ML18194A146

From kanterella
Jump to navigation Jump to search
Log of Boring PV-20
ML18194A146
Person / Time
Site: Palo Verde  
Issue date: 07/13/2018
From:
Arizona Public Service Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML18194A146 (1)


Text

NATURAL GAMMA LOG INCREASING RADIATION~

BASIC SOIL PROPERTI ES LITHOLOGIC DATA PALEO-CARBONATE MAGNETIC DESCRIPTIONS UNITS L CONTENT POLARITY COUNTS PER SECOND 170 190 210 90 110 130 150 Pl 2

RP 47 100 I/0 0

2

~ A 120 ELEV-96/'

SILTY SAPID,(SAI),b own,m diam

dense, enploehc, loose//reg enr grovel hsrtbons I mx cocoons SILTY CLAV (CL) red brown, ve y Still, d y.

cLAVEvse r wire SAND,(IHL),

brow T v'hil,mo el, I co ous.

0+

IB PoslTlvE e---

sicrv cLAY,/cc-ce), wire DCCASICHAL CLAYEYSILT/ bro to gr ~ -brown medium fob gh PATSHC/ty. very'hff IO hard, skghtly motsti occostonol sandy hot'leans.

e SS e

TS 9

BB

~ Bl

~RS

~IOG IIT 9

iBT

CLAVEYSAPID AND SANDY CLAY/

(SC-CL),brown,re y se'ffordenso, slxghfly moxa/, sirotlhedlaccaslo grove/ clasts iSB 69 76 95 100 REARURED WATER LEVEL 90 100 80 95 70 96 48 100 88 100 98 i00 86 100 100 100 96 80 97 100 SAMPLE LOCATION~

DEPTH (FEET)~

cLAvEYcRAvEL wire sAND,(80),

den ee SILTY CLAY,(CL Chi,red-bf own,htixo plashctty,very Self to hard,moxst.

CLAYEY SRAVELI(SC),rod-brownt weathered conglomerate I' Dg q,, 'LII

.vg L

g I-67 OR 10 0

Acm+u(AJ

,Ar 2~PL w

'J 0 4

):'o','v

g,6x

- ~T-.II L

.0 o.

-l )J

'6'i=.~-

J.

J'i('i 0.)

)o a.'~

L,I

'i.nv'j>

ofJ. ~

Ju

OYJ, J.w' Rt J.B FANSLDHIEATATEImolt/cd gr y-brown, hard/ angular, poorly sorted, mtr d volcontc elects tn o sxlty sxvndmafrtci cleats frow yo "tod"w fh rara cobbles t s",

nonbedded, skghey free/'ured poorly Tndurated SILTY SANDSTONE, ltghl I own SILTV SAAIDSTDPIE, hgh t aro tut'fcvaeous.

y SANDSTI7NEI dark brown, hard, sub ng lar, wAHSO ted, non-beddrd. Skilhflytrxxrlu ed SANDY TOFF, /'ght bro to h te, moderate/y bord, aubangular, OH aat ted, nonbedded, non.

fractured, al ghtly wan/he ed

TD-5625'TVFFACEDVS SAAIDSTDNEIb own, hard; occastonal basalt 4 loots.

SYMBOL EXPLANATION ENGINEERING PARAMETERS Pl p los neil y index minus 200 percenl passing 200 sieve W/C percent matc/ore 85 d y densi/f SAMPLE TYPE ASTu D 422 I'H f2/

A S TAI '

422 AsTHI D 424 flsltl AST'At/ ll22/e TI Drive Sample pitchs Tube Sample NII Ccrc,No. /Ddtcefes

% Recovery Slondard Pens/ra/ion Test, "N value 4srn D tees

~ sl CARBONATE CONTENT No Rscctior

+

Si ghny Reacttvc Moderalely Reactive

++ Highly Reocf /vs leases an sample reset/on Io o ID% Hc/

UNITS sole I/on)

Vnils column refers Io generol stroltgrophic Clvtsions Identified wxlhtn Ihe basin sedkmenls PALEOMAGNETIC POLARITY Inclinatton of remnant magnetic vector in general ogreemenl wilh (G) ) or opposition to ((3) the presenl magnetic field.

8bfogneltc veclor indelerminate 4 depfh Poieomagnelic 6'cs Reverso/~

ID scr~ eievxrtion DESCRIPTIONS Lilhologtc sescriphons were compiled from geologists field logs, laDomlory test oslo, snd down-hole geophysics Field logs'ere prepared tn accardonce wilb ASTM D2488-69 Clossificattons based on laboroiory les/ do/o ore in accordance wtth ASTAI D2482-69. Rocs descriptions fol/ow proc'edures ouHined in Ihe QUARTERLY OF THE COLORADO SCHOOL OF MINES, Volume 50, No. I Descr pl ons for rolory Dar'ngs ors Dosed upon cueings

somples, geophysical

/ogs and drHlers'comments LOG OF BORING PV-20