Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contractors

?o - 3 c:; 0 /

TWRS RL/RU :96-0014 Richland Operations Office, MS A4-70, PO Box 550, Richland, WA 99352 Phone (509) 376-6012 Fax (509) 376-3661 October 29, 1996 Mr. Maurice Bullock BNFL Reg Unit Dr. James A. Tegnelia Lockheed-Martin Advanced Environmental Systems 201 3rd Street N.W., Suite 1600 Albuquerque, New Mexico 87102 1835 Terminal Drive, Suite 220 Richland, Washington 99352 Gentlemen:

Subject:

"Guidance for Review of TWRS Privatization Contractor Initial Quality Assurance Program, October 1996, RL/REG-96-01, Revision 0, and Guidance for Review of TWRS Privatizaion Contractor Employee Concerns Management System, October 1996, RL/REG-96-03."

Reference:

My letter, 96-WDD-147, dated September 26, 1996, "General Background Information, Guidance and Requirements Related to Radiological, Nuclear, and Process Safety Regulation".

Enclosed is guidance to my staff, which was prepared to assist in their review of your Initial Quality Assurance and Employee Concerns Programs; they are being provided for your information. These are final versions and replace the draft documents provided to you as Enclosures 13 and 14 of my referenced letter.

These documents do not constitute changes in the provisions of your contract.

This letter and the enclosures will be placed in the Public Document Reading Room in Richland.

Sincerely,

~-~rid Regulatory Office

Enclosures:

"Guidance for Review of TWRS Privatization Contractor Copied:

P. Rasmussen RU File Initial Quality Assurance Program, RL/REG-96-01, Rev. O" "Guidance for Review of TWRS Privatization Contractor Employee Concerns Management System, RL/REG-96-03, Rev. O" 9611130035 961029 PDR ADOCK 07003091 C

PDR I. I I

-'".1. -~ :..:.~.---'.

Guidance for Review of TWRS Privatization Contractor Employee Concerns Management System October 1996 Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contractors 9611130083 961029 tDR ADOCK 07003091 PDR Richland Operations Office POBox550 Richland, WA 99352 RL/REG-96-03 Revision 0

Attribute Guidance Employee Concerns Table of Contents

1.0 INTRODUCTION

...................................................................................... 1

2.0 BACKGROUND

....................................................................................... 1 2.1 Whistleblower Protection................................................................................................... I 2.2 Regulatory Enforcement and Oversight................................................................................. I 2.3 Privatization Approach............................................................. :........................................ I

3. 0 PURPOSE.............................................................................................. 2 4.0 STRUCTURE.......................................................................................... 2
5. 0 EMPLOYEE CONCERNS PROGRAM REQUIREMENT....................................... 2
5. I Requirement: Employee Concerns Management System.......................................................... 2 5.2 Intent............................................................................................................................. 2 5.3 Attributes....................................................................................................................... 2 6.0 ATTRIBUTES FOR KEY PROGRAM ELEMENTS............................................. 2 6.1 Key Element I - Commitment to DOE Policy on Employee Concerns....................................... 3 6.2 Key Element 2 - Designation of Employee Concerns Manager..................................................4 6.3 Key Element 3 - Notification of Employees and Establishing a Hotline......................................4 6.4 Key Element 4 - Operation of an Employee Concerns Management System.................................5 6.5 Key Element 5 - Identification of Significant Issues............................................................... 6
7. 0 GENERAL SUB MITT AL EXPECT A TIO NS...................................................... 7
7. I Existing ECP.................................................................................................................. 7 7.2 Other Approaches............................................................................................................. 7 RUREG-96-03 Rev. 0, 10-29-96 i&

Attribute Guidance Employee Concerns (This page intentionally left blank.)

ii Rev. 0, 10-29-96 RUREG-96-03

1. 0 INTRODUCTION The Department of Energy (DOE) promotes a culture of operation in which expression and timely resolu-tion of employee Environment, Safety, & Health (ES&H) concerns occurs. Situations in which safety and health issues go unaddressed with the possible result of avoidable risks to workers, the public 800 the environment must be avoided. This expectation is reflected in the document Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Privatization Contractors, DOFJRL 0006 for the Tank Waste Remediation System (TWRS) Privatization Program. 'The principal objec-tive of the Employee Concerns Program (ECP), re-quired by the TWRS Privatization Contract, is to promote prompt identification and resolution of em-ployee concerns without the need for sanctions to the Contractor or the employee. The alternative to an effective concerns management program can be legal proceedings or regulatory action.

2.0 BACKGROUND

2.1 Whistleblower Protection Federal Law prohibits discrimination against those employees who raise safety concerns..

Prohibited action by its contractors is acted upon by the DOE in several ways. This includes legal protection of em-ployee rights, including directed restoration of em-ployee privileges and benefits if denied by prohibited Contractor activity. For most regulated activities, the Department of Labor (DOL) is the agency which in-vestigates these situations.

Previous action under these laws represents a body of legal and administra-tive experience that establishes an accepted practice of protected activities.

In the Energy Policy Act of 1992, a new section on worker protection -- 2 I I to the Energy Reorganiza-tion Act of 1974 -- provides additional clarity on the description of covered employees and protected activi-ties. DOE contractors, provided nuclear hazards in-demnification under Part I 70d of the Atomic Energy Act, are explicitly included. The TWRS Privatization Contracts include such indemnification.

Remedy for reprisal against protected employee ac-tions occurring in Contractor-owned facilities is available under 29 CFR 24, administered by the DOL. The potentialexists for Privatization Contrac-tor actions to fall under IO CFR 708, a similar regu-lation administered by the DOE if Government-owned nuclear facilities or equipment are involved. The ex-pectation of DOE is that employees will usually seek redress by means of the DOL rules. Communi-cation of DOE's expectations is addressed in the at-RUREG-96-03 Attribute Guidance Employee Concerns tributes section of this guidance document.

This document will help DOE reviewers to determine the adequacy and responsiveness of a Contractor's ECP.

The Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contrac-tors, referred to herein as the Regulatory Unit (RU),

does not investigate Whistleblower complaints for purposes of employee protection under the law.

Complaints of prohibited Contractor activity will be referred to the DOL. However, the RU will act to ensure that potentially unsafe conditions are promptly investigated and remediated, if necessary, to restore adequate protection of workers, the public, and the environment.

2. 2 Regulatory Enforcement and Over-sight In addition, the DOE (10 CFR 820) and the NRC (10 CFR 2 and 19) each provide for additional sanctions under their enforcement of nuclear safety rules 800 regulations if such employee discrimination is deter-mined to result in a substantive diminishment of compliance, with nuclear safety requirements. NRC enforcement policy provides that the severity level assigned a violation for reprisal may be graded upward as the level of management involvement in the pro-hibited activity rises.. This indicates the importance the NRC places upon maintaining an open environ-ment for the expression of concerns within its licen-sees' organizations. The DOE is committed to a regulatory process consistent with NRC's principles and concepts.

As a matter of practice, both NRC and DOE encour-age self-identification and resolution of safety con-cerns between employee and employer. Evidence of openness in the treatment of concerns about regulated activities is generally accepted as consistent with high levels of integrated safety management. In tum, this openness can result in reduced reliance upon enforce-ment action by the regulators to ensure adequate pro-vision of safe facility operation. DOE policy regard-ing its commitment to effective treatment of em-ployee concerns is found in DOE Order 5480.29. The DOE's approach to management of ES&H concerns encourages reporting and provides protection for em-ployees who may fear reprisal for their actions or who have been unable to obtain satisfactory resolu-tion of their concern directly from their employer.

2. 3 Privatization Approach The DOE Manager, Richland Operations Office (RL),has expressed by means of the Environment, Safety and Health Standard of the TWRS Privatiza-tion Contracts, a formal requirement that Contractors Rev. 0, 10-29-96 Page 1 of 7 I

Attribute Guidance Employee Concerns develop their own ECP. DOE Order 5480.29 is refer-enced for development of this deliverable. The guid-ance document herein provides DOE reviewers with the key elements and expectations of an effective aoo acceptable ECP.

In the discharge of its responsibilities under DOE Order 5480.29, RL has instituted an Employee Con-cerns Management System that applies to its entire area of responsibility. The RU Employee Concerns Manager (ECM), designated for this program, will coordinate and oversee the activities of all Contractor-maintained ECPs.

Routine reporting, identified by the Order, will* be through this individual.

This document establishes minimum expectations for*the exchange of information between the Contractor's ECP Manager and the RU ECM. It is expected that Contractor employees will be appraised of the oppor-tunity they have to raise concerns with the RU ECM as described in the attributes identified herein.

For the TWRS Privatization Contractor, the RU is the focal point for implementation of the ECP proc-ess. It is the expectation of the Director of the RU, the Regulatory Official (RO), that once the program is approved, it will be maintained under the RU docket for the Contract. Implementation of the ECP will receive routine oversight by the RU ECM. The RU will disposition concerns related to nuclear, radio-logical, and process safety and health. Environmental concerns will normally be communicated by RU to the lead regulator for environmental protection.

3.0 PURPOSE This document sets forth the general basis that the RU will use to review the Contractor's ECP. It will be used by the RU to determine the adequacy and ba-sis for approval by the RO of the Contractor's ECP.

4.0 STRUCTURE This guidance document describes the requirements, key program elements, and attributes of an acceptable TWRS Privatization Contractor ECP that is consis-tent with the foregoing principles. RU reviewers of the Contractor's proposed ECP will confirm that the anticipated elements are present in the program. The information described herein suggests the acceptable characteristics and typical means to be employed to satisfy DOE expectations. Other means and methods may be suggested and will be evaluated by the RU.

Approval of the Contractor's ECP by the RO will reflect confirmation that requirements are satisfied.

Section 5 of this document presents requirements invoked by the TWRS Privatization Contract, which forms the basis for the RU perspective. In Section 6, the key elements of an acceptable ECP are described.

Specific sources are identified to assist in understand-ing the reason for including that element. Attributes that further describe successful components of the key elements are also described in this section. Section 7 highlights general information that may further fa-cilitate review of the Contractor's ECP.

5. 0 EMPLOYEE CONCERNS PRO-GRAM REQUIREMENT 5.1 Requirement:

Employee Concerns Management System The following singular requirement exists: the Con-tractor shall prepare and submit to the DOE RU for review and approval a description of an Employee Concerns Management System (Table S4-l, Radio-logical, Nuclear, and Process Safety Deliverables for Part A and Part B).

5.2 Intent The required deliverable communicates the importance,

DOE places upon the Contractor's establishing of an atmosphere of performance which encourages identifi-cation and disposition of employee concerns within its own management structures to the maximum ex-tent practicable. This expectation applies to the standards identification activities and continues through each subsequent regulatory action covered by the Contract.

5.3 Attributes Submittal of a Contractor-developed plan that de-scribes an ECP acceptable to the RO completes this requirement. Attributes of an acceptable submittal are expected to reflect those common to previously ac-cepted programs as described in the next section of this guidance document. No individual attribute is mandatory, but a submittal containing most of the key elements expressed in Section 6 should provide the reviewer with a persuasive basis for concluding that the Contractor is on record as encouraging the report of ES&H concerns and has provided for the timely, documented disposition of such concerns.

6.0 ATTRIBUTES FOR KEY PRO-GRAM ELEMENTS The following key program elements have been iden-tified based upon the characteristics found in accept-able, existing DOE Employee Concerns Management policy and practice.

Page 2 of7 Rev. 0, 10-29-96 RUREG-96-03 I..

iil

6. 1 Key Element 1 -

Commitment to DOE Policy on Employee Concerns 6.1.1 Description The Department, by means of regulations and orders, has established a fundamental policy that encourages prompt reporting of ES&H concerns as well as the prompt resolution of defective conditions identified by those reports. Resolution of concerns at the lowest management level practicable is encouraged. Applica-ble regulations expressly prohibit reprisals against employees who legitimately exercise their right to report concerns. An acceptable ECP should commit to adoption of the DOE policy as its basis.

6.1.2 Source I) DOE Order 5480.29, Employee Concerns Man-agement System, Section 5, Policy

2) Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Priva-tization Contractors, DOEJRL-96-0006, Princi-ple 4.1.4, Safety/Quality Culture
3) Richland Implementing Directive (RLID),

5480.29 RL Employee Concerns Program, (December 12, 1994), Section 5.2 6.1.3 Justification This element promotes regulatory stability and reli-ability by demonstrating a shared DOE and Contractor commitment to a Safety/Quality Culture,, by means of attention to the timely identification of potential safety concerns. DOE policy and practice are well-established and are considered to provide an effective overall means of TWRS Privatization Contract im-plementation.

