NRC Licensed Facilities Prime Contract DE-EM0003976 Licensing Document Change Request STI-NLF-PM-029-01 LICENSING DOCUMENT CHANGE REQUEST age 0

P l

f2 Activity/Document No.: EDF-6932 Revision: O Facility:

(i.e., Activity initiating change)

Qsv

[Z}rM1-2 LDCR Number: NLF-LDCR-0007 Revision: Q OrsFF

Title:

TMl-2 ISFSI FSAR Changes to DSC Vent and Purge Port Configuration and Use I.

BACKGROUND Jeff Long

/1vti ~

t}-,J7

  • fl Preparer:

,,* /

A,-rvc.,.

Date:

Print

/

l *Sigiiature J

Independent i/

~

Reviewer:

Jim Stalnaker

~

Signature Date: 'i -?, 1,( ~

Print LOO:

Jeff Long

/LL!,{ -~

,9/ ',--/ \\..,t..,,

Date: °J-.17-/1 Print U ~nature

.If Reviewer:

(As Needed)

Date:

Print Signature II.

DESCRIPTION OF CHANGE FSAR Sections 3.1.2 and 4.3.10, Figure 4.3-1, and Appendix A FSAR Drawings 219-02-2000, 219-02-2001, 219-02-2002, 219-02-2003, 219-02-2010 and 219-02-2011 are revised, and Figure 4.3-2 is deleted. These changes are made to bring the FSAR information into alignment with the as-built design drawings for the 29 DSCs and the procedures/equipment involving the DSC purge and vent port assemblies for normal storage operations, seal testing, hydrogen sampling, and off-site transportation. A summary of these changes is attached below. Additionally, formatting and editorial corrections were made throughout each chapter including corrections to table numbering in Section 3.2 as reflected in the red-line markup.

The configuration of the vent and purge port assemblies during hydrogen sampling was modified by EDF-6932, but the FSAR was never updated to reflect these changes. New purge and vent port sample covers are depicted on INL Drawing 623548. The licensing documents only need to depict the normal storage configuration as shown on revised Figure 4.3-1. For the same reason, Figure 4.3-2 and a callout in the FSAR text, which depicted the sampling configuration that is no longer used, is being deleted. The Appendix A DSC FSAR drawings are also being modified to depict only the normal storage operation configuration. The FSAR text in Chapter 3 has also been clarified to explain the different purge and vent port configurations for the two different transfer casks in this regard.

CATS/MITS report number(s) applicable to documents identified during impact review: DR-2018-048 STI-NLF-PM-029 Rev 1 Page 11 of 12 Effective Date: December 15, 2017

~'hectra Tech 1nc.

STI-NLF-PM-029-01 LICENSING DOCUMENT CHANGE REQUEST FORM Activity/Document No.: EDF-6932 Revision: 0 (i.e., Activity initiating change)

LDCR Number: NLF-LDCR-0007 Revision: O Ill.

LICENSING DOCUMENTS NRC Licensed Facilities Prime Contract DE-EM0003976 Licensing Document Change Request Paoe 2 of 2 Facility:

DFSV

[l] TMJ-2 OrsFF Identify all licensing documents impacted by the proposed change below. Include the current revision of each and the Sections impacted by the proposed change, as applicable. Attach markups for each of the documents checked below. B License Rev.

Sections:

Technical Specifications Rev.

Sections:

Technical Specifications Basis Rev.

Sections:

Quality Assurance Program Rev.

Sections:

Emergency Response Plan Rev.

Sections:

Physical Protection Plan Rev.

Sections:

SPPP (FSV Only)

Rev.

Sections:

REMP Rev.

Sections:

Training Program Rev.

Sections:

~

Final Safety Analysis Report Rev. 9 Sections: See description Safeguard Information Protection Plan Rev.

Sections:

IV. APPROVAL

1. DYes [Z]No Safety Review Committee review required?

(Required for all proposed license amendment requests and any other changes as directed by the DOE-ID Facility Director).

