Text

For Information Only 6

& REMOVE To OE-WAT£R 6 INSTALL CAP ON OUTLET FITTING: AFTER. DE-WATE:RINGi L

!. *.!. r Iii, -

~'!.

TII.Ci<: WELD P/N 7 A':.

REQUIRED TO P/N 2>

,~----

[!:~1! RE.F. DIA.

INSTALL CAP ON Pl,IR<:.E. t;;:Y

- FITTIIIC.

  • ftFTf'.R

'<:!.)

Oc*WA'TE.R/Nli NOT'/: 7

  • TOl'\\G,UE. 801..T&

40 TO l'>O rT,*/..BS, TVR 6*F'/..ACl:S &

.see l'lo?"e' 10 CD FUE.l C~N\\STE.R A. SS E.M SL"(

ISO MA)(

REF

6.

NI ELAST01£RIC SEAL MAY BE USED FOR HY!JlOTEST BUT NJST BE REl<<lVEO f'Rllll TO OPERATION OF CANISTER.

7.

APPLY Bl.T THREAD LUBRICANT, FEl.Pll? NUCLEAR GRADE N*&IOO, PER ll>M.l'ACTIJIERS INSTRU:TillNS, THE Ill. TS SHALL BE TORCI.Ell IN A STAR SEIJ,ENCE INITIALLY TO 5*10 FT*LBS Fa.LCIIIED BY A SEOUEt,CE AT 40.50 FT*LBS.

B.

ASSEIB.Y IE.DING, ASSEIB.Y, CLEANING, INSPECTION, PACKAGING, SHlPMElfT Mil STORAGE 5HALL. BE IN Al'ADRDANCE WITH SPEC, 27

  • 1153607, 2

I REVISIONS 1\\54070 F' FUEL C.A.JJ. 0...55 1'{

?

I 11soqqqe, LOWE.P. "-SS'y 3

I i154026F HE.A.D WELDM'T. ?1>.ss's 4

I Jl54075C CAP 1'.SS'Y (PU~e,E./ IN.L.E.T) 5 I 115'1-086C CA.P A.SS'i (0£~-... ~-R-_-0-UT-L-ET-)!----~~f, 6 AR./151-07GC RELIEFVALVE ASS'Y.(/NL£T)

& r I

IIS4IOG,B NA.ME PL""-TE NOTES:

1. THIS PRESSURE VESSEL CONSISTS OF A MATCHED SET OF PART NO. 2 MO PART NO. 3 WITH IOENTICAL SERIAL NlMlERS.
2. TilIS PRESSURE VESSEL SHALL 6E PROCURED, FABRICATED, INSPECTED, CERTIFIED, ANIJ STAWED IN ACCORO.INCE NITH SECTION VIII, DIVISION l OF 1HE ASME BOILER &

P!!ESSURE VESSEL CODE 1983 EDITION WITH NO AOOENOA FCR A "lETilAL" VESSEL.

3. A HYCROTEST SHAU. BE PERFORMED AT 225 PSIG FOR A PERIOD MJT LESS THAN 30 MINUTES, 11£ TEST SHALL 6E Pff!FORMEO IN ACCORDANCE WITH PARAGRAPH IXl-99 OF THE ASME CO~E, 11£ LEAKAGE CRITERIA SHALL BE PER CUS'TIMR REQUIREMENTS.
4.

AFTER SUCCESSFU. COf'LETION OF THE HYORO!EST ANO ALL SPECIFIED INSPECTIONS, THE VESSEL NAIE'LATE S/iALI.. EE STAMPED Mil THE NAIEPLATE SHALL BE INSTALLED IN THE POSITIOII Sf()NN, to FURTHER FABRICATION ?F ANY KIND IS PERMITTED.

(PER PARAGRAPH UG-116),

5., REPLACE.,SEALS IN PIN 3 AFTER HVDROTEST.

ASSEMBLY FUEL CANISTER 1-!!!W~!!!!!,µ=t IM.l-2 DE-FUELi NG JHf ~:,~~:utu:I~~: CO.

t~~::c:~~~:: *;-Ji~. r~~Gz: