Attached April, 1975, Operating Status Reports for Turkey Point, Unit Nos. 3 & 4
ML18227A389
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/05/1975
From: Schmidt A
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML18227A389 (13)


Text

HObTIILY REPORTS (FOR GRAY BOOI'REPARATION)

NBC BIBUTION FOR PART 50 DOCKE'TERIAL (TEMPORARY FORM)

CONTROL NO:

FILE 'IIOIITHLY'REPORT FIL" FROM. Florida Power

& Light Co.

Miami, Fla DATE OF DOC DATE REC'D LTR TWX RPT OTHER TO:

Office of Management Info CLASS UNCLASS PROPINFO xxxxx ORIG

~l-signed INPUT CC OTHER NO CYS REC'D 1'ENT AEC PDR xxxxxx SENT LOCAL PDR xxxx DOCKET NQ'0-250 an 251 DESCR IPTION:

Ltr trans the following:

PLANT NAME:',Turkey Point 83 and 4

ENCLOSURES:

Monthly Repor t for A ri 1 1975 Plant:

& COHlpolient Operability & Availability

.This Report to be used in preparing Gray Book by Plans

& Operations.

NJHBER OF CO/IES REC'D:

FOR ACTION/INFORMATION JGB BUTLER (L)

W/ Copies CLARK (L)

W/ Copies gy a

~

I W/ Copies KNIEL (L)

W/ Copies SCHWENCER (L)

W/ Copies STOLZ (L)

W/ Copies

'll/i>P 0 I I A I ~

~ aw4

~

~ a W/ Copies PURPLE (L)

W/ Copies ZlEMANN (L)

W/ Copies DICKER (E)

W/ Copies va<<ri swed i sr>

1>ol ~ Mi ~

~ Mtt ) ~

W/ Copies YOUNGBLOOD W/ Copies REGAN (E)

W Copies AR (L)

W/ )Copies no~

e Vs W/ Copies (E)~~~y~

W//Copies B GFI OGC, ROOM P-506A GOSSI CK/STAFF CASE G IAMBUSSO BOYD MOORE (L)

DEYOUNG (L)

SKOVHOLT (L)

GOLLF.R (L} (Ltr)

P. COLLINS DENISE BFG OPR FILE 8: REGION (2)

T.B. WILSON STEFLE TECH BFVIEW SCHROEDEB MACCARY.

KNIGHT PAWLICKI SHAO STLLLO HOUSTON NOVAI<

ROSS IPPOLITO TEDESCO LONG LAINAS BENAROYA VOLLMER INTERNALDISTRIBUTION DENTON LIC ASST GRIMES R. DIGGS (L)

GAMMILL H. G EABIN (L)

KASTNER E. GQULBOURNE (L)

BALLARD P. KREUTZER (E)

SPANGLER

~

J. LEE (L),

M. MAIGRET (L)

ENVIBO

'. BEFD(E} '

MULLER'. SERVICE (L)

DICKER S. Sl IFPPARD (L)

KNIGHTON M. SLATER (E)

YOUNGBLOOD H. SMITH (L)

BEGAN S. TEETS (L)

PROJECT LDR G. WILLIAMS(E)

V ILSON (L)

HARLESS

. INGRAM (L)

EXTERNAL DISTRIBUTION A/T IND.

BRAITMAN SALTZMAN ME LTZ PI.ANS

~MCDONALD CHAPMiAN DUBE (Ltr)

E. COUPE PETERSON HAR C FIELD (2}

KLECKER E ISENHUT WIGGINTON 1 'I QCAL PDB Homestead, Fla

'~1 1 IC (ABERNATHY)

(1)(2)(10) NATIONALLABS 1 NSIC (BUCHANAN) 1 W. PENNINGTON, Rm F-201 GT 1 ASLB 1

CONSULTANTS 1 Nnvton Andersoii NEWMiAB I</8LUME/AGBA BI AN ACBS HOLDING/SENT 1 P D B-SAN/LA/NY 1 BBQQKHAVENNA C LAB 1 G. ULBII<SON, QBi~! L 1 AGMED (RUTH GUSSfvlAN)

Rm 8-127 GT 1 J. D. RUNKLES, Bm E-201 GT

. be 3100 MIAMI,FLORIDA 3310)

LZ FLORIDA POWER 8( LIGHT COMPANY May 5, 1975 0ffice of Management Xnformation and Program Controls U.