Note:

The RU ECP Manager per-forms the duties of the RL ECP Manager for TWRS Privatization Contracts.

6.1.4 Attributes 6.1.4.1 Attribute I - Communicate corporate com-mitment to management of employee ES&H concerns as an element of its safety program.

Description -

To be consistent with the DOE-stipulated top-level safety principles, strong declara-tion of corporate intentions regarding the potentially sensitive matter of employee concerns is needed.

Such a declaration can ensure that the opportunity to communicate safety concerns is taken seriously by management and is accepted and used by employees at every level in the organization. This declaration should be made at a sufficiently high level of author-RUREG-96-03 Attribute Guidance Employee Concerns ity and from a position that indicates line manage-ment acceptance for the safe operation of the facility.

The term "employee concern" should be defined (e.g.,

RLID 5480.29, 5.2).

Submittal expectation - The Contractor's ECP sub-mittal should make clear to any reader that formal commitments have been made by Contractor man-agement to adopt or exceed the provisions of DOE policy for the management of safety concerns.

6.1.4.2 Attribute 2 - Prohibit reprisals Description - It is the policy of DOE that employees of contractors to DOE should be able to provide in-formation without fear of reprisal. Reprisal is said to occur when prohibited acts (29 CFR 24.2) are taken against a protected individual. An act of reprisal can be taken without the knowledge of contractor execu-tive management and still result in liability to the organization. (Note: when nuclear safety requirements are involved, 10 CFR 820 may be invoked).. A goal of an effective ECP should be to preclude the tempta-tion to* resort to reprisal as a means of dealing with employee concerns.

Submittal expectation - The Contractor's ECP sub-mittal should state, for the benefit of management and employees, that reprisal undertaken at any level of management authority is unacceptable practice., The conditions that constitute reprisal should be mooe known to employees and managers throughout the organization.

6.1.4.3 Attribute 3 - Responsiveness Description - Employee concern reports should be managed in a manner that assures prompt identifica-tion, prioritization, evaluation, corrective and protec-tive response to safety deficiencies, and resolution of concerns raised by Contractor or subcontractor em-ployees.

Submittal expectation - The Contractor's ECP sub-mittal should provide mechanisms for responsive treatment of concerns consistent with the DOE pro-gram standards found in DOE Order 5480.29, Section

9.

6.1.4.4 Attribute 4 - Communicate DOE support for employee use of the Contractor ECP.

Description - Consistent with the DOE-stipulated top-level safety principles, an atmosphere of open communication should exist within the Contractor's organization that encourages the expression of ES&H concerns and promotes their resolution at the lowest level practicable.

However, conditions can arise Rev. 0, 10-29-96 Page 3 of 7 L

ii

Attribute Guidance Employee Concerns where employees believe that recourse to their em-ployer is not effective. Employees should be advised that they are not obligated to express their concern prior to notification of the RU or other authorized Government agency that could receive employee con-cerns.

Submittal expectation - The Contractor's ECP sub-mittal should encourage employees to bring concerns to the attention of Contractor management by the most effective means available. Policy should also indicate that use by an employee of the RU or other appropriate agency employee concerns program is permitted. An *acceptable structure of the resolution process is fourid in RLID 5480.29 Attachment l, b.

(5).

6.2 Key Element 2 - Designation of Em-ployee Concerns Manager 6.2.1 Description The designation of an individual with appropriate management authority is needed to ensure that the ECP incorporates attributes of objectivity, confidenti-ality, and privacy in established mechanisms for the implementation and maintenance of the program. An acceptable program should incorporate provisions for designating an ECP Manager.

6.2.2 Source

1) DOE Order 5480.29, Employee Concerns Man-agement System, Section 9.b
2) RLID 5480.29, RL Employee Concerns Pro-gram, (December 12, 1994), Section 6.2 & At-tachment 1 6.2.3 Justification This element ensures compatibility between the prin-cipal RU mechanism responsible for program imple-mentation and maintenance and that established in the Contractor's ECP.

An acceptable program should provide for reasonable alignment of Contractor aoo RU functions, so that the status of outstanding con-cerns is made available to the RO.

6.2.4 Attributes 6.2.4.1 Attribute I - Fomially designate one or more individuals to be responsible for management of the implementation and maintenance of the ECP.

Description - The treatment of employee e:oncems requires awareness of a number of special considera-tions that need to be kept in mind during disposition of the concern. The individuals responsible for man-aging the ECP should be formally designated by management and possess a thorough knowledge of their duties. Designees should be made known to the RUECM Submittal expectation - The Contractor's ECP sub-mittal should provide for the formal designation of its Employee Concerns Program Manager(s). The pro-gram should provide for periodic submission to the RU ECM of a complete list of its Program Manag-ers, including their names, titles, and telephone num-bers. This notification supports coordination of re-porting information.

6.3 Key Element 3

  • Notification of Employees
  • and Establishing a Hot-line 6.3.1 Description The effectiveness of any ECP depends upon the

.awareness of employees that their concerns are wel-come and upon the provision of a simple and confi-dential means of reporting concerns.

Notification ensures Contractor employees are aware that recourse to the RU ECP is available and communicates the option of seeking remedy if they believe discrimina-tion has occurred as a result of engaging in protected activity. The use of a telephone hotline permits noti-fication of concerns upon short notice and during any shift of work.

This element incorporates standard features of established DOE ECPs.

6.3.2* ~

1)

DOE Order 5480.29, Employee Concerns Management System, Section 9.b

2) RLID 5480.29, RL Employee Concerns Pro-gram, (December 12, 1994), Section 6.2 & At-tachment I 6.3.3 Justification RL has well-established mechanisms for the commu-nication of rights and responsibilities to those wish-ing to make use of employee concerns programs. An acceptable program should reflect mechanisms similar to those presently in use.

A Contractor's existing program, previously accepted by DOE, would be evi-dence of meeting this element.

Page 4 of 7 Rev. 0, 10-29-96 RUREG-96-03 1"

ill

6.3.4 Attributes 6.3.4.1 Attribute I - Provide effective communication methods for assuring that employees are aware of the ECP and how to use it.

Description - The Contractor should take action to ensure that the provisions of its ECP are communi-cated to all employees. Program guidance should pro-vide for an information poster with instructions for its prominent display in the work place. The poster should address the employees' right to recourse di-rectly to the DOL from prohibited acts under 29 CFR

24. In some instances, recourse is to DOE under 10 CFR 708." The RU ECM can assist employees who believe a formal complaint is warranted.

Submittal expectation - The Contractor's ECP sub-mittal should describe an information poster which will be used to inform employees of the Contractor's policy on concerns management and of the options for initiating a concern. Information regarding report-ing of prohibited acts should be included.

6.3.4.2 Attribute 2 - Establish a 24-hour telephone capability for easy access and timely report-ing.

Description - Establishing a hotline for the receipt of initial notifications of concerns is a standard feature of DOE ECPs. (DOE Order 5480.29, Section 9.a.(6),

9.b.(9)(a)) It is acceptable to use a recording device for the initial report if it is secured in a controlled area such as a locked office or a locked cabinet in a limited access area.

Submittal expectation - The Contractor's ECP sub-mittal should describe the provisions for establishing a secure (i.e., confidential) hotline consistent with the referenced standard.

6, 4 Key Element 4

  • Operation of an Employee Concerns Management System 6.4.1 Description An acceptable ECP should include procedures re-signed to provide prompt identification, prioritization, evaluation, and corrective and protective response aoo resolution of employee concerns. Provisions for pro-tection of privacy and confidentiality are needed. This element incorporates standard features of established DOE ECPs.

RUREG-96-03 Attribute Guidance Employee Concerns 6.4.2 Source I)

  • DOE Order 5480.29, Employee Concerns Man-agement System, Sections 9.a, & b.
2) RLID 5480.29, RL Employee Concerns Pro-gram, (Decembei;. 12, 1994), Section 6.2 & At-tachment 1.

6.4.3 Justification RL has well-established administrative controls con-sistent with DOE policy, appropriate to an employee concerns program. An acceptable program should reflect mechanisms similar to those presently in use.

A Contractor's existing, previously accepted program would be evidence of meeting this element.

6.4.4 Attributes 6.4.4.1 Attribute 1 - Establish prompt contact with the employee to confirm understanding of the concern.

Description - Concerns may be registered. in either written or verbal form.

Experience suggests that prompt follow-up with the employee making the report can ensure that resolution efforts are properly focused and directed. DOE encourages the resolution of concerns by established Contractor corrective oc-tion systems. Records of concern should identify if use of normal systems for deficiency reporting have been attempted or if reasons exist for dissatisfaction with reporting by those means.

Submittal expectation - The Contractor's ECP sub-mittal should provide for employee acknowledgment regarding intent of the concern, priority determina-tion, and an established schedule for resolution of within 5 working days of the receipt of the concern.

(DOE Order 5480.29, 9.f (1))

6.4.4.2 Attribute 2 - Establish and maintain a report tracking system.

Description - A formal system is needed to ensure that traceable records exist of actions taken to resolve the concern.

Submittal ex;pectation - The Contractor's ECP sub-mittal should describe the information to be main-tained by its Employee Concerns Manager that pro-vides unique traceability of the disposition of each concern received. The priority assigned, the individ-ual assigned to investigate, and evidence of completed actions within the required time frames should be some of the information included. Other information which may support the generation of periodic reports Rev. 0, 10-29-96 Page 5 of 7 r-

Attribute Guidance Employee Concerns or analysis of trends may, but need not, be included in the tracking system. (RUD 5480.29, Attachment l.b.(7))

6.4.4.3 Attribute 3 - Establish standards for adequate investigation of concerns.

Description - The thorough investigation of concerns is essential to meeting the objectives of the ECP.

The criteria established for the conduct of concern resolution can be indicative of management's com-mitment to the program.

Submittal expectation - The Contractor's ECP sub-mittal should describe the criteria that assigned inves-tigators use in the evaluation of the concern. Evaluat-ing and determining the significance of employee concerns requires professional judgment and should generally be performed by a senior line manager or ES&H staff member. Acceptable criteria to be con-sidered as standards are found in DOE Order 5480.29, Chapter 1, 6.a.

6.4.4.4 Attribute 4 - Establish provisions for main-taining privacy and confidentiality of infor-mation and sources.

Description - It is customary, as part of encouraging employees to be forthcoming about safety concerns, to offer the opportunity for confidential treatment of their concern and identity. Mechanisms should be established so that, if confidentiality is requested, information used to permit concern resolution will not result in disclosure of privileged information or the identity of the person providing the information.

Submittal expectation - The Contractor's ECP sub-mittal should describe provisions for the confidential treatment of employee information and identity. Re-cords of employee decisions (i.e., choices) concerning their identification during the resolution process should be prepared.

  • Appropriate training for those responsible for ECP management regarding such pro-visions should be provided. Maintenance of a secure storage system that contains all materials developed for the evaluation of the employee concern from iden-tification through resolution to closure should be provided. (DOE Order 5480.29, 9.a. (4) & (8))

6.4.4.5 Attribute 5 - Establish standard response times for disposition of concerns.

Description - Prompt acknowledgment, prioritization, investigation and disposition of the concern are in the best interest of the employee, the Contractor, and the DOE. A routine time cycle for completion of stan-dard actions leading to closure is contained in DOE programs as described in RUD 5480.29. Alignment of Contractor ECP response cycles to those used by the RU is desirable. Provisions for acceptable devia-tions, if formalized, are acceptable.

Submittal expectation - The Contractor's ECP sub-mittal should describe the expected timeline for proc-essing of concerns. All evaluations should normally be completed within 30 working days. Exceptions to the 30-day evaluation for any concern should be for-mally documented with intended completion dates identified and reviewed by a designated senior manager to indicate concurrence with this exception.

6.4.4.6 Attribute 6 - Develop and submit periodic reports of the status of concerns to manage-ment.

Description - The significance of employee concerns to the effectiveness of the Contractor's safety man-agement plan warrants the periodic notification to senior management of the status of outstanding con-cerns.

Submittal expectation - The Contractor's ECP sub-mittal should address periodic reporting of the status of concerns to its senior management. An informa-tion copy of each periodic status report should be provided to the RU ECM. Typical report contents are described in RUD 5480.29, Act. 1, b(7).

