Independent Spent Fuel Storage Installation Updated Final Safety Analysis Report, Revision 27
ML18192A500
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 06/29/2018
From: Burchfield J
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
ONS 2018-038
Download: ML18192A500 (8)


Text

ONS 2018-038 June 29, 2018 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-27 46

Subject:

Duke Energy Carolinas, LLC Oconee Nuclear Station, Units 1, 2, and 3 Docket Numbers 72-4, 50-269, 50-270, and 50-287 Independent Spent Fuel Storage Installation Updated Final Safety Analysis Report, Revision 27 J. Ed Burchfield, Jr.

Vice President Oconee Nuclear Station Duke Energy ON01 VP I 7800 Rochester Hwy Seneca, SC 29672 o: 864.873.3478 f: 864.873.5791 Ed.Burchfield@duke-energy.com 10 CFR 72.4 10 CFR 72.48 10 CFR 72.70 Pursuant to 10 CFR 72.48(d)(2), and in accordance with 10 CFR 72.70 and 72.4, Duke Energy Carolinas, LLC (Duke Energy) hereby submits the Oconee Nuclear Station (ONS) Independent Spent Fuel Storage Installation (ISFSI) Updated Final Safety Analysis Report (UFSAR),

Revision 27. The effective date. of the UFSAR revision is December 31, 2017, as indicated at the bottom of each page of text. There were no changes made to the Oconee ISFSI UFSAR in Revision 27.

The Oconee ISFSI UFSAR, Revision 27, is enclosed on one compact disk (CD). The contents are in Adobe Acrobat Portable Document Format (pdf). As required by NRC guidance for electronic submissions, Attachment 1 provides a listing of the document components that comprise the enclosed CD. Attachment 2 provides the List of Effective Pages (LOEP) for Tables and Figures. Attachment 3 provides insertion instructions for those receiving hardcopy distribution.

There were no changes, tests, or experiments performed pursuant to 10 CFR 72.48, for the 2017 calendar year.

/}P6~

/J,vf 55Z ~

rJ ((__~

tJf15S

ONS 2018-038 Document Control Desk June 29, 2018 Page2 This submittal document contains no new or revised regulatory commitments. If you have any questions regarding the submittal, please contact Chris Wasik, Regulatory Affairs Manager, at (864) 873-5789.

I declare under penalty of perjury that the foregoing is true and correct. Executed on June 29, 2018.

Sincerely, JC!~)

J. Ed Burchfield, Jr.

Vice President Oconee Nuclear Station Attachments:

1. Document Components on CD

2. List of Effective Pages (LOEP) for Tables and Figures
3. Update Insertion Instructions (for hardcopy distribution only)

Enclosure:

CD containing Oconee Nuclear Station Independent Spent Fuel Storage Installation Updated Final Safety Analysis Report, 2017 Update - Rev 27

ONS 2018-038 Document Control Desk June 29, 2018 Page 3 xc (with attachments /or enclosure):

Ms. Catherine Haney, Administrator, Region II (CD)

U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE, Suite 1200 Atlanta, GA 30303-1257 Ms. Audrey Klett, Project Manager (CD)

(by electronic mail only)

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-8G9A 11555 Rockville Pike Rockville, Maryland 20852 Mr. Eddy Crowe (hard copy)

NRC Senior Resident Inspector Oconee Nucl~ar Station

ONS 2018-038 Document Control Desk June 29, 2018 - Page 1 of 1 Oconee ISFSI UFSAR-2017 Update Document Components on CD File Name 001 ONS ISFSI Text and Tables Rev 27 002 ONS ISFSI Figures Rev 27 File Size (KB) 2,420 24,969

ONS 2018-038 Document Control Desk June 29, 2018 - Page 1 of 3 Oconee ISFSI UFSAR - 2017 Update List of Effective Pages (LOEP) for Tables and Figures The purpose of this list is to assure that the pages in the Tables and Figures section of your manual match the most recent issue, as well as to show a full acGounting of all tables and figures, including those that have been deleted. The e_arliest effective date, 12/31/07, was used when all tables and figures were re-issued.

Effective Date 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31 /07 12/31/07 12/31 /07 12/31 /07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 Table Table Title No.

A-1 Design Parameters for the Oconee ISFSI A-2 Summary of ISFSI Fuel Handling Operations A-3 Primary Design Parameters for the ISFSI Transport Systems A-4 Major Systems, Subsystems, and Components of the Oconee ISFSI A-5 Population Growth in Oconee, Pickens, and Anderson Counties, South Carolina (1980-2005)

A-6 Population Projections for Oconee, Pickens, and Anderson Counties, South Carolina (2010-2050)

A-7 Joint Frequencies of Wind Direction and Speed by Stability Class A-8 Soil Permeability Test Results A-9 Significant Earthquakes in the Southeast United States (Intensity V or Greater)

A-10 Physical Characteristics of PWR Fuel Assemblies Based on Nominal Design A-11 Transfer Cask Stress Analysis for Tornado Effects A-12 Oconee ISFSI Major Components and Functions A-13 Oconee ISFSI Radioactive Material Confinement Barriers A-14 Oconee ISFSI Major Components and Design Requirements A-15 ONS ISFSI Project Transfer Trailer Design Parameters A-16 Oconee ISFSI Major Components and Classification A-17 Gamma Energy Spectrum A-18 Shielding Analysis Results A-19 Summary of Estimated On-site Doses Resulting from ISFSI Operations (Per DSC Transfer to HSM)

A-20 Dose Estimate for Construction of Additional Horizontal Storage Modules Based on Labor Estimates for 2 X 1 O Array

ONS 2018-038 Document Control Desk June 29, 2018 - Page 2 of 3 Oconee ISFSI UFSAR - 2017 Update List of Effective Pages (LOEP) for Tables and Figures Effective Table Table Title Date No.

12/31/07 12/31/07 12/31/07 Effective Date 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31 /07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31/07 12/31 /07 12/31 /07 12/31/07 12/31/07 12/31/07 A-21 Neutron and Gamma Energy Spectrum A-22 Comparison of Total Dose Rates for HSM With and Without Air Outlet Shielding Blocks

  • A-23 Cask Drop Target Parameters Figure Figure Title No.

B-1 Location of ISFSI B-2 General Location B-3 Site Plan B-4 ISFSI Layout B-5 Topography Within 5 Miles B-6 Relative Positions of Meteorological Instruments B-7 Relative Elevations of Meteorological Instruments B-8 Areal Groundwater Survey B-9 Groundwater Survey at Station Site B-10 Well Permeameter Test Apparatus B-11 Formulae for Determining Permeability B-12 General Site Area B-13 Site Boring Plan B-14 Core*Boring Record B-15 Core Boring Record B-16 Core Boring Record B-17 Core Boring Record B-18 Core Boring Record B-19 Core Boring Record B-20 Core Boring Record B-21 Core Boring Record

ONS 2018-038 Document Control Desk June 29, 2018 Effective Figure Date No.

12/31/07 8-22 12/31/07 8-23 12/31/07 8-24 12/31/07 B-25 12/31/07 8-26 12/31/07 8-27 12/31/07 B-28 12/31 /07 B-29 12/31/07 8-30 12/31/07 B-31 12/31 /07 B-32 12/31/07 8-33 12/31 /07 B-34 12/31/07 8-35 12/31/07 8-36 12/31/07 B-37 12/31/07 8-38 12/31/07 8-39 12/31/07 8-40 12/31/07 8-41 12/31 /07 8-42 12/31/07 8-43 12/31/07 8-44 12/31/07 B-45 12/31/07 8-46 12/31/07 8-47 12/31/07 8-48 - Page 3 of 3 Oconee ISFSI UFSAR - 2017 Update List of Effective Pages (LOEP) for Tables and Figures Figure Title Core Boring Record Core Boring Record Core Boring Record Core Boring Record Core Boring Record Core Boring Record ISFSI Foundation Profile.

Site Layout and Route Site Plan Transfer Cask Lifting Yoke Transfer Cask Lift Extension Spent Fuel Pool Area Spent Fuel Pool Area Spent Fuel Pool Area NUHOMS System Loading Operations Flowchart NUHOMS System Loading Operations Flowchart NUHOMS System Loading Operations Flowchart NUHOMS System Loading Operations Flowchart NUHOMS System Loading Operations Flowchart NUHOMS System Loading Operations Flowchart Location of Dose Rates Dose Rate Versus Distance From Surface of HSM Dose From Filled HSM Array Dose From Filled HSM Array Radiation Zone Map of Modules Surface Dose Rates Deleted Per 1991 Update Fuel Assembly Burnup Requirements

ONS 2018-038 Document Control Desk June 29, 2018 - Page 1 of 1 Oconee ISFSI UFSAR - 2017 Update Update Insertion Instructions For Hard Copy Distribution Only

1.

Replace the 2016 List of Effective Pages (LOEP) for Tables and Figures with the 2017 List of Effective Pages (LOEP) for Tables and Figures.

2.

Replace entire text portions for each chapter with the updated text portion, including the List of Abbreviations,. Table of Contents, List of Figures, and List of Tables.

3.

Note: There were no Tables or Figures updated during this revision.