If Yes:

I I

Print Safety Review Committee Chair SRC Meeting No./Datc

2. [Z]Yes DNo DOE-ID Facility Director Approval Required?

(Required for changes that require evaluation pursuant to 10 CFR 72.44(e),

\\<: v'\\v vl 10 CFR 72.44(f), 10 CFR 72.48, and Technical Specifications 5.5.1.b and 5.5.2.3).

~p} c"°~ wi

  • hlil~f No:

I

/

I Print

~o'gram Manager Date

'/ - n-1?

If Yes:

Scott Ferrara I ~~s~~ctor I

1-~

Print Date

3. DYes [Z]No Implementation pending? - See Comments (e.g., NRC approval required, etc.).

Comments: These are considered administrative changes that should have been made when EDF-6932 was approved and implemented.

STI-NLF-PM-029 Rev 1 Page 12 of 12 Effective Date: December 15, 2017

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.1-3 on a total decay heat of 860 watts. The thermal analysis of the DSC internals which include TMI-2 canisters with core debris is conservatively based on 80 watts/canister decay heat load.

This heat load is sufficiently low that the DSC and HSM are fully capable of dissipating the heat and keeping all temperatures within the recommended material temperature limits without the need for HSM cooling air vents.

3.1.1.3 Radiological Characteristics The maximum initial enrichment of the TMI-2 fuel was 2.98 weight percent (w/o) U-235. The TMI-2 core has a fuel burnup of 3,175 MWD/MTU and a cooling time of 19 years. A summary of the TMI-2 canister radiological characteristics is provided in Table 3.1-3.

3.1.2 General Operating Functions The general operating functions described below are applicable for the NRC 10 CFR 71 certified MP-187 transportation system. Appendix E provides the general operating functions for the 10 CFR 72 approved OS-197 Transfer Cask. The major difference between the two transportation approaches is that the NRC 10 CFR 72 approved OS-197 Transfer Cask does not require impact limiters, evacuation and helium backfill of the DSC, leak testing of the DSC closure weld, or installation of the vent/filter housing transportation covers.

The INL TMI-2 ISFSI is designed to maximize the use of existing INL facilities and equipment at INTEC and TAN, and to minimize the need to add or modify equipment. The ISFSI will be located within the existing INL security boundary.

Services such as security, maintenance, training and emergency response will be performed by the M&O Contractor. The power provided for the ISFSI security system and lighting is obtained from the INTEC electrical grid. Other support services from INL are necessary only during DSC transfer and retrieval operations.

A brief description of the general operation of the system begins with an empty DSC and cask which have been prepared for loading and TMI-2 canisters which have been drained and dried and prepared for insertion into the DSC. During loading of the TMI-2 canisters into the DSC, the DSC rests in the cavity of the cask inside the TAN Hot Shop. The DSC will be sealed and then purged and backfilled with helium for leak testing. After purging, the DSC (still inside the cask) will be moved to the cask skid/trailer and transported to the ISFSI. The DSC will be pushed from the cask into the HSM by a hydraulic ram. The HSM rests on, but is not anchored to, a concrete ISFSI basemat.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.1-4 The DSC is sealed to ensure that any flow of gases in or out of the DSC, during storage, is through a HEPA filter. This is accomplished by welding the closure plates in place and leak testing the welds. The inner cover is welded and inspected to the same criteria as the outer cover plate. The plates are welded to the shell and seal welded together at the purge and vent ports to provide redundant closures.

Both the purge and vent ports are covered with vent housings that are sealed to the outer cover plate with dual metallic seals. During leak testing and transfer/transport activities the filters are closed by installing cover plates which are sealed to the vent housings with dual metallic seals.

