90 IIO 130 150
/TO 190 2/0 NATURAL GAMMA LOG
INCREASING RADIATION~
COUNTS PER SECOND Pl
/c 100 0
2 DO 120 BAS I C SO I I PROPERT I E S 0
ELEV1140'i 0+0 8 POSITIVE e NEGATIVE LITHOLOGIC DATA PALEO-CARBONATE MAGNETIC DESCRIPTIONS UNITS L CONTENT POLARITY NEAEUREO aeTEII LEVEL 14
~ 0 I ~
te 14 et eo ee
~
~
~
~
~
~
20 40 IZO l4 a.
SILTV SAND WITH CLAY AEID SRAVELLV 5AAID I I'5M 5P/.
rod-brow,lo to edam pleat city, angular to svbrm <<ded, med um de se,d y, cr de/y stra/Isa/I cob'I/Ies'to 67 Sllft'CLAYWITH 5ZL'Di(CH.CL) bro n
mocha to h gh plash ty, wry shit damp/ scone ea caliche nodules CLAYEV 5ILT-5ILTYCLAY,(MI.'CI).
brawn, low to medium ptosf/fvty, wry sntf otst m co cons slLTY sAIYD, (DM), brown, Iow plashc ly, dense, wet/scattered gro tl.
SAAIDY CLAY WITH Slit, (Cl CN),
bro n,me/bunt plasticity, very shf/
mo tf fo damp; ace/tv vd ca//she nodules/ loco/ Iltn 8 flysand hoi'iso/is SILTY SA/VD ADID SANDY5ILT; (sM.ML), Drown, v ry st I/ e
- dense, nto e/,cr defy Otrohhed.
SILTY CLAYAIVD CLAYEY8/LTI (CL ~ hlL), motHed Iroan, low to m d plvshaty, shtt tv hv d, w I, scs//e ed grave/and co/ca nodulee (j3 47 63 e
ee BS e
100
/0 824 127 io et CLAYEY SAND AND CLAt EV SILT/
(5C.ML)hghf Dn n to gray sn n,
lo Io med m ploshaty, e y dense or hard, m st e
Z4 SllTY CLAYAAID 5/LT WITHCLAYI (CL-CHJ, red-b own, /ow to nigh plashcity, mamt fo damp; sea/fared caiicha nodules, occasional sandy siH hor cans.
CI
/I 224 zos 243 ZSO 00 i4 340 onus 360 CLAYEYSAND ADID SANDY CLAY, (SC-CI.I Oro
<<, nard w'ry dense, moisf, scat/crea cahche natu/est cobbles end aoulde 8 m'54'crudely sfratihad 400 SAAIDV5IL7 AND SILTY 5ANDI (ML Sht) hght Dro~n very shl/ to hard alighHy mast scattered cal che nod /es 100 42 440 OJ odt
).
Ct
).d:)
j g
L in FAIVCLDMERATE, light brown to groy,modera*ly nord to nord, shghfly ca/ca ovs/
npulor Io sub-angu/ar, pow'ly sorted, 0'e fs olcan c ctaste o
atriv of fine silly sand/ upper IDLI5'derately
/herod e90 TD.
4S/AS'00 520 SAMPLE LOCATION~
DEPTH(FEET)
F ENGINEERING PARAMETERS SYM BOL EXPLANATION PALEOMAGNETIC POLARITY Pl piss/ city index minus 200 percen/ passing 200 sieve WIG percen/ moisture SO dry density SAMPLE TYPE Set N D 822 I/DTZ/
SSTN D SZS ssfN '
st'8 fief/I S S TNI D ZZ/it-Tl Drive Sample Pitcher Tube Sompie NK Core,ND. Indicates Recovery Slanda d Penetration Test, "h'"valve ssTN Disso-of CARBONATE CONTENT No If/tact/oil S/ ght/y Reactive fPModerately I/sac/i vs
++ Hiphly Reactive (Dosed on sample reaction lo o ID% HCI UNITS solution/
/In/ts column refers to genera/
slrangraphic divisions idtnlified within the basin sad msnls Inc/not/or of remnant mapn.'tif vector in general ogreemcn/
with ((I)i or Dppositton lo (E) I Ihe present mopnenc
//8/4 8hfognehc vector indetermintifew depth Poleomognefic If
/28 Reverso/~
ID ezfv elevat on D E 9 0 R I9T I0 N9 L tnolopic descriptions were comp Ied /rom geolagisls field logs, laboratory lest dale, and down-hole geophysics Field logs were prepared in accordance with ASTM D2466-69 Classificolions based on loborotory lest dole Drain Deco dance w ih ASThf D246T
~ 69. Roc* descriptions fo/low procedures ouih'ned in Ihe QUARTERLY OF THE COLORADO SCHOOL OF MINES, Volume 50, No I Caser'piions
/ar rotary Darmps are Dosed upon cultinps
- samples, peophysical logs ond drillers'comments LOG OF BORING PV-25