NATURAL GAMMA LOG

INCREASING RADIATION~

BASIC SOIL PROPERTI ES LITHOLOGIC DATA PALEO.

CARBONATE MAGNETIC DESCRIPTIONS UNITS 3 CONTENT POLARITY COUNTS PER SECOND 170 190 210 NE66UnEu WEYEE LEVEL 230 250 270 290 PI 2 d 90 100 UO /20 ic n

.6 ELEV. BOI'

SILTY SAIVD WITH GRAVEL/(Shf) bro, subo gular tn subroundnd, poor/y sorted,

/oose, dry.

4

SILTY CLAY WITH SAND/(CL CH),

bro~n.

+

0+

Q POSITIVE e NEGATIVE

SILT'Y CLAY/(CL-CH), Ight gray to whftc tutyaceous/

5ILTY CLAI;./CL-CH), brown.

26 33 27 66

CLAYEY SILT-SILTY CLAY; (AfL-CL) br own to red-brown, very shff to hlrrd, n nrst.

LAYEYSILT AND 5ILTYCLAY; 3

(AIL-CL-CH),brown, medfum tu high plastrcrty, very sbff /o bord, mrna/,

SANDY SILT-SIL7 Y SAVD/(LfL-SH),

Dmwnf sbff to very stfit mcush SILTY CLAY/(CL.CH), rcd-b awn, high plasticity, very stiff to hard, mors/.

SILTY CLAY/(CL-Cu),rad-mwh

<<casfuna/ sflt hmvzons

TD ZSO'AMPLE LOCATION~

DEPTH (FEET)~

SYMBOL EXPLANATION ENGINEERING PARAMETERS Pl alas/icily indes minus 200 percent passlnp ZOO siam/

W/0 aercenl moislure Sd dry denslly SAMPLE TYPE Drive Sample pi/cher TvDe Sample Nx Core,sfd Inured/de Rscovrry slondord pena/ra/ion Teel, "fv"value

~em ness Iisrm nsrnf ossa ssrw Dace /Idyll sera/assis-ri asm 'read.sr CARBONATE CONTENT No Redclion

+

suphlly Reocli ve QSloderafeiy Reactive

++

Niphiy Reactive

/Dosed on sample ress/ion fo o /ON NCI UNITS solulion/

veils column refers lo peneral afro/fgrapnic diwsfons foUnllffed nf/hin Ihe Dosin sedfmenls.

PALEOMAGNETIC POLARITY inc/ma/ion of remnonl mopnelic vcclor /n general opreemen/

wilh f/

or oaposf iron lo /e/

Ihe present mognelic field.

8/dapneifc veclor ifrdelermlnatsv depth Poleomognelfc R

fse Reverso/~

ID ssr slovdlfall D E 5 0 R IPT I0 N5 Lilhologic descrinlions were compiled from pea/opia/a Iield Idps, loDonrlory les/ datd, ond down-hole poodhysics.

Field /ops ware prepared rn accordance

<<ilh ASTN D2488.69 Classificalions Dosed on loborolory les/ dole arein accordance wilh n STsl D2487-69. Itacn descrinlions follow nrocedures ovllined fif /he OUARTERLY OF THE COLORADO SCHOOL OF MINES; Volume SO, No. I Dsscrislions far rolary Dorinps lfre Dosed soon cullinps

samples, gsdnhysfcaf lope ond dr/liars'common/a LOG OF BORING PV-62