Normal storage operations, seal leak testing, hydrogen sampling, DSC purging, on-site transport/transfer (under 10 CFR 72), and off-site transport (under 10 CFR 71) require different configurations of the DSC purge and vent port assemblies. During normal storage operations, the DSC cavity communicates with the HSM internal space via one HEPA filter in the purge port assembly and four filters in the vent port assembly. The purge and vent port assemblies are each normally protected by a dust cover. See drawings 219-02-2010 and -2011 in Appendix A for detailed depictions of the normal storage configuration of the purge and vent port assemblies. Other DSC configurations and subcomponents not used for normal storage operations discussed below (i.e., testing, sampling, purging, or offsite transportation) are not represented on the DSC FSAR drawings in Appendix A but are retained on DSC design drawings 219-02-1010 and 219-02-1011 to ensure configuration control.

For testing of the dual metallic seals beneath the purge and vent port housings, the dust cover is removed and a seal test port, which is normally plugged, is used to access the space between the concentric seals for testing.

For DSC hydrogen sampling, the dust cover is removed from the vent port assembly and a specially-designed sampling cover is installed that allows a sample of the DSC cavity gas to be drawn through the HEPA filters. The HEPA filters have no effect on the DSC cavity hydrogen concentration because it is an inert gas.

For DSC purging, the dust cover is removed from the purge port assembly, a specially-designed cover is installed, and purging gas is introduced to the DSC cavity.

On-site transport/transfer governed by 10 CFR 72 may be conducted using the MP187 transport cask as described in Section 5.1.1 or using the OS197 transfer cask, as described in Appendix E, Section E5. The configuration of the purge and vent port assemblies varies slightly for these operations, depending on whether the MP187 cask or the OS197 cask is used. As described in Section 5.1.1, a transportation cover is required to be installed over the purge and vent port assemblies if the MP187 cask is used for on-site transport/transfer operations.

Transportation covers are not required to be installed over the purge and vent port assemblies if the OS197 cask is used for on-site transport/transfer operations. This configuration is described in Appendix E, Section E5.

For future off-site transportation, the requirements of the applicable 10 CFR 71 Certification of Compliance (CoC) and its associated Safety Analysis Report apply

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.1-5 for preparing the DSC for shipping inside a separate outer packaging. This configuration is not discussed further here because it is not germane to ISFSI operations or otherwise governed by the 10 CFR 72 regulations.

Acceptance leak testing is done with the DSC inside the cask by pulling a vacuum in the DSC, back filling with helium, sealing the cask, then pulling a vacuum in the annulus between the cask and the DSC with the discharge routed through a helium leak detector. When the DSC is placed in the HSM, the test/transport covers, if used, are removed to allow the DSC to vent to atmosphere, thereby, removing radiolytically generated hydrogen from any residual moisture contained inside the DSC. The HEPA filters are screwed into the filter housing using a single elastomeric gasket under the flange of the filters. Filters are sintered stainless steel encased in stainless steel bodies originally developed for long term hydrogen gas venting of radiological waste containers. There are four, two-inch diameter filters located in the vent cover housing and one, two inch diameter filter located in the purge port vent cover housing. The vent port accesses the DSC in the headspace immediately above the top of the TMI canisters. This allows for direct removal of any gases emitted by the canisters. The purge port connects to a mechanical tube that goes to the bottom of the DSC to allow for gas circulation in the system. This also allows for complete purging of the DSC if, as discussed in section 4.3, any abnormally high gas build-ups are noted. Both the purge port filter and vent port filter housings allow for sampling of gases within the DSC. Additionally, the test/transport covers can be installed over the filters to allow equalization of gases within the DSC so representative gas samples can be obtained. The filter housings also have leak test ports for remotely testing the filter housing to DSC seals. The vent and purge ports can be accessed through the rear of the HSM during DSC storage. The HSM filter access ports exit the HSM rear wall through a vented steel door. The internal location of the filters and the heavy steel door that protects the access to the filters ensures safe operation of the filters.

The filters are constructed entirely from stainless steel. The filter media is sintered stainless steel that is certified by the supplier to have an efficiency of greater than 99.97% for particulate down to 0.3 microns. This material is welded into the threaded stainless steel filter body which in turn is threaded into the filter housings.

The filter assembly before installation into the housing is also checked for filtration efficiency. This filter is completely passive and is constructed of stainless steel making in unaffected by the environment it will see at INL.

