UNITED STATES
- NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket Nos. 50-280, 50-281 and 50-338, 50-339 Mr. W. R. Cartwright Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
Dear Mr. Cartwright:
June 19, 1 989
SUBJECT:
NORTH ANNA UNITS 1 AND 2, AND SURRY UNITS 1 AND 2 - USE OF CODE CASES N341 AND N356 FOR LEVEL *III CERTIFICATION AND USE OF PARAGRAPH IWA-2213 (WINTER 1984 ADDENDA)
(TAC NOS. 73133, 73134, 72915 AND 72916)
By letter dated October 6, 1988, you requested approval to implement Code Ca~e N341 (ASME Section III) and Code Case N356 (ASME Section XI) for the recertification of your nondestructive examination (NDE) Level III personnel.
You also.requested approval to use the visual examination VT-3 requirements of Paragraph IWA-2213 in the Winter 1984 Addenda in lieu of your current requirement to conduct a visual examination pursuant to Paragraph IWA-2213, VT-3 and Paragraph IWA-2214, VT-4.
Your first request, if granted, would allow you to recertify your NDE Level III personnel at the Surry and North Anna facilities on a 5-year cycle, instead of the current 3-year cycle.
Code Case N341 (ASME Section III), which allows recertification on a 5-year cycle, has been _found to be acceptable to the NRC staff and has been incorporated into Regulatory Guide 1.84, "Design and Fabrica-tion Code Case Acceptability, ASME Section III,* Division I.
11 Code Case N356 (ASME Section XI), which also allows recertification of Level III NOE personnel on a 5-year cycle, is acceptable to the NRC staff and has been incorporated into later editions of the ASME Code (specifically, the Winter 1983 Addenda).
Therefore, your request to utilize Code Cases N341 and N356 is approved for both Surry and North Anna.
With regard to your request to use Paragraph IWA-2213 VT-3 in the Winter 1984 Addenda for visual examinations, we find your request acceptable for Surry and North Anna, since Paragraphs IWA-2213, VJ-3 and IWA-2214, VT-4 were combined into a si-ngle examination category VT-3 in the Winter 1984 Addenda and approved by the NRC.
J)fof
- -.,:.,9(1619 _ *
- -_.. -=-,*1 '*,?:-_*:(10:.:::.::.
V C,. * '( I Lo' (1500 Jh=*.
F:CIR - ADOCr-.
- p[IC
,f, p
Mr. W.R. Cartwright 2 -
June 19, 1 989 This completes our review efforts and closes out TAC Nos. 72915 and 72916 (for Surry Units 1 and 2), as well as TAC Nos. 73133 and 73134 (for North Anna Uni ts 1 and 2)
- cc:
See next page DISTRIBUTION Docket File NRC & Local PDRs PDII-2 Reading T. Murley/J. Sniezek, 12/G/18 J. Partlow, 12/G/18 E. Rossi, 11/E/4 S. Varga, 14/E/4 G. Lainas, 14/H/3 H. Berkow D. Miller L. Engle B. Buckley OGC (info. only)
E. Jordan, 3302 MNBB B. Grimes, 9/A/2 T. Meek (16)
ACRS (10)
GPA/PA ARM/LFMB P. Frederickson, RII Sincerely, Original si~ned by Herbert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation
[NA/SURRY LEVEL III CERT. LTR] ~
'?Cf)
LA~-2 PM:PDII-2 PM:
-2 E~C, o~l-1'~ ~t BBuckley LEng le 05/7],,W-89 05/2,)/89 0,1<! \\189 cycheng O§/"v'/89
Mr. W. R. Cartwright Virginia Electric & Power Company cc:
Mr. William C. Porter, Jr.
County Administrator Louisa County P.O. Box 160 Louisa, Virginia 23093 Michael W. Maupin, Esq.
Hunton and Williams P.O. Box 1535 Richmond, Virginia 23212 Mr. W. T. Lough Virginia Corporation Convnission Division of Energy Regulation P.O. Box 1197 Richmond, Virginia 23209 Old Dominion Electric Cooperative c/o Executive Vice President Innsbrook Corporate Center 4222 Cox Road, Suite 102 Glen Allen, Virginia 23060 Mr. W. L. Stewart Senior Vice President - Power Virginia Electric and Power Co.
Post Office Box 26666 Richmond, Virginia 23261 Mr. Patrick A. O'Hare Office of the Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 Resident Inspector/North Anna c/o U.S. NRC Senipr Resident Inspector Rout,e 2, Box 78 Min1ral, Virginia 23117 North Anna Power Station, Units 1&2 Surry Power Station, Units 1&2 C. M. G. Buttery, M.D., M.P.H.
Department of Health 109 Governor Street Richmond, Virginia 23219 Regional Administrator, Region II U.S. Nuclear Regulatory Conmission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Mr. G. E. Kane P. 0. Box 402 Mineral, Virginia 23117 Mr. Sherlock Holmes, Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Mr. Michael Kansler, Manager Surry Power Station Post Office Box 315 Surry, Virginia 23883 Resident Inspector Surry Power Station U.S *. Nuclear Regulatory Commission Post Office Box 166, Route 1 Surry, Virginia 23883