Text
---~ ~------ -~- --~~
e Docket Nos. 50-280 and 50-281 Mr. W. L. Stewart Senior Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
Dear Mr. Stewart:
August 7, 1992~
DISTRIBUTION:
Docket File NRC & Local PDRs G. Lainas B. Buckley S. T. Hoffman ACRS (10)
PD22 Rdg S. Varga H. Berkow D. Miller OGC M. Sinkule, RII
SUBJECT:
RESPONSE TO GENERIC LETTER 91-11, "RESOLUTION OF GENERIC ISSUE 48,
'LCO'S FOR CLASS IE VITAL INSTRUMENT BUSES,' AND 49, 'INTERLOCKS AND LCO'S FOR CLASS IE TIE BREAKERS,' PURSUANT TO 10 CFR 50.54(f)" FOR SURRY POWER STATION, UNITS 1 AND 2 (TAC NOS. M82474 AND M82475)
On July 18, 1991, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 91-11 which contained the staff resolution of Generic Issues 48 and 49.
The GL required that licensees certify that procedures exist which contain time limitations and surveillance requirements for vital instrument buses (VIBs), inverters or other onsite power sources for VIBs, and tie breakers.
If procedures do not exist, a justification demonstrating the reasons why the controls are not needed is required.
By letter dated January 31, 1992, you responded to the GL.
You indicated that administrative controls and procedures are in place.
The staff has reviewed your response and finds that it meets the reporting requirements set forth in GL 91-11.
This completes the staff's activities on TAC Nos. M82474 and M82475.
cc:
See next page OFFICE L
NAME D
DATE Sincerely, (Original Signed By)
Bart Buckley, Senior Project Manager Project Directorate II-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation I I I I
J Mr. W. L. Stewart Virginia Electric and Power Company cc:
Michael W. Maupin, Esq.
Hunton and Williams Post Office Box 1535 Richmond, Virginia 23212 Mr. Michael R. Kansler, Manager Surry Power Station Post Office Box 315 Surry, Virginia 23883 Senio~ Resident Inspector Surry Power Station U.S. Nuclear Regulatory Commission Post Office Box 166, Route 1 Surry, Virginia 23883 Mr. Sherlock Holmes, Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Dr. W. T. Lough Virginia State Corporation Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23209 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 C.M.G. Buttery, M.D., M.P.H.
State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 Surry Power Station Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 Mr. E. Wayne Harrell Vice President - Nuclear Services Virginia Electric and Power Co.
5000 Dominion Blvd.
Glen Allen, Virginia 23060 Mr. J. P. O'Hanlon Vice President - Nuclear Operations Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060 Mr. Martin Bowling Manager - Nuclear Licensing Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060