S. Nuclear Regulatory Commission Nashington, D.

C.

20555 Gentlemen:

Attached are the April, l975 Operating Status Reports for Turkey Point Unit Nos.

3 and 4; Very truly yours, J8A--

Vice President Power Resources VTC/mjs Attachments cc:

Mr. Norman C. Moseley Jack R.

Newman, Esquire

I iIud* WW tnwte<> rLVwaun vs <Vs ql

,:~

3f;: '" IPl

~'-~-~L~

FLORIDA POiVGR 5 LIGHT COMPANY May 5, 1975 I

F'ffice of Management Information

. and Program Controls U. S. Nuclear Regulatory Commission washington,.

D.

C.

20555

~ '\\ ~

Gentlemen:

Attached are the April, 1975 Point Unit Nos.

3 and 4.

Very truly yours, Operating Status Reports for Turkey

/

~

~

Jg.

D.

S chmidt Vice President Power Resources VTC/mjs Attachments cc:

Mr. Norman C. Moseley Jack R.

Newman, Esquire

~

N

~ t t

.R.

S P

" -l'"" ".'Hat.PING.8LIILO FLORIOA

l 4r g-.1,'e>

I'

~

~

ENCLOSURE A DOCKET NO.

50-250 UN1T NAML'URKEY POINT UNIT NO.

3 May 5, 1975 COihlPLETED BY V-T. CHILSON TELEPlJO'K NO 445-6211 EXT. 2177 DAILY MiIT POtVER OUTPUT

~jr' APRIL, '1975 DAY.

~

A%%IQGR DAILY.l~SVe-net DAY AVEBA% DAILY MVe-net 2.

~

4

. 6 7

10 12 13 1a

'641..

676 676 683 684 690 681 683 681

, 680 637

'473 671 676 20.

21 22

23. '.

24 25 0 26 27 28 29 30

'1 671 660 652 554 569 678

~ 673 671

-"- 671 668 17 18 19 645 557 669 672 672 NOTE:

Daily average power level greater than 666 l1Ãe, due to cooler condenser cool'-

water.

,0 I

)Q g

p -~4.

4 fg 8

K

"~

DOCKET N0.50-250 IJ)flT hAhfE 'EY POINT UNIT NO.

3 MAY 5g 1975 Cuff)LLTED BY V. T. CHILSON TELEI'JJONE

)309 445 - 6211 - Ext.

T MONTH APRIL 1975 OPERATING STATUS 1.

REPORTING. PERIOD: 0001, 75, 04, 01 THROUGH 2400, 75, 04, 30 GROSS fKXJRS Ifif REPOKf'fii(i PERIOD:

720: 00 2.

CURRENTLY AffffJORIZED PCi'ER LEVEL PiNt) 2200 hfAX. DEPEND.

CAPACITY (iWfc JfET) 3.

PO)fER LEVEL TO bHICH RESTRICTED {IF ANY): (MYc NET) None 4.

REASONS FOR RESTRICI'IONS (IF ANY):

'IHIS CRJULATIVE hfiVIH YR-'lQ-DATE TO DATE 5.

MMER OF fKXJRS %K REACIQR 1NS CRITICAL

~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~

6.

REACIQR RESERVE SHUTDOflN HOURS........

720.0 2 751.4 16 779.1

)DiL) G)))HLA)0R gq L))P'01.2 2

7)7,8 16 136.1 8.~

UNIT RESERVE SflffIDO)Ãi HOURS........... 85.0 9.

GROSS 'IHERhfAL ELVRGY GBJERATED(MGQ....

1 457 721 5 698 194 28 378 218 10.

GROSS ELECIRICAL PORGY GENERATED (hnllH) ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ t ~ ~ ~

~

447 437 1 838 226 9 266 031 Ef,FPPPI(PL ~)):RGv ~rnPTE)J

{LILT@

453 965 1 777 175 8 758 340 12.

REACIQR AVAILABILITYFACIQR +1.........

- 100. 0

95. 6
79. 6 13.

