NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION MATERIALS LICENSE PAGE 1 OF 5 PAGES Amendment No. 3 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter I, Parts 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 70 and 71, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below. Licensee 1. Allstate Consultants, LLC In accordance with letter dated 4. Expiration Date: September 30, 2023 May 1-----------....._liill,--~

5. Docket No.: 030-36267
2. 3312 LeMone Industrial Boulevard Columbia, MO 65201 6. Byproduct, source, 7. Chemical affi:!fflr physical and/or special nuclear material A. Cesium-137 A. Sealed ~ou,"e~ _('?~~11'( .. lnternat1on~s10~11j,\, lnstroTek, I

C. Cesium-137 C. Sealed Sources (AEA Technology/QSA, Inc., Model CDCW556; Isotope Product Laboratories, Model HEG-137) Reference No.: \ MaxllJ~unt that lice'asee

9. Authorized use **~ A. For use in CPN International Division of p~rsour~*

milli<::ut:ies total lnstroTek, Inc. Model MC Series ... ,.,..... ' PORTAPROBE portable gauging J\\. f'A devices for measuring physical properties of materials.

i ** *jt, "'t QYV ' 1:3.i\.J' O millicuries ne . urce B. For use in CPN International Division of lnstroTek, Inc. Model MC Series PORTAPROBE portable gauging devices for measuring physical properties of materials.

C. 9 millicuries per source C. For use in Troxler Electronic and 18 millicuries total Laboratories Model 3400 Series portable gauging devices for measuring physical properties of materials.

NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 2 OF 5 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 24-32454-01 Amendment No. 3 Docket or Reference Number 030-36267

6. Byproduct, source, and/or special nuclear material 7. Chemical and/or physical form 8. Maximum amount that licensee may possess at any one time E~ )Pis license 9. Authorized use D. Americium-241 D. 4~il\Ues-Rer source and 88 mfl1i~e~total D. For use in Troxler Electronic Laboratories Model 3400 Series portable gauging devices for measuring physical properties of mateirials.
10. if! cf*"'* Licensed material may be used at temporwjob siffl'~~~!~.,~~ltates WMt;,the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulating the use~y;,:nsed materia(l~F\~}:t~g at*s of e. xcl~e Federal jurisdiction within Agreement States. If the jurisdiction status of a Federal facility witn~ Agreement Sfate'i~unknown, t_!:l~ 0nsee should contact the Federal agenc:y controlling the job site in question to determine whether the ~osed job site is an area of el~sive Federal jurisdiction.

Authorization for use of radioactive materials at job sites in Agreement States n~t\mt~r e!x'~si~E!f

~jral jurisdiction shall be obtained from the appropriate state regulatory agency. , .r~.~ ,.~.'.; 11. Licensed material shall only be used by, or under the supervision and in the physical presence of, individuals who have received the training described in the application dated March 7, 2013. The licensee shall maintain records of individuals designated as users for 3 years following the last use of licensed material by the individual.

12. The Radiation Safety Officer (RSO) for this license is William A. Barrow.

NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 3 OF 5 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 24-32454-01 Amendment No. 3 Docket or Reference Number 030-36267

13. A. Sealed sources and detector cells shall be tested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State. In the absence of a registration certificate, sealed sources sJlalflte tRte lpqk~ge and/or contamination at intervals not to exceed 6 months, or at such other intervals as specified.

~)-' U,( " ~;, B. In the absence of a certificate from a tra~or indicating that a leak test has beeQiade within the intervals specified in th1:i certificate of registration issued by the U.S. Nuclear~ulatory Commission under 10 CFR 32.2~r by an Agreement State, prior to th1e transfer, a sealed source received from anotherO,-son

  • ~got be put into use until t~111 and.tile test results received.

l,,Lj C. Sealed sources need not be testedbey are in or transferred to another person, ari(have not b transfer.

No sealed source shall b~red fot,a p ti) D. The leak test shall be capable of det, sample. If the test reveals the prese filed with the U.S. Nuclear Regulatory immediately from service and decontam E. Analysis of leak test samples and/or contamination

&hall Commission or an Agreement State to perform suctfie the analysis.

when they are removed from storage for use rval, they shall be tested before use or tested for leakage and/or contamination.

J<, 05 mic~ries) of radioactive material on the test . ) or mov.,>f removable contamination, a report shall be R 30.~)(2), and the source shall be removed with Commission regulations.

performed by,1>ersons specifically licensed by the U.S. Nuclear Regulatory l < :~e1(~nsee is authorized to collect leak test samples but not perform k-""' ~<'; / F. Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 years. 14. Sealed sources or source rods containing licensed material shall not be opened or sources removed or detached from source rods or gauges by the licensee, except as specifically authorized.

NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 4 OF 5 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 24-32454-01 Docket or Reference Number 030-36267 Amendment No. 3 15. The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory Commission, to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be maintained for 3 years from the date of each inventory, and shall include tit RioRa!!1'fS~ui1ntities, manufacturer's name and model numbers, and the date of the inventory.

\,~"'* -~.,,J'1{ ,,,,, r' * "'~* ,, iii I ,,J: *~ ,J ',-16. Except for maintaining labeling as required~

CFR Part 20, or Part 71, the license()hall obtain authorization from the U.S. Nuclear Regulatory Commission before making an~an~es in the sealed source, device, or s~e-device combination that would alteir the descri~tio_n or specifications as indicated_

"1e re~~.c. ertificate of registrc!1ii~,jssuedr4ither by the U.S. Nuclear Regulatory Comm1ss1on pursuant to 10 CFR 32.21C1e,by an A*li':nent State. ,I--17. Each portable nuclear gauge shall hav&::{lock or ou sealed source from its shielded positiot=,Jhe ga direct surveillance of an authorized usecl) 18. Any cleaning, maintenance, or repair oft only by the manufacturer or by other pers perform such services.

nauthorized or accidental removal of the I nsport or storage, or when not under the NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 24-32454-01 Amendment No. 3 Docket or Reference Number 030-36267 PAGE 5 OF 5 PAGES 19. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and procedures contained in the documents, including any enclosures, listed below. This license condition applies only to those procedures that are required to be submitted in acw~cef.i£~

fijUlations.

The U.S. Nuclear Regulatory Commissiion's regu~at_ions shall govern u~less the statements, r;P'(,~littons, and proler:.hfr{~,~

the licensee's application and correspondence are more restnct1ve than the regulations.

~\1 fi " '1 1111(11" A. Letter dated March 7, 2013 (ML 13073A~t B. Letter dated June 27, 2018 (ML 18179A"o;a'.

1 3) Date: JUL 1 2 2018 FOR THE U.S. NUCLEAR REGULATORY COMMISSION By: fff:-L / ~D.Tran 1 Regi n 3