ML18157A263

From kanterella
Jump to navigation Jump to search
Non-Concurrence on Final ASP Program Analysis Precursor High Pressure Core Spray System Inoperable Due to Injection Valve Stem Disc Separation LaSalle County Station, Unit 2 NCP-2018-002
Date released: 07/19/2018 Download: ML18157A263


Transmittal of Final LaSalle County Station Unit 2 Accident Sequence Precursor Report (Licensee Event Report 374-2017-003-01)
ML18180A326
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 07/03/2018
From: Bhalchandra Vaidya
Plant Licensing Branch III
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
Vaidya B K
References
LER 2017-003-01
Download: ML18180A326 (45)
Non-Concurrence on Final ASP Program Analysis for Lasalle,Unit 2, HPCS System Unavailable
ML18157A264
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 06/14/2018
From: Dale Yeilding
NRC/RES/DRA/PRB
To:
J. Lane 415-2476
References
NCP-2018-002
Download: ML18157A264 (28)
High-Pressure Core Spray System Inoperable Due to Injection Valve Stem-Disc Separation- Precursor (LER 374-2017-003)
ML18072A326
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 07/09/2018
From: Dale Yeilding
NRC/RES/DRA/PRB
To:
References
LER 374-2017-001, LER 374-2017-002, LER 374-2017-003, LER 374-2017-003-01
Download: ML18072A326 (11)