NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION MATERIALS LICENSE PAGE 1 OF 4 PAGES Amendment No. 11 Pursuant to the Atomic Energy Act of 1954 , as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10 , Code of Federal Regulations , Chapte r I , Parts 30 , 31, 32 , 33 , 34, 35 , 36, 37 , 39 , 40, 70 and 71 , and in reliance on statements and representations heretofore made by the l i censee, a license is hereby issued authorizing the licensee to receive , acquire, possess , and transfer byproduct, source , and special nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). Th i s license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules , regulations , and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any cond i tions specified below. Licensee 1. ECS Mid-Atlantic , LLC 2. 1340 Charwood Road, Suite A Hanover , MD 21076 ~* (t? In accordance with the lette r 4. Exp i ration Date: August 31, 2027 dated April 26., , 2018, { t-----------.,..;
~;;:...._--1
- 5. Docket No.: 030-37505 Reference No.: 3. License number: 19-31261: 0 f'T s amended in its entirety to read':a s follows: 6. Byproduct, source , 7. Chemical affa/or physical form *~ '\ 8. Maximum amount that lice , hsee 9. Authorized use and/or special nuclear -( , may possess at any one time material * '-"' \ .,~ *~under this license -I~_.:, *, :::::::., A. Cesium-137 A. Sealed S o u r ce s (AEA"-. r'--l r A. 9 millicuries per source..::.,,. A. For use i n Troxler Electronic Technology/QSA Global Inc., anci208 millicuries total~ Laboratories Model 3400 Series , Model CDCVV556; Isoto p e""' ~-\j; [LJ' . . :"' 4640, and 4640-B portable gauging Products LabQr~tories;'M b del :r-,. ,/:;, '{/, *, * *-,"";v:1 C:,J devices for measuring physical HEG-137) / ( ' '* * ' , ' ... properties of mater i als. . / B. Amencium-241 B. Sealed Neutron Sourae (AEA 1 8 1 J 44 millicuries per.source B. For use in Troxler Electronic Technologies/QSA Gid~I Inc., and 880 milli cu ries total Laboratories Model 3400 Series Model AMNV.997; lsot d'pe -.11 "'" ' portable gauging devices for measuring Products Laboratories, Mod~I '(_7 ~-:"7 < ""lr physical properties of materials.
Am1 .N02 , 3021 , and 3027) CONDITIONS
- 10. Licensed material may be used at temporary job sites anywhere in the United States where the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulating the use of licensed material, including areas of exclusive Federal jurisdiction within Agreement States.
NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 19-31261-01 Amendment No. 11 Docket or Reference Number 030-37505 PAGE 2 OF 4 PAGES If the jurisdiction status of a Federal facility within an Agreement State is unknown, the licensee should contact the Federal agency controlling the job site in question to determine whether the proposed job site is an area of exclusive Federal jurisdiction. Authorization for use of radioactive materials at job sites in Agreement States'rf ot u naer; exclusive Federal jurisdiction shall be obtained from the appropriate
_; . state regulatory agency. 11. Licensed material shall only be used by, or un~er the supervision and in the physical pJ: esence of , individuals who have received the training described in the letter dated July 24, 2017. 'T he licensee shall maintain records of indivi du als designated as users for 3 years following the last use of licensed material by the individ l ral.
- 12. The Radiation Safety Officer (RSO) for tm:S license is Christophe r;A~eller. () 13. A. Sealed sources shall be tested for leakage and/or contamination at intervals not to exceea the intervals specified in the certificate of registration issued by the U.S. Nuc re'a} Regula J ory Commission under 10 CFR 32.210 ~y an Agreement State. In the absence of a registration certificate , sealed sources-shalLbe
- t~sted for1eakage and/or contamination
-at intervals not to exceed 6 months, or at such other intervals as specified.
B. In the absence of a certificate from a trans f e r or indicating tnat l a'leak test has bee Q.., m ade within the intervals specified in the certificate of registration issued by the U.S. Nuclear Reg u latory Commission under 1 O CF~2.21 O or by an Agreement State, prior to the transfer, a sealed source received from another person s ll'all not t be put into use uo!il'i tested and the test results received.
-.. ',.._ C. Sealed sources need not be tested if they contain only hydrogen-3; or they contain only a radioactive gas; or the half-life of the isotope is 30 days or less; or they contain not more than 100 microcuries of beta-and/or gamma-emitting material or not more than 10 microcuries of alpha-emitting material.
D. The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be filed with the U.S. Nuclear Regulatory Commission in accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated , repaired, or disposed of in accordance with Comm i ssion regulations.
- -" NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION PAGE 3 OF 4 PAGES License Number Docket or Reference Number 19-31261-01 030-37505 Amendment No. 11 E. Tests for leakage and/or contamination, including leak test sample collection and analysis, shall be performed by the licensee or other persons specifically licensed by the U.S. Nuclear Rel ito ry Comm iss ion , or an Agreement State to perform such services.
F. Records of leak test results shall be kept in"'u n its of becquerels (microcuries) and s hall be maintained for 3 years. 14. Sealed sources or source rods containing j icensed material shall not be opened or sources removed from source holders or detached from source rods by the licensee, except as ~pe i ifically authorized.
_ 15. The licensee shall conduct a physical inventory every 6 months, , br at , other intervals approved by the U.S. Nuclear Regulatory Commission, .... ..__ to account for all sealed sources and/o i:,_, devices received and possessed L under the license.~cords of inventories shall be maintained for 3 years from the date of each inventory, and shall in_clude the radionuclides, quantities, manufacturer's name and model numbers, and the date of the inventory.
- 16. Each portable nuclear gauge shall have a*lock or outer locked .cbntainer designed to pre y ent unauthorized or accidental removal of the sealed source from its shielded position.
Ttie.,...gauge or its container v nust be locked ~h-en" in transport or storage, or when not under the i. .-I r direct surveillance of an authorized user. 17. Any cleaning, maintenance, or repair of the gauge(s) th~r requires detaching 1 the source or source rod from the gauge shall be performed only by the manufacturer or by other persons specifically licensed/by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.
NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 4 OF 4 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 19-31261-01 Amendment No. 11 Docket or Reference Number 030-37505
- 18. Except as specifically provided otherwise in this license, the licensee ,.shall conduct its program in accordance with the statements, representations, and procedures contained in the document s'; including any*enclosures, listed below. This license condition applies only to those procedures that are required to be submitted in accordance with the regulations.
The U.S. Nuclear Regulatory Commission's regulations shall govern unless the statements
,..representations, and procedures in the licensee's application and correspondence are more restrictive than the regulations.
A. Letter dated July 24, 2017 (ML 17207A156)
Date: June 25, 2018 " <r FOR THE U.S. NUCLEAR REGULATORY COMMISSION By:
Dennis Lawyer Region 1