Once inside the HSM, the DSC and its payload of TMI-2 canisters will be in passive dry storage. Safe storage in the HSM is assured by passive heat transfer and massive concrete walls and slabs which act as biological radiation shields. The storage operation of the HSMs and DSCs is passive except for monitoring, surveillance, and/or purging of the DSC, and vent system HEPA grade filter change out if hydrogen gas build-up is detected. Chapter 5 addresses the operating steps in more detail.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-5 DSC and HSM vertical frequency is 67.9 Hertz, which results in a vertical seismic design acceleration of 0.24g. The resulting seismic design accelerations used for the DSC are.49g horizontally and 0.24g vertically.

3.2.4 Snow and Ice Loads The maximum 100 year roof snow load, specified for the INL TMI-2 ISFSI location for an unheated structure, is 1.4 kN/m2 (30 psf). This value is conservative as compared to 18.1 psf calculated using the formula Pf = 0.7CeCtIPg =

0.7x0.9x1.2x1.2x20 = 18.1 psf from ANSI A58.1-1982, Tables 18 through 20. For the purpose of this SAR, a total live load of 6.24 kN/m2 (130 psf) is used in the HSM analysis to envelope all postulated live loadings, including snow and ice.

3.2.5 Load Combination Criteria 3.2.5.1 Horizontal Storage Module The INL TMI-2 ISFSI reinforced concrete HSM is designed to meet the requirements of ACI 349 [3.18] and is constructed to ACI 318 [3.19]. The ultimate strength method of analysis is utilized with the appropriate strength reduction factors as described in Table 3.2-2Table 3.2-3. The load combinations specified in Section 6.17.3.1 of ANSI 57.9-1984 are used for combining normal operating, off-normal, and accident loads for the HSM. All seven load combinations specified are considered and the governing combinations are selected for detailed design and analysis. The HSM design load combinations and the appropriate load factors are presented in Table 3.2-3Table 3.2-4. The effects of duty cycle on the HSM are considered and found to have negligible effect on the design.

The corresponding structural design criteria and load combination methodology for the DSC support structure are summarized in Table 3.2-5Table 3.2-6 and Table 3.2-7Table 3.2-8 [3.21]. The HSM load combination results are presented in Section 8.3.5.

3.2.5.2 Dry Shielded Canister The DSC shell and closure plates are designed by analysis to meet the allowables of the ASME Boiler and Pressure Vessel Code [3.20] Section III, Division l, Subsection NB. The DSC shell and closure plates are conservatively designed utilizing linear elastic or non-linear elastic-plastic analysis methods. The load combinations considered for the DSC shell and closure plates normal, off-normal and postulated accident loadings are shown in Table 3.2-4Table 3.2-5. ASME Code Service Level A and B allowables are conservatively used for normal and off-normal operating conditions. Service Level C and D allowables are used for accident conditions such as a postulated cask drop accident. Using this acceptance

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-6 criteria ensures that, in the event of a design basis drop accident, the confinement boundary will not be breached. The maximum shear stress theory is used to calculate principal stresses. Normal operational stresses are combined with the appropriate off-normal and accident stresses. It is assumed that only one postulated accident condition occurs at any one time. The accident analyses are documented in Section 8.2. The structural design criteria for the DSC shell and closure plates are summarized in Table 3.2-6Table 3.2-7. The effects of fatigue on the DSC shell and closure plates due to thermal and pressure cycling are addressed in Section 8.3.

The internal support structure is designed to maintain its geometric arrangement for normal operating events. There are no design requirements for the internal structure for postulated accident events. The DSC internal support structure is not required to maintain criticality control of the TMI-2 canisters.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-12 Table 3.2-23 HSM Ultimate Strength Reduction Factors TYPE OF STRESS REDUCTION FACTOR Flexure 0.9 Axial Tension 0.9 Axial Compression 0.7 Shear 0.85 Torsion 0.85 Bearing 0.7

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-13 Table 3.2-3 4 HSM Load Combination Methodology Case No.