6. 5 Key Element 5 -

Identification of Significant Issues 6.5.1 Description The primary objective of the ECP is to assure em-ployees that their concerns about safety will be re-spected and addressed. The significance of a reported concern should be promptly established. Issues may exist which are indicative of potentially substantial breakdowns in the functioning of a Contractor's in-tegrated safety management system.

These break-downs could be in the form of imminent hazards not

. recogniz:ed by the reporting employee as evidence of non-compliance with regulatory requirements. This element reflects standard features of established DOE ECPs.

6.5.2 ~

1) DOE Order 5480.29, Employee Concerns Man-agement System, Section 9.d & Chapter I.
2) RUD 5480.29, RL Employee Concerns Pro-gram, (December 12, 1994),, Section 5.2 Page 6 of7 Rev. 0, 10-29-96 RUREG-96-03

6.5.3 Justification Concerns presented by employees may not reflect a full understanding of the safety significance of the situation surrounding an issue. Responsible manag-ers are expected to remain cognizant of the overall status of conformance with agreed-upon commitments and accepted standards. Criteria are needed to ensure that information that may impact that status is prop-erly evaluated if raised within the ECP. An accept-able program should reflect, as a minimum, the screening customarily used in established DOE pro-grams.

6.5.4 Attributes 6.5.4.1 Attribute I - Establish criteria for evaluation of the significance and priority of the concern resolution.

Description - One objective of the ECP is to ensure that legitimate safety concerns that have not been identified by any other means are captured for appro-priate action. In addition, the employee making a report may not fully appreciate the significance of the conditions that prompted his concern.

  • Submittal expectation - The Contractor's ECP sub-mittal should establish criteria for evaluating the sig-nificance of reported concerns. Criteria should iden-tify the priority of response and the conditions under which the concern will be examined by other parties.

Acceptable criteria for evaluating significance are found in DOE Order 5480.29, 9.d.

6.5.4.2 Attribute 2 - Establish criteria for referral of concerns to affected DOE groups or other agencies.

Description - This attribute provides for a prompt evaluation of the potential urgency of action and en-sures the appropriate involvement of other responsi-ble parties.

Submittal expectation - The Contractor's ECP sub-mittal should establish categories of concerns that warrant notification to other responsible parties.

Other parties should include responsible regulatory agencies if conditions exist that are reportable by regulation or agreement to those agencies. It should be made clear that such reporting is the responsibility of the Contractor and not the employee. Representa-tive categories for involvement of other responsible parties are given in DOE Order 5480.29, 8 f. (8).

These categories are suggestions only and may be tailored by the Contractor. However, disposition of potential violation of rules subject to the enforcement authority of the Price-Anderson Amendments Act of Attribute Guidance Employee Concerns 1988 (PAA) should be in accordance with the regula-tions implementing the PAA.

6.5.4.3 Attribute 3 - Monitor program results for trends of performance against program goals.

Description - Overall experience with use of the ECP

  • can provide insight into the Contractor's effectiveness in meeting the goals of its integrated safety manage-ment program. Periodic evaluation of the program's record is appropriate when it has been significantly used Submittal expectation -

The Contractor's ECP sub-mittal should establish provisions for a quarterly re-port of all employee concerns initiated, closed, or remaining unresolved during the past quarter. This report should be submitted to the Contractor's senior management with an information copy to the RU ECM.

An acceptable format would be consistent with the criteria established in RLID 5480.29, At-tachment l.b.(7).

7. 0 GENERAL SUBMITTAL EXPEC-TATIONS
7. 1 Existing ECP The Contractor may submit for consideration an ex-isting ECP that has been previously approved by DOE. The review of the submittal will be conducted against the guidance in this document to determine adequacy.
7. 2 Other Approaches The Contractor is encouraged to adopt the guidance provided in this document.

However, other ap-proaches to definition and management of an ECP may be acceptable. This guidance for reviewers has been provided in order that external stakeholders may understand the basis from which a determination of adequacy was established. A Contractor's substan-tially alternative approach should provide appropriate definition of its basis for adequacy. Lack of clarity in this regard may be grounds for a finding that the submittal is inadequate.

RUREG-96-03 Rev. 0, 10-29-96 Page 7 of7

Guidance for Review of TWRS Privatization Contractor Initial Quality Assurance Program October 1996 Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contractors 9611130089 961029 PDR ADOCK 07003091 C

PDR Richland Operations Office POBox550 Richland, WA 99352

/. I ** - )! '<; i I

Rl.JREG-96-01 Revision 0 r

-~

PREFACE The Depanment of Energy's (DOE) Richland Operations Office (RL) issued the 1WRS Privatiwtion Request for Proposal (RFP) for Hanford Tanlc Waste Remediation System (TWRS) Privatiza-tion in February 1996. Offcrors were requested to submit pro-posals for the initial processing of the tanlc waste at Hanford.

Some of this radioactive waste has been stored in large under-ground storage tanlcs at the Hanford Site since 1944. Currently, approximately 56 million gallons of waste containing approxi-mately 240,000 metric tons of processed chemicals and 250 mega-curies of radionuclides are being stored in 177 tanks.

These caustic wastes are in the form of liquids, slurries, saltcakes, and sludges. The wastes stored in the tanlcs are defined as high-level radioactive waste (10 a=R Part SO, Appen4ix F) and haz-ardous waste (Resource Conservation and Recovery Act).

Under the privatization concept, DOE will purchase waste treat-ment services from a contractor-owned, contractor-operated fa-cility under a fixed-price contract. DOE will provide the waste feedstock to be processed but maintain ownership of the waste.

The contractor must: a) provide private financing; b) design the equipment and facility; c) apply for and receive required permits and licenses; d) construct the facility and bring it on-line; e) oper-ate the facility to treat the waste according to DOE specifications; and f) deactivate the facility.

The TWRS Privatization Program is divided into two phases, Phase I and Phase II. Phase I is a proof-of-concept/commercial demonstration-scale effort the objectives of which arc to a) dem-onstrate the teclmical and business viability of using privatized contractors to treat Hanford tanlc waste; b) define and maintain adequate levels of radiological, nuclear, process, and occupa-tional safety; c) maintain environmental protection and compli-ance; and d) substantially reduce life-cycle costs and time re-quired to treat the tanlc waste. The Phase I effort consists of two parts: Part A and Part B.

Part A consists of a twenty-month development period to establish appropriate and necessary technical, operational, regulatory, business, and financial clements. This will include identification by the TWRS Privatization Contractors and approval by DOE of appropriate safety standards, formulation by the Contractors and approval by DOE of integrated safety management plans, and preparation by the Contractors and evaluation by DOE of initial safety assessments. Of the twenty-month period, sixteen months will be used by the Contractors to develop the Part-A products and four months will be used by DOE to evaluate the products.

Part B consists of a demonstration period to provide tanlc waste treatment services by one or more of the TWRS Privatization Contractors who successfully complete Part A. Demonstration will address a range of wastes representative of those in the Han-ford tanks. Part B will be 10 to 14 years in duration. Within Part B, wastes will be processed during a 5-to 9-year period and will result in treatment of 6 to 13 percent of the Hanford tanlc waste.

Phase II will be a full-scale production phase in which the re-maining tanic waste will be processed on a schedule that will ac-complish removal from all single-shelled tanlcs by the year 2018.

The objectives of Phase Il arc to a) implement the lessons learned from Phase I; and b) process all tanlc waste into forms suitable for final disposal.

A key clement of the TWRS Privatization Contracts is DOE regulation of radiological. nuclear. and process safety through the establishment of a specifically chartered. dedicated Regulatory Unit (RU) at RL. This regulation by the RU is authorized by the document entitled Policy for Radiological, Nuclear, and Process Safery Regulation of 1WRS PrivatiZJJJion Contractors (referred to as the Policy) and implemented through the document entitled Memorandum of Agreement for the E:cecution of Radiological, Nuclear, and Process Safery Regulation of the TWRS PrivatiztJtion Contractors (referred to as the MOA). The Policy is signed by the Under Secretary of Energy; the Manager. RL; the Assistant Secretary for Environment, Safety and Health (ASEH); and the Assistant Secretary for Environmental Management (ASEM).

The MOA is signed by the Manager, RL; the ASEH; and the ASEM. The nature and characteristics of this regulation are also specified in these documents. The MOA details certain interac-tions among RL, the ASEH, and the ASEM as well as their re-spective roles and responsibilities for implementation of this regulation.

The authority of the RU to regulate the TWRS Privatization Con-tractors is derived solely from the terms of the TWRS Privatiza-tion Contracts. Its authority to regulate the Contractors on behalf of DOE is derived from the Policy. The nature and scope of this

~

regulation (in the sense that it is based on terms of a con-tract rather than formal regulations) is delineated in the MOA, the TWRS Privatization Contracts, and the four documents (listed below), which are incorporated into the Contracts. This ~

regulation by the RU in no way replaces any legally established external regulatory authority to regulate in accordance with their duly promulgated regulations nor relieves the Contractors from any obligations to comply with such regulations or to be subject to the enforcement practices contained therein.

The Policy, the MOA, the*TWRS Pri~atization Contracts, and the four documents incorporated in the Contracts define the essential elements of the regulatory program. which will be executed by the RU and to which the TWRS Privatization Contractors must conform. The four documents incorporated in the Contracts (and also incorporated in the MOA) arc Concept of the DOE Regulatory Process for Radiologi-cal, Nuckar, and Process Safery for 1WRS PrivatiztJ-tion Contractors, DOE!RL-96-()()()5, DOE Regulaiory Process for Radiological. Nuclear, and Process Safety for TWRS Privatization Contrac-tors, DOE/RL-96-0003, Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Privatization *eon-tractors, DOEIRL-96-0006, and_

Process for Establishing a Set of Radiological, Nu-clear, and Process Safety Standards and Requirements for TWRS Privatization. DOEIRL-9~.

In the execution of the regulatory program. the RU will consider not only the relevant approaches and practices of DOE but also those of the Nuclear Regulatory Commission (NRC). The Policy states that "It is DOE's policy that TWRS privatized contractor activities be regulated in a manner that assures ade-quate radiological, nuclear, and process safety by ap-plication of regulatory concepts and principles consis-tent with those of the Nuclear Regulatory Commis-sion."

To this end. the RU will interact with the NRC (under the provi-sions of a memorandum of understanding with the NRC) during development of regulatory guidance and during execution of the regulatory program to ensure implementation of this policy.

All documents mued by the Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contractors are available to the public through the DOEJRL Public Reading Room at the Washington State University, Tri-Cities Campus, 100 Sprout Road, Room 130 West, Richland, Washington.

Initial Quality Assurance Program Review Guidance Table of Contents

1. INTRODUCTION.......................................................................................... 1
2. PURPOSE.................................................................................................. 1
3. STRUCTURE.............................................................................................. 1
4. QUALITY ASSURANCE REQUIREMENTS...........................-.............................. 1
5. PART-A QA RELATED ACTIVITIES................................................................. 2
6. KEY 10 CFR PART 830.120 QA CRITERIA FOR PART-A...................................... 2
7. QA ATTRIBUTES AND REVIEW...................................................................... 3 7.1 Introduction............................................................................................................................3 7.2 General Quality Assurance Program Requirements.........................................................................4 7.3 Quality Assurance Criteria That Apply To Work Management.........................................................5 7.4 Quality Assurance Criteria That Apply To Work Performance.......................................................... 8 7.5 Quality Assurance Criteria That Apply To Work Assessment........................................................ 12
8. OTHER CONSIDERATIONS.......................................................................... 13
9. SOURCES...................... :......................................................................... 13
10. ABBREVIATIONS..................................................................................... 14
11. GLOSSARY............................................................................................. 14 APPENDIX A. ADDENDUM TO CRITERION 6, DESIGN......................................... 16 RUREG-96-01 Rev 0, 10-25-96

Initial Quality Assurance;: Program Review Guidance (This page intentionally left blank.)

ii Rev 0, I 0-25-96 RUREG-96-01

1.

INTRODUCTION Under its Contract, each TWRS Privatization Con-tractor is required to submit an initial Quality Assur-ance Program (QAP) that supports performance of Part-A activities 45 days after Contract award. The Contract further stipulates that the QAP be based on existing Contractor systems wherever possible. The Department of Energy (DOE) Regulatory Unit (RU),

Office of Radiological, Nuclear, and Process Safety Regulation for TWRS Privatization Contractors at the Richland Operations Office (RL), will provide comments _within 15 days of the Contractor's sub-mission. This Guide provides the basis which the RU will use to review the Contractor's initial QAP and develop comments.

