Forwards Safety Evaluation Supporting Use of Topical Rept VEP-NE-3, Qualification of WRB-1 Critical Heat Flux Correlation in VEPCO Cobra Code, W/Constraint That Min Grid Spacing Will Be 13 Inches or Greater
ML18153B825
Person / Time
Site: Surry, North Anna, 05000000
Issue date: 07/25/1989
From: Lainas G
Office of Nuclear Reactor Regulation
To: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML18153B826 List:
References
TAC-67363, TAC-67364, TAC-71071, TAC-71072, NUDOCS 8907310461
Download: ML18153B825 (2)


Text

r e

  • Docket Nos. 50-280, 50-281, 50-338 and 50-339 Mr. W. R. Cartwright Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, Virginia 23060

Dear Mr. Cartwright:

July 25, 1989 DISTRIBUTION Docket File

  • NRC & Local PDRs PDII-2 Rdg.

SVarga, 14/E/4 GLainas, 14/H/3 HBerkow DMi 11 er BBuckley LEngle OGC (info. only)

EJordan, 3302MNBB BGrimes, 9/A/2 ACRS (10)

MS i n ku 1 e, R II

SUBJECT:

SURRY UNITS 1 AND 2, AND NORTH ANNA UNITS 1 AND 2 - USE OF VIRGINIA POWER TOPICAL REPORT VEP-NE-3, 11QUALIFICATION OF THE WRB-1 CHF CORRELATION IN THE VIRGINIA POWER COBRA CODE 11 (TAC NOS. 67363, 67364, 71071 AND 71072)

By letter dated January 29, 1987, you requested approval of the above subject Topical Report VEP-NE-3 to use the WRB-1 correlation to perform Departure from Nucleate Boiling Ratio analyses for the Surry and North Anna Power Stations.

Based on our review, with assistance from our consultant, Pacific Northwest Laboratories, we conclude that the VEP-NE-3 Topical Report is acceptable for application at the Surry and North Anna Power Stations with the constraints 2

that the critical heat fluxes shall not exceed 1.0 MBtu/hr-ft and that the minimum grid spacing shall be 13 inches or greater.

Enclosure:

As stated cc w/enclosure:

Safety Evaluation

[SURRY/NA-1&2 TOPICAL LTR]

PM: f?ff22 BBuckley:bld 07 /'2. 't/89 Sincerely, Original signed by Gus C. Lainas, Assistant Director for Region II Reactors Division of Reactor Projects I/II Office of Nuclear Reactor Regulation P&2 D:P~

HB&~

07 /J-t.(/89

. _(/.J. I

~~s LEngle 07 /tf /89 07t> 189

. ~11 1'1-f

/VtTI 1e,..

.\\

Ge..-

'Mr. W. R. Cartwright North Anna Power Station, Units 1&2 Surry Power Station, Units 1&2 cc:

Mr. William C. Porter, Jr.

County Administrator Louisa County P.O. Box 160 Louisa, Virginia 23093 Michael W. Maupin, Esq.

Hunton and Williams P. 0. Box 1535 Richmond, Virginia 23212 Mr. W. T. Lough Virginia Corporation Commission Division of Energy Regulation P. 0. Box 1197 Richmond, Virginia 23209 Old Dominion Electric Cooperative c/o Executive Vice President Innsbrook Corporate Center 4222 Cox Road, Suite 102 Glen Allen, Virginia 23060 Mr. W. L. Stewart Senior Vice President - Power Virginia Electric and Power Co.

Post Office Box 26666 Richmond, Virginia 23261 Mr. Patrick A. 0 1Hare Office of the Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 Resident Inspector/North Anna c/o U.S. NRC Senior Resident Inspector Route 2, Box 78 Mineral, Virginia 23117 Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 C. M. G. Buttery, M.D., M.P.H.

Department of Health 109 Governor Street Richmond, Virginia 23219 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Mr. G. E. Kane P. 0. Box 402 Mineral, Virginia 23117 Mr. W. R. Cartwright Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, Virginia 23060 Mr. Michael Kansler, Manager Surry Power Station Post Office Box 315 Surry, Virginia 23883 Resident Inspector Surry Power Station U.S. Nuclear Regulatory Commission Post Office Box 166, Route 1 Surry, Virginia 23883 Mr. Sherlock Holmes, Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683