Load Combination(1)

Loading Notation 1

1.4D + 1.7L D =

Dead Weight(2) 2 1.4D + 1.7L + 1.7Ro E =

Earthquake Load 3

0.75 (1.4D + 1.7L + 1.7T +

1.7W)

Ro and Ra = Normal and Off-normal Handling Loads.

4 0.75 (1.4D + 1.7L + 1.7T) 5 D + L + To + E L =

Live Load(3) 6 D + L + To + Wt To and Ta =

Normal, Off-normal or Accident Condition Thermal Load 7

D + L + Ra + Ta Wt = Tornado Generated Wind Load(4)

W = Wind Load

1. The HSM load combinations are in accordance with ANSI-57.9-1984. The effect of creep and shrinkage are included in dead weight load for Cases 2 through 7.
2. Dead loads (D) are evaluated for 5% to simulate most adverse loading.
3. Live loads (L) are varied between 0 and 100% of design load to simulate most adverse conditions for the HSM.
4. Design Basis Tornado loads include wind pressure, differential pressure, and missile loads. Missile loads are additive to wind pressure and other loads. Local damage is permitted at the point of impact if there is no loss of intended function on any structure important to safety.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-14 Table 3.2-4 5 DSC Shell and Closure Plates Load Combinations and Service Levels Load Case Test Condi-tions (3)

Normal Operating Conditions Off-Normal Conditions Accident Conditions A1 A2 A3 A4 B1 B2 B3 B4 D1 D2 C1 C2 C3 C4 C5 C6 Dead Weight Vertical, DSC Empty Vertical, DSC w/Fuel Horizontal, DSC w/Fuel X

X X

X X

X X

X X

X X

X X

X X

X X

Thermal Inside HSM: -20 to 87F Inside Cask: -20 to 87F Inside HSM: -50 to 103F Inside Cask: -50F to 103F X

X X

X X

X X

X X

X X

X X

X X

X Internal Pressure Normal Pressure Off-Normal Pressure Accident Pressure X

X X

X X

X X

X X

X(2)

X X(2)

X(3)

X(2)

X(2)

Test Pressure X

Handling Loads Normal DSC Transfer Jammed DSC Loads X

X X

X X

X X

X Cask Drop (end, side, or corner drop)

Seismic Flooding X

X X

ASME Code Service Level (1)

A A

A A

B B

B B

D D

C C

C C

C C

NOTES:

1. The stress limits of NB-3226 apply.
2. Accident pressure for Service Level C condition is applied to inner closure plates. Accident pressures on the outer closure plates are evaluated for Service Level D allowables.
3. Test conditions include pressure during ASME Code hydrostatic test.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-15 Table 3.2-56 DSC Support Structure Load Combination Methodology Allowable Stress (S)(4)

Case No.

Load Combination(1) 1 S > D(2) + L(3) 2 S > D + L + Ro 3

1.33S > D + L + W 4

1.5S > D + L + T + W 5

1.33S > D + L + T + Ra 6

1.6S > D + L + To + E 7

1.33S > D + L + Ra + Ta

1. Load combinations are per ANSI 57. For definitions of loads see Table 3.2-4.
2. Dead load (D) includes weight of loaded DSC and is increased +5% to simulate most adverse loading.
3. Live load is varied 0 - 100% to obtain critical section.
4. Maximum shear stress allowable is limited to 1.4 S.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-16 Table 3.2-6 7 Structural Design Criteria for DSC Stress Values(1)

Stress Type Service Levels A & B Service Level C Service Level D DSC(2)

Shell &

Closure Plates Primary Membrane Sm Greater of 1.2 Sm or Sy Smaller of 2.4 Sm or 0.7 Su Primary Membrane +

Bending 1.5 Sm Smaller of 1.8 Sm or 1.5 Sy Smaller of 3.6 Sm or Su Primary +

Secondary 3.0 Sm N/A N/A DSC Fillet Welds Primary 0.50 Sm Greater of 0.65 Sm or 0.50 Sy Smaller of 1.2 Sm or 0.35 Su Primary +

