UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 29, 2018 Mr. Royston Ngwayah Licensing Engineer Holtec International One Holtec Blvd Camden, NJ 08104
SUBJECT:
SECOND REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. HI-STAR ATB 1T PACKAGE
Dear Mr. Ngwayah:
By letter dated February 6, 2017, you submitted an application for Certificate of Compliance No.
9375, Revision No. 0, for the Model No. HI-STAR ATB 1T package. By letter dated April 14, 2017, you responded to our request for supplemental information (RSI) letter dated March 21, 2017. By letter dated December 8, 2017, you responded to our first request for additional information (RAI) letter dated August 9, 2017, and you completed your RAI responses by letter dated April 2, 2018.
In connection with the staffs review of the application, we need the information identified in the enclosure to this letter. We request that you provide this information by August 6, 2018.
Further, we propose to conduct a public meeting with you to discuss specific aspects of your submittal, as the staff continues to have numerous and significant technical concerns with this package design.
Please reference Docket No. 71-9375 and EPID L-2017-LLA-0059 in future correspondence related to this request. If you have any questions regarding this matter, I may be contacted at (301) 415-7505.
Sincerely,
/RA/
Pierre Saverot, Project Manager Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9375 EPID L-2017-LLA-0059 (previously CAC No. L25185)
Enclosure:
Second Request for Additional Information
R. Ngwayah 2
SECOND REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. HI-STAR ATB 1T PACKAGE, DOCUMENT DATE: May 29, 2018 DISTRIBUTION: SFST r/f RPowell, RI SWalker, RII MKunowski, RIII JWhitten, RIV G:\\SFST\\Saverot\\HI-STAR ATB 1T\\2ndRAI letter.doc ; 2ndRAI.doc ADAMS Package ML18156A173 Letter : ML18156A174 Enclosure : ML18156A176 OFC:
SFM E
SFM E
SFM C
SFM SFM SFM NAME:
PSaverot ARigato JBorowski VWilson DTarantino HGonzalez DATE:
03/12/2018 03/15/2018 03/15/2018 03/20/2018 03/22/2018 04/11/2018 OFC:
SFM E
SFM E
SFM C
SFM SFM SFM C
NAME:
YDiaz-Sanabria MRahimi TTate SFigueroa JMcKirgan AHsia /
MLayton DATE: