7 2/9 Z28 49 254 I
~1
~ 273 ZSO 2/7 26/
N 688,000 I
Z78. /3 ZT5 i~qE CM11 N45H qA +
M3000
'8/
87 CM12 N4500 M2500 CN13 N4500 M2000 279 CM14 IV4500 W1500 269,-'I'62 rr
~J Z59 rr
~ 254 Z/
, ~
2/8
~2/7
~2/7
~ Z49 I
Z53 z5O
~259
~ Z62 CMlg N4500 T43 0
N 68/,000 PLANT SPUR DETOUR TRACK Z9Z Z87 288
~284
~ 27/
~ 286
~ 282
~Z78 zg57
~ 276 Z7) 27/
283 266 9
2 C
~2/7 0 /rii//
J//rrr//r~
r
~Ir r
/'r rir/
rirrrri rr r
Z67
~ Z/6
~ 25/
EEOC 258 Z87 286 Coocll)o TEEEICTIII. 2 TRENCH NO
~
6
,'N?
N35(!0
!M4000 N 686,OO Z50 Z75
. Z8/
CM5 42500 W40 N 685,000 25 N 684,000 I
CM6 N3000 W40QQ CM4 N2000 M4000 r
r Z69 CN3 f41500 M4000 NEST DIKE 5 6'
r o CCI ii, TRENCH NO.
5
/i C/
//
27/
276 DB-1-74 CooLIN6 T
\\
= FT-7-74.~
AND I VT-14 74 DB-3-74 FB-3-?4 s
9 FB-2-74 4
FB-8-?4
~268'rr Rr NEST DIKE 4 pl NEST DIKE 3S i+Coocloo To No.
4 r
r rr/rrr iirir 282 OOL I NG fON~440
~
1
~ 256
~Z53 FB-4-74 0
o 9'B674 26/
y
'CI
'C 2536 ot 0',
cl' lll ol
/
2 000 o
Eci lak 0
i OCI eo c
I
~Z49 r
'oI
~I r~
r c5 T
H NO.'$
r z50 r
r/i r ~ FT-11-74 AND FT-12-74 o 74 Ie r
277 TRENCH, NO.
2 r
r<
r r
z63 r
FT874X
~~
4 3
4 <<r FT-2-74 FT-1-74 s
PLANT ISLAND OUTLINE DB
( ~
lr FT-9-74
\\
rr I
~
FT-13-74 EE a
a~ a ~ a~,~
~.
0 73 FB-5-74
~
p2 2
I--
I.I /'i 2r
~ Z58
)5 I
I EAST DIKE 2 I
) r Fz FT-3-74 FT-10-74 FAULT 69 FT-6-74 I4 FB-1-?4 Z68
'Ill, TRENCH NO. l~~g 25O A~
TRENCH NO.
8
- Z44, 0
0 Eci EEI Z/4 CLEARING LINIT
~Z/3
~ 2/Z 2/2
~ 2/Z rrr pi l rr EAST DIKE 1 r
ZO9 ZO7 0
0 Ol THE BASE NAP IS TAKEN FROM TOPQGRAPHIC MAPS PREPARED BY PHOTO SCIENCE INC.
UTILIZING STEREOPHOTOGRAMNETRIC NETHODS FROM PHOTOGRAPHY DATED FEB.
7, 1970 AND
- FEB, 5,
- 1972, HORIZONTAL CONTROL IS TAKEN FRON NORTH CAROLINA STATE PLANE COORDINATE SYSTEN VERTICAL CONTROL IS TAKEN FROM U.S.C, AND G,S, DATUN.
EXPLANATION U
- FAULT, SHOWING DIP D
U, UPTHROWN SIDE; D,
DOWNTHROWN SIDE DIABASE DIKE, SHOWING DIP NUNBER INDICATES THICKNESS IN FEET lllt+44llllilllll
~20 STRIKE AND DIP OF BkDS FT-2-74A
~ ~~ ~ ~ ~ IkR EXPLORATION TRENCH-DUG 1974 5
TO 40 FT.
DEPTH EXPLORATION TRENCH-DUG 1cj70 2
TO 15 FT.
DEPTH EXPLORATION BORING-DRI! LED 1974 TRCNCII I40. 9+
H Z
'iiI 262
'g ll ll I
8/// NN-3 FL. Z6Z.959 258 I
TRENCH NO.
3 I
N2 1000 W4000 CN1 N500 9400()
26/
WEST DIKE 3 CLEARING LINIT 250 249 h
256 Z25 246 I
9 ZO7. 05 2069 0
200 400 SCALE IN FEET CAROLINA POWER 8, LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT EBASCO SERVICES INCORPORATED PLAN VIEW SITE FAULT INVESTIGATION PLATE.2
~