, Indiana County, Pennsylvania. This site visit was conducted in accordance with NRC guidance dated September 7, 2012. The purpose of the site visit was to observe DOE's routine annual inspection of the facility and to observe groundwater sampling, which occurs every five years. The enclosure of this memorandum is the NRC's trip report for this observational site visit.
In summary, DOE representatives conducted the annual inspection in accordance with the guidance provided in the Long-Term Surveillance Plan dated April 2000. No significant regulatory issues or safety concerns were identified during the site visit.
Docket No.:
Enclosure:
NRC Trip Report cc w/encl:
Cliff Carpenter, Federal Project Director United States Department of Energy Office of Legacy Management 99 Research Park Road Morgantown, West Virginia 26505 CONTACT:
Briana DeBoer, RI/DNMS 610-337-5370
Memo to Docket File WM-000042 cc w/encl (cont'd):
Ken Broberg, Project Manager Navarro 2
Contractor to the U.S. Department of Energy Office of Legacy Management 10995 Hamilton-Cleaves Highway Harrison, Ohio 45030 David Allard, Director Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building PO Box 8469 Harrisburg, Pennsylvania 17105-8469 Dwight Shearer, RP Program Manager Pennsylvania Department of Environmental Protection SW Radiation Protection Division Southwest Regional Office 400 Waterfront Drive Pittsburgh, Pennsylvania 15222-4 7 45
Memo to Docket File WM-000042 3
NRC OBSERVATIONAL SITE VISIT AT THE BURRELL, PENNSYLVANIA DISPOSAL SITE DATED November 14, 2018 DISTRIBUTION:
VKurian, DUWP, NMSS DOrlando, DUWP, NMSS JTrapp, DNMS JNick, DNMS RPowell, DNMS MRoberts, DNMS BDeBoer, DNMS REvans, DNMS, Region IV DOCUMENT NAME: G:\\DIRHP\\UMTRCA DOE site observations\\Burrell Disposal Site Visit 2018.docx SUNSI Review Complete: BDeBoer After declaring this document "An Official Agency Record" it will be released to the Public.
To receive a co of this document, indicate in the box: "C" = Co w/o attach/encl 'E" = Co w/ attach/encl 'N" = No co OFFICE N
DNMS/RI N
NAME RPowell DATE OFFICIAL RECORD COPY
Docket:
Report:
Licensee:
Facility:
Location:
Date:
Inspector:
Approved by:
Attachment:
U.S. NUCLEAR REGULATORY COMMISSION REGION I WM-000042 WM-000042/18-001 U.S. Department of Energy Burrell, Pennsylvania Disposal Site Blairsville, Pennsylvania October 9-10, 2018 Briana DeBoer, Health Physicist Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Region I Raymond Powell, Chief Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Region I Photographs Taken at the Burrell, Pennsylvania Disposal Site Enclosure
NRC Trip Report
- 1.
Background
The licensing, custody, and long-term care requirements of residual radioactive material disposal sites closed under Title I of the Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978, as amended, can be found in 10 CFR 40.27. The U.S. Department of Energy (DOE) is the general licensee for these sites and conducts the program for the long-term surveillance and maintenance program for each inactive uranium ore processing site under a Long-Term Surveillance Plan (LTSP) that has been accepted by the NRC. The L TSP provides instructions for institutional control of the site. These controls include deed restrictions, site markers, survey monuments, boundary markers, gates, fences, signs and environmental sampling and analysis. The physical features of the site are inspected once per year by DOE staff. The "Long-Term Surveillance Plan for the U.S. Department of Energy Burrell Vicinity Property Blairsville, Pennsylvania," last revised in April 2000, provides the guidance for DOE in fulfilling the general license requirements.
The Burrell, Pennsylvania Disposal Site is a former railroad landfill located approximately one mile east of the Borough of Blairsville, Indiana County, Pennsylvania. The site is bordered on the south by the Conemaugh River and to the north by Norfolk Southern railroad tracks. The surrounding land is sparsely populated. The site was operated as a railroad landfill from the late 1940s through the late 1960s. The site was believed to have been used for typical railroad wastes, such as ties, cinders, and excess coal. In 1956 and 1957, approximately 11,600 tons of radioactive mill tailings material were removed from the former uranium ore processing site at Canonsburg, Pennsylvania, and transported approximately 50 miles to the Burrell site to be used as fill.