The Reviewer should be aware that new rules and regulations establish requirements that go beyond a prescriptive approach to product quality, to a tailored approach to the quality of all Contractor activities consistent with their importance.

Particularly, the DOE/RL Regulatory Unit views the Contractor's QAP as a primary tool of Contractor management to guarantee that quality achievement is integrated into the Contractor's total activities through integrated planning, implementation, assessment, and corrective actions. It also means that the quality assurance ap-proaches should be tailored to the activity, for exam-ple, the quality assurance for design (application of defined techniques) and for analyses (intellectual in-quiry activities) may differ in approach and applica-tion. Since the DOE/RL Regulatory interest in qual-ity assurance is dominated by interest in the Contrac-tor management's achievement of meaningful quality for all activities that influence safety, the Reviewer should expect the QAP to be an essential integrated feature of the Contractor's Integrated Safety Manage-ment Plan (ISMP).

2.

PURPOSE The DOE has issued, 10 CFR Part 830.120, Quality Assurance Requirements (the Rule), and a related im-plementation guide which apply to the TWRS Priva-tization Contractors.

When the Rule was issued, DOE practices and requirements focused mainly on management and operating contractors. While these practices are still generally applicable, some differing perspectives also exist that reflect the present rela-tionship between the TWRS Privatization Contrac-tors and the DOE. These differing perspectives are expressed here.

This Guide accommodates the new relationship be-tween the DOE and its Privatized Contractors; incor-Initial Quality Assurance Program Review Guidance porates the effects of the requirements in the docu-ment Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Privatiza-tion Contractors, DOE/RL-96-0006; Revision O; and addresses the requirements in the Contract for Con-tractor submittal of an initial QAP.

An effort has been made to focus on known Part-A activities. The Reviewer should note that the initial QAP is an in-terim measure to establish a basis for Contractor work until the standards are established. The QAP, based on the results of the standards identification process should be submitted for approval as part of the ISMP.

Finally, this Guide also addresses Re-viewer actions to support the potential future transi-tion to Nuclear Regulatory Commission (NRC) regu-lation. (See Section 8.0.)

3.

STRUCTURE Section 4 identifies the requirements and provides ~

ditional considerations important to the review of the QAP. Section 5 lists Part-A activities that should be included by the Contractor in the initial QAP and provides the guiding principle for judging the Con-tractor's selection of other Part-A activities that should also be included in the QAP. Section 6 pro-vides the Quality Assurance Criteria considered to be most important to Part-A activities. Section 7 pro-vides specific guidance for the review of the initial QAP and identifies attributes the RU considers impor-tant and which constitutes its expectations for the Contractor's QAP. Section 8 notes the possible tran-sition of the regulatory program to the NRC in the future and provides additional instructions to the Re-viewer related to that transition. This Guide reserves the use of italicized text to set apart text quoted from authoritative sources.

4.

QUALITY ASSURANCE REQUIRE-MENTS In the four documents describing DOE's regulatory approach, DOE'JRL-96-0002 through 0006, there are three tenets that are basic to the TWRS Privatization Contractors for radiological, nuclear, and process safety. The Contractor is responsible for:

Achieving adequate safety; Complying to applicable laws, and legal re-quirements, and Conforming to top-level safety standards and principles stipulated by the DOE.

The QA principles stipulated by DOE, which are con-tained in the document Top-Level Radiological, Nu-clear, and Process Safety Standards and Principles for RUREG-96-01 Rev 0, 10-25-96 Page 1 of 18 i

Initial Quality Assurance Program Review Guidance TWRS Privatization Contractors, DOEJRL-96-0006; Revision 0, are as follows:

4.1.4.1 Safety/Quality Culture A safety/quality program should be established

  • that governs the Contractor's actions and interac-tions of all personnel and organizations engaged in activities related to the facility and emphasizes excellence in all activities. The Contractor should have safety and quality responsibilities specifically identified in its operations.

4.1. 6.1 Qu~lity Assurance Application Quality assurance and quality control should be

. applied throughout all phases and to all activities associated with the facility as part of a compre-hensive system to ensure with high confidence that all items delivered and services and tasks per-formed meet required standards.

This same source aiso stipulates other principles re-lated to activities subject to quality control including Configuration Management, Section 4.1.5; Design, Section 4.2.1; and Proven Engineering Prac-tices/Margins, Section 4.2.2.

The Reviewer guidance provided herein is based on the principles found in the document containing the top-level safety standards and principle stipulated by DOE, the QA Rule, that is, 10 CFR Part 830.120, and the companion guidance document to the Rule, Implementation Guide for use with 10 CFR Part 830.120 Quality Assurance, G-830.120-Rev. 0, April 15, 1994.

5.

PART-A QA RELATED ACTIVITIES Under the phased structure of the 1WRS Privatization Program, work related to the design spans Part A aoo Part B of Phase I (see Preface on inside of the cover).

The Contractor is responsible for identifying all Part-A activities which will be subject to QA. This selec-tion will be subject to review.

Part-A activities are limited by the Contract to design and design-related activities. While the safety signifi-cance of Part-A activities to the Part-A period of work is limited, the influence of Part-A activities on Part-B activities is of interest in the initial QAP review.

Some of the Part-A activities that must be empha-sized in the initial QAP are safety deliverables of the Contract.

Based on the Contract, the Reviewer should expect the Contractor's activities that support the develop-ment of Part-A deliverables for radiological, nuclear, and process safety (Table S4-1) 1, and the design ac-tivities to be emphasized in the initial QAP. In addi-tion to design, the deliverables of key interest to the RU include:

  • ' Safety Requirements Document Integrated Safety Management Plan Hazards Analysis Report Employee Concerns Management System Radiation Exposure Standard for Workers Under Accident Conditions Quality Assurance Program Initial Safety Assessment As mentioned earlier, the Contractor's selection of other Part-A activities to be included in the initial QAP should be considered and reviewed. The guiding principle governing the Contractor's selection of other Part-A activities is to choose those activities which will have a lasting influence on the safety to be achieved in Part B. The Reviewer should expect the Contractor to declare which of the Part-A results they will use in Part B should their participation con-tinue, and should expect those activities to be empha-sized in its QAP.

fi.

KEY 10 CFR PART 830.120 QA CRITERIA FOR PART-A The Rule has three general requirements and ten spe-cific Criteria. Section 5 addresses Part-A activities that should be emphasized in the initial QAP.

As noted in the next section, the Reviewer should expect the initial QAP to include a discussion of how the general requirements and each QA Criterion will be satisfied. Because the profile of activities in Part A is limited to design and design-related activities and not to construction, operations, or deactivation, and be-cause the Contractor is required to apply the Criteria using a graded approach, the Reviewer should expect the Contractor to provide a greater level of detail for certain Criterion than for others.

The Reviewer should balance the review with the in-dividual importance of the Criterion. Procurement, for example, is not a large part of Part-A activities.

However, if Part-A activities involve procurement implementation standards and practices for Part B, procurement of design or design development studies, this Criterion should be considered. The following table lists the Rule's Criteria, a judgment as to their*

Part A deliverables for Radiological, Nuclear, and Process Safety contained in Table S4-l, Section C,

p. 22, of 1WRS Privatization.Request for Proposals, DE-RP06-96RL13308, February 1996.

Page 2 of 18 Rev 0, 10-25-96 RUREG-96-01

expected use in Part A, and the reasoning for that judgment. Table 1 is to be used by the Reviewer in preparing for the review. It should not be construed Initial Quality Assurance Program Review Guidance as providing special relief to the Contractor from any obligations under the Rule.

Table 1.

Relative Measure of Criteria Applicability to Part-A Work CONSIDERATION OF THE RULE'S 10 CRITERIA IN THE REVIEW OF CONTRACTOR'S PART-A QA PROGRAM CRITERION TITLE EXPECTED JUSTIFICATION USE IN PART 1

Program 2

Qualification & Training of Personnel 3

Quality Improvement 4

Documents & Records 5

Work Processes 6

Design 7

Procurement 8

Inspection and Acceptance Testing 9

Management Assessments 10 Independent Assessments

7.

QA ATTRIBUTES AND REVIEW 7.1 Introduction The intent of this Guide is to encourage the Reviewer to judge the adequacy of the Contractor's measures to accomplish quality, rather than its compliance with established prescriptions. Ultimately, the Contractor should be judged on the effectiveness of its measures to achieve excellence. This will require the Contrac-tor to adopt a coherent and rational approach that >>

dresses the QA needs and is effective for achieving quality in Part-A activities. The Reviewer should be receptive to any competent and rational approach oo-veloped within the framework of the Rule and the top-level safety standards and principles stipulated by A

Greater To achieve Part-A deliverables the organiza tion must be well defined and functional.

Greater Qualified personnel strongly impact the quality of the design.

Lesser Design controls probably suffice.

Greater Consideration should be given to D&R storing media, retention & retrieval.

Greater Engages management and worker in,quality design processes.

Greater This is the main emphasis of Part A.

Lesser Limited to procurement of design and de-sign development studies in Part A.

Lesser May have some implications in defining item or process prototypes.

Greater Management needs organizational control.

Lesser In Part A, assessments are part of design control.

DOE. A common sense approach to the requirements as they apply to Part-A activities is expected. Re-quirements having major influence on the quality of Part-A, safety-significant results should receive more detailed and extensive treatment. Those requirements justifiably meriting reduced attention, may receive less.

The guidance below is organized to follow the struc-ture of the Rule.

There are general requirements (called General Quality Assurance Program Require-ments) for the QAP, as well as specific Criteria that should be satisfied by the QAP. The General Quality Assurance Program Requirements noted below >>

dress: 1) demonstrating how the ten Criteria are satis-fied, 2) using the graded approach, and 3) using the appropriate standards. These general requirements in-RUREG-96-01 Rev 0, 10-25-96 Page 3 of 18

Initial Quality Assurance Program Review Guidance fluence the Contractor's use of the ten Criteria. The Reviewer is to judge the adequacy of the Contractor's approach to these general requirements.

In the Rule, and in this Guide, the ten Criteria are grouped into three sections: Management, Perform-ance, and Assessment. Each of the ten Criteria has a number of specific requirements. Reviewers should judge the adequacy of the Contractor's response to sat-isfying each Criterion.

For each requirement listed below, this section quotes related requirements contained in the top-level safety standards and principles stipulated by DOE, and pro-vides reviewer guidance on what the Reviewer ought to expect in the QAP and important considerations for judging the adequacy of the Contractor's approach.

Contractor use of related sections in the companion document to the Rule, Implementation Guide for JO CFR Part 830./20, G-830.120-REV. 0, April 15, 1994, is acceptable, insofar as, all of the QA require-ments for TWRS Privatization Contractors are irl-dressed. Contractor use of NQA-12 style information is also acceptable provided the information is organ-iz.ed and presented in a manner which demonstrates that the requirements of the Rule are effectively satis-fied.

During the review process, the Reviewer should: 1) become familiar with the Implementation Guide for the Rule, 2) read the review statements in this section for each requirement, 3) become familiar with the Contractor's QAP and implementation plan, if pro-vided, 4) evaluate the Contractor's QAP against the review statements in this Guide and relative to the scope of work for Part A, and 5) judge if the QAP, if implemented, would satisfy the requirements of the Rule and the related top-level safety standards aoo principles stipulated by DOE. The Reviewer, there-fore, needs to have a working knowledge of quality requirements, methods for implementing quality pro-grams, and of the TWRS Privatization Program.

7.2 General Quality Assurance Program Requirements There are three general requirements of 10 CFR Part 830.120, Quality Assurance Requirements, part (b)

Quality Assurance Program:

Requirement 1 A QAP shall include a discussion of how the criteria of paragraph (c) of this section will be satisfied.

ASME NQA-1-1994 Edition, Quality Assurance Re-.

. quirements for Nuclear Facility Applications.

Review Under the Rule there is flexibility for the Contractor to devise its own approach for achieving quality. The Contractor may choose those measures upon which it intends to rely. However, with the un-certainty introduced by this flexibility, a Contractor's stated commitment in the QAP to comply with the ten Criteria does not provide sufficient information to judge the adequacy of its approach.

