Gary L. Stevens Technical Executive, EPRI NRC Public Meeting on Environmentally Assisted Fatigue (EAF) Research and Related ASME Activities September 25, 2018 NRC Headquarters - Rockville, MD Status of Previous EPRI EAF Efforts
2
© 2018 Electric Power Research Institute, Inc. All rights reserved.
EPRIs EAF Research Efforts Previous presentations at this meeting have provided updates of many of EPRIs EAF research projects
- Fatigue Usage Gradient and Life Factor Concept (Gosselin)
- Alternative Approaches for Simplified Elastic-Plastic Analysis (Raganath)
- Fatigue Limit of Stainless Steel for Use in Vibration Evaluation (Raganath)
- Corrosion Fatigue Crack Growth of Low Alloy Steel in BWRs (Raganath)
- Non-Isothermal EAF Testing for 316 Stainless Steel in Simulated PWR Environment (Asada)
- Hold Time and Water Chemistry Effects Testing (Smith)
- EAF Short Crack Growth Testing (Smith)
- EPRI EAF Component Testing (Smith)
This presentation provides the status of EPRIs remaining ongoing EAF research:
1.
Probabilistic Determination of Margins in ASME Code Section III CUF Calculations 2.
Fatigue Crack Growth Rates for Austenitic Stainless Steels in BWR Environments 3.
BWR Subsequent License Renewal EAF Database 4.
International Collaboration Group
3
© 2018 Electric Power Research Institute, Inc. All rights reserved.
This project develops a simplified engineering approach (based on probabilistic methods) that quantifies the uncertainties of inputs in CUF and CUFen calculations This approach may be used in CUF and CUFen sensitivity analyses to identify and rank those inputs and their uncertainties that control component CUF and CUFen and their uncertainties Detailed knowledge of the CUF and CUFen uncertainties in the underlying deterministic framework can help to:
Focus and direct efforts to eliminate unnecessary conservatism Reduce associated costs of (re)design, (re)analysis, inspections, and mitigation efforts to meet the unspecified margins associated with acceptance limits EPRI Report No. 3002012326, Basis and Method for Assessing Adequacy and Margins for Fatigue Under the Effects of Water Environment and Sources of Uncertainty May 2018 (publicly available at www.epri.com)
The technical report was provided to the ASME Code Section III Fatigue Steering Committee for their use to potentially refine Section III CUF calculation methods as a part of their Fatigue Action Plan Probabilistic Determination of CUF Margins
4
© 2018 Electric Power Research Institute, Inc. All rights reserved.
In the wake of the publication of ASME Code Section XI Appendix L (Flaw Tolerance) in 2008, a need arose for updated fatigue crack growth (FCG) rates in water environments for most Class 1 nuclear component materials ASME Code Case N-809, Reference Fatigue Crack Growth Rate Curves for Austenitic Stainless Steels in Pressurized Water Reactor Environments, was approved in 2015, and has been successfully used in at least two NRC-approved flaw tolerance submittals to-date Code Case N-809 has also been used applications supporting calculations for weld overlay repairs conducted using Code Cases N-504 and N-740-2 EPRI funded completion of the technical basis document and sample calculations for N-809 Additional efforts are needed to develop other FCG rate curves for other materials and other environments This project is developing FCG rates for austenitic stainless steels in BWR environments This project will revise Code Case N-809 to extend its application to BWR environments This project began earlier this year; data collection is in process Project outputs will be an ASME Code Section XI Code Case and a Technical Report Anticipated completion: 2019 BWR FCG Rates for Stainless Steels
5
© 2018 Electric Power Research Institute, Inc. All rights reserved.
As part of the revision to BWRVIP RPV Inspection and Evaluation Guidelines for life extension, EAF results were compiled for all BWRs that submitted 60-year LRAs and performed EAF evaluations The resulting database provides an overall snapshot of the work needed to address EAF for the BWR fleet for SLR Extensive database (over 500 components!)
Majority (76.7%) are acceptable for 80 years An additional 16.4% can use refined analysis to demonstrate acceptability (same as those used for 60 years)
Remaining 6.8% require other methods for acceptability Other methods that already exist or are under development will likely produce satisfactory results e.g., flaw tolerance, LF/GF approach, revised Ke Therefore, completion of ongoing analytical projects is important to address BWR fleet needs for SLR This project is complete and the results will be documented in an Appendix to BWRVIP-316, Reactor Pressure Vessel Inspection and Evaluation Guidelines for Long Term Operation (to be published in December 2018)
Last Updated: 10/05/2016 No. of Nuclear Sites:
22 No. of Nuclear Units:
33 A
B C
No. of Locations:
529 406 87 36 76.7%
16.4%
6.8%
No. of Locations per Suggested Approach
SUMMARY
OF RESULTS 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 0
100 200 300 400 500 Estimated CUF for 80 years Data Point No.
BWR SLR EAF Database Results (100% of Points Displayed = 529 component locations)
LEGEND A
The component passes for 80 years as-is using scaling without further analysis.
B The component does not pass for 80 years, but it can likely be reanalyzed successfully using more detailed evaluation methods.
C The component does not pass for 80 years, and it's already been reanalyzed; therefore, an alternative approach (stress-based fatigue (SBF), gradient factor approach, flaw tolerance or fatigue crack growth monitoring, or plastic analysis) is needed for SLR.
All Data Shown BWR EAF Database for 80 Years
6
© 2018 Electric Power Research Institute, Inc. All rights reserved.
EPRI hosts an EAF International Collaboration Group Original motivations for forming this group:
During an EPRI Conference in Summer of 2013 (San Francisco), several observations were identified on differences between European EAF work and the U.S. situation A subsequent meeting was held in January 2014 (France) between EDF, Rolls-Royce and AMEC to discuss exchanges on future test programs and ways of working together on alternative environmental fatigue and propagation methods The subsequent discussions recognized that there are mutual benefits to have a common approach e.g., data exchange, testing to fill gaps, avoiding duplication, analytical round robin studies, benchmarking of methods, mechanistic understanding, and joint lobbying of industry The purpose of this collaboration is to:
Periodically meet to exchange EAF information and data Coordinate research efforts to the extent practical Review on-going research and provide constructive input and direction Provide insight and ideas for new research projects (e.g., EPRIs EAF Component Test)
International Collaboration Group (1/2)
7
© 2018 Electric Power Research Institute, Inc. All rights reserved.
There are currently 7 participating organizations:
1.
EPRI 2.
Rolls-Royce 3.
Wood Group (formerly AMEC Foster Wheeler) 4.
Framatome 5.
Électricité de France SA (EDF) 6.
Bechtel Marine Propulsion Corporation - Naval Nuclear Laboratory (Bettis site) 7.
Mitsubishi Heavy Industries (MHI)
All 7 organizations have signed a Non-Disclosure Agreement (NDA) to facilitate exchange of information and data This group meets approximately once each year The last meeting was in December 14, 2017 (Paris, France)
The next meeting is September 26-27, 2018 (Washington, DC)
International Collaboration Group (2/2)
8
© 2018 Electric Power Research Institute, Inc. All rights reserved.