OFFICIAL USE ONLY PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION June 21, 2018 Mr. James A. Gresham, Manager Regulatory Compliance Westinghouse Electric Company, LLC Suite 428, 1000 Westinghouse Drive Cranberry Township, PA 16066
SUBJECT:
WESTINGHOUSE ELECTRIC COMPANYS FINAL TOPICAL REPORT SAFETY EVALUATION FOR WCAP-16943, ENHANCED GRAY ROD CLUSTER ASSEMBLY RODLET DESIGN
Dear Mr. Gresham:
The U.S. Nuclear Regulatory Commission (NRC) staff prepared a final Topical Report Safety Evaluation (TRSE) for WCAP-16943, Enhanced Gray Rod Cluster Assembly Rodlet Design, in support of the AP1000 post - licensing activities submitted by Westinghouse Electric Company (WEC).
The staff requests that WEC publish the applicable version(s) of the TRSE listed above within 1 month of receipt of this letter. The accepted version of the topical report shall incorporate this letter and the enclosed TRSE and add an -A (designated accepted) following the report identification number.
The staff has found that WCAP-16943 is acceptable for referencing in licensing applications for AP1000 designed pressurized water reactors to the extent specified and under the limitations delineated in the topical report and in the enclosed final TRSE. The final TRSE defines the basis for our acceptance of the topical report.
If the NRCs criteria or regulations change, so that its conclusion that the TRSE is acceptable is invalidated, WEC and/or the applicant referencing the TRSE will be expected to revise and resubmit its respective documentation, or submit justification for continued applicability of the TRSE without revision of the respective documentation.
Prior to placing the public version of this document in the public document room the staff requests that WEC perform a final review of the TRSE for proprietary or security-related information not previously identified. If you believe that any additional information meets the criteria, please identify such information line by line and define the basis pursuant to the criteria established in Title 10 of the Code of Federal Regulations Part 2, Section 390.
Document transmitted herewith contains sensitive unclassified information. When separated from the enclosure, this document is DECONTROLLED.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION If after a 10day period, you do not request that all or portions of the TRSE be withheld from public disclosure, the TRSE will be made available for public inspection through the NRC Public Document Room and the Publicly Available Records component of NRCs Agencywide Documents Access and Management System and placed on the NRCs public web page for this application.
If you have any questions or comments concerning this matter, please contact me at 301-415-6715 or via e-mail address at Bruce.Bavol@nrc.gov.
Sincerely,
/RA/
Bruce M. Bavol, Project Manager Licensing Branch 4 Division of New Reactor Licensing Office of New Reactors Docket No.: 52-006
Enclosure:
As stated cc w/o encl.: See next page
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION
SUBJECT:
WESTINGHOUSE ELECTRIC COMPANYS FINAL TOPICAL REPORT SAFETY EVALUATION FOR WCAP-16943, ENHANCED GRAY ROD CLUSTER ASSEMBLY RODLET DESIGN DATED: JUNE 21, 2018 DISTRIBUTION:
PUBLIC NRO_DLSE_LB4 RButler RidsAcrsAcnwMailCenter JDonoghue RidsOgcMailCenter MSpencer, OGC RidsAcrsAcnwMailCenter CVanWert RidsNrrOd Yi-Hsiung Hsai RWeisman, OGC ADAMS ACCESSION NOs.:
PKG: ML18178A146 LETTER: ML18172A042 SER: ML12193A300 (Proprietary)
SER: ML12193A278 (Non-Proprietary)
NRO-008 OFFICE LA:DNRL/LB4 PM:DNRL/LB4 BC:DNRL/LB4 OGC BC:DLSE/LB4 NAME RButler BBavol MTonacci RWeisman*
JDixon-Herrity DATE 07/10/2012 07/12/2012 07/12/2012 5/23/2018 06/21/2018 OFFICIAL RECORD COPY
DCWG - AP1000 Mailing List (Revised 12/20/2017) cc:
Paul M. Bessette Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mr. Barton Z. Cowan, Esquire Eckert Seamans Cherin & Mellott, LLC 600 Grant Street, 44th Floor Pittsburgh, PA 15219 Mr. Eugene S. Grecheck Vice President Nuclear Support Services Dominion Energy, Inc.
