ML18194A077

From kanterella
Jump to navigation Jump to search
Log of Boring PV-53
ML18194A077
Person / Time
Site: Palo Verde  
Issue date: 12/13/2018
From:
Arizona Public Service Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML18194A077 (1)


Text

NATURAL GAMMA LOG

INCREASING RADIATION~

BASIC SOIL PROPERTI ES LITHOLOGIC DATA PALEO.

CARBONATE MAGNETIC DESCRIPTIONS UNITS 3 CONTENT POLARITY COUNTS PER SECOND 170

/90 210 90 I I0 130 150 PI 2

/2 42 87 49 99 2

2 ov 33 9

79 99 100 0

2 120 20 40 20 120 14 ELEV 958' SANDY CLAY WITH GRAVEL/(CL),

Ivow, soft, dry/ km/e caliche noeu SILTY SAND; (StVJI brown, angular, medium dense, dist, mtcaccous CLAYEY SILT(ML)brown,NiffmoSt F SILTY CLAY WITH SAND; (CH),

red-brown, htghp/as//city, very stiff, moto/.

SILTY SAND/(SM)hmwrh %%dssc mern!

~ SILTYCLAY;(CRjbrawn, htg)t plast'ictty, very sfo'f, momQ occamonetl cakche nodules, Mn specks and root votda

~CI.AYEV SILT WITH SAND/(ML)

Drovwt sttft" to vct'/ 8t toy nto18t.

SILTYCLAYYCL),brown, very stiff, motsti Mn specks

~CLAYEY SIL7I(ML),brown, very shfft moist; abundant Mn specks.

~SILTY SAND/(SM) brown, dense, moist/ predominantly queer tz.

~CLAYEY SILT AAID 5ILTY CLAY.

(ML-CL)brown, did/, most/

scot/shed cohctm nodules.

~SILTY CLAY/(CI=CH)rud-browne veny shff, moist, micaceous; occasional cohche noddled.

~CLAYEY SILT(ML)brown, vet V ahfl; tern/st.

~SILTY CLAY;(CL-&)brown, ver y shiy, motsO %%dcohzed capche cancan/he

CLAYEY SILTAND SILTY CLAY; (ML-CL)brown, very shff ht hard, motet; clay tncreases wtlh d /Zh SILTY54/ID AND 54/VDVSILT/(SSZVA brown, shff or medium dense, must, SILTY CLAY AAID CLAYEY SILT; (CL-ML)brown, ver y sttff, motet.

5ILTV SAND AND S4/VDY SILT/

(SM-MLJ brown very shll" cv dense mush eirottfted.

iCLAYEVSILT AND SAIIDY SILT; (ML),browne stiff, mrna/i localized thin sand lenses.

~SILTY SAND AND SANDY SILT CSM MLJ brown-blmk mediwn dertoe or attfl,'aist, stratthedl occasional lhn ckty /enma.

0+

e POSITIVE e NEGATIVE BB 106 117

~I25 8

141 151 37 9!t 240 SILTY CLAY (CLMH)red-brown medium

%%d high pfasticrty, very stdi',

mevstt accus%no/ clayey silt hanm/39 28 99 24 97

~SILTY CLAYAND CIAYEY SILT; (CL-ML),red-brown, low /o medium ploshcdy, very shl'f, moot/.

32 9 it 00 340 rSILTY CLAY,(CL-CH),red-bro wnt

/ medium *high plaatimty, very stiff tu hart/, moist/ occastanctl cakche nodules.

~SILTY SAND/(SM),hrot n, dense,must.

SILTY CLAY/(CL-CH), ed-brown, very stiti'o hard, moist; scalfcred calche nodules.

CLAYEY SILT WITH SAND/(4/L) brown, very stiff h hard, moiSt; occosional caitdm noduids wtlh grvzvel.

77 67 79 100 10 0 100 400 440 480 480 800 820 jee3j z.0j

)I..

'S ej

'/1 C, JO

. 23

-j'I j J.

j' je.

II9 Q WO-:

';je 'a

. j133J

~

Ce. '4 Jm

~J.-

.0 JO 2

3'JO Ce FANOLD/HERATEI brown, hard/

angular

%%d subrounded, poorly sorted fmc /o coetrse grove/ clos/8 tn a siyty sond matrix; andeute, bc salt, granthcs and weathered tut/8 pne do not w ih mmor matt/md.phhs SILTY SAAIDI(54/)brown,denscne42

CLAYEY SILT AND SANDY O'LT/

(ASL),brown, very shff

%%d herd, moist SAMPLE LOCATION~

DEPTH (FEET/~

TD 04 y'YMBOL EXPLANATION ENGINEERING PARAMETERS Pl olosiicil/indee minus 200 percsni passing 200 tteve WI0 percenl moistvre SS dry densify SAMPLE TYPE Aster Dezz t'ierzi As ra '

zz8 Asrui D 82'4 littrti 4srul D zt'ls. Ii Drive Sample Filcher TubeSample Nk Core,h'O. htdleales Sk Recovery 23 standard penetration Tesi, 'Iv"value ASru Didos.sr CARBONATE CONTENT No Reetclion

+

Siiphil/ Read/i ve Atoderalelf I/Sac/ive

++ Hiph/y ReacHvs

/Dosed on sample redclian to a IDN h'CI UNITS soiuiion/

Vnils column refers lo penerol strahgrapkic diwstans iottnlified silken Ihs basin sedtmenls PALEOMAGNETIC POLARITY Inc/ma/ton a/ remnant magna/re veclot in genera/

agreemenl with /gl or opposilton lo /8/ the present magnetic field.

8Mogneiic vecior indeterminate w depth Paleomagneli c lt ted Reversal~

ID ezr~ elsvailon DESCRIPTIONS Lithologic descriphons were comp/led from peologisls tiold lope, loDarolorf lest dais, ond down-hole geoph/slee.

Field logs were preparsdin accordonca with ASTN D2488-69 Classifications betsed on laboratory leal data ore in accordance wtih 4$ 7/4 0248/-69. /lock descriplions fo/lod procedures oullined in the QUARTERLY OF THE COLORADO SCHOOL OF MINES; Volome 50, No./

Descriptions for color/ Dorinps etre based upon cuminps samples, geoph/sita/

/ops dnd dr/gers'commenls.

LOG OF BORING PV-53