Post CoC Approval Criticality
ML18262A130
Person / Time
Site: 07109372
Issue date: 09/06/2018
From:
Framatome
To:
Office of Nuclear Material Safety and Safeguards
References
TJT:18:031
Download: ML18262A130 (1)


Text

Chapter 6 - Criticality Evaluation Question What document, consistent with the fuel composition, specifically address the impact of the transuranic constituents in the fuel on the criticality evaluation?

Response

See document Fuel Composition for general information regarding the fuel composition.

Table 1-3 Type B Quantity of Radioactive Material of the SAR provides a list of isotopes that could be present in the fuel material. Of these, the criticality analysis explicitly modeled U-235 and U-238. The only other isotope listed in Table 1-3 which may have an effect on the criticality analysis by increasing reactivity is Plutonium-239. Table 1-3 is reproduced below.

The trace quantity of plutonium present in the fuel matrix has a negligible effect on criticality. This is demonstrated for 8x8, 9x9, and 10x10 fuels in Section 6.6.2.1, Pu-239 Effect on Reactivity for the TN-B1 Package Array Hypothetical Accident Condition. This methodology is repeated in Section 6.12.6.1 for 11x11 fuel, where it is also concluded that The results indicate no statistically significant difference between the cases with and without plutonium. Therefore, plutonium is justifiably neglected in the TN-B1 evaluation.