The Reviewer should expect a discussion of what activities will be placed under the QAP and how QA measures will be used to achieve quality. This discussion will include methods and systems to be used and specifically iden-tify how the Criteria are to be satisfied. The use of existing systems is acceptable, provided they meet adequate standards for the functions they are intended to perform. For either existing or proposed systems, the Reviewer should expect a description of the func-tions to be performed and the standards to which they conform.

Requirement 2 The criteria of paragraph (c) of this section shall be applied using a graded approach.

Review All Contractor activities are subject to QA but not all processes, items, activities, or services have the same effect on quality or safety. A graied approach is to be used in the application of the Crite-ria. According to the Rule:

"Graded Approach means a process by which the level of analysis, documentation, and actions necessary to comply with a requirement in this Part are commensurate with:

(I) The relative importance to safety, safeguards, and security; (2) The magnitude of any hal.lJrd involved; (3) The life cycle stage of a.facility;

( 4) The programmatic mission of a facility; (5) The particular characteristics of a facility; and

( 6) Any other relevant factor. "

The Reviewer should expect a presentation of the ra-tionale and method used by the Contractor to dis-criminate between levels of analysis, documentation, and actions, as well as a description of the method's application and its results. The rationale should take into consideration the above six factors as they apply to the Contractor. The objective of the graded ap-proach is to establish the level of effort necessary to achieve quality; therefore, the Reviewer should judge the adequacy of the process applied to activities in the context of their importance to safety and quality aoo their continued influence in Part B.

Requirement 3 The contractor shall use appropriate standards, whenever applicable, to develop and im-plement its QAP.

Page 4 of 18 Rev 0, 10-25-96 RUREG-96-01

Review For the Privatization Contractors, "The DOE regulatory approach requires that the Contractor take an active and significant role in identifying and recommending the standards and requirements it will use to achieve adequate safety for its specific activities". 3 The Reviewer should expect a presentation of the standards used by the Contractor to develop the initial QAP and a justification for their use. Because the re-sults of the standards and requirements identification process will not be available for the initial QAP, the Reviewer should consider the acceptability of the standards in the context of commercial and DOE prac-tice such as ASQC E44, ASME NQA-1 5, and ASQC Q 9001 6* As a minimum, the Reviewer should con-firm the Contractors use of the Rule and QA-related top-level safety standards and principles stipulated by DOE in the QAP.

7.3 Quality Assurance Criteria That Ap-ply To Work Management Criterion 1: Program Introduction The general requirements just discussed in Section 7.2 are concerned with measures to achieve safety, the necessary level of effort, and the use of ac-ceptable standards. This Criterion addresses the man-agement systems for implementing the QAP.

Requirement 4 A written QAP shall be developed, implemented, and maintained.

Review The Reviewer should expect a presentation of the Contractor's management system.

The man-agement system should include the Contractor's methods for managing, performing, and assessing the adequacy of work, including work assigned to partners or parties outside the organization.

The Reviewer should evaluate the Contractor's man-agement system's capability to achieve quality, with emphasis on the contractor's requirements for man-agement qualification and participation.

The Re-viewer should be satisfied that the method and re-sources for developing, implementing, and maintain-DOE/RL-96-0005; Revision 0, February 1996, p. 1.

ANSUASQC Standard E4, Quality Systems Require-ments for Environmental Programs, 1994.

ASME NQA-1-1994 Edition, Quality Assurance Re-quirements for Nuclear Facility Applications.

ANSUASQC-Q9001, Quality Systems -Modelfor Quality Assurance in Des_ign!Development, Produc-tion, Installation, and Servicing, 1993.

Initial Quality Assurance Program Review Guidance ing the QAP are adequate. The Reviewer should con-firm that the Contractor's policies and requirements establishing the management system include provi-sions for management's development of measures to ensure that all personnel, including management, im-plement the management system.

The Reviewer should identify a commitment to develop an imple-mentation plan and evaluate the methods of manage-ment implementation and maintenance. Maintenance considerations may include: I) periodic program re-views, 2) demonstration of adequacy, 3) provisions for changes, and 4) method of approval.

The Re-viewer should identify the Contractor's policies arxl requirements for assessing the adequacy of work.

Requirement 5 The QAP shall describe the organiza-tional structure, functional responsibilities, levels of authority, and interfaces for those managing, perform-ing, and assessing the work.

Review The Reviewer should evaluate the adequacy of the Contractor's organizational structure and the provisions enabling those personnel responsible for developing and implementing the QAP to have ade-quate lines of communication and sufficient influence to be effective. The Reviewer should see a presenta-tion of the function of the various parts of the organi-zation, their responsibilities, and how each supports the mission, i.e., organizational unit responsibilities, the level of authority for each tier of the organization, the interfaces among personnel managing, perform-ing, and assessing the work, and authorities, respon-sibilities, and interfaces among multiple contractors or subcontractors. The communication among differ-ent organizations and between the organization and parties outside the organization should be described.

The Reviewer should identify and evaluate a method for resolving inconsistencies among organizations and between organizations and parties.

Requirement 6 The QAP shall describe the manage-ment processes, including planning, scheduling, cn1 resource considerations.

Review The Reviewer should identify and evaluate the adequacy of the Contractor's policies and require-ments that establish the management processes. The Reviewer should identify and evaluate the Contrac-tor's cost schedule control system (CSCS) and the Management Information System (MIS).

The Re-viewer should assess how the CSCS will be used, in-cluding the ability to track program progress and han-dle resource loading. The Reviewer should determine if the MIS is in place, and assess how it will be used and its adequacy to accommodate interfaces with all organizations and parties.

Rl./REG-96-01 Rev 0, 10-25-96 Page 5 of 18

Initial Quality Assurance Program Review Guidance Criterion 2: Personnel Training and Qualification Introduction This Criterion addresses the ability of personnel to perform their work.

It applies to all Contractor activities, including design, and should be used consistent with the results of the graded ap-proach. In evaluating the Contractor's approach, the Reviewer should consider the constraints imposed by the dynamic nature of Part-A activities and the limited period of work on the Contractor's selection of meth-ods to satisfy this Criterion.

Requirement 7 Personnel shall be trained and quali-fied to ensure they are capable of performing their as-signed work.

Related toP:level safety standards and principles stipu-lated by DOE 4.3.4.1 Personnel Training Personnel engaged in activities bearing on facil-ity safety should be trained and qualified to per-form their duties.

Review The Reviewer should identify and evaluate the Contractor's policies, requirements, and methods to ensure that personnel are trained and qualified to perform their work.

Consider the following ques-tions. Are the personnel required to have an adequate understanding of the work they are to perform? Does the Contractor certify the qualifications of its person-nel and is the process adequate? Has the Contractor identified the skills required to perform the work of Part A, such as knowledge of systems engineering methods, special computer codes, etc.?

The Reviewer should identify and evaluate the Con-tractor's provisions for training. The evaluation may consider 1) formal and informal training, such as on-the-job training, 2) training formats including semi-nars and classroom instruction, 3) establishing mini-mum requirements for each job task, 4) instructor qualification and experience, 5) appropriate training materials and facilities, and 6) assessing personnel proficiency.

Requirement 8 Personnel shall be provided continu-ing training to ensure that job proficiency is main-tained.

Related JOJ>:Ievel safety standards and principles stipu-lated by DOE 4.3.4.2 Training Programs Programs should be established for continual training of operations and maintenance personnel to enable them to perform their duties safely and efficiently.

4.3.4.3 Conditions Beyond Design Basis Operating staff should be trained and retrained in the procedures to follow if conditions exceed the design basis of the facility.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements to establish continuing training. The constraints imposed by the dynamic nature of Part-A activities and the limited pe-riod of work should be considered while gauging the importance and judging the adequacy of the Contrac-tor's approach. The Reviewer should consider the ap-proach of using refresher courses to ensure personnel are trained in current procedures and on organizational processes, particularly if a condition adverse to quality

  • may involve processes being performed incorrectly.

The evaluation may consider 1) a periodic assessment of training needs, 2) an assessment of process prob-lems that may be solved by training, 3) instructor qualification and experience, 4) appropriate instruction materials and facilities, and 5) assessment of person-nel proficiency.

Criterion 3: Quality Improvement Introduction This Criterion addresses the processes to continually improve quality. It applies to all Con-tractor activities, including design, and should be used consistent with the results of the graded approach. In the evaluation, the Reviewer should consider the con-straints imposed by the dynamic nature of Part-A ac-tivities and the limited period of work on the Contrac-tor's selection of methods to satisfy this Criterion.

Requirement 9 Processes to detect and prevent quality problems shall be established and implemented "Quality Improvement is a dual fold process of addressing and remedying sporadic problems, sud-den adverse changes in the status quo of a work process, and solving chronic problems, long-standing adverse conditions in a work process, i.e. continual scrap of several percent, to improve a work process by changing the status quo to a new improved level. "1 Derived from Quality Planning and Analysis, by J.

M. Juran and Frank M. Gryna, Jr., McGraw-Hill, 1980, p. 99.

Page 6 of 18 Rev 0, 10-25-96 RLJREG-96-01

The Reviewer should identify and evaluate the Con-

. tractor's policies, requirements, and methods to detect and prevent quality problems, take prompt, effective, and complete corrective actions, and improve per-formance. The Reviewer should consider Contractor's management measures to document and communicate the policies to all levels of the organization and among organizations, to implement related practices, including those to improve worker awareness of the importance of quality, to encourage participation of all workers in quality improvement, and to vest authority in workers to identify quality problems and initiate corrective actions. The Reviewer should con-sider the use of methods like the Shewhart Cycle (also known as the Plan, Do, Check, Act or POCA cycle) by the Contractor to formalize the process of improving planning activities, procedures, processes, and designs.

Requirement 10 Items, services, and processes that do not meet established requirements shall be identi-fied, controlled, and corrected according to the impor-tance of the problem and the work affected. Correc-tion shall include identifying the causes of problems and working to prevent recurrence. Item characteris-tics, process implementation, and other.quality-related infonnation shall be reviewed and the data analyz.ed to identify items and processes needing improvement.

Review The Reviewer should identify and evaluate the Contractor's policies for implementing procedures that identify, control, and correct quality deficiencies.

The Reviewer should consider the Contractor's use of methods for controlling items, services, or processes that do not meet requirements or specifications such as a classification system using the structure: accept, reject, repair, rework, use-as-is, or re-evaluate; and the methods for identification and correction including the tools of tracking, trending, and root cause analysis to ensure that the underlying causes of quality problems are averted.

Criterion 4: Documents and Records Introduction This Criterion addresses the control of documents and record functions related to processes, requirements, and design. It provides requirements af-fecting matters such as configuration control, related to work performance, such as design.

Requirement 11 Documents shall be prepared, re-viewed, approved, issued, used, and revised to pre-scribe processes, specify requirements, or establish design.

Review A document is recorded information that cb-scribes, specifies, reports, certifies, requires, or pro-Initial Quality Assurance Program Review Guidance vides data or results8* It controls policies, administra-tive and technical information regarding processes, re-quirements, and design. The Reviewer should identify and evaluate the Contractor's policies and require-ments for document control and the implementation of a documents control process. The Reviewer should consider measures that ensure all elements of the or-ganization establish document control procedures.

The Reviewer should identify and evaluate the Con-tractor's requirements and standards for document preparation, review, approval, use, access, and revi-sion. The Reviewer should consider approaches for controlling distribution, identifying recipients, and es-tablishing required actions when documents are re-vised or canceled consistent with the results of the graded approach.

The Reviewer should consider measures that ensure qualified reviewers based on sub-ject matter expertise.

The Reviewer should also evaluate the Contractor's QAP document control pro-visions against the requirements for configuration management in the top-level safety standards and principles stipulated by DOE.

(See Criterion 5, Work Processes, and Criterion 6, Design.)

Requirement 12 Records shall be specified, prepared, reviewed, approved, and maintained.

Review A record is recorded information that is re-tained for its expected future value.9 The Reviewer should identify and evaluate the Contractor's policies and requirements for the specification, preparation, re-view, approval, and maintenance of records. The Re-viewer should consider how records are detemrined, the process of preparation, the method of review, the process of approval, and the system for maintenance in light of a graded approach. The Reviewer should evaluate the Contractor's _record control system con-sidering the requirements for retention, protection, preservation, changes, and traceability.

He or she should assess the adequacy of requirements to preserve the integrity of the storage system and the media The Reviewer should use the records control system requirements of NARA (National Archives and Rec-ords Administration) to assess control of the TWRS Privatized Program Government records.

