e UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket Nos. 50-280 and 50-281 Mr. W. L. Stewart Senior Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
Dear Mr. Stewart:
Apgust 27, 1990
SUBJECT:
SURRY UNITS 1 AND 2-INSERVICE TESTING PROGRAM (TAC NOS. 65555 AND 65556)*
By letter dated September 30, 1988, as supplemented February 22, 1989, and January 17, 19901 Virginia Electric and Power Company submitted an Inservice Testing Program lIST).
The !ST included requests for various reliefs from Section XI of the ASME Boiler and Pressure Vessel Code.
The staff,.with the help of our consultant, EG&G Idaho (EG&G), has evaluated these relief requests. The staff has adopted the evaluations and conclusions contained in the EG&G Report.
As detailed in the staff's Safety Evaluation, 7 of the requested reliefs were granted, 1 interim relief was granted for a period of 3 years, 16 were granted with certain conditions, 1 was partially denied, and 3 are still under review.
Copies of the staff's Safety Evaluation and the Technical Evaluation Report supplied by EG&G are enclosed.
The staff has determined that granting relief pursuant to 10 CFR 50.55a{a)(3}(i) and 10 CFR 50.55a(g)(6)(i), is authorized by law and will not endanger life or property, or the common defense and security, and is otherwise in the public interest. In making this determination, the staff has considered the alternate testing being implemented, and the impracticality of performing the required testing considering the burden upon the licensee if the requirements were imposed. Table 1 of the enclosed Safety Evaluation summarizes the staff's position on each relief request. For each request for which relief was given, the last column of this table identifies the regulation under which the requested relief is granted.
The staff has further determined that the relief requests in the !ST Program for the Surry Power Station are acceptable for implementation provided that the
=-::--::::~::;-:::,...:;:,7;----~,1
,---- 9()(19 :I. 10094* 9008,::'.
I
\\
~6~*
ADOCK ~§000280 i
1 PDC
r- -
l e
W. August 27, 1990 omissions and inconsistencies identified in Appendix C to the EG&G TER are corrected within 90 days of receipt of this letter, unless otherwise allowed in the TER.
Enclosures:
- 1. Safety Evaluation
- 2.
TER #EGG-NT4-8414 dated March 1990 cc w/enclosures:
See next page DISTRIBUTION:
- Docket File,.
NRC & Local PDRs PD22 Rdg. File SVarga Glainas DMi ller BBuckley GWunder OGC ACRS (10)
TMurley/FMiraglia JPartlow GHi 11 (4)
OC/LFMP GPA/PA HBerkow Sincerely,
/S/
Herbert N. Berkow, Director Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation MSinkule, RII
- SEE PREVIOUS CONCURRENCE
-A*.
OFC
- LA:PDII-2*
- PM:PDII-2*
- PM:PDII-2
- D:PDII-2
- OGC
*----------------*--------------*--------------*--------------*------t'- -----*-------------
NAME
~DMiller
. ~GWunder:sl
~BBuckley
~HB~
~ e}\\oi.t,e,1L.~
. DATE
- 5/6/90- -. -. * *.. :5/6/90 *
- 8/f'f/90 * - ** -- -:8/j.1/90-.. -- --:8/(7/90-. --- - :
OFFICIAL RECORD COPY Document Name:
IT PROGRAM
I Ir r
e W. August 27, 1990 omissions and inconsistencies identified in Appendix C to the EG&G TER are corrected within 90 days of receipt of this letter, unless otherwise allowed in the TER.
Enclosures:
- 1. Safety Evaluation
- 2.
TER #EGG-NT4-8414 dated March 1990 cc w/enclosures:
See next page Sincerely,
~.~
Herbert N. Berkow, Director Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation
e Mr. W. L. Stewart Virginia Electric and Power Company cc:
Michael W. Maupin, Esq.
Hunton and Wi]liams Post Office Box 1535 Richmond, Virginia 23212 Mr. Michael R. Kansler, Manager Surry Power Stati~n Post Office Box 11>5 Surry, Virginia 23883 Senior Resident )nspector Surry Power Station U.S. Nuclear Regulatory Commission Post Office Box 166, Route 1
'Surry, Virginia 23883 Mr. Sherlock Holmes, Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Mr. W. T. Lough Virginia Corpo,ration Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23209 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 C. M. G. Buttery, M.D., M.P.H.
Department of Health 109 Governor Street Richmond, Virginia 23219 Surry Power Station Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 Mr. E. Wayne Harrell Vice President - Nuclear Operations Virginia Electric and Power Company 5000 Old Dominion Blvd.
Glen Allen, Virginia 23060 Mr. J.P. O'Hanlon Vice President - Nuclear Services Virginia Electric and Power Company 5000 Old Dominion Blvd.
Glen Allen, Virginia 23060 Mr. R. F. Saunders Manager - Nuclear Licensing Virginia Electric and Power Company 5000 Old Dominion Blvd.
Glen Allen, Virginia 23060