Secondary 0.75 Sm Smaller of 0.9 Sm or 0.75 Sy N/A

1. Values of Sy, Sm, and Su versus temperature are given in Table 8.1-3.
2. Includes full penetration volumetrically inspected welds.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 3 Rev. 6 Page 3.2-17 Table 3.2-7 8 Structural Design Criteria for DSC Support Structure Allowable Stress (S)

Stress Type Stress Value(1)

Tensile 0.60 Sy (2)

Compressive (See Note 2)

Bending 0.60 Sy (3)

Shear 0.40 Sy (4)

Interaction (See Note 5)

1.

Values of Sy versus temperature are given in Table 8.1-3.

2.

Equations E2-1 or E2-2 of the AISC Specification [3.13] are used as appropriate.

3.

If the requirements of Paragraph F1.1 are met, an allowable bending stress of 0.6 Sy is used.

4.

Maximum allowable shear stress for Cases 4 to 7 is limited to 1.4S (0.56 Sy)

5.

Interaction equations per the AISC Specification are used as appropriate

[3.21].

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-4 4.3.3 Air Supply System An air supply system is not required for any Important to Safety DSC loading or purging operations. Plant air may be utilized for general loading activities. Any plant air that could gain access to the DSC or TMI-2 canisters is free of oil.

4.3.4 Steam Supply and Distribution System There are no steam systems utilized.

4.3.5 Water Supply System Demineralized water may be needed for the MP187 cask washdown operations. If used, this water will be supplied by existing systems at the TAN facility and are not part of this licensing application.

4.3.6 Sewage Treatment System There are no sewage treatment systems required for the TMI-2 ISFSI.

4.3.7 Communication and Alarm Systems No communication systems are required for the safe operation of the TMI-2 ISFSI. The existing plant paging and telephone system may be extended to the ISFSI during transfer operations. The ISFSI security alarm system is described in the ISFSI Security Plan which is being submitted under separate cover.

4.3.8 Fire Protection System No fire detection or suppression system is required for the TMI-2 ISFSI. The HSMs contain no combustible materials. The provisions needed for fire response will be provided consistent with existing INTEC requirements.

4.3.9 Cold Chemical Systems There are no cold chemical systems for the TMI-2 ISFSI.

4.3.10 Air Sampling System The capability of air sampling ahead of the vent system HEPA filters allows for monitoring the gas generation inside the DSCs. There are two sampling systems used at the ISFSI for monitoring the gas generation inside the DSCs. One is an air particulate sampling system to periodically check air for activity as it leaves the vents. This system is portable to allow periodic checks. When the DSC is sampled for hydrogen, a cover with double metalic seals is placed over the HEPA filters and then a sample pulled through a fitting in the cover. At the completion of the sampling, the cover is replaced with the dust cover. Figure 4.3-2 shows an alternative configuration for the sampling system.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-5 Sampling the air downstream from the HEPA filters allows efficient monitoring while ensuring that no significant particles are released. Any airborne activity which may occur during TMI-2 canister loading and DSC closure operations is monitored by the existing TAN Hot Shop ventilation and radiological detection systems.

4.3.11 Maintenance System The maintenance system consists of a testing program to verify there is no abnormal radioactive release, sampling of the DSC for hydrogen build-up, and periodic testing of the mechanical seals attaching the vent housings to the DSC. The maintenance program includes ensuring the vent access doors remain operational and no blockage occurs in the vent areas of the door.

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-6

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-7 Figure 4.3-1 DSC Vent and Purge Assemblies

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-1 Figure 4.3-1 DSC Vent and Purge Assemblies (Concluded)

TMI-2 SAR-II-8.4 DRAFT x/xx/18 Chapter 4 Rev. 7 Page 4.3-2 Figure 4.3-2 DSC Sampling System

DSC FSAR DRAWING CHANGES General: The document to be referenced for all of these changes is NLF-LDCR-007. All sheets of all affected drawings need to have the revision level increased appropriately. The title block of all sheets of all drawings should be modified to remove "Engineering" so that it states "Idaho National Labo1iaory."