In 1986, the Federal government acquired the Burrell site through condemnation proceedings. Because of the large volume of material and the distance to the Canonsburg site, the DOE consolidated and encapsulated the contaminated material in an onsite disposal cell, designed to minimize precipitation infiltration and control erosion.
The cell was constructed by excavating the original fill material and consolidating this material with additional material that had been brought from the Canonsburg site. The disposal cell contains approximately 86,000 tons of material, containing four curies of radium-226 (Ra-226) and occupies approximately 4-5 acres of the 72-acre site. The disposal cell was closed in 1987.
The contaminated materials in the cell are covered by a low-permeability layer of compacted clay, a bedding layer, and a protective rock layer. The clay layer is designed to prevent the escape of radon-222 gas (from the decay of the Ra-226) and infiltration of precipitation. The bedding layer allows water to drain down the sloped cell top and the rock cover protects the cell surface against erosion. The area surrounding the cell is graded to promote drainage away from the disposal cell and was vegetated with native species to further prevent erosion. A chain link fence with warning signs surrounds the property to prevent unauthorized access. Locked gates allow for vehicle and pedestrian access. A site marker placed near the entrance of the site identifies the site and shows the date of closure and contents of the cell. Erosion control markers have been placed between the fence perimeter and the river. Contractors perform routine, periodic landscaping maintenance activities (primarily mowing and tree pruning along the fence) during the year.
2
- 2.
Site Status The DOE conducted the last annual inspection of the Burrell, Pennsylvania Disposal Site in October 2017. The inspection concluded that with the exception of a few minor maintenance items, the disposal cell and all associated drainage diversion structures were in good condition and functioning as designed. No evidence of erosion or slope instability were observed on the disposal cell.
The DOE monitors groundwater quality in samples from eight monitoring wells and two seeps from the cell every five years. Groundwater monitoring results from samples collected in November 2013 indicated that the disposal cell continues to isolate the contaminated waste from the groundwater environment. The last groundwater sampling event occurred on October 9 and 10, 2018, during the site visit, but analytical results are not yet available.
- 3.
Site Observations and Findings DOE and its contractors prepared an inspection checklist to identify items to review during the inspection. The checklist included requirements for the inspectors to observe the disposal cell, site perimeter, outlying areas, vegetation, and various site-specific features. The inspection staff included the DOE site manager and two contractors.
Inspection observer included two NRC representatives.
The DOE inspectors checked the disposal cell for evidence of erosion, settlement, slumping, displacement, and any other feature that would require maintenance or repair.
The rock surfaces on the side slopes were found to be in good condition. The DOE contractors did not authorize any inspection of the rock surfaces at the top of cell due to the potential for slip and fall injuries. Seeps from the base of the cell were not observed to be active.
At the time of the observational site visit, the property was enclosed by a chain link fence and locked gates. Other institutional controls in place at the site included the site marker, perimeter warning signs, and the erosion control markers. These institutional controls were found to be in place and in good condition, with minor exceptions. No deep-rooted vegetation was apparent on the top or side slopes of the cell that would impact cell performance. No evidence of human intrusion was identified within the restricted area.
The NRC inspector observed groundwater sampling at two of the monitoring wells on site. The inspector verified procedures and guidance for sampling groundwater monitoring wells were followed and all indicator parameters were met.
The NRC inspector measured the ambient gamma exposure rate at several locations using a Ludlum Model 19 micro R meter (NRC No. 82698, calibrated 01/16/18, calibration due date, 01/16/19). The background exposure rates ranged from 6-8 microRoentgens per hour (µR/hr). The exposure rates at the base of the disposal cell, adjacent to selected monitoring wells, and along the site perimeter fence, also ranged from 6-10 µR/hr and thus were not significantly different than background.
3
- 4.
Conclusions The NRC inspector concluded that the DOE inspectors conducted the site inspection in accordance with the requirements specified in the L TSP dated April 2000. The disposal cell appeared to be structurally intact, and the cover was in good condition. No threats to the integrity of the disposal cell were identified.
- 5.
Meeting Summary The NRC inspector participated in a planning meeting with the DOE site manager and site contractors prior to commencing the site inspection. During this meeting, the participants discussed the site status, the inspection plan, potential hazards, and personal protective equipment. At the conclusion of the inspection, the DOE site manager and site contractors noted the site status and recorded minor maintenance needs.
- 6.
Persons Contacted K. Broberg, Site Lead, Navarro C. Carpenter, Site Manager, DOE H. Swiger, Senior Environmental Scientist, Navarro 4
Figure 1: Burrell Disposal Cell (looking south)