ML18194A133
| ML18194A133 | |
| Person / Time | |
|---|---|
| Site: | Palo Verde (NPF-041, NPF-051, NPF-074) |
| Issue date: | 07/13/2018 |
| From: | Arizona Public Service Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML18194A133 (1) | |
Text
100 120 140 160
/80 200 220 WEESVREC WETER LEVEL NATURAL GAMMA LOG
INCREASING RADIATION~
COUNTS PER SECOND Ee ale 90 100 0
2 UO 120 12 44 ss
~4 21 100 la os n
4 29 ss ls BASIC SOIL PROPERT I E S 20 40 60 100 120 14
ELEV. 214D CRAVELLY 5/LTY SAND AND SANDY SIL Ti (Shl-ML),brawn to gray Drown, nonploetic fs lsw ploetnHy.
loose, dry, c ude/y st HAsd.
CLAYEY SANO VVITH CRAVEL, (SC),
a OH*d D awn, meC/um plaetlvty, msdum d ts,mort/,
5ILTY SANOMSDI-SP), groy.brown,
/ow pi'ant/city.
~ y dma, m n cocsous, rare gravel.
SILTYSTEND AIVD SSHDY CRAVELLY CLA Y I (ML-CL),D~own fo pray, ls to odium plashvfy.
ed um dents, crudely slrohfied.
SILTY SANO AND SANDY SILT WITH CLAY,(5MML),/rown,/onto msd m plastic ty, m curn dtnse I stdf, mast, crudely strahfisd CIAYEY 5/LT AN'D SILTYCLAY; (Lfc-CL CH), brown,low to high plosficlty, vary af f/ to nard, mmsf, crudely atraAAed, micocao e
CLAVEY SANO ANO SANDY CLAY; (Sc-cL), light Drown law to meduni plashr. Iy msd um danae or ef f/
cr defy strahl ed.
6 POSITIVE e NEGATIVE 99 iOS I I 6 IES
/~0'- O 137 146 LITHOLOGIC DATA PALEO-CARSONATE MAGNETIC DESCRIPTIONS UNITS 3 CONTENT POLARITY 17 OE SILTY CLAY WITHSAHD,(CL.CH).
/ighf brown to rsd-bro mac/us/ to h gh ploahcity e
IST 199 200 240 SMTY CLAYARID SANO/
CLAY/
(CI:CH),with scapar d sandy sill and
<<Hy sand horisons, red-bro n,
lo to Agh plashc /y e y stiff to hcird, diimp e
22O
~R8 Tso 24O 260 26I 96 99
+++
++
+i+
CLAYEY SAND WITH ORAVELI(SC),
++
byown. danae.
ANOE5/TE I gray, ha d, holo-cryslapina, v e cuter, very fractumd
TD-30T'6 440 520 SAMPLE LOCATION~
DEPT& (FEET)~
SYM BOL EXPLANATION ENGINEERING PARAMETERS PI plasticity indes minus 200 percent passing 200 sieve W/0 percent moisture Sd dry density SAMPLE TYPE ns/N a ett Iis/2/
4 s TN '
ets ssTIII ante flsTI/
nsrsr/D st/it T/
21 Drive Sample Pitcher Tube Sample Ny Care,ho. /Odioolss onv Recovery Standard Penetration Test, "N"value ASTN D /snit.i/T CARBONATE CONTENT No iaeaclion
+
SliphHy Reactive
@ Elodeialsly I/costive
++ /Aghly Reocti ve (Diissd on sample reaction la o ION HCI UNITS salutioni Vni/s column refers fo penero/
stmfiprophm Ciwsions Idrntified within the basin seC/ments PALEOMAGNETIC POLARITY Incliniitior of remnant mapnelic vecfor in general opreemenl wiln ( II)) or opposirion to ( Q) the present magni'tic field.
8tlagnelic vector inde/erminoisw depth Po/an/i/op/i/IAc IT
/ts'eversol
~ IO etf~ eleva/ion D E 3 0 R I 9T I0 N9 Lithologic descriptions were compiled from peolopisfs field lope, laboratory test dale, and down-hole peophysics Field /ogs were preporedin occordonce with ASTN D2488-69 Classifications Dosed on laboratory lest dont are inaccordance wfh A$TM D248T-69.
AWcs Ceccripfions follow procedures ouHined in Ihe OUARTERLY OF THE COLORADO SCHOOL OF MINES; Vc /vms 50, Ho /
Descriptions for rotary Dodngs ore Dosed upon cultinps
- samples, geophysical lope and dril/ers'comments LOG OF BORING PV-21