5000 Dominion Blvd.
Glen Allen, VA 23060
DCWG - AP1000 Mailing List Email pshastings@generationmpower,com (Peter Hastings) agaughtm@southernco.com (Amy Aughtman) amonroe@scana.com (Amy Monroe)
APH@NEI.org (Adrian Heymer) awc@nei.org (Anne W. Cottingham) benjamja@westinghouse.com Bill.Jacobs@gdsassociates.com (Bill Jacobs) collinlj@westinghouse.com (Leslie Collins)
CumminWE@Westinghouse.com (Edward W. Cummins) cwaltman@roe.com (C. Waltman) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) easterr@westinghouse.com (Rick Easterling) ecullington@earthlink.net (E. Cullington) eddie.grant@excelservices.com (Eddie Grant) erg-xl@cox.net (Eddie R. Grant) fbelser@regstaff.sc.gov George.Madden@fpl.com (George Madden)
George_Stramback@Charter.net (George Stramback) james1.beard@ge.com (James Beard) jannina.blanco@pillsburylaw.com (Jannina Blanco) jerald.head@ge.com (Jerald G. Head) jflitter@regstaff.sc.gov jim@ncwarn.org (Jim Warren) john.elnitsky@pgnmail.com (John Elnitsky)
Joseph_Hegner@dom.com (Joseph Hegner) jrappe@nuscalepower.com (Jodi Rappe) kinneyrw@dhec.sc.gov (Ronald Kinney)
KSutton@morganlewis.com (Kathryn M. Sutton) kuylerr@westinghouse.com (Ray Kuyler) kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler) maurerbf@westinghouse.com (Brad Maurer) media@nei.org (Scott Peterson)
MSF@nei.org (Marvin Fertel) nirsnet@nirs.org (Michael Mariotte) nscjiangguang@sina.com (Jiang Guang)
Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell) paul.gaukler@pillsburylaw.com (Paul Gaukler)
Paul.Jacobs@fpl.com (Paul Jacobs)
Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette)
Page 2 of 3
DCWG - AP1000 Mailing List Raymond.Burski@fpl.com (Raymond Burski)
Rebecca.Smith-Kevern@nuclear.energy.gov (Rebecca Smith-Kevern) rgrumbir@gmail.com (Richard Grumbir)
Richard.Orthen@fpl.com (Richard Orthen) ritterse@westinghouse.com (Stanley E. Ritterbusch)
RJB@NEI.org (Russell Bell) robert.kitchen@pgnmail.com (Robert H. Kitchen) rong-pan@263.net (Pan Rong) sabinski@suddenlink.net (Steve A. Bennett) sara@cleanenergy.org (Sara Barczak) shudson@regstaff.sc.gov (Shannon Hudson) sisk1rb@westinghouse.com (Rob Sisk) stephan.moen@ge.com (Stephan Moen) stephen.burdick@morganlewis.com (Stephen Burdick)
Steve.Franzone@fpl.com (Steve Franzone)
Tansel.Selekler@nuclear.energy.gov (Tansel Selekler) timothy.beville@nuclear.energy.gov (Timothy Beville) tomccall@southernco.com (Tom McCallum)
TomClements329@cs.com (Tom Clements) trsmith@winston.com (Tyson Smith)
Vanessa.quinn@dhs.gov (Vanessa Quinn) vijukrp@westinghouse.com (Ronald P. Vijuk) weave1dw@westinghouse.com (Doug Weaver) whorin@winston.com (W. Horin) x2gabeck@southernco.com (Gary Becker)
Page 3 of 3