14.

UNIT AVAIIABILITYFACIQR g2............

UNIT CAPACITY FACIQR J3................

97.4 94.7 94.4 92.7

76. 6 63.8 15.

16.

UNIT FORCED OfffAGE RATE J4..........:..

SHfflIXXfNS SCHEDULED OVER NEXT 6 hfOVIHS (TYPE, DATE AND DURATION OF EACH):

June 21 - 26, 1975 -'eismic Restraint Inspecf:ion Oct.

20 - Nov. 30, 1975 - Refueling, Maintenance, and Inspections.

17.

IF SKfflJ OfiJN AT DJD OF REPORT PERIOD, ESTihfATED DATE OF STARIUP:

REACIQR AVAILABILITYFACIE fKXJRS REACIQR YAS CRITIC X 100

'I i

Rl'i' J2 UNIT AVAILABILITYFACIQR f~ WXXMTOR ON LI~~Z X 100

~ GR HOU N

fEfiO T ERIOD g3 UNIT CAPACITY FACIQR )) ~ ELE~aI~ M~~T'R GEE &TED X 10 0

)~.

))L'I+i L)LUILB Ai. 1

)L HOURS IN REPORT PERIOD FORCED Offl'A(7). JIOURS X 100

~4 UNIT OUTAGE RATE 1M'LXEfnf R 0 FORCED OLffAGE fKXJRS

T

~ s

'pi~> Y.-Unit No.

3 operation was satisfactory for month except for steam generator feedwater control valve problem on April 23, 1975.

and condenser tube repair'n April 24-25, 1975.

PREPARED BY V. T. CHILSON TELEPIKtlIE EAT.

DOCKET NO. 50-250 UVIT NAhin TURKEY POINT UNIT NO.

3 DATE hIAV 5, 1975 REPORT. hQVIH APRIL, 1975 UNIT SHUTDOUNS/REDUCTIONS 12 75 04 11 13 75 04 15 14 75 04 23 F-KRCED S-SCHEDtILED ll S

DURATION rIOURS

.<<0 18.8 REASON "

B M:"IHOD OF SHUITING DOl~N TiiE REACIQR N/A N/A N/A CG)fK%IS Lead on the unit was reduced to perform perodic test on turbine main steam stop and control valves, reheat intercept, and reheat stop valves.

(Non-nuclear System)

Load on the unit was reduced to clean steam generator feedwater pump Nos.

3A and 3B suction strainers.

(Non-nuclear System)

Uniit was.removed from service to repair steam generator feedwater control valve Nos.

3A, 3B, and 3C valve operator (Non-nuclear Sy stem) 15 75 04 24

<<p<<

B N/A Load on the unit was maintained below approximately 50% R.P. to epair condenser tube leak.

(Non-nuclear System)

REASON:

A-EQUIPiiNI'AILURE(EXPLADI)

'B-h(AIiVI'. OR TEST C-REFUELING D-REGULATORY RESIRICI'ION E-OPERATOR TiAININGAM)

LICENSE EMIINATIOV F-AD~IINISIRATIVE G-OPERATION'. ERROR H-OIHER (EXPLAIN)

~:** h(EIIIOD:

1-hBiXUAL 2-i.<VJAL SCRuI 5 AUIChjQIC SCRuI

4

~ ~

~l

".'ENCI.OSUI(E A v v

--..-"--.'-.-.;,~.
. -::,-.-DOCKI!T NO.

UNIT N1@JE 50-251 TURKEY POXNT ONXT NO.

4 II E

(D~IPLE1TD BY TELEPIIONE NO.

V. T.

CHXLSON 305 445 6211 DATE MAY 5, 1975 DAILY WiIT POLI'ER OUTPUT

>G+PI APRXL, 1975

\\

~

~

AVEIN(T: DAIJ.Y hS('e-net DAY AVEBA(Z DAILYNl'e-net 3

4 6

=9

-10 12 20.

. 21 22 23r

~ 24 25'6.

27 28

-29.

30 31 P

I

~

~

~

17 18

~

~

~

~

~

DOCRET NO. 50-251

,IIIIJIT NA~JE TURKEY POINT UNIT NO.

4 XLATE 5,

1975

-(OhJPLLBTED BY V. T.

