Discusses Turbine Trip/Reactor Trip That Occurred from 100% Power on 930416.Requests Evaluation & Conclusions of Two Human Factor Issues Identified in Human Performance Study Rept on 930418
ML18153B308
Person / Time
Site: Surry, North Anna  
Issue date: 08/16/1993
From: Berkow H
Office of Nuclear Reactor Regulation
To: Eckenrode R
Office of Nuclear Reactor Regulation
Shared Package
ML18153B309 List:
References
TAC-M87203, NUDOCS 9309130271
Download: ML18153B308 (3)


Text

  • .

d.Dolket Nos. S0-338, 50-~.

50-1~80 and 50-*

August 16, 13 MEMORANDUM FOR:

Richard J. Eckenrode~ Acting Branch Chief Human Factors Assessment Branch FROM:

SUBJECT:

Division of Reactor Controls and Human Factors Herbert N. Berkow, Director Project Dfrectorate II-2 Division of Reactor Projects~ I/II Office of Nuclear Reactor Regulation NORTH ANNA POWER STATION, UNIT 2, SAFETY FEATURES BYPASS (APRIL 16, 1993) (TAC NO. M87203)

On April 16, 1993, a turbine trip/reactor trip occurred from 100% power.

The main feedwater pumps continued to operate and the auxilary feedwater (AFW) pumps started automatically when the steam generator level dropped.

A reactor operator (RO) then secured the AFW pumps to prevent overcooling.

However, the RO secureid the AFW by placing all AFW puinps in pull-to-lock (PTL) rather than in the "auto position. Therefore, the AFW would not have started automatically if called upon by safety actuation.

The AFW system was inoperable for 18 minutes until an SRO noticed the PTL position *and the RO returned the AFW switches to their normal positions.

As a result of this event, AEOD sent a team to North Anna to assess the human factors aspects and issued a Human Performance Study Report on April. 18, 1993.

In a memorandum (attached) from E. Jordan, Director, AEOD, to T. F. Murley, Director, NRR, and S.D. Ebnet~r,*Regional Administrator, RII, dated July 2, 1992, two human factors issues were identified which require your attention.

We request that you consider the two issues as identified in the July 2, 1993

-memo and provide your evaluation and conclusions by August 31, 1993.

Attachment:

As stated

Contact:

L. Engle, 504-1480 Distribution See next page OFC LA: PDII-2 NAME ET~

DATE

[' / / h/93 OFFICIAL RECORD COPY

'?:-fl b /93

. (Original Signed By)

Herbert N. Berkow, Director Project Directorate II-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

<qik/93

_______ FILEN_AM~: A: BYP~S~: NA2 ____ _18 Q O 4 0 9309130271 930816

\\

PDR ADOCK 05000280 5

PDR

August 16, 1993 Memorandum Dated Di stri but "ion

>Docket; Fi *1 e_,*i

. NRC & Lod1.l"PDRs PDII-2 RF S. Varga G. Lainas J. Partlow B. Boger B. Buckley H. Berkow E. Tana L. Engle OGC ACRS (10)

M. Sinkule, RII

r.

ATTACHMENT

.* 08-1 3-1 '3'33 ta:=:: -HAM

-.JHITE FLINT P.02 uNITc.lJ STATES NUCLEAR REGULATORY.COMMISSION WASHINGTON. D.C. 20$55-<l001 July 2. 1?93 Thomas E. Murley, Director, NRR Stewart D. Ebneter, Regional Administrator, Rll MEMORANDUM FOR:

FROM:

Edward L. Jordan, Director, AEOD SUS.:IECT:

HUMAN PERFORMANCE STUOY REPORT - NORTH ANNA 2, 4/16/93 I hc1ve provided a copy of the subject report directly to you for information in ciddition to the normal distribution to members of your staff because of two issues identified by the report.

1.

This event represents an additional instance in which operators inappropriately bypassed an ESF, the Auxiliary Feedwater System, after a valid initiation during the response to an event.

The auxiliary feed system was inoperable for 18 minutes until the discrepancy was identified and the equipment was restarted to operability.

2.

A man-machine interface weakness was noted in which the operator at the i

  • controls needs a spotter at important recorders to provide readings.

Int'>

<.1 one case th i s led tel. a fl ow adj us tmen t to the wrong steam genera tor due J to a conmunication error.

The first issue is further evidence of a TMI lesson that has faded desp1te an Information Notice la.st year.

The second issue comes at a t1me that Vfrg1nia Pow1~r has determrned that earlier contro 1 room man-machine upgrades at Surry are no longer necessary.

I have asked my staff to check with the PM of Surry and North Anna regarding,this particular HF issue.

Att:achment:

Human Performance Stu, N1orth Anna 2 cc: J. Rosenthal 9309-13028'5-930816

DR ADOCK 05000280 PDR

. Jordan, Director for Analysis and Evaluatio

-:-*-,