10
- 7.
Licensee Action on Previous Insp_ection Findings.
(Closed) IFI 50-280, 50-281/92-21-02:
Reviewing_ methodology for generating PARs.
The licensee made extensive procedural changes following review of the scheme for deriving PARs.
During a SAE or General Emergency, a new EPIP-1.06, "Protective Action Recommendations" (Revision 0, dated June 1, 1993), provided the SEM with a much more streamlined and less cumbersome methodology for determining the appropriate PAR for offsite authorities. Also revised were EPIP-4.07, "Protective Measures" (Revision 4, dated June 1, 1993), to incorporate the results of the latest evacuation time estimates, and EPIP~2.0l, "Notification of State and Local Governments" (Revision 19, dated June 1, 1993), to simplify the process of transmitting a PAR to offsite authorities.
- 8.
Exit Interview The inspection scope and results were summarized on June 11, 1993 with those persons indicated in Paragraph 1.
The inspector described the areas assessed and discussed the inspection results in detail. Licensee management was informed that the three concerns discussed in Paragraph 5 would be tracked as IFis, and that an IFI from a previous inspection was considered closed, as noted in Paragraph 7.
Dissenting comments were not received from the licensee. Although proprietary information was reviewed during this inspection, none is contained in this report.
Subsequent to the exit interview, documentation was provided by the licensee to the inspector regarding completed corrective actions to address the new IFis.
As delineated in Paragraph 5, the inspector concluded that the licensee had fully resolved the concerns that had been identified as IFis during the exit interview.
On June 30, 1993, the inspector informed the Station Coordinator, Emergency Planning, of this determination. *
- 9.
Index of Abbreviations Used in This Report ALARA ATWT CFR CTS EAL EPA EPIP
_ERF EWS FEMA HEPA IN LEOF NOUE NRC As Low As Reasonably Achievable Anticipated Transient Without Trip Code of Federal Regulations Commitment Tracking System Emergency Action Level Environmental Protection Agency Emergency Pl~n Implementing Procedure Emergency Response Facility Early Warning System Federal Emergency Management Agency high-efficiency particulate air Information Notice Local ~mergency Operations Facility Notification of Unusual Event Nuclear Regulatory Commission