ML18283B240
| ML18283B240 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry (DPR-033, DPR-052) |
| Issue date: | 04/05/1976 |
| From: | Green H Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML18283B240 (16) | |
Text
NRC FOIi&I 195 I2.76)
TO:
'HRC Tennessee Yal1 ey Authority
- Decatur, Alabama H.J.
Green U.S. NUCLFAR REGULATORY'COMM ON NRC DlsTRIBUTION FDR PART 60 DOCKET MATER(AL DOCKET NUMOE 50-25 26 FILE NUMIIER MONTHLY REPORT DATE OF DOCUMENT 4-5-76 DATE RECEIVED 4-12-76 QLETTER ORIGINAL COP Y ClNOTORIZED P(UNC LASS I F I E D PROP INPUT FORM NUMBER OF COPIES RECEIVED DESCRIPTION LETTER TRANS TIIE FOLLOWING:
16 PLANT & OOMPONENZ OPEEABLLTTT
&'UAILABILITY
~
TlHS REPORT TO BE USED IN PREPARING GRAY BOUC BY PLANS 6 OPERATIONS.
PLANT NAME:
Brogans Ferry P,
1 8
2 MIPC W
CYS POR AC 'N FOR ACTION/INFORMATION INTERNALDISTRIBUTION NRC PDR
~HAPM BRANCH CHIEP L Pur le She ard METE.~hons 74SX'X'I ERNAL DISTRIBUTION CO TROL NUi'JIBER 3624
0 d
4
I Filo Cy, TENNESSEE VALLEY AUTHORI't Y Browns Perry Nuclear Plant:
P. 0.
Box 2000 Deca t.'ur, Alaban(8<~5603 Regulatory
'pril 5,
1976 Nuclear Regulatory Commission Office of Management: Information and Progxam Contxol Tfashington, D. C.t 20545 Gentlemen:
Enclosed is the March 1976 report on plant and component operabilit:y and availability for Browns Perry Nuclear Plant units 1 and 2.
Very truly yours,
. TENNESSE VALLEY AUTHORITY H. J. Preen Plant Superintendent hlgp !.
Pee'qi O'~>
Enclosures:
2 CC:
Nuclear Regulatory Commission Office of Inspection and Enfoxcement 230 Peachtree
- Street,
Ã0 Suite 818 Atlanta, Georgia 30303
~~lr t E
'p','3
~ i An Equal Opportunity Employer
~ ! ~!
0 vl ~ ~
t k
C OPEHATIIIG STATUS:
emens Ferry 1 DATR '/:./76 pY e }tctrold I'lalls 1%le "bTT 1065 N/A 3e POUER LEVEL TO NHXCII RESTRICTED (XF ANY) e 4. REASONS FOR'RESTRICTIONS ( XF ANY): 1, REPO+TltlG PERXOD: 0000760301 TO 2400760331 GROSS }10URS Xtt REPORTING PER10D: 744 2~ CURRENTLY AUT}IORIZED POWER LEVEL Raft HOURS P~KCTOR hYtS CHXTICAL............... 6. REACTOR RESERVE S}!UTDOV~7 HOURS........... 7. }IOIJRS GENERATOR ON-LXIfZ.................. 8. UNXT RESERVE SiiJTDOÃI HOURS 9-GROSS THEBtQtL PO'~ G" flWATZD {INH)...... 10. GBOSS~~ECTRXCAL PO>/ER Gr.;cCATED (ttt<}I)(5) 11 NBP ELZCTRXCAL POn ~W GENERATED (IO'K ) ~ TIIIS <<!ON'IH 0 0 0 0 0 2 j331 0 0 0, 7~7. 036~32 0 ~7091 570 -1.3,855 6,820,317 CUt EMULATIVE YR-TO.DATE TO DATE 0 9,870.02 0 '26.10 0 9 282.80 12. 13. ~ , 3.4. 1> 16. REACTOR AVAXLA3ILITYFACTOR (1) UIIXT USE FACTOR (2).... ~ ~ ~ ; ~, ~ ~.+ ~ ~ ~ ~ UI/XT CPJACITY FACTOR (3 ) o ~ r ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o FORCED OUTAGi/ RATE (4) ~ ~ ~ ~ ~ ~ ~ ~ - ~ $ }IUTDONNS SCHEDULED TO BEGIN IN tiEXT 6 MONTIIS (STATE 0 100 TYPE~ DATE AtiD 30.3 53.6 0 45.8 0 '3 DUPiATXON OF EAC}I): 17. XF S}IUTDOHN AT END OF REPORT PERIOD, ESTD!ATED DATE OF STARTUP: 18. PLAtiTS XN TEST STATUS (PRIOR TO COI'a~ERCIAL OPEPJtTION) REPORT THE FOLLC'iXNG: ~ . DATE LAST DATE. REASON FOR FORECAST . AC1IXEVED DIFFERENCE INXTIALCRITICALITY INXTXALELECTRICAL POPER GEttEFchTION CO>RIERCIAL OPERATION (1) REACTOR AVAILABILITYI'ACTOR " IIOURS RL'ACTOR HAS CRITICAL ~:100'ROSS }lOURS IiN REPORTING PERIOD (2) lfrtXY.'SE FACTOR - }IOURS GEt<EFNTOR ON-I,II<E +100 GIIOSS llOURS It< REPORTItNG PERIOD (3) UNXT CAPACITY FACTOFi " NET ELECTFiICAL POINTER GEVZRATED CUI'}tEHTLY LICENSEI) PO'<EFi LEVi'.L GROSS I}OURS IN FJ POFTING PERi .'4) FORCED OUTAGE RATE - FORCI D OUTAGE 110ltRS +100 }IOURS GEttt'RATOR. ON LIVE + FOliCED OUTAGE llOUFS (5) DOES NOT INCLUDE AUXILXA}'YDXESEL GENEF "tTION
C
U12"d.RY: Unit renained in cold shutdown for repair of control ca'ole DATE 4/1/76 CO>lPLETED gv Harold kla13,s UNIT NQK Browns 1'errv Nuclear REPORT YiORiii 'arch PLANT SHUTDOWNS NO. TYPE r -1'ORCED S "SCiDDULED DURATION HOURS) REASON 1 .METHOD OP "S11UTTIilG DOMH TilE R"ACTOR 2 CCiBFNTS 760301 696 (1) REASON: A-EQUIPiZNT PAILUR" (EXPLAIN) B-~ilAINT, OR TEST. C-REFUELING D-REGULATORY RESTRICTION E-OPERATOR TRAINING AND'ICENSING EXAMINATION 'P-ADMINISTRATIVE G-OPERATIONAL ERROR (EXPLAIN) (2) JEir.OD: A-~a&hNUAL' -'.USUAL C-AU'~'KT SCR:Ql
0
Brogans I'erry l ,, ~ 4/7./76 COHPLEXVD BY - llarold Halls MONT17 1 larch DAILY UtlIT POHER OUTPUT .2'VERAGE DAILY -4.2 -4.7 l "H7e -ne t 25 26 AVERAGE DAILYl4"le<<net -4.4 -3.0 9 10'2 13 15 16 17 18 19 20 21 22 23 24 -5.8 -4.2 -4.2 -4.6 -4.2 -4.4 -4. 2 -4. 2 4,4 -4. 4 .4.9 -4.2 -4.0 -4.8 -4.7 -4.0 -4.8 .-4..5 -4. 0 -5.0 -4. 5 -4.8 27 29 30 31 -3.8 -4.7 -3.5 -5.0 7 ~ 7 Note: Negative values indicate statioa use'hen unit is off line. ~ ~
lI
OPEnATXIJG STATUS: U11XT ?00)E Brovns Fear'J 2 Coi PLEiED BY: I'" 1, REPORTXNG PERIOD: o000760301 TO'400760331 GROSS IIOURS IN REPORTING PERIOD: 744 2, CURRENTLY AUTIIORXZED PO)JER LEVEL MJt .3293 )Me-NET >065 PotJER LEVEL To tJ1IICII RESTiiICTED (IF ANY): 4o REASONS FOR RESTRXCTXONS ( IF AEIY): THIS <<co> 2 CU1 it)LATIVE YR-TO DATE TO DATE ~ c'. novas RwcToa EJAS CRITICAL..;.....'....... REACTOR RESERVE SniJTDot?N HOURS... 0 04 3,841.49 0 0 6 057 3 7' O. 9. 10. 11. 12. 13 ' 14. 16. 17. 18. 8.578.08 8 259.696 ~2. 62 .8 0 2,483,584. 0 27.5 0 PLANTS IN TEST STATUS (PRXOR TO CO)'<<ERCXAL OPERATXON) REPORT THE FOLIONIiNG'ATE LAST DATE ~ REASON FOR FORECAST AcilIEVED DIFFERENCE INITIALCRITICALITY INITIALELECTRXCAL Poh'ER GENEPuKTXON co>2)ERCIAL OPEmrXON, ~ ~ II~ GROSS T)E'ER!VJ Po~ GENwATD (IftJH)...... 0 0 'ROSS ELECTRXCAL Po)63 GEN"MED (I'VH)('j) NET ELECTRICAL Po~ GElfEPATED (I!)JH)-.... REACTOR AVAILABILITYFACTOR(1) 25 6 UNXT USE FACTOR ( 2 ) ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ ~ e ~ o ~ ~ ~ ~ o UNIT CAPACITY FACTOR (3)................. 0
- 'II SHUTDO'h'NS SCIIEDULED To BEGIN XN NEXT 6 hoNTHS (STATE TYPE, DATE AI)D DUFJiTION OF EACEI):
XF SHUTDOWN'N AT END OF REPORT PERXPD, ESTDPATED DATE PF STARTUP Undeterminecl (1) REACTOR AV:ILABXLITYFACTOR - HOURS REACTOR tJAS
- CRXTXCAI, GROSS
)IOURS XN REPORTING PERIOD ~ 100 (2) Ufllx'SE FACTOR " ))OURS GENERATOR ON-LINE GROSS )!OURS IN !U?PORTING PERIOD +100 (3) UNXT CAPACITY FACTOR - NET ELECTPXCAL IOtJER GENEP?ATED CURIKNTLY LXC)NS 'D Pot'ER LEVEL"GROSS llOU)'S IN F?EI'OPTING PER10" ~ (4) FoRcED 0UTAGE I4Q'E - FoRC!'.D, oUTAG!'. 110'URs IIOURS G)'tNERATOPi ON-LINE + <<OPICED OUTAGE )10URS t (5) DOES NOT XNCLUD)'. AUXILIARYDIESEL GFNEFtTION +100
,~
v1.~KP.Y: Unit er:.ained in cold shutdown for. repair of control cables. REPORT YiOKZH March UNi'IT iiAME Brovns Ferrv 2 0/1/76 COzlPLE~D gY Harold 'pga lls k PM~NZ SHUTDOlPiiS-NO ~ 'I 75030l TYPE F-FORCED S-SCilEDULED DURATION HOURS REASON 1 METHOD OF SHUTTING DOLAN THE REACTOR 2 CO~i&KNTS (l) REASON: A-EQUIPi~Kai FAILURE {EX~LAIN) B-MAINT, OR TEST C-REFUELING D-RECULATORY RESTRICTION E "OPERATOR TRAINING AND LICENSIi'G EZ ~'IINATION F-ADMINISTRATIVE G-OPERATIONAL ERROR (EXPLAIN) (2) tETHOD: A-~LANUA B-i""KNUB CRA C": UTOi'CRD
UNIT 1&owns 1'erry 2 P4,TP 4 (1/76 COyg LETpD gY ~ Harold A. Halls Jl DAILY UHTT POtP;-'R OUTPUT nouni DAY 4 '7 10 12 13 15 '6 17 18 19 20 21 22 23 24 AVE1bhGH -5.8 -5.4 -5.4 -6.1 -5.3 -5.5 -5.7 -5.7 -'5. 6 -5. 2 -5.4 -5. 5 -5. 9 -5.9 -5.7 -5.6 -5.7 -5.7 -5.7 -5.7 -5.4 -6.6 -5.7 -5.7 Ht7e-net 25 26 27 28 29 30 31 AV""HAGH DAILY 1%7e-net -5.5 -5.5 -5.4 -6.0 -5.1 -6.0 Note: Negative values indicate station use +hen unit is oil line. ~ ~}}