Table 1.2-8 CAPABILITY OF RESOURCES*

(1968 through 1986)

EL PASO ELECTRIC COMPANY (Sheet 9 of 11)

Biy Orande gl (Fossil)

Bio Orande g2 (Fossil)

Rio Orande -g3 (Fossil)

Bio Orsnde g4 (Possil)

Rio Orande W (Fossil)

Rio Orande g6 (Possil)"

Rio Orande j{F7 (Fossil)+

Newman k'I (Fossil)

Newman W (Fossil)

Newman g3 (Fossil)

Pour Corners W (Fossil)

Four Corners A (Fossil)

Rio Orande g8 (Fossil)

Newman W Combined Cycle (Fossil)

San Juan g3 (Fossil)

San Juan g4 (Fossil)

ANPP gl (Nuclear)

ANPP A (Nuclear)

ANPP f3 (Nuclear)

Ascarate OT {Fossil)

Newman + OT (Fossil)

Newman g OT (Fossil)

Puture {Fear" >

Total

{1)

Total Peaking (2)

Total Intermediate (3)

Total Rase Load 1968 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 32 (2) 3i (3) 87 (2) 93 (3) 112 (3) 495 140 119 1969 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 24 (2) 24 (3) 87 (2) 93 (3) 112 (3) 56 (3) 536 140 285 1970 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 49 (2) 49 (3) 87 (2) 93 (3) 112 (3) 56 (3) 56 (3) 642 366 1971 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 49 (2) 49 (3) 87 (2) 93 (3) 112 (3) 56 (3) 56 (3) 140 136 366 1972 20 (1) 24 (i) 22 (i) 37 (i) 37 (1) 28 (2) 28 (3) 87 (2) 93 (2) 112 (3) 56 (3) 56 (3) i55 (3) 140 208 407 1973 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 21 (2) 20 (3) 87 (2) 93 (2) 112 (3) 56 (3) 56 (3) i55 (3) 740 140 201 399 1974 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 44 (2) 44 (3) 87 (2) 93 (2) 112 (3) 56 (3) 55 (3) i55 (3) 786 140 224 422 1975 20 (1) 24 (1) 22 (i) 37 (i) 37 (i) i7 (i) i7 (3) 87 (2) 93 (3) 112 (3) 56 (3) 55 (3) i55 (3) 240 (2) 972 157 327 488 1976 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 24 (i) 24 (3) 87 (2) 93 (3) 112 (3) 56 (3) 55()

i55 (3) 240 (2) 986 164 327 495 1977 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 42 (1) 41 (3) 87 (2) 93 (3) 112 (3) 56 (3) 55 (3) 155 (3) 240 (2) 1021 182 327 512 1978 20 {1) 24 (1) 22 (1) 37 (i) 37 (i) 16 (1) 16 (3) 87 (2) 93 (3) 112 (3) 56 (3) 55 (3) 155 (3) 240 {2) i25 (3) 1095 156 327 612 1979 20 {1) 24 (1) 22 (1) 37 (i) 37 (i) 39 {1) 39 (3) 87 (2) 93 (3) ii2 (3) 56 (3)

(3) i55 (3) 24C (2) i25 (:)

125 (3) 1266 179 327 760 1980 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (3) 87 (2) 93 (3) 112 (3) 56 (3) 55 (3) i55 (3) 240 {2) i25 (3) i25 (3) 1244 168 327 749 1981 20 (.1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (3) 87 (2) 93 (2) 112 (3) 56 (3) 55 (3) i55 (3) 240 (2) 125 (3) i25 (3) 200

( 3) 1444 168 420 856 1982 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (3) 87 (2) 93 (2) 112 (3) 56 (3) 55 (3) 155 (3) 240 (2) 125 (3) 125 (3) 200 (3) 1444 168 420 856 1983 20 {1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (2) 87 (2) 93 (2) 112 (2) 56 (3) 55 (3) 155 (3) 240 (2) 125 (3) 200 (3) 200 (3) 1519 168 560 791 1984 20 {1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (2) 87 (2) 93 (2) 112 (2) 56 (3) 55 (3) 155 (3) 240 (2) 200 (3) 200

( 3) 200

( 3) 50 (1) 1644 218 741 1985 20 (1) 24 (1) 22 (1) 37 (i) 37 (i) 28 (1) 28 (2) 87 (2) 93 (2) 112 (2) 56 (3) 55 (3) 155 (3) 240 (2) 0 200 (3) 200

( 3) 200 (3) 50 (i) 65 (1) 65 (1) 1774 685 741 1986 20 (1) 24 (1) 22 (1) 37 (1) 37 (i) 28 (1) 28 (2) 87 (2) 93 (2) 112 (2) 56 (3) 55 (3) 155 (3) 240 (2) 200 (3) 200 (3) 200 (3) 50 (1) 65 (1) 65 (1) 200 (3) 1974 348 685 941

<<Adjusted for contingent power to PNM