ML18194A115
| ML18194A115 | |
| Person / Time | |
|---|---|
| Site: | Palo Verde (NPF-041, NPF-051, NPF-074) |
| Issue date: | 07/13/2018 |
| From: | Arizona Public Service Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML18194A115 (1) | |
Text
NATURAL GAMMA LOG INCREASING RADIATION~
BAS I C SO I L PROPERT I E S LITHOLOGIC DATA PALEO.
CARBONATE MAGNETIC DESCRIPTIONS UN/TSL CONTENT POLARITY COUNTS PER SECOND ITO
/90 2IO 90 IID l30 l50 Pl 2
go 90 IOO 0
2 60 I20 ELEY"947 0+
e POSITIVE e NEGATIVE NRARVRRD RRTRR LEVEL 20 40 60 80 IOO
/20 0
5ILTV SAND AND SA/VDVGRAIIEL WITH SILT,(~-GP-GAS), bm angular, loose ta med a'ense, dry /0 sightly most, accus wml cloy hor sons
CLAYEY SILT(A/L) kghtb ow,fr to 4
- shff, oat, occos nol gra el
SILTY SAND AND SAA'DY SILT(SA/VS',
n, oi, ss or ve y sh/V, r Nst mzoceous CLAYEYSILT(ML),bro n, shff, must, pr bable pa/sos I w th root otts
slLTv sAIvD AND sAHDY GILTPks/i/L) bro n, dense or ve y shff, o/st strut fsd 2
SILTV SAAID HI/TH GRAVEL,/SAN),
, ong lar; madam dense,
- moat, grow/ pmdo nontly volcan/cs FANGLOMERATE,bro n-gray, moderately horn, onguk r, poo ly sar/mt volconc ondgronn'c ciasts n a suty sa d motrvG orzosmnal obbles QP 33 41 45 50 54 56 63 73 79 l40
GRAhaTIC ROCK, ery weathered,soft/
red potash feldspar, quartz, anna/tered bmt te anb da f, very fractured, fractures I"//ad w th colo h o <<I md cloy, mmk becomes prograst eiy honda with a'es th (grad/a<<wat catlttcl/
26 I"0
/8
GRAA'ODIORITEIhc/ocrystaihn, phoner itz, fine to med m grmnad, sgugro I ri quo tz, fsldspm ond Ivohte ob ndont, sry fi'o tu sd, trmtures frHed w fh cole/te o d rad
/oy TD
-2/0'40 280 00 340 360 380 400 440 4SO 500 520 540 SAMPLE LOCATION~
DEPTH t FEET)~
SYMBOL EXPLANATION ENGINEERING PARAMETERS Pl plasticity Inde<<
minus 200 percent passing 200 sieve W/0 percent mo stu e sc dry density SAMPLE TYPE Dr vs Sample Pitcher Tube Somple Nk'ore, IVumber /ndhcates SC Recovery Standard Penetration Test, N rai e CARBONATE CONTENT No Iteocnon
+
5//ghHy Reach<<a hfoderalely Reactive
++ Highly Reactive
/based on sample reaction Io a ID% HCI UNITS A s/AI D e2k IH Tel ASTA 'DSZS ASTN. D SZS HST/I AS TNI D ZZIS -TI ASTN D/Saa-ai'olution/
PALEOMAGNETIC POLARITY Inc/ nalior of remnant magnrhc vecloi in general ogreemenl with (/
or apposition lo f (3 I the presen/
magnetic field 8
A/agnatic vecloi indeterminate depth Polaomagnelic li'zs Reversal~ ID ezt~ eleval'on DESCRIPTIONS Lllholog c descriphons were compiled from geologists /laid logs, laboratory /ssl daio, ond down-hole geophysics Field logs were prepared m accordance with RSThf D2488-69 Classiticohons based on laboratory hist data are In accordance with ASTH D2487 69 Rock descriptions follow procedures ouHinedin Ihe QUARTERLY OF THE COLORADO SCHOOL OF MINES, Volume 50, IVD I Descnpiions for rotary borings ore kneed upon cuih'ngs
- samples, geophysical logs ond dr/gers'comments I/n/ls coi mn reiers /o gene ol s/roligraphtc d/ws/ons identtfred within Ihe basin sed ments LOG OF BORING PV-4I