CHILSON TELEPJJONE 305 445-681 Ext.

OPERATING STATUS

--1 REPORTING PERIOD ~ 0001 75 04 01

'QJROUGJ J 2400

~

75 3 GROSS HOURS IN REPOR1IIQ PERIOD:

720.0 2.

CUISEN1'LY AtJHJOIE ZED FOIE LEVEL (M<t) 2200 hJAX. DEPE'Q.

CAPACITY (hflfc hET) 3.

POllKR LEVEL TO WHICH RESTRICIED (IF ANY): (hfii'c NET)

REARNS FOR RESIRICTIMS (IF ANY):

04, 30 5.

6.

70

'IIHS hDVH YR-TO-DATE NESER OF HOURS %K REACIQR 1QS CRITICAL. '

035. 7 REACIQR RESERVE SHlJIIXXQ HOURS........ ~

97.3 BOIIRS GBIERATOR CT LILB...............

0-3 033. 3 QMIATIVE

'JQ DATE 11 369.5

97. 3.

11 071. 1 UNIT RESERVE SEIIUOIIN RRIRS........... 9.

10.

CROSS 77IEISSIL F'IERCY GBIERRTEUOSGI)...'.

~ 4 305 374 GROSS ELECTRICAL ENERGY GEJZRATED (NS).

~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

22 657 584

~ 4 7 169 639 12.

REACIQR AVA>LABILITYFACIQR Ql......... 70.7 h~ B:TT:CTRI4~ ax@~ ~RwqA~rJ (Rg)H)

-1 230 1 325 639 6 794 755

78. 8 13.

14.

15.

UNIT AVAIIABILITYFACTOR J2............

'.UNIT CAPACITY FACIQR J3 ~...............

UNIT FORCED OUTAGE RATE J4

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 69.9 69.1 76.8

72. 3 4.8 16.

SJJUTDOi'I'NS SCHEDULED OVER NEXT 6 hJONIHS (TYPE, DATE AhJD DURATION OF EACJJ):

Mar; 30 - June 1,

1975 - Refueling, Maintenance, anci Inspections.

Oct.

13 Oct. 18, 1975 - Seismic Restraint Inspection.

17 ~

IF SJIJE011N AT M) OF REPORT PERIOD, ESTlhJATED DATE OF STARTUP: June',

1975 REACIQR AVAILABILITYFACIQR R'~~)~~ggg HOURS RFACIQR ieS CRITIC% X 100

'OURS GBiTRATOR ON LIKE X 100 J2 UNIT AVAILABILITYFACIQR G

J OJ RE'T~~g~r UNIT CAPACITY FACIQR NH ELECTRICAL POt>ER GENERATE) X 100 IKXJRS IN REPORT PERIOD FORCED OtJJ'A(II JiOURS X 100 0

FORCED OUPAGE JKXJRS

SQivARY: UNIT NO.

4 WAS OUT OF SERVICE ENTIRE MiOiNTH FOR REFUELING, MAINTENANCE, AND INSPECTIONS V OCKET NO.

50-251 TURKEY POINT UNIT NO.

4 MAY 5, 1975 PREPAREl) BY V. T. CHILSON TELEPHONE 3

5 445 621 Ext.

2177 REPORT hOVnr APRIL. >>75 UNIT SHUTDOifNS/REDUCTIONS NO.

05 5 03 29 b

F-FORCED S-SCHEDULED DURATION URS 720 ~ 0 REASON "

C FLHOD OF SHUTTING DOiIN

'GB REACIOR "*

COME Unit No.

4 was removed from service

{deliberate manual shutdown) for refueling, maintenance, and inspectiqns.

{Nuclear and Non-nuclear Systems)

I I-I' I ~

~iI

~

s v

~

REASON

'-EQJI Fi ILVI'AILURE(EXPLAIN/

~

B-h!AIIVI'. OR lEST C-REFUL'LING D-REGULATORY RESTRICTION E-OPERATOR TRAINING M)

'ICENSE EX&/INATION F-AININISTRATIVE G-OPERATIONAL ERROR H-OIHER (BPLABQ hKIIiOD:

1-i%%AL 2-hi%MAL SCRA~1