ATTACHMENT SURRY POWER STATION PROPOSED TECHNICAL SPECIFICATION CHANGE OFFSITE COMMITTEE REVIEW FUNCTION REVISED PAGES

-~.

900803005~ ?QQ?~~n-F.'flO onn~K u~uuu~ou

  • - I"\\

I***- - -

F'[I(:

p

1..

TS 6.1-10

e.

Meeting Frequency The MSRC shall meet at least once per calendar quarter.

f.

Quorum The minimum quorum of the MSRC necessary for the performance of the MSRC review and audit functions of these Technical Specifications shall consist of the Chairman or his designated alternate and at least 50% of the MSRC members including alternates.

No more than a minority of the quorum shall have line responsibility for operation of the unit.

g.

Review The MSRC shall be responsible for the review of:

1.

The safety evaluations for 1) changes to procedures, equipment or systems and 2) tests or experiments completed under the provision of Section 50.59, 10 CFR, to verify that such actions did not constitute an unreviewed safety question.

2.

Proposed changes to procedures, equipment or systems which involve an unreviewed safety question as defined in Section 50.59, 1 O CFR.

3.

Proposed tests or experiments which involve an unreviewed safety question as defined in Section 50.59,

  • 10 CFR.
4.

Proposed changes to Technical Specifications or the Operating Licenses.

1, e

TS 6.1-12

4.

The performance of activities required by the Operational Quality Assurance Program to meet the criteria of Appendix "B", 1 O CFR 50, at least once per 24 months.

5.

The Emergency Plan and implementing procedures at least once per 12 months.

6.

The Security Plan and implementing procedures at least once per 12 months.

7.

Any other area of facility operation considered appropriate by the MSRC or the Vice President - Nuclear Operations.

8.

The Fire Protection Program and implementing procedures at least once per 24 months.

9.

An independent fire protection and loss prevention inspection and audit shall be performed annually utilizing either qualified offsite licensee personnel or an outside fire protection firm.

10.

An inspection and audit of the fire protection and loss prevention program shall be performed by an outside qualified fire consultant at intervals no greater than 3 years.

11.

The radiological environmental monitoring program at

  • least once per 12 months.
12.

The Offsite Dose Calculation Manual and implementing procedures at least once per 12 months.

13.

The Process Control Program and implementing procedures for processing and packaging of radioactive waste at least once per 12 months.

. ~

TS 6.1-13

i.

Authority The MSRC shall report to and advise the Senior Vice President Nuclear on those areas of responsibility specified in Sections 6.1.c.2.g and 6.1.c.2.h.

j.

Records Records of MSRC activities shall be prepared, approved and distributed as indicated below:

1.

Minutes of each MSRC meeting shall be prepared, approved and forwarded to the Senior Vice President -

Nuclear within 14 days of each meeting.

2.

Reports of reviews with safety significant findings encompassed by Section 6.1.c.2.g above, shall be prepared, approved and forwarded to the Senior Vice President - Nuclear within 14 days following completion of the review.

3.

Audit reports encompassed by Section 6.1.c.2.h above, shall be forwarded to the Senior Vice President - Nuclear and to the management positions responsible for the areas audited within 30 days after completion of the audit by the auditing organization.