DSC Basket-Shell Assembly FSAR Drawing, 219-02-2002, Sheet 2 Change:

In Detail 2, change the section from "D-D" to "E-E." and change the title of the section view to the left of Detail 2 from "Section D-D" to "Section E-E."

DSC Main Assembly FSAR Drawing 219-02-2003, Sheet 1 Change:

Section A-A: At the right side, change "219-02-2012" to "219-02-2011."

DSC Main Assembly FSAR Drawing 219-02-2003, Sheet 3 Change:

View G-G: Change "Items 9 to "Item 9."

Purge Port FSAR Drawing 219-02-2010, Sheet 1, Parts List Change:

Show Items 8 and 9 as "Not Used," and Items 2, 11, 12, 15, 17, 18, and 19 as "not used for nonnal storage operation."

Purge Port FSAR Drawing 219-02-2010, Sheet 1, Sections G-4 to G-7 Changes: 1. Delete the Purge Assembly Sample/Transport Configuration and Section A-A details in their entirety.

2. Move the bolt shown at the bottom of Section A-A to the bottom of Section B-B.

Purge Port FSAR Drawing 219-02-2010, Sheet 1 Section C-4 to C-7 Changes: 1. Purge Assembly Storage Configuration: Add a callout for Note 8 near Item 16.

2. Purge Assembly Storage Configuration: Show the bottom end of Section B-B bisecting the bolt at the 5 o'clock position (as currently shown in Section A-A).
3. Purge Assembly Storage Configuration: Beneath "Seal Test P01i," add

"(normally plugged)."

4. Section B-B: Move the bottom bolt currently shown in Section A-A to Section B-B.
5. Change "Purge Assembly Storage Configuration" to "Purge Assembly Normal Storage Operation Configuration."

Purge Port FSAR Drawing 219-02-2010, Sheet l, Notes Changes:

1. Revise Note 8 to replace "Items 15 and 16" with "Item 16."
2. Add new Note 10 to say: "See design drawing 219-02-1010 for additional parts and configurations not used for normal storage operation."

DSC FSAR DRAWING CHANGES Purge Port FSAR Drawing 219-02-2010, Sheet 2, Section E-4 to E-8 Changes:

1. Delete the Side View and Sample/Transp011 Cover Sub-Assembly in their entirety.
2. Section D-D: Delete the depiction ofltems 8 and 9, including tubing stub-out, and re-label the penetration as "Seal Test Port." Add "(nonnally plugged)"

underneath.

Vent Port FSAR Drawing 219-02-2011, Sheet 1, Parts List Changes: 1. Show Items 8 and 9 as "Not Used," and Items 2, 11, 12, 15, 17, 18, and 19 as "not used for normal storage operation."

2. Change the classification for item 5 from "NIA" to "A."

Vent Port FSAR Drawing 219-02-2011, Sheet 1, Sections F-4 to F-7 Change:

Delete Vent Assembly Sampling and Transport Configuration and Section A-A in their entirety.

Vent Port FSAR Drawing 219-02-2011, Sheet 1, Notes Changes:

1. Revise Note 8 to replace "Items 15 and 16" with "Item 16."
2. Add new Note 10 to say: "See design drawing 219-02-1011 for additional parts and configurations not used for normal storage operation."

Vent Port FSAR Drawing 219-02-2011, Sheet 1, Section C-7 Changes: 1. Vent Assembly Storage Configuration: Remove parentheses around "Seal Test Port" and add "(nonnally plugged)" below.

2. Change "Vent Assembly Storage Configuration" to "Vent Assembly Normal Storage Operation Configuration."

Vent Port FSAR Drawing 219-02-2011, Sheet 2, Sections A-7 to E-7 Changes:

1. Section F-F: Delete depiction ofltems 8 and 9, including the tube stub-out and re-label the penetration as "Seal Test Port." Add "(norn1ally plugged)" beneath.
2. Delete Cover Sub-Assembly and Section K-K in their entirety.