VIRGINIA ELECTRIC AND PowEH COMPANY RICHMOND, VIRGINIA 23261 September 22, 1992 United States Nuclear Regulatory Commission Attention: Document Control Desk -

Washington, D. C. 20555 Serial No.

92-226A SPS/RCB/GDM R3 Docket Nos.

50-280 50-281_

License Nos.

DPR-32 DPR-37 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 SUPPLEMENT TO REPLY TO A NOTICE OF VIOLATION NRC INSPECTION REPORT NOS. 50-280/92-04 AND 50-281/92-04 In NRC Inspection Report Nos. 50-280/92-04 and 50-281/92-;04 dated April 27, 1992, we were cited for failure to properly correct high head safety injection-pump lube oil

  • temperature control valve (TCV) deficiencies. In our reply, we committed to correct the condition adverse to quality by replacing the TCVs with valves better adapted to the working conditions.

These replacements were completed as scheduled, and full compliance with operational requirements has been achieved.

As a further improvement, we had also planned to replace the associated temperature controllers.

However, based on the reliable performance of the replacement valves thus far, we have concluded that replacement of the controllers is not required at this time. Should additional problems arise in the future, we will reevaluate this decision.

Please contact us if you have any questions or require additional information.

Very truly yours,

. y~( :?~_-:<_j_~---:+

\\,,j '~ ) \\_jJJ,.,.* :-~---

w. L. Stewart

~

Senior Vice President - Nuclear cc:

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.

Atlanta, Georgia 30323 Mr. Morris Branch NRC Senior Resident Inspector

  • Surry Power Station 9209250332 920922 PDR ADOCK 05000280 Q

PDR r-601