From IO CFR Part 830.3, Definitions: Document means recorded infonnation that descn'bes, speci-fies, reports, certifies, requires, or provides data or results. A document is not considered a record until it meets the definition of a record.

From IO CFR Part 830.3, Definitions: Record means a completed document or other media that provides objective evidence of an item, service, or process.

RUREG-96-01 Rev 0, 10-25-96 Page 7 of 18

Initial Quality Assurance Program Review Guidance 7.4 Quality Assurance Criteria That Ap-ply To Work Performance Criterion 5: Work Processes Introduction This Criterion addresses measures to achieve process goals. It applies to all Contractor ac-tivities such as planning, scheduling, accounting, project management, design, analysis, fabrication, procurement, construction, installation, testing, op-eration, modification, maintenance, and deactivation consistent with the results of the graded approach.

The Reviewer si:\\cmld consider the scope of Part-A ac-tivities in the evaluation of the Contractor's ap-proach. In particular, Requirements 14, 15, and 16 should require less detailed information from The Contractor.

Reguirement 13 Work shall be performed to estab-lished technical standards and administrative controls using approved instructions, procedures, or other ap-propriate means.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements* for such management controls as providing criteria for accept-able work performance, planning and designing work processes; ensuring qualified personnel to accomplish the work; ensuring personnel talce responsibility for the quality of their own work and that they follow prescribed standards, procedures, or instructions.

. Documents expressing management controls should

1) clearly identify authorities, responsibilities, and in-terfaces, 2) be readily accessible to and usable by the workers, and 3) address work process elements such as methods to prevent use of incorrect or defective items.

The Reviewer should also evaluate the Contractor's work process measures intended for use in Part B.

The Reviewer should evaluate the attention given to each important element of each work process: people, equipment, environmental conditions, supply, man-agement, support, resources, and requirements, based on the results of the graded approach.

Reguirement 14 Items shall be identified and con-trolled to ensure their proper use.

Review "Item is an all-inclusive term used in place of any of the following: appurtenance, assembly, component, equipment, material, module, part, struc-ture, subassembly, subsystem, system, unit, or sup-port system". 10 10 From 10 CFR Part 830.3, Definitions: Item is an all-inclusive term used in place of any of the follow-ing: appurtenance, assembly, component, equip-The Reviewer should identify Contractor's policies and requirements for identifying and controlling items. The Reviewer should expect the Contractor to use a system to inventory items and a method to track and control items and accompanying documentation, depending on importance. The Reviewer should con-firm Contractor's management's commitment to a system that is readily usable by workers.

The Re-viewer should identify Contractor's policies and re-quirements ensuring that personnel talce responsibility for proper use of the items. The Reviewer should see that the following are addressed: one of a kind items, items specific to a particular craft, and common items that may be misused.

Reguirement 15 Items shall be maintained to prevent their damage, loss, or deterioration.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for a proc-ess or procedure that ensures item maintenance or special care according to their importance (graded ap-proach). The Reviewer should consider measures in the maintenance management program to promote worker safety and environmental protection, and to monitor item condition. The Reviewer should con-sider the following attributes: maintenance require-ments, an item control process, maintenance sched-ules, personnel or organization identified for mainte-nance, assignment of authority and resources to meet requirements, handling and storage requirements to prevent damage, a method of measuring deterioration, and establishing metrics for determining deterioration.

A provision should be included for identifying items with unique requirements such as in-storage mainte-nance, limited shelf life, or ones that pose a particular hazard to the environment, facilities, or personnel.

Reguirement 16 Equipment used for process nwnitor-ing or data collection shall be calibrated and main-tained.

~

The Reviewer should identify and evaluate the Contractor's policies and requirements for identi-fying, controlling, and maintaining equipment used for monitoring processes or collecting process or other data. The Reviewer should identify and evaluate the Contractor's requirements for a formal, docu-mented, calibration program. The Reviewer should consider requirements for 1) calibration standards traceable to the National Institute of Standards arxl Technology NIS1), or some other nationally recog-nized standard, or a method that gives the basis for the calibration; and 2) procedures and training for those workers who perform calibrations. The training pro-ment, material, module, part, structure, subassem-bly, subsystem, system, unit, or support system.

Page 8 of 18 Rev 0, 10-25-96 RUREG-96-01

gram should include training for personnel that main-tain such equipment.

Criterion 6: Design Introduction This Criterion addresses the definition, control, and verification of design and is more specific than those measures stipulated for Criterion 5, Work Processes. It applies to the design and supporting ac-tivities such as analysis.

This Criterion recognizes the need for additional measures, including the control of design inputs, outputs, verification, configuration and design ~hanges, documentation, records, and tech-nical interfaces consistent with the results of the graded approach. This Criterion ensures that adequate measures exist for systems, structures, and compo-nents important to safety. The Reviewer should rec-ognize the potential importance of this Criterion to Part-A activities.

Principles stipulated by DOE that are related to the act.1V1t1es subject to this Criterion include "Configuration Management,"

Section 4.1.5, "Design," Section 4.2.1, and "Proven Engineering Practices/Margins," Section 4.2.2 of the Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Privatization Contractors, DOFJRL-96-0006; Revision 0. Sections 4.1 and 4.2 are included in Appendix A for the Reviewer's con-venience.

Requirement 17 Items and processes shall be de-signed using sound engineering/scientific principles and appropriate standards.

Related top-level safety standards and principles stipu-lated by DOE.

4. 2. 2.1 Proven Engineering Practices Safety technologies incorporated into the facility design should have been proven by experience or testing and should be reflected in approved codes and standards. Significant new design features should be introduced only after thorough research and model or prototype testing at the component, system, or facility level, as appropriate.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for using sound engineering/scientific principles.

The Re-viewer should consider the use of accepted design practices; valid analytical methods, tools, and data; proven technology or measures to demonstrate ade-quacy of new technology; and formal design processes that ensure quality. The Reviewer should confirm the Contractor's measures that address the QA methods Initial Quality Assurance Program Review Guidance unique to analysis. The Reviewer should also verify measures to preclude the use of unverified design data and ensure that appropriate verification or qualifica-tion testing is completed before design data are used in subsequent activities, consistent with the results of the graded approach. The.Reviewer should identify and evaluate the Contractor's requirements for identi-fying and using suitable standards appropriate to the design product.

Requirement 18 Design work, including changes, shall incorporate applicable requirements and design bases.

Related top-level -safety standards and pnnciples stipu-lated by DOE 4.1.5 Configuration Management 4.1.5.1 Formal Configuration Management Formal configuration management should be ap-plied to all facility activities during the pro-gram's lifetime to ensure that programmatic ob-jectives, including safety, are fully achieved.

Work should be performed and controlled accord-ing to pre-approved plans and procedures that clearly delineate responsibilities. Documented records should be retained 4.1.5.2 Contractor Design Knowledge The Contractor operating organizations should become and remain familiar with the features and limitations of components included in the design of the facility. They should obtain appropriate input from the design organiZfltion on pre-operational testing, operating procedures, and the planning and conduct of training.

4.1.5.3 Design Documentation A system should be used to control and maintain accurate as-built drawings during the life of the facility.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for a for-mal process, including systems engineering, to prop-erly establish and accurately incorporate requirements and design bases into the design and design changes.

The Reviewer should verify that design changes, in-cluding those made during fabrication or construction, subsequent modifications, and any nonconforming items will be subject to design standards and controls consistent with those applied to the original design.

The Reviewer should identify requirements for con-figuration management and control to ensure that oo-RIJREG-96-01 Rev 0, 10-25-96 Page 9 of 18

Initial Quality Assurance Program Review Guidance sign documents and records are appropriately gener-ated, controlled, and retained. The following is an ac-cepted consensus standard definition for Configuration Management (CM)JJ.

"An integrated management program that estab-lishes consistency among design requirements, physical configuration, and facility documenta-tion, and maintains this consistency throughout the life of the facility as changes occur. The CM program consists of CM functions associated with the following program elements: program management, design requirements, document con-trol, change _control, and assessments. The CM program also includes design reconstitution and material condition and aging management as ad-junct programs."

The Reviewer should identify and evaluate the Con-tractor's requirements for a process to identify struc-tures, systems, and components (SSCs) important to safety based on the results of the graded approach am should be able to establish the life expectancy of the SSC12*

The Reviewer should also identify require-ments for design documents to. be usable b)! all em users.

Requirement 19 Design interfaces shall be identified and controlled.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for deter-mining design interfaces among interacting disci-plines or multiple contractors, both technical and ai-ministrative.

These interacting disciplines and or-ganizations should have well-defined roles with ~

spect to responsibilities,.design reviews, design-basis exchange among disciplines and organizations, deliv-erables among disciplines and organizations, and as-sociated approvals. The Reviewer should identify am evaluate the Contractor's requirements for an interface control system that avoids, or identifies and corrects conflicts.

Reguirement 20 The adequacy of design products shall be verified or validated by individuals or groups other than those who performed the work.

~

Design verification is a formal documented process to establish that the resulting system, struc-II 12 DOE-STD-1073-93-Pt. l, "Guide for Operational Configuration Management Programs," Glossary, page x.

Top-level Radiological, Nuclear, and Process Stan-dards and Principles for 7WRS Privatization Con-tractors, DOE/RL-96-0006; Revision 0, Sections; 4.2.2.2, 4.2.2.3, 4.2.7.1, and 4.2.7.2.

ture, or component will be fit for its intended use.

The Reviewer should identify and evaluate the Con-tractor's policy and requirements to verify or validate design products consistent with the results of the graded approach. Measures may include technical ~

views, peer reviews, alternate calculations, qualifica-tion testing or limited use of reviews of comparable systems. Interim reviews may be made at predeter-mined stages of development. The extent and number of reviews should be based on the importance and complexity of the design product.

The Re~ewer should confirm that technically qualified personnel, separate from those performing the design, will verify the design. The Reviewer may consider measures to promote quality improvement as part of the design verification.

Requirement 21 Verification and validation work shall be completed before approval and implementa, tion of the design.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements to verify and validate the design before its use by other organi-zations. If verification cannot be completed before use by other organizations, unverified portions of the design should be identified and controlled. In all cases the design should be verified before it is approved and implemented.

Criterion 7: Procurement Introduction This Criterion addresses the Contractor's establishing of measures to ensure that items am services provided by suppliers meet end-user require-ments consistent with the results of the graded ap-proach. The Reviewer should acknowledge the lim-ited procurement during Part-A activities in the evaluation of the Contractor's approach to this Crite-rion. Should procurement become a significant con-sideration, the Reviewer is referred to the Implementa-tion Guide for 10 CFR Part 830.120 for a fuller de-scription of the measures to be considered in the evaluation.

Reguirement 22 Procured items and services shall meet established requirements and perform as speci-fied.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for the planning and control of the procurement process con-sistent with the results of the graded approach. The Reviewer should focus on measures to ensure the pro-curement process meets end-user requirements.

Measures should provide for the clear, complete, am accurate communication of end-user requirements to

  • Page 10 of 18 Rev 0, 10-25-96 RlJREG-96-01

the supplier; meeting suppliers', designers', and end-users' requirements during production of the item or services; and delivering the product on time and main-taining it until use.

End-user requirements should include supplier docu-mentation, handling, packaging, shipping, or storage requirements.

The Reviewer should identify aoo evaluate the Contractor's policies and requirements for documenting and controlling nonconforming items or services until compliance with the technical require-ments is demonstrated; and for acceptable deviations from requirements to be documented; controlled, re-viewed, and.approved.

Requirement 23 Prospective suppliers shall be evalu-ated and selected on the basis of specified criteria.

Review The Reviewer should identify Contractor's policies and requirements to ensure suppliers are qualified to provide required items or services. The Reviewer may consider use of metrics such as per-formance history and results of supplier evaluation based on facility visits or documented evidence.

Requirement 24 Processes to ensure that approved suppliers continue to provide acceptable items t:nl.

services shall be established and implemented.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements to establish a process to continually evaluate a supplier's contin-ued capability to provide acceptable items and serv-ices. The extent and number of reviews should be based on the results of the graded approach. Enhanced reviews may be stimulated by receipt of non-conforming items from the supplier. The Reviewer may consider performance criteria such as: work ac-tivities, facility inspection, process evaluation, prog-ress reports, change information, and nonconformance reviews.

Criterion 8: Inspection and Acceptance Testing Introduction This Criterion addresses Contractor in-spection and testing provisions to verify that sys-tems, structures, and components (SSCs) are accept-able to specified requirements, consistent with the re-sults of the graded approach. The Reviewer should consider the limited use of SSCs during Part-A activi-ties in the evaluation of the Contractor's approach.

Should use of SSCs become a significant considera-tion, the Reviewer is referred to the Implementation Guide for 10 CFR Part 830.120 for a fuller descrip-tion of measures to be considered in the evaluation.

Initial Quality Assurance Program Review Guidance Requirement 25. Inspection and testing of specified items, services, and processes shall be conducted us-ing established acceptance and performance criteria.

Related top--level safety standards and principles stipu-lated by DOE 4.3.5.J Operational Testing, Inspection, and Maintenance Structures, systems, and components important to safety should be the subject of appropriate, regular preventive maintenance, inspection, and testing and servicing when needed, to ensure that they remain capable of meeting their design re-quirements throughout the life of the facility.

Such activities should be carried out in accor-dance with written procedures supported by qual-ity assurance measures.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements to establish inspection and testing of SSCs consistent with Part-A activities and the results of the graded approach.

The Reviewer should consider measures to ensure that inspection and testing acceptance and performance cri-teria are developed based on requirements, and inspec-tion and testing activities are adequately planned, con-trolled, and documented. The Reviewer should con-sider provisions to control disposition of SSCs that do not conform, including tracking, repair, replace-ment, re-testing, and revaluation to specified criteria and disposal. The Reviewer should identify measures to ensure that equipment used for inspections is ap-propriate, and that personnel performing inspections and tests are trained and qualified in the test procedures and the equipment to be used and are certified in the appropriate discipline as necessary, e.g.,

Non-Destructive Examination qualifications.

Requirement 26 Equipment used for inspections ad tests shall be calibrated and maintained.

Review The Reviewer should identify Contractor's policies and requirements, to establish a formal, documented, calibration program consistent with Part-A activities and the results of the graded approach.

Calibration standards should be traceable to a recog-niz.ed authority, such as the National Institute of Standards and Technology that gives the basis for the calibration. The Reviewer should evaluate the Con-tractor's provisions for the calibration of equipment and instruments used to establish the acceptance of items, processes, procedures or services; corrective ac-tions where out-of-calibration conditions occur; aoo the use of qualified personnel performing calibrations.

RLJREG-96-01 Rev 0, 10-25-96 Page 11 of 18

Initial Quality Assurance Program Review Guidance

7. 5 Quality Assurance Criteria That Ap-ply To Work Assessment Criterion 9: Management Assessment Introduction This Criterion addresses Contractor management awareness of its organizational perform-ance related to achieving its goals and objectives and to the provisions management uses to encourage a continuous quality improvement process and to en-sure corrective actions are promptly, effectively and completely addressed. This Criterion applies to all Contractor activities and should be used -consistent with the results of the graded approach.

The Re-viewer should consider the constraints imposed by the dynamic nature of Part-A activities and the limited pe-riod of work on the Contractor's selection of methods to satisfy this Criterion.

Reguirement 27 Management shall assess their man-agement processes.

Review This Reviewer should identify and evaluate the Contractor's policies and requirements for assess-ing management processes.

The Reviewer should consider measures to establish organizational goals and objectives, and the conduct of periodic assess-ments that evaluate the effectiveness of the entire in-tegrated management system to focus on achieving organizational goals. These measures should be con-sistent with the period of work for Part-A activities.

The Reviewer should consider management identifica-tion of 1) processes for assessment such as strategic planning, organizational interfaces, cost control, use of performance indicators, staff training and qualifica-tions, and supervisory oversight and support; 2) con-ditions such as employee knowledge, motivation, and morale; worker trust and communication; worker

  • dedication to creativity and improvement; and ooe--

quacy of human resources; and 3) work observations such as upward evaluations, worker interviews, re-view of documentation, and conduct of drills or exer-cises.

Requirement 28 Problems that hinder the organi;.a-tion from achieving its objectives shall be identified and corrected.

Review The Reviewer should identify.Contractor's policies and requirements for identification and correc-tion of problems that hinder the organization from achieving its objectives, including corrective actions.

The Reviewer should consider measures to use the in-formation acquired during assessments combined with other internal and external information to identify problems and to develop input to a continuos im-provement process. The Reviewer should evaluate the attention given by the Contractor to methods of improving processes and eliminating the barriers to achieving strategic goals and objectives.

Criterion 10: Independent Assessment Introduction This Criterion addresses management awareness of performance of work processes related to the requirements and expectations of customers aIXI toward achieving the organization's goals and objec-tives. The Reviewer should evaluate the Contractors measures to asses its establishment of the QAP aIXI implementation. The provisions for input to a con-tinuos quality improvement process should also be considered. The Reviewer should consider the con-straints imposed by the dynamic nature of Part-A ac-tivities and the limited period of work on the Contrac-tor's selection of methods to satisfy this Criterion.

Reguirement 29 Independent assessments shall be planned and conducted to measure item and service quality, to measure the adequacy of work perfonnance, and to promote improvement.

Related toP:level safety standards and principles stipu-lated by DOE and 4.3.1.5 Internal Surveillance and Audits Internal safety review procedures should be used by the Contractor to provide a continuing sur-veillance and audit of facility operational safety and to suppon the facility manager in overall safety responsibilities.

4.4.1 Safety Review Organization The Contractor should establish a framework for its safety review organizations that are responsi-ble for assuring the safety of the facility. The separation between the responsibilities of the safety review organizations and those of the other

  • organizations should remain clear so that the safety review organizations retain their independ-ence as safety authorities.

Review The Reviewer should identify and evaluate the Contractor's policies and requirements for man-agement to develop and implement an independent as-sessment program. The program should assess or-ganizations, programs, and projects with the objective of evaluating the performance of work processes, and promoting improvement with regard to requirements and expectations of DOE. The Reviewer should con-sider the establishment of specified criteria grounded Page 12 of 18 Rev 0, 10-25-96 RUREG-96-01

in a perfonnance-based approach.

The Reviewer

  • should consider the planning of assessments, and se-lection of activities for assessment, such as design, that are most directly related to final objectives, and its emphasis on safety and product quality. The Re-viewer should consider the selection of types of inde-pendent assessments such as inspections, peer and technical reviews, audits, surveillances, or combina-tions thereof; and the frequency of independent as-sessments in light of activities j)eing assessed and their importance.
  • The Reviewer should evaluate the effectiveness of the Contractor's approach to measure item and service quality, to measur~ adequacy of work perfonnance, and to promote improvement.

Requirement 30 The group performing_ independent assessments shall have sufficient authority and free-dom from the line to carry out its responsibilities.

Review The Reviewer should evaluate the independ-ence and authority afforded the Contractor's group per-forming the assessment. The Reviewer should con-sider the advisory function of the group, the level to which the group reports in the overall organization, and its independence and access to appropriate author-ity. The Reviewer should also confirm that the group would have no direct responsibilities or dependencies in the areas they are assessing. The Reviewer should also confirm that the group's role includes assisting those who are being assessed to improve quality.

Requirement 31 Persons conducting independent as-sessments shall be technically qualified and knowl-edgeable in the areas assessed.

Related top-level safety standards and principles stipu-lated by DOE 4.4.2 Qualified Personnel Internal safety oversight should be conducted by qualified personnel to ensure that the safety stan-dards are consistently met.

Review The Reviewer should identify Contractor's policies and requirements for ensuring personnel con-ducting independent assessments are technically quali-fied and knowledgeable. The Reviewer should con-sider measures to establish appropriate qualifications for the assessments and to select appropriate person-nel for conduct of the assessment. For assessments perfonned by personnel who are internal to the or-ganization, the Reviewer should identify a policy that requires the use of certified personnel, as established by Criterion 2 for assessing work. For assessments perfonned by personnel who are external to the or-ganization, the Reviewer should identify a policy that requires a certification program be established to en-Initial Quality Assurance Program Review Guidance sure the assessor's credentials qualifying them to per-form the particular assessment.

8.

OTHER CONSIDERATIONS As an additional consideration, it should be noted that the DOE intends to transition regulation of the TWRS Privatization Contractors to the NRC in the future. It will be extremely useful to document the level of consistency that exists between the Contrac-tor's initial QAP as reviewed against 10 CFR Part 830.120 and NRC requirements. Within the bounds of 10 CFR Part 830.120, the Reviewer should evalu-ate the Contractor's initial QAP for consistency with NRC QA practices related to 10 CFR 70. Inconsis-tencies with NRC requirements should be noted for use by the RU to assist the future transition.

This part of the review will not reflect on the acceptability of the Contractor's initial QAP, but is only for the benefit of the RU.

9.

SOURCES

1.

TWRS Privatization Request for Proposals, DE-RP06-96RLI3308, February 1996.

2.

10 CFR Part 820 - Procedural Rules for DOE Nuclear Activities, September 1993.

3.

G 414.1-1, Implementation Guide for the use with the Independent and Management Assess-ment Requirements of IO CFR Part 830. I 20 and the Order 5700.6C Quality Assurance, REV. 0, August 1996.

4. DOE P 450.4, Safety Management System Pol-icy, August 28, 1996.
5. ANSI/ASQC Standard E4, Quality Systems Re-quirements for Environmental Programs, 1994.
6.

10 CFR Part 830.3, Definitions, April 5, 1996.

7.

10 CFR Part 830.120, Quality Assurance Re-quirements, April 5, 1996.

8.

10 CFR Part 70, Domestic Licensing of Special Nuclear Material, as amended through September 1996..

9.

Concept of the DOE Regulatory Process for Ra-diologica~ Nuclear, and Process Safety for TWRS Privatization Contractors, DOFJRL 0005.

IO. DOE Regulatory Process for Radiological, Nu-clear, and Process Safety for TWRS Privatization Contractors, DOEIRL-96-0003.

RUREG-96-01 Rev 0, 10-25-96 Page 13 of 18

Initial Quality Assurance Program Review Guidance

11. Top-Level Radiological, Nuclear, and Process
  • Safety Standards and Principles for 1WRS Priva-tization Contractors, DOEJRL-96-0006.
12. Process for Establishing a Set of Radiological, Nuclear, and Process Safety Standards and Re-quirements for TWRS Privatization, DOEJRL-96-0004.
13. Implementation Guide for JO CFR 830.120, G-830.120-REV. 0, April 15, 1994.
14. ANSI/ASQC-Q9001, Quality Systems -Model for Quality Assurance in Design/Development, Production, Installation, and Servicing, 1993.
15. ASME NQA-1, Quality Assurance Requirements for Nuclear Facilities Applications, 1994 Edi-tion.
16. DOE 5700.6C, Quality Assurance, August 21, 1991.
17. IAEA Code on the Safety of Nuclear Power Plants: Quality Assurance, Safety Series No. SO-C-QA (Rev.I), 1988.
18. DOE Order 5000.3B, Occurrence Reporting and Processing of Operations Information, February 22, 1993.
19. Quality Planning and Analysis, J.M. Juran and Frank M. Gryria, Jr., McGraw-Hill, 1980.
20. Statistical Method from the Viewpoint of Qual-ity Control, Walter A. Shewhart, Graduate School, Department of Agriculture, Washington, D. C., 1939, and Dover in 1986.
10.

ABBREVIATIONS CFR Code of Federal Regulation CM Configuration Management DOE Department of Energy NRC Nuclear Regulatory Commission QA Quality Assurance QAP Quality Assurance Program RL Richland Operations Office RFP TWRS Privatization Request for Proposal RU Office of Radiological, Nuclear, and Process Safety Regulation (Regulatory Unit)

SSC Structures, Systems, and Components TWRS Hanford Tank Waste Remediation System

11.

GLOSSARY Administrative Controls. Provisions relating to or-ganization and management, procedures, record keep-ing, assessment, and reporting necessary to ensure safe operation of a facility; Common-Cause Failures. Dependent failures that are caused by a condition external to a system or set of components that make system or multiple component failures more probable than multiple independent fail-ures.

Common-Mode Failures. Dependent failures caused by susceptibilities inherent in certain systems or components that make their failures more probable than multiple independent failures due to those com-ponents having the same design or design conditions that would result in the same level of degradation.

Contractor(s). The private company(ies) selected to*

contract with DOE for construction and operation of the technologies and facilities necessary to retrieve, process tank waste, and deliver treated waste products to DOE for storage or disposal.

