NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION MATERIALS LICENSE PAGE 1 OF 4 PAGES Amendment No. 1 Pursuant to the Atomic Energy Act of 1954 , as amended , the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations , Chapter I , Parts 30 , 31 , 32, 33 , 34 , 35 , 36 , 37 , 39, 40 , 70 and 71, and in reliance on statements and representations heretofore made by the licensee , a license is hereby issued authorizing the licensee to receive , acquire , possess, and transfer byproduct , source, and special nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954 , as amended , and is subject to all applicable rules , regulations , and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below. Licensee 1. AAA Paving and Sealing , Inc. 2. P.O. Box 975 Princeton , WV 24740 6. Byproduct, source , and/or special nuclear material A. Cesium-137 B. Americium-241/

Beryllium

7. A. B. In accordance with letter dated June 12, 2018, 4. Expiration Date: April 30 , 2027 '" I~ -I ~k -5. Docket No.: 030-39028
3. License number: 47-35408-01 is Reference No.: amended in its entirety to read as follows: Chemical and/or physical form 8. Maximum amount that licensee 9. Authorized use may possess at any one time under this license ---Sealed Sources (AEA A. 9 millicuries per source A. For use in Troxler Electronic Technology/QSA, Inc., Model ... : and 18 millicuries total .. Laboratories Models 3400 Series and CDCW556; Isotope Product I I ,. 4640-B portable gauging devices for L *. Laboratories , Model HEG-137) '.E ~, measuring physical properties of materials. Sealed Neutron Sou~ce (AEA B. 44 millicuries per source 8. For use in Troxler Electronic Technology/QSA, Inc/Model and 44 millicuries total Laboratories Model 3400 Series AMNV.997; Isotope Product portable gauging devices for measuring Laboratories, Model Am1 .N02, physical properties of materials. 3021 , and 3027) CONDITIONS
10. Licensed material may be used or stored at the licensee's facilities located at 560 Turnpike Industrial Park Road , Princeton, West Virginia.

Licensed material may be used at temporary job sites anywhere in the United States where the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulating the use of licensed material, including areas of exclusive Federal jurisdiction within Agreement States.

NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 47-35408-01 Amendment No. 1 Docket or Reference Number 030-39028 P AGE 2 OF 4 PAGES If the jurisdict i on status of a Federal facility within an Agreement State is unknown , the licensee should contact the Federal agency .,. controlling the job site in question to determine whether the proposed job site is an area of exclusive Federal jurisdiction.

Authorization for ... use of radioactive materials at job sites in Agreement States not under exclusive Federal jurisdiction shall be obtained from the appropriate state regulatory agency. 11. Licensed material shall only be used by, or under the supervision and in the physical presence of , individuals who have received the training described in the application dated January 31 , 2017. The licensee shall maintain records of individuals designated as users for 3 years following the last use of licensed material by the individual.

12. The Radiation Safety Officer (RSO) for.this license is Brandon Henkes. 13. Sealed sources or source rods containing licensed material shall not be opened or sources-removed from source holders or detached from source rods by the licensee, except as sp~cifically authorized.
14. A. Sealed sources and detector cells shall oe)ested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of registration issued by the t(s. Nuclear Regulatory Commission under 10 CFR 32.210 o r by an Agreement State. In the ' I ,,. absence of a registration certificate, sealed sources shall be tested for leakage and/or contamination at intervals not to exceed 6 months , or at such other intervals as specified.

B. In the absence of a certificate from a transferor indicating that a leak test has been made within the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State , prior to the transfer , a sealed source received from another person shall not be put into use until tested and the test results received.

C. Sealed sources need not be tested if they are in storage and are not being used. However, when they are removed from storage for use or transferred to another person, and have not been tested within the required leak test interval , they shall be tested before use or transfer.

No sealed source shall be stored for a period of more than 10 years without being tested for leakage and/or contamination.

NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 47-35408-01 Amendment No. 1 Docket or Reference Number 030-39028 PAGE 3 OF 4 PAGES D. The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be filed with the U.S. Nuclear Regulatory Commission

)n accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated, repaired, or disposed of in accordance with Commission regulations.

E. Analysis of leak test samples and/or co~~amination shall be performed by persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.

The licensee is authorized to collect leak test samples but not perform the analysis. F. Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 years. 15. Each portable nuclear gauge shall have a lock or outer locked container designed to prevent u nauthorized or accidental removal of the sealed source from its shielded position.

The gaug~ or its container must be locked when in transport or storage, or when not under the direct surveillance of an authorized user. 16. The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory Commission , to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be maintained for 3 years from the date of each inventory, and shall 1~6fude the radionuclides, quantities, manufacturer's name and model numbers, and the date of the inventory. 17. Any cleaning, maintenance, or repair of the gauge that requires detaching the source or source rod from the gauge shall be performed only by the manufacturer or by other persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.

NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 4 OF 4 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 47-35408-01 Amendment No. 1 Docket or Reference Number 030-39028

18. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations , and procedures contained in the documents, including any enclosures , listed below. This license condition applies only to those procedures that are required to be submitted in accordance with the.regulations.

The U.S. Nuclear Regulatory Commission's regulations shall govern unless the statements , represent a tions , and procedures in the licensee's application and correspondence are more restrictive than the regulations.

A. Application dated January 31 , 2017 (ML 17055A521)

Date: July 9, 2018 FOR 2S. NUCLEAR REGULATORY COMMISSION By ,flµ)_!_/ Leonardo Wardrobe Region 1