Controlled Area. The physical area enclosing the fa-cility by a common perimeter (security fence). Ac-cess to this area can be controlled by the Contractor.

The controlled area may include identified restricted areas.

~- 13 The process and the result of developing the concept, detailed plans, supporting calculations and specifications for a nuclear facility and its parts.

Desi~n Basis.

The information that identifies the specific functions to be performed by structures, sys-tems, or components of the facility and the specific values or ranges of values chosen for controlling pa-rameters as reference bounds for design.

Director of the Regulatory Unit. An individual who has been delegated the authority to execute the radio-logical, nuclear, and process safety regulation of TWRS Privatization Contractors.

Document.

Document means recorded information that describes, specifies, reports, certifies, requires, or provides data or results. A document is not consid-ered a record until it meets the definition of record.

Facility. Those buildings and equipment directed to a common purpose and those activities and supporting elements occurring at a single location.

13 Derived from the definition of design used in lAEA Code on the Safety i:,f Nuclear Power Plants: Quality Assurance, 50-C-QA (Rev.I)

Page 14 of 18 Rev 0, 10-25-96 RL/REG-96-01

Graded A12proach. A process by which the level of analysis, documentation, and actions necessary to comply with a requirement in this part are commen-surate with:

1) The relative importance to safety, safeguards, aoo security;
2) The magnitude of any hazard involved;
3) The life cycle stage of a facility;
4) The programmatic mission of a facility;
5) The particular characteristics of a facility; and
6) Any other relevant factor.

Integrated Safety Management Plan CTSMP) Evalua-tion Report. The document, approved and issued by the Director of the Regulatory Unit, that addresses the adequacy of the Contractor's Integrated Safety Man-agement Program as reflected in its Integrated Safety Management Plan.

Integrated Safety Management Program. A set of in-tegrated activities that is directed toward the manage-ment or control of radiological, nuclear, and process hazards such that adequate protection is provided to workers, the public, and the environment.

Item. Item is an all-inclusive term used in place of any of the following: appurtenance, assembly, com-ponent, equipment, material, module, part, structure, subassembly, subsystem, system, unit, or support systems.

Nonreactor Nuclear Facility. Those activities or op-erations that involve radioactive and/or fissionable materials in such form and quantity that a nuclear hazard potentially exists to the employees or the gen-eral public. Incidental use and generating of radioac-tive materials in a facility operation (e.g., check ml calibration sources, use of radioactive sources in re-search and experimental and analytical laboratory IK:-

tivities, electron microscopes, and X-ray machines) would not ordinarily require the facility to be included in this definition. Transportation of radioactive mate-rials, accelerators and reactors and their operations are not included. The application of any rule to a nonre-actor nuclear facility shall be applied using a gra:led approach. Included are activities or operations that:

I) Produce, process, or store radioactive liquid or solid waste, fissionable materials, or tritium;

2) Conduct separations operations;
3) Conduct irradiated materials inspection, fuel fabri-cation, decontamination, or recovery operations;
4) Conduct fuel enrichment operations;
5) Perform environmental remediation or waste man-agement activities involving radioactive materials; or
6) Design, manufacture, or assemble items for use with radioactive materials and/or fissionable mate-Initial Quality Assurance Program Review Guidance rials in such form or quantity that.a nuclear ha7.a1d potentially exists.

Normal Qperation. Steady-state operation and those departures from steady-state operation that are ex-pected frequently or regularly in the course of facility operation, system testing, and maintenance. It in-cludes conditions such as startup, shutdown, standby, anticipated operational occurrences, operation with specific equipment out of service as permitted by the approved operational constraints, and routine inspec-tion, testing, and maintenance of components and systems during any of these conditions if it is consis-tent with the approved operational constraints.

Nuclear Facility. Reactor and nonreactor nuclear fa-cilities.

~- (Related to Safety) Any activity involving a highly hazardous chemical including use, storage, manufacturing, handling, or the on-site movement of such chemicals, or a combination of these activities.

Process. (Related to Quality Assurance) A series of actions that achieves an end or result.

Process Safety. The operation of facilities that han-dle, use, process, or store hazardous. materials in a manner free of episodic or catastrophic incidents.

However, the handling, use, processing, and storage of materials with inherent hazardous properties can never be done in the total absence of risk.

Process safety is an ideal condition towards which one strives.

Public. Individuals who are not occupationally en-gaged at the Hanford Site.

.Qualin'... The condition achieved when an item, serv-ice, or process meets or. exceeds the user's* require-ments and expectations.

Oua)jty Assurance.

All those actions th~t provide confidence that quality is achieved.

Quality Assurance Program or OAP.

The overall program established to assign responsibilities arxi authorities, define policies and requirements, and pro-vide for the performance and assessment of work.

&!;;Qm. A completed document or other media that provides objective evidence of an item, service, or process.

Re~lat01:y Unit. The organization reporting to the Director of the Regulatory Unit dedicated to support-ing the Director in executing regulatory authority.

Reliability Tar,:ets. Quantified probabilistic expecta-tions that a component, equipment, or system will perform its intended function satisfactorily under given circumstances, such as environmental condi-tions, limitations as to operation time, and frequency and thoroughness of maintenance for a specified pe-RIJREG-96-01 Rev 0, 10-25-96 Page 15 of 18

Initial Quality Assurance Program Review Guidance riod of time. Identified important to safety items are expected to perform their function satisfactorily through all design basis accident conditions.

Requirements.

Standards that are mandated by an authority through statute, regulation, or contract.

Safe State. A situation in which the facility process has been rendered safe and no pressurized material flow occurs in the process lines. Any active, energy generating, process reactions are in controlled or pas-sive equipment. The structures, systems, and com-ponents necessary to reach and maintain this condi-tion are functioning in a stable manner, with all proc-ess parameters within normal safe state ranges.

Service. The performance of work, such as design, construction, fabrication, inspection, nondestructive examination/testing, environmental qualification, equipment qualification, repair, installation, or the like.

Standards. The expressed expectation for the perform-ance of work.

Worker. Worker means an individual within the con-trolled area of the facility performing work for or in conjunction with the Contractor or utilizing Contrac-tor facilities.

APPENDIX A. ADDENDUM TO CRITE-RION 6, DESIGN The following is an addendum to Criterion 6, Design.

This appendix is.a duplication of Section 4.2, "Design, Construction, and Pre-Operational Testing" of the DOE document titled, Top-Level Radiological, Nuclear, and Process Safety Standards and Principles for TWRS Privatization Contractors, DOFJRL 0006; Revision 0. Because conformance to DOFJRL-96-0006 is required, this Section will be used by the Reviewers to evaluate the Contractor's Quality As-surance Program plan of the TWRS Privatization Program.

4.2 Design. Construction. and Pre-Operational

~

4.2.1

~

4.2.1.1 Safety Design The facility should be designed for a set of events such as: normal operation, including anticipated op-erational occurrences, maintenance, and testing; exter-nal events; and postulated accidents.

4.2.1.2 Risk Assessment Acceptable risk analyses should be applied during the design to delineate provisions for the prevention and mitigation, including emergency preparedness and re-sponse, of otherwise risk-dominant events.

4.2.1.3 Safety Analysis A safety analysis should be carried out as required to evaluate the safety performance of the design and iden-tify requirements for operations.

4.2.2 Proven Engineering Practices/Margins 4.2.2.1 Proven Engineering Practices Safety technologies incorporated into the facility re-sign should have been proven by experience or testing and should be reflected in approved codes and stan-dards. Significant new design features should be in-troduced only after thorough research and model or prototype testing at the component, system, or facil-ity level, as appropriate.

4.2.2.2 Common-Mode/Common-Cause Failure Design provisions should be included to limit the loss of safety functions due to damage to several structures, systems, or components important to safety resulting from a common-cause or common-mode failure.

4.2.2.3 Safety System Design and Qualification Structures, systems, and components important to safety should be designed and qualified to function as intended in the environments associated with the events for which they are intended to respond. The ef-fects of aging on normal and abnormal functioning should be considered in design and qualification.

4.2.2.4 Codes and Standards Codes and standards for vessels and piping should be supplemented by additional measures (such as ero-sion/corrosion programs and piping in-service inspec-tions) to mitigate conditions arising that could lead to an unacceptable release of radioactivity during the op-erational life of the facility.

4.2.2.5 Criticality The facility should be designed and operated in a manner that prevents nuclear criticality.

4.2.3 Radiation Protection 4.2.3.1 Radiation Protection Practices Page 16 of 18 Rev 0, 10-25-96 RlJREG-96-01

An acceptable system of radiation protection practices should be followed in the design, construction, aoo pre-operational testing phases of the facility for the protection of workers and the public.

4.2.3.2 Radiation Protection Features At the design stage, radiation protection features should be incorporated to protect workers from radia-tion exposure and to keep emissions of radioactive ef-fluents ALARA and within prescribed limits.

4.2.3.3 Deactivation, Decontamination, and De-commissioning Design The design of the facility should incorporate provi-sions to facilitate deactivation and the final decom-missioning. The objective of these provisions should be to reduce radiation exposures to Hanford Site per-sonnel and the public both during and following dea::-

tivation and decommissioning activities and to mini-mize the quantity of radioactive waste generated dur-ing deactivation, decontamination and decommission-ing.

4.2.3.4 Deactivation Plan There should be an approved plan for deactivation of the facility before it is constructed.

4.2.4 Emer~ency Preparedness 4.2.4.1 Support Facilities The facility design should provide additional capabil-ity to place and maintain the facility in a safe state following an accident if the normal control areas are expected to become uninhabitable.

4.2.5 Inherent/Passive Safety Characteristics 4.2.5.1 Safety Margin Enhancement Design features that enhance the margins of safety through simplified, inherent, passive, or other highly reliable means to accomplish safety functions should be employed to the maximum extent practical.

4.2.6 Human Factors 4.2.6.1 Human Error The possibility of human error in facility operations should be taken into account in the design by facili-tating correct decisions by operators and inhibiting wrong decisions and by providing means for detecting and correcting or compensating for error.

Initial Quality Assurance Program Review Guidance 4.2.6.2 Instrumentation and Control Design Sufficient. instrumentation and control capability should be provided so that under normal operating and postulated accident conditions the operators can diag-nose facility conditions, place and maintain the facil-ity in a safe state, and mitigate accidents. If neces-sary, measures should be provided to protect the op-erator in the performance of these functions.

4.2.6.3 Safety Status Parameters to be monitored in the control room should be selected and their displays should be ar-ranged to ensure that operators have clear and unam-biguous indications of the status of facility conditions important to safety, especially for the purpose of identifying and diagnosing the actuation and operation of a system or components important to safety.

4.2. 7 Reliability, Availability, Maintainability, and Inspectability <RAMU 4.2. 7.1 Reliability Reliability targets should be assigned to structures, systems, and components or functions important to safety. The targets should be consistent with the roles of the structures, systems, and components or functions in different accident conditions. Provision should be made for appropriate testing and inspection of structures, systems, and components for which re-liability targets have been set.

4.2. 7.2 Availability, Maintainability, and Inspec-tability Structures, systems and components important to safety should be designated, designed and constructed for appropriate inspection, testing,

  • and maintenance throughout their operating lives to verify their con-tinued acceptability for service with an adequate safety margin.

4.2.8 Pre-Operational Testing 4.2.8.1 Testing Program A pre-operational testing program should be estab-lished and followed to demonstrate that the entire fa-cility, especially items important to safety, have been constructed and function according to the design in-tent, and to ensure that weaknesses are detected and corrected.

4.2.8.2 Operational Systems and Functional Testing Procedures Validation RIJREG-96-01 Rev 0, 10-25-96 Page 17 of 18

Initial Quality Assurance Program Review Guidance Procedures for normal facility and systems operation and for functional tests to be performed during the op-erating phase should be validated as part of the pre-operational testing program.

4.2.8.3 Safety Systems Data During pre-operational testing, detailed diagnostic data should be collected on systems and components im-portant to safety and the initial operating parameters of the systems and components should be recorded.

4.2.8.4 Design Operating Characteristics During the pre-operational testing program, the as-built operating characteristics of process systems, aIXl systems and components important to safety should be determined and documented.

Operating points should be adjusted to conform to values in the design basis.

Training procedures and limiting conditions for operation should be modified to accurately reflect the operating characteristics of the systems and com-ponents as built.

Page 18 of 18 Rev 0, 10-